Planning Page for E/D Nights UT Nov 30- Dec 3
Critical Dates/Times:
- PEPSI Observations 1st half UT Dec 01 (Nov 30 local time) - handover 00:00hr
- PEPSI Pol installation Dec 1 (daytime)
- PEPSI Observations 2nd half UT Dec 03 (Dec 02 local time) - handover 00:00hr - PEPSI observations scheduled to start 23:55 local time
- Optimal Mars observations times
- UT Dec 01 (Nov 30 local) - UT 03:20hr (20:20 local)
- UT Dec 02 (Dec 01 local) - UT 02:30hr (19:30 local)
- UT Dec 03 (Dec 02 local) - UT 01:30hr (18:30 local)
- UT Dec 03 (Dec 02 local) - UT 05:00hr (22:00 local)
- Transit Times of HD 33632
- UT Nov 30 07:5 1hr
- UT Dec 1 07:47 hr
- UT Dec 2 07:43 hr
- UT Dec 3 07:39 hr
Tasks:
- AGW3/4 checkout for PEPSIPOL - Dec 01 or Dec 02
- 1 hour for basic guiding and active optics checkout on AGW3 and AGW4 (critical, most any decent conditions)
- 3 hours for further AGW3 and AGW4 work on IT 7545 which ended softly (medium-high)
- 2 hours for AGW3 and AGW4 alignment (medium)
- Polarimteric standard calibrator gamma equ (21:10:20 +10:07:53 - hits 30deg limit at 21hr local time) - 0.5 hr
- LBC Technical Work
- Focus offsets (2hrs)
- On-sky Gain/Linearity measurements (using commissioning methods) (2hrs). This requires photometric skies.
- TMS passive data collection in parallel with LBC-Red (whenever LBC-Red is used w/o LUCI1)
- TMS: a few hours to run TMS actively controlling the LBC-Red Collimation
- AO Technical Work
- SOUL/LUCI Mars Observations (see below for details) - thin cirrus DIMM 1.2" or better - 1st half time constraint
- Scripts: /home/lbto/Service_Observing/Nov_Dec_2020_E_D_Nights/Mars_AO
- SOUL/LUCI ADI observations HD 33632 -1st half time constraint - bright target requires sub-framing - thin cirrus DIMM 1.2" or better - LBTI part POSTPONED UNTIL DEC
- SOUL/LUCI Bin 4 checks - DIMM 1.2" or better
- Science Programs
-
GRB 200826A - AO H-band observations (2hrs) - Rothberg (rollover from last D nights) - clear preferred, thin cirrus OK, DIMM 1" or better - 1st half of night
- Scripts: /home/lbto/Service_Observing/Nov_Dec_2020_E_D_Nights/GRB_200826A
- Observe PSF star along with science target - AORef star manually set to R=16.51 to force Bin 4
- UDS z~10 target - ESM/L1 spectroscopy w/L2 (SL) in parallel (3 hrs) - Rothberg (rollover from last D nights) - clear preferred, thin cirrus acceptable DIMM 1" or better - 1st half of night
- Scripts: /home/lbto/Service_Observing/Nov_Dec_2020_E_D_Nights/UDS_z10_ESM_Science
- Observations are mixed-mode: L1-ESM and L2-SL. Same setup on both sides (N3.75, G210 HKspec, CWL=1.6, 0.75" slit)
- Blind offset along slit - center on AO Ref first then offset to faint galaxy - target is H=25.3 (won't see in acq images). AO Ref star remains in slit during observations
- Poor Weather/Poor Seeing Condition Programs
- ESM data collection M34 (3 filters) , M52 (3 filters and bright and faint AO Ref star), M67 (3 filters and bright and faint AO Ref star) - if you can close the loop take the data
- ICRF3 Spectroscopy (Rothberg)
- Scripts: /home/lbto/Service_Observing/Nov_Dec_2020_E_D_Nights/Poor_Weather/ICRF3_Rothberg_2020B
- Observe telluric first
- Double Check high Dec objects to make sure tellurc/science are close spatially
- If clear but poor seeing, please observe standard stars, cycling through z,J,H,K,Ks
- Scripts: /home/lbto/Service_Observing/Nov_Dec_2020_E_D_Nights/Poor_Weather/LUCI_Phot_ZP
- Select stars to use based on visibility - OT file is in directory, export the scripts as needed
- Please observe the same star at least two times at different airmasses
Phobos
* Date__(UT)__HR:MN Azi_(a-appr)_Elev_X(sat-pri)_Y SatPANG APmag S-brt ang-sep/v
2020-Dec-01 03:20 m 168.3290 63.5206 14.398 1.705 83.246 11.676 4.907 14.4985/u
2020-Dec-01 03:30 m 173.8954 63.8479 15.563 3.479 77.400 11.676 4.907 15.9469/*
2020-Dec-01 03:40 m 179.5489 63.9699 16.436 5.187 72.485 11.676 4.907 17.2348/*
2020-Dec-01 03:50 t 185.2095 63.8835 16.998 6.797 68.206 11.676 4.907 18.3067/*
2020-Dec-01 04:00 m 190.7967 63.5910 17.238 8.277 64.351 11.677 4.907 19.1223/*
2020-Dec-01 04:10 m 196.2368 63.0989 17.149 9.600 60.760 11.677 4.907 19.6527/*
2020-Dec-01 04:20 m 201.4686 62.4182 16.730 10.738 57.306 11.677 4.907 19.8794/*
2020-Dec-01 04:30 m 206.4471 61.5624 15.989 11.668 53.878 11.677 4.907 19.7938/*
2020-Dec-01 04:40 m 211.1444 60.5470 14.938 12.373 50.365 11.677 4.907 19.3970/*
2020-Dec-01 04:50 m 215.5474 59.3881 13.597 12.837 46.647 11.677 4.907 18.6998/*
2020-Dec-01 05:00 m 219.6559 58.1016 11.992 13.051 42.578 11.677 4.907 17.7238/*
2020-Dec-01 05:10 m 223.4788 56.7026 10.152 13.010 37.966 11.678 4.907 16.5025/*
2020-Dec-01 05:20 m 227.0315 55.2049 8.115 12.715 32.546 11.678 4.907 15.0837/*
2020-Dec-02 02:30 m 145.0482 59.6779 15.581 3.801 76.292 11.702 4.907 16.0382/*
2020-Dec-02 02:40 m 149.5046 60.8193 16.384 5.475 71.522 11.702 4.907 17.2740/*
2020-Dec-02 02:50 m 154.2571 61.8146 16.876 7.045 67.340 11.702 4.907 18.2875/*
2020-Dec-02 03:00 m 159.2909 62.6478 17.048 8.482 63.548 11.702 4.907 19.0410/*
2020-Dec-02 03:10 m 164.5754 63.3033 16.894 9.756 59.994 11.702 4.907 19.5081/*
2020-Dec-02 03:20 m 170.0626 63.7677 16.415 10.842 56.554 11.702 4.907 19.6724/*
2020-Dec-02 03:30 m 175.6888 64.0305 15.620 11.720 53.118 11.702 4.907 19.5273/*
2020-Dec-02 03:40 t 181.3776 64.0855 14.522 12.369 49.576 11.703 4.907 19.0757/*
2020-Dec-02 03:50 m 187.0470 63.9315 13.142 12.779 45.802 11.703 4.907 18.3303/*
2020-Dec-02 04:00 m 192.6167 63.5719 11.506 12.939 41.644 11.703 4.907 17.3147/*
2020-Dec-02 04:10 m 198.0156 63.0153 9.645 12.846 36.899 11.703 4.907 16.0644/*
2020-Dec-03 01:30 A 124.8489 51.2335 15.584 4.112 75.219 11.727 4.907 16.1172/*
2020-Dec-03 01:40 A 127.8047 52.9332 16.316 5.751 70.583 11.727 4.907 17.3004/*
2020-Dec-03 01:50 130.9821 54.5638 16.740 7.282 66.491 11.727 4.907 18.2556/*
2020-Dec-03 02:00 134.4026 56.1148 16.846 8.674 62.756 11.727 4.907 18.9477/*
2020-Dec-03 02:10 m 138.0868 57.5744 16.629 9.899 59.234 11.728 4.907 19.3526/*
2020-Dec-03 02:20 m 142.0532 58.9291 16.093 10.935 55.804 11.728 4.907 19.4561/*
2020-Dec-03 02:30 m 146.3150 60.1645 15.246 11.759 52.357 11.728 4.907 19.2533/*
2020-Dec-03 02:40 m 150.8780 61.2647 14.103 12.354 48.780 11.728 4.907 18.7490/*
2020-Dec-03 02:50 m 155.7369 62.2134 12.686 12.710 44.946 11.728 4.907 17.9577/*
2020-Dec-03 03:00 m 160.8723 62.9943 11.022 12.817 40.693 11.728 4.907 16.9050/*
2020-Dec-03 03:10 m 166.2477 63.5924 9.143 12.675 35.806 11.728 4.907 15.6284/*
2020-Dec-03 05:00 m 222.3884 57.4116 -13.844 -1.462 263.970 11.730 4.907 13.9213/*
2020-Dec-03 05:10 m 226.0420 55.9410 -15.074 -3.215 257.959 11.731 4.907 15.4134/*
2020-Dec-03 05:20 m 229.4342 54.3804 -16.023 -4.908 252.969 11.731 4.907 16.7578/*
2020-Dec-03 05:30 m 232.5857 52.7415 -16.674 -6.510 248.674 11.731 4.907 17.9000/*
2020-Dec-03 05:40 m 235.5183 51.0347 -17.018 -7.991 244.848 11.731 4.907 18.8010/*
2020-Dec-03 05:50 m 238.2530 49.2689 -17.050 -9.326 241.324 11.731 4.907 19.4339/*
2020-Dec-03 06:00 m 240.8099 47.4519 -16.771 -10.490 237.976 11.732 4.907 19.7818/*
2020-Dec-03 06:10 m 243.2079 45.5905 -16.188 -11.464 234.696 11.732 4.907 19.8363/*
2020-Dec-03 06:20 m 245.4641 43.6906 -15.313 -12.230 231.386 11.732 4.907 19.5977/*
2020-Dec-03 06:30 m 247.5940 41.7573 -14.162 -12.777 227.944 11.732 4.907 19.0738/*
2020-Dec-03 06:40 m 249.6118 39.7949 -12.757 -13.094 224.255 11.733 4.907 18.2811/*
2020-Dec-03 06:50 m 251.5300 37.8074 -11.125 -13.176 220.175 11.733 4.907 17.2444/*
2020-Dec-03 07:00 m 253.3602 35.7981 -9.293 -13.023 215.512 11.733 4.907 15.9989/*
2020-Dec-03 07:10 m 255.1125 33.7700 -7.296 -12.637 210.000 11.733 4.907 14.5923/*