Plan for E/D Nights 04-07 Feb 2020 UT
Engineering
IRTC on SX - AO data collection (pending install) - high priority
Instructions for Running IRTC:
https://wiki.lbto.org/Commissioning/RunningTheIRTC
Mixed-mode LBC/LUCI tests - dithering tests - medium priority - 0.5 hr - presets worked in full binocular mode
Contingency roll-over of LUCI-2/AGW-2
More thorough checks on Rot ZP, collect transform confirmatory data for LUCI-2 - 1hr
TCS + MCSPU 2020B release - testing occurs during regular use of telescope
Alarm Handling System move to its own dedicated VM - low priority, transparent - testing occurs during regular use of telescope
2x rm507 64bits rollout - staff to use machines during nighttime operations
Standards for LUCI-2 - LUCI_PhotZP.tar.gz - on Google Drive
Photometric standard observations - 2 airmasses minimum, execute only if sure absolutley clear
Closed-Dome testing
UT 04-Feb LN 2nd half
UT 04-Feb - AZ calibrations
No Arcetri closed dome work befor UT 08-Feb
Last two hours of UT 06-Feb and 07-Feb are PEPSI tests for faint targets - remote from Potsdam.
D-targets
A. Conrad/C. Veillet
Geo-Sync satellite - requires IRTC on SX w/SOUL AO (contingent upon LUCI-1 removal and IRTC install)
O. Kuhn
Files located: OBS-N: /home/lbto/Service_Observing/Eng_Jan_2020/
Q1237+134 - MODS Bino +zJ LUCI - 1.5 hours with overheads (both MODS + LUCI observations)
M. Edwards
Files located: OBS-N: /home/lbto/Service_Observing/Eng_Jan_2020/
M33-7 - MODS-Bino (1.5-2.5 hr conditon dependent) - visible until 10pm
NGC 2403-5 - MODS-Bino (1.5-2.5 hr conditon dependent) - visible twilight-to-twilight
M. Wagner
Files located: OBS-N: /home/lbto/Service_Observing/Eng_Jan_2020/
Novae Targets - MODS-Bino Dual Grating (0.75 hours per target)
V392 Per
04:43:21.37
47:21:25.87
V2860 Ori
06:09:57.453
12:12:25.15
V959 Mon
06:39:38.61
05:49:26.74
V435 CMa
07:13:45.84
-21:12:31.3
B. Rothberg
Files located: OBS-N: /home/lbto/Service_Observing/Eng_Jan_2020/Triple_AGNs_Rothberg_LD_2019B_007
LUCI observations have priority over MODS
Triple Merger Candidate SDSSJ 0838+5055 - visible twilight untl 5am (hits 30deg limit)
LUCI-2 - 2.75 hrs G200 1" slit HKspec
MODS-Bino - 1 hr Dual Grating 1" slit
Requires 1" or better on AGW/WFS
Triple Merger Candidate SDSSJ 0853+5245- visible twilight untl 5:30am (hits 30deg limit)
LUCI-2 - 2.75 hrs G200 1" slit HKspec
MODS-Bino - 1 hr Dual Grating 1" slit
Requires 1" or better on AGW/WFS
Triple Merger Candidate SDSS J1342+19133- all 2nd half - higher priority
LUCI-2 - 2.75 hrs G200 1" slit HKspec
MODS-Bino - 1 hr Dual Grating 1" slit
nuclei separations are 5" and 8" - so looser constraintes
Poor Weather Backup Targets - in case no AO/IRTC data collection can be done
B. Rothberg
Local Mergers - MODS Bino or LUCI-2
Files are located on
OBS-N: /home/lbto/Service_Observing/Eng_Jan_2020/Rothberg_Local_Mergers/
OR RM507-5/4: /home/observer/share/Service_Observing/Eng_Jan_2020/Rothberg_Local_Mergers/
MODS (dual grating)
UGC 4079 - 07:55:06 +55:42:13 - 1 hour
NGC 3310 - 10:38:45 +53:30:11 - 1 hour
NGC 2744 - 09:04:39 +18:27:52 - 1 hour
NGC 6598 - 18:08:56 +69:04:04 - 1 hour (end of night)
LUCI-2
Files are located on
OBS-N: /home/lbto/Service_Observing/Eng_Jan_2020/Rothberg_Local_Mergers/
OR on RM507-5: /home/observer/share/
Service_Observing/Eng_Jan_2020/Rothberg_Local_Mergers
/
Arp 187 - 05:04:53 -10:14:52 - visible until 11:30pm - 2 hours (covers zJ and HKspec observations) - G200 HK/zJspec observations
NGC 455 - 01:15:57 +05:10:43 (requires the CWL 2.27 cals) G210 K-band
Arp 156 - 10:42:38 +77:29:41 (requires the CWL 2.3 cals) G210 K-band
ICRF3 project with USNO - uploaded to google drive - mostly first half/first 2/3rds targets
H-band Library (poorest conditions)
STAR: RA Dec Class Hmag
HD 20797 03 24 40.55 +64 35 09.57
M0Iab
0.5
HD 42543 06 12 19.10 +22 54 30.7
M2I
0.9
HD 44537 06 24 53.90 +49 17 16.4
M2I
0.8
BD -15 1319 06 15 01.88 -15 52 49.7
K5III
6.4
--
BarryRothberg
- 28 Jan 2020
This topic: Commissioning
>
Main
>
WebHome
>
Com2020Feb_E_D_NightPlan
Topic revision:
06 Feb 2020,
BarryRothberg