Summary:
Confirmed rotatorZP data on stoneO mods mask and longslit method. Executed large throw dither observations on M52 and NGC40. A large circular bloc was noted in the lower right quadrant of the luci2 images. There appares to be something on or near the luci2 entrance window (IT8178). Errors appear ed to accumulate when executing large dither offsets over an extended period of time (IT8179). We obtained transform data for LUCI1 and LUCI2 onthe
StoneO field in ~1.2" seeing. Executed a LUCI binoscular nonsidereal imaging observation without issue. High humidity moved in when we switched to MODS for Longslit observations. Taking flexure N30 Imaging flexure compensation data while we were in fog.
Problems:
IT 8178 Blob on LUCI2 entrance window.
IT 8179 Copointing warnings from accumulating errors when repeating offsets.
Proposed Plan:
- LUCI-1 - CRITICAL PRIORITY
-
L1 Rotator ZP for AGW - (1 hr) - critical
- Long Slit Method - instructions to be provided by J. Power - to be compared with results from last night
-
AGW Transform for both LUCIs (use the N30 fieldstop, H or FeII filters) - (2 hr) - high/critical
- LUCI-1 Imaging check (can run LUCI-2 in parallel to repeat) - high
- Important to test in and out of field to "stress-test" AGW-1 - does it recover from long throws? and multi-point dithers?
- Sidereal
- Dither in-field
- J1601 (sets around 10pm) - dithering in the field -Kband only
- NGC 7027 (sets 4am) - cycles through all filters, can stop early
- Dither out-of-field
- (K only) M52 - (all night) - KJH
- FAILED (IT8179) NGC 40 - (all night) - all filters
-
NS
- Comet 29/P - (after 10pm) - JHK - updated for UT 02 Sep 2020
- Twilight Flats - low
- as of 2020-Sep-1, we have LBCR flats @ r-SLOAN, R-BESSEL, i-SLOAN, Y-FAN and F972N20.
- We need LBCR: z-SLOAN, I-BESSEL and V-BESSEL and all LBCB filters.
- Photometric Standards - (1-2hrs) - medium - only if clear - any seeing
- AFTER LUCI-1 checkout:
- LBCs - LBC-Blue is primary focus, but we should run binocularly, LBCB+LBCR.
- Collimate WRS/DOFPIA - high (4 x 0.25 hrs) - to check LBC-Blue
- Superfocus sequence -PA=0,180 high (1 hr) - to check LBC-Blue but gather more LBC-Red data.
- Rotator Center Checks, start with PA=0, 180 (track mode), then 90,270 - high (1hr) - to check LBC-Blue and gather more LBC-Red data.
- Test Science OB - guiding - medium (1hr)
- Standard Photometric fields - requires clear skies - any seeing
- Spectrophotometric Standards - requires clear skies - any seeing
- Twlight Flats
- Mixed Mode LBC-B/MODS2 (see below)
- MODS
- Spectrophotometric stars if clear (and if not clear only if taking data)
- Photometric Standards - (1 hr) - only if clear - any seeing
- Mixed Mode LBC-B/MODS-2
- Skyflats MODS2-Blue
- as of 2020-Sep-01, we have Dual: g + r,i and Red-only: r,z
- Revisit Transient - (1hr) - Med/High
- Same spectroscopy scripts (run 2x extra eposures - total of 4x900sec each channel)
- If too faint for spectroscopy, take u,g,r,i,z imaging - script TBD
Closed Dome Activities
- LUCI-Bino Flexure (requires moving telescope: elevation and RFBG/LFBG rotator)
- LUCI1/2 Wavelength Calibration
Night Log:
all images below are luci1/2.20200902.####
1:00 Josh is brining up. the WFS. Bringing up LUCI and mods. Tweaking luci1 feild stop alignment. MODS seqinit run and sievesnap taken. LBC's up and running.
1:50 Josh is keeping us closed while we wait out a spike in humidity. Monitoring the trend. Taking some LBC and MODS biases and LUCI darks in the mean time.
2:16 Humidity has levelled off. Josh is going to open. Thin cirrus.
2:28 Josh is sending pointing and collimation preset. Seeing 1.0-1.2" on the wfs
2:43 Preset to
StonOLS. The field is low but doable. Seeing 1.25-1.5" on the WFS
RTD Bug with loading longslit lms files. Had to load MOS acquisition from yesterday containing horizontal alignment holes to kick rtd into gear. Igor is aware of bug. We are using an unreleased feature of rtd...
- Acquisition L1 0612-0614 L2 0612-0614
- LUCI1 Xoffset. 0.94 YOffset -1.88 Angle -0.07 Error RA/DEC 0.06 0.08
- LUCI2 Xoffset. -0.07 YOffset -3.72 Angle 0.15 Error RA/DEC 0.06 0.05
- Updating RIGHTSEROPOINT PCSInstrument.conf and restarting PCS from 177.15 to 176.05
- Acquisition L1 0615-617 L2 0615-617
- LUCI1 Xoffset. 0.83 YOffset -1.80 Angle -0.07 Error RA/DEC 0.07 0.09
- LUCI2 Xoffset. 0.27 YOffset -2.86 Angle -0.02 Error RA/DEC 0.07 0.08
- Confirmation image L1/L2 618, Looks really good. Seeing is variable but ~1.7-2"
3:30- Seeing is crap so we are going to reconfirm the
StonO MOS mask while we wait for it to settle. Seeig 2.4-2.8"
- Acquisition L1 0619-621 L2 0619-621
- LUCI1 Xoffset. 1.09 YOffset -2.19 Angle -0.02 Error RA/DEC 0.07 0.09
- LUCI2 Xoffset. 0.21 YOffset -3.68 Angle -0.004 Error RA/DEC 0.08 0.08
- Confirmation image 0621, Looks really good. Seeing is variable but ~2.7 for the most part.
3:48 Seeing is too poor for transform work ~2.8". Reverting PCSInstruemnt.conf and restring PCS. Configuration with good numbers are PCSInstrument.con.20200902_2. Moving on to M52 Imaging to test dither in/out of field. Significant trefoil that was not clearing when we got there so Josh cleared it and restarted collimation.
M52 K L1 0623-632 L2 0623-632
Seeing is already rebouding, improvived to ~1.05" on WFS. Will finish K fileter and see if this seeing trend holds, themn move to transform field.
Seomthign weird on LUCI2 images. Very bright blob started appearing ~0624 K images. Could it be the reflection from the moon? Theat side is in the moon light. Light from WFS? Not visible in J (633-634) Switching to H (635-636). There is a shadow now where the bright blob was suggesting somethign is infront of the luci2 entrance window
Barry logged in and took a look at the images. he submitted IT 8178.
4:30 Seeing has improved and appears stable ~1.2". Updated PCSInstrument.conf and restarted PCS and moving to transform field.
luci2 on stoneO just taking an image (with guide probe in the field). Blob is still present.
4:48 Starting collection of transform data on
StoneO - Stone_O180pm10_luci.list. Seeing 0.9-1.2" on WFS. EXP=4, H filter, N30 fieldstop, N375 in FPU
- Starting at L1 0638-704 L2-0638-672
- GS11 vignetting in luci patrol field.
- GS 23 is very faint and left did not catch it, right barely did. Skipping GS23 (item5) on lfbg and restarting on item 6
- Note NEXP set to 2 for lfbg for some reason? although not falling behind LUCI2 so not stopping to correct it. Will correct on next failure or if it falls behind too much
- GS1 PA190 on rfbg failed first try. Looks like it tried to grab before rotator finished getting to position. Restarting transform collect at item12 in transform list
- 5:15 Seeing is holding stable at ~1.05-1.2"
- GS 12 PA170 on rfbg missed, restart at item 32 (second from last)
- GS10 PA`70 on lfbg failed. Last star, not worth restarting
/home/lbto/data/20200902/lfbg/lfbg.log
#Title LUCI1 Transformation 20200902
#Date 20200902
#Type agw_transformation
#Station LFBG
#Instrument LUCI1
#Data_Dir /Repository/20200902
#Bg_Available 1
#Dark_Available 0
#Labels GS PCS_X PCS_Y AGW_X_Req AGW_Y_Req AGW_X_Ach AGW_Y_Ach
RotAng PosAng Image Num Image File Image Type
0 0.0000 150.0000 -0.8927 461.9270 -0.9300 461.9250 218.4611 180.0000 640 luci1.20200902.0642.fits Background
0 0.0000 150.0000 -0.8927 461.9270 -0.9300 461.9250 218.4611 180.0000 640 luci1.20200902.0640.fits On-Axis
1 -6.0768 9.6354 6.0252 602.5190 6.0370 602.5170 217.6982 180.0000 644 luci1.20200902.0644.fits Field
11 43.7789 81.9926 -44.3750 530.2973 -44.3860 530.2950 217.3205 180.0000 646 luci1.20200902.0646.fits Field
15 23.1133 119.2658 -23.8798 492.8432 -23.8680 492.8410 216.9547 180.0000 648 luci1.20200902.0648.fits Field
24 17.0694 146.0290 -17.9792 465.9977 -17.9800 465.9960 216.0802 180.0000 650 luci1.20200902.0650.fits Field
28 -1.5639 150.7894 0.6703 461.1277 0.6740 461.1260 214.8460 180.0000 652 luci1.20200902.0652.fits Field
26 -18.4319 147.5740 17.5972 464.2578 17.6010 464.2560 214.4368 180.0000 654 luci1.20200902.0654.fits Field
33 2.8062 168.2326 -3.8129 443.6758 -3.8180 443.6750 214.0327 180.0000 656 luci1.20200902.0656.fits Field
32 -16.1885 166.6591 15.2361 445.1494 15.2420 445.1460 213.2039 180.0000 658 luci1.20200902.0658.fits Field
12 -41.9795 97.0548 41.4983 514.7432 41.5070 514.7400 212.7764 180.0000 660 luci1.20200902.0660.fits Field
10 -61.8688 69.4380 61.5974 542.3035 61.6010 542.3020 212.3595 180.0000 662 luci1.20200902.0662.fits Field
1 -4.2767 10.5451 4.2155 601.6173 4.2250 601.6150 220.6951 190.0000 664 luci1.20200902.0664.fits Field
11 57.3883 73.1466 -57.9645 539.2334 -57.9810 539.2290 220.2462 190.0000 666 luci1.20200902.0666.fits Field
15 43.5092 113.4417 -44.2898 498.7885 -44.2900 498.7860 219.8080 190.0000 668 luci1.20200902.0668.fits Field
24 42.2038 140.8475 -43.1427 471.3248 -43.1610 471.3210 218.9301 190.0000 670 luci1.20200902.0670.fits Field
23 29.4634 143.6378 -30.3886 468.4604 -30.3810 468.4590 218.5076 190.0000 672 luci1.20200902.0672.fits Field
28 24.6774 148.7707 -25.6215 463.2921 -25.6100 463.2910 217.9987 190.0000 674 luci1.20200902.0674.fits Field
26 7.5087 148.5328 -8.4106 463.4375 -8.4320 463.4360 217.0047 190.0000 676 luci1.20200902.0676.fits Field
33 32.0125 165.1898 -33.0706 446.8822 -33.0710 446.8800 216.5260 190.0000 678 luci1.20200902.0678.fits Field
32 13.0299 166.9371 -14.0533 445.0290 -14.0530 445.0270 216.0561 190.0000 680 luci1.20200902.0680.fits Field
12 -24.4550 102.8692 23.8980 509.0128 23.9050 509.0100 215.0521 190.0000 682 luci1.20200902.0682.fits Field
10 -48.8382 79.1253 48.4788 532.6688 48.4950 532.6650 214.5488 190.0000 684 luci1.20200902.0684.fits Field
1 -7.5995 8.4552 7.5585 603.6932 7.5530 603.6910 194.0537 170.0000 686 luci1.20200902.0686.fits Field
11 28.9385 88.3735 -29.5369 523.8243 -29.5610 523.8210 192.9772 170.0000 688 luci1.20200902.0688.fits Field
15 2.1151 121.4915 -2.8449 490.4998 -2.8220 490.4990 192.4889 170.0000 690 luci1.20200902.0690.fits Field
24 -8.4862 146.7975 7.6324 465.0896 7.6370 465.0880 191.9921 170.0000 692 luci1.20200902.0692.fits Field
23 -21.4088 145.0627 20.5959 466.7576 20.5980 466.7560 190.2610 170.0000 694 luci1.20200902.0694.fits Field
28 -27.6611 148.2491 26.8443 463.5315 26.8610 463.5290 189.7311 170.0000 696 luci1.20200902.0696.fits Field
26 -43.7154 142.1524 42.9726 469.5526 42.9870 469.5510 189.2157 170.0000 698 luci1.20200902.0698.fits Field
33 -26.3847 166.1863 25.4592 445.5680 25.4770 445.5660 188.0347 170.0000 700 luci1.20200902.0700.fits Field
32 -44.8196 161.3355 43.9664 450.3280 43.9820 450.3240 547.4385 170.0000 702 luci1.20200902.0702.fits Field
12 -58.1340 88.3094 57.7426 523.4175 57.7530 523.4140 546.8568 170.0000 704 luci1.20200902.0704.fits Field
/home/lbto/data/20200902/rfbg/rfbg.log
#Title LUCI2 Transformation 20200902
#Date 20200902
#Type agw_transformation
#Station RFBG
#Instrument LUCI2
#Data_Dir /Repository/20200902
#Bg_Available 1
#Dark_Available 0
#Labels GS PCS_X PCS_Y AGW_X_Req AGW_Y_Req AGW_X_Ach AGW_Y_Ach
RotAng PosAng Image Num Image File Image Type
0 0.0000 150.0000 1.2103 462.0545 1.2180 462.0550 -146.1980 180.0000 639 luci2.20200902.0640.fits Background
0 0.0000 150.0000 1.2103 462.0545 1.2180 462.0550 -146.1980 180.0000 639 luci2.20200902.0639.fits On-Axis
1 -6.0760 9.6355 6.1718 602.8849 6.1850 602.8840 -147.1274 180.0000 641 luci2.20200902.0641.fits Field
11 43.7795 81.9928 -43.2479 529.9105 -43.2670 529.9090 -147.4506 180.0000 642 luci2.20200902.0642.fits Field
15 23.1134 119.2658 -22.2197 492.6935 -22.2160 492.6930 -147.7979 180.0000 643 luci2.20200902.0643.fits Field
24 17.0687 146.0288 -15.9411 465.8998 -15.9410 465.9000 -148.4982 180.0000 644 luci2.20200902.0644.fits Field
23 4.0373 146.5646 -2.8667 465.4675 -2.8560 465.4680 -148.8302 180.0000 645 luci2.20200902.0645.fits Field
28 -1.5669 150.7886 2.7882 461.2762 2.7970 461.2760 -149.1716 180.0000 646 luci2.20200902.0646.fits Field
26 -18.4340 147.5735 19.6795 464.6369 19.6790 464.6370 -149.9199 180.0000 647 luci2.20200902.0647.fits Field
33 2.8042 168.2322 -1.4551 443.7455 -1.4570 443.7460 -150.2685 180.0000 648 luci2.20200902.0648.fits Field
32 -16.1934 166.6570 17.5862 445.4787 17.5730 445.4780 -150.6585 180.0000 648 luci2.20200902.0648.fits Field
12 -41.9818 97.0544 42.8897 515.4961 42.8980 515.4950 -151.4788 180.0000 648 luci2.20200902.0648.fits Field
10 -61.8715 69.4376 62.6155 543.3554 62.6180 543.3540 -151.7992 180.0000 649 luci2.20200902.0649.fits Field
1 -4.2777 10.5451 4.3755 601.9581 4.3720 601.9580 -143.7443 190.0000 650 luci2.20200902.0650.fits Field
11 57.3867 73.1466 -56.9669 538.6732 -56.9810 538.6720 -144.0929 190.0000 651 luci2.20200902.0651.fits Field
15 43.5072 113.4417 -42.7211 498.3703 -42.7120 498.3710 -144.4762 190.0000 652 luci2.20200902.0652.fits Field
24 42.2015 140.8475 -41.1903 470.8936 -41.1990 470.8930 -145.2504 190.0000 653 luci2.20200902.0653.fits Field
23 29.4608 143.6378 -28.3893 468.1979 -28.3700 468.1990 -145.6104 190.0000 654 luci2.20200902.0654.fits Field
28 24.6745 148.7707 -23.5474 463.0884 -23.5400 463.0880 -145.9603 190.0000 655 luci2.20200902.0655.fits Field
26 7.5060 148.5329 -6.3298 463.4654 -6.3430 463.4650 -146.9837 190.0000 656 luci2.20200902.0656.fits Field
33 32.0089 165.1899 -30.7711 446.5612 -30.7670 446.5610 -147.3497 190.0000 657 luci2.20200902.0657.fits Field
32 13.0261 166.9372 -11.7178 444.9619 -11.7240 444.9620 -147.7336 190.0000 658 luci2.20200902.0658.fits Field
12 -24.4590 102.8694 25.3617 509.5224 25.3740 509.5210 -148.6534 190.0000 659 luci2.20200902.0659.fits Field
10 -48.8425 79.1256 49.6260 533.5336 49.6320 533.5330 -149.0468 190.0000 660 luci2.20200902.0660.fits Field
1 -7.6038 8.4538 7.6946 604.0825 7.6740 604.0800 -169.4428 170.0000 661 luci2.20200902.0661.fits Field
11 28.9337 88.3719 -28.3065 523.6322 -28.3170 523.6300 -170.4174 170.0000 662 luci2.20200902.0662.fits Field
15 2.1099 121.4898 -1.1359 490.6324 -1.1290 490.6310 -170.8220 170.0000 663 luci2.20200902.0663.fits Field
24 -8.4917 146.7957 9.7014 465.3369 9.6940 465.3370 -171.2263 170.0000 664 luci2.20200902.0664.fits Field
23 -21.4173 145.0602 22.6514 467.1818 22.6590 467.1810 -172.1169 170.0000 665 luci2.20200902.0665.fits Field
28 -27.6700 148.2466 28.9484 464.0364 28.9550 464.0340 -172.5527 170.0000 666 luci2.20200902.0666.fits Field
26 -43.7246 142.1499 45.0014 470.2808 44.9980 470.2790 -172.9515 170.0000 667 luci2.20200902.0667.fits Field
33 -26.3946 166.1835 27.8139 446.0359 27.8100 446.0350 -173.8846 170.0000 668 luci2.20200902.0668.fits Field
32 -44.8300 161.3327 46.2649 451.0499 46.2590 451.0480 -174.2979 170.0000 669 luci2.20200902.0669.fits Field
12 -58.1397 88.3080 59.0249 524.3989 59.0320 524.3970 -176.2375 170.0000 670 luci2.20200902.0670.fits Field
10 -72.9321 57.6559 73.6139 555.2614 73.6240 555.2580 -176.6834 170.0000 671 luci2.20200902.0671.fits Field
0 -0.0002 -0.1918 -0.0013 612.6923 -0.0150 612.6900 182.6087 170.0000 672 luci2.20200902.0672.fits On-Axis
We are moving on to
OSCO
6:01 Reverting PCSInstrument.conf, restarting PCS. Reauthorizing as LUCI1 only.
6:06 OSCO script sent to HD216399. Greg has joined
- running in automatic, lets see if this works first try - Gains 4.09 0.73 0.63, then applies optical gain. Optical gain step failed, cand caused going into safe skip, seeing bubble? Unsure but resending.
- Gains 3.13 0.66 0.63 optical gains applied Worked! 0.69, 0.14,0.15. Filter echo seperation looks ok on luci.
- OSCO imaged luci1.20200902.0705-724
6:24 Reauthorized Bino LUCI again. Going to Comet 29P> Actually, this target is not up yet. Returning to imaging. Going to NGC40 to cycle through all filters. Seeing 1"
- L1 0725-759 L2 0673-707 The circular blob remains on luci2
- on a 300, 300 offset about 20 images in we got a copoing limit warning from the tcs. nothing failed but it was weird. We got the same copointing warning on the next sky and every sky offsset since.
Target on both sides greater than 41" from midpoint
second one said target greater than 43" from midpoint
third sky offset said target greater than 44" from midpoint
... We are repeating the same dither pattern over and over but the error from midpoint is accumulating. Josh is submitting an IT 8179
Seeing 0.9" - 1"
Failed outright on on sky offset after L1 0758 L2 0706 when error accumulated to 50" from midpoint (35th exposure. Resending offset to source then going to try again with sky. This again outright failed.
- Resending the preset. Then will resume and complete the last 2 brGamma exposure and continue with the other filters and see if the offset errors accumuilate. Broke the copointing limit immediately after preset. Elevation 50, now it is complaining that we are 55" from midpoint when sending a 300, -300 sky offset.
Resending Preset with a more watchful eye on the logs:
IIF is receiving synchronous commands. Preset did not clear this. Not sure? Disabiling copointing is one possibility. I think we have proven that there is an issue with robustness of large throws. This could have to do with the lack of transform accumulating errors? or some other software glitch? doesn't appear to be harware. Last images L1 759, L2 707. This requires additional investigation, but I think we have demonstrated there is an issue with the robustness of large throws (the purpose of this test). Revisit.
8:14 Moving on to the NS test for 90000392 Comet 29/P. Blob on LUCI2 lower right remains. Seeing 0.86" on WFS. Non sidereal rates applied without issue.
L1 0760-0774 L2 0708--0722, seeing 0.8-0.9" on WFS
08:42 Reconfiguring to MODS
09:00 Josh is doing pointing and collimation. Seeing 0.6" on guider
09:10 Preset to AT2020scz for longslit acquisition, blue on MODS2 and red acq on mods1.
9:30 Humidity is at 95.1% we are closing. Object was barely visible in 2 min exposure but we closed before any science obtained.
Taking a few LUCI DIT=4s blind blind exp while we are closed. Humidity is now 100%
10:13 The mountain has been overtaken by fog. Setting up to take N30 imaging flex comp data.
loading
FlexComp _Calib10.xml,
OptSpec _Sieve, N30, All 3 Halo lamps
test exp luci1.20200902.0785 luci2.20200902.0733
### N30+Mirror K Halo1,2,3
__LUCI1__ LUCI2
0786 0894 0734 0842 90
FlexComp_Calib10.xml
0895 0975 0843 0923 68 Left primary panicked, and had to abort to move to zenith to recover. Set incomplete
0976 1084 0924 1032 68
1085 1193 1033 1141 46
1194 1302 1142 1251 24
Pausing for fills, check of LUCI2 condensation, fix a problem.
-- BarryRothberg - 01 Sep 2020