Service Observer: Jenny
Telescope Operator: DGH
Plan: Hopefully LBTI (which is not logged here) but iff not, closed dome checkouts.
Summary:
Issues:
Weather: A few clouds, winds are dying down, humidity pegged
Overview:
02:20 Unable to ssh to adsec or lbti wfs machines. We are able to ping them though. Tried skipping alias and directly ssh’ing to ip, waiting but connection closed by machine.
02:39 called Stephen who heroically stepped in and helped troubleshoot
(insert various troubleshooting efforts here)
03:19 Stephen is going to call us back after investigating some more.
03:25 Working on bringing MODS up. Looks like comtrollers need restarting. I’m just going to bring things up cleanly from scratch.
03:43 Stephen has some ideas! And solved. Logged in as root, adjust sshd_config with some commands he provided. Happy!
03:50 Amali is bringing up adsecs, I’m working on MODS.
04:30 Ilya is having hte same problem but with ssh, so did the same sort of thing to that machine as we did to adsec and wfs. Can ssh to it now.
05:00. MODS is finally up. Brought up MODS2 software. I ended up restarting the comtrollers so started from scratch.
-Started the cronjob for MODS2 and also started up the MODS2 portion of the ISp daily report.
-Note that on the Post Shutdown page, the commands isisCmd --mods1 m1.ie agc and isisCmd --mods1 m1.ie wfs
-Should be isisCmd --mods1 m1.ie util agc and isisCmd --mods1 util m1.ie wfs
Checkout
OLD VALUES | NEW VALUES | |
mods1 bconfig.tab | # Direct-Mode Presets # Imaging Flat Any 3020 17062 17865 20176 3Kx3K 1 1 0 0 Slow Grating G400L Clear 3150 16746 18011 20177 Full 1 1 0 0 Slow Prism P450L Clear 3180 16792 17921 20393 4Kx3K 1 1 0 0 Slow Acquire Flat g_sdss 3020 17062 17865 20176 3Kx3K 2 2 0 0 Fast # # Dual-Mode Presets # DImaging Flat Any 3220 17233 17779 20091 3Kx3K 1 1 0 0 Slow DGrating G400L Clear 3330 16892 17924 20087 Full 1 1 0 0 Slow DPrism P450L Clear 3380 16933 17847 20324 4Kx3K 1 1 0 0 Slow DAcquire Flat g_sdss 3220 17233 17779 20091 3Kx3K 2 2 0 0 Fast | # Direct-Mode Presets # Imaging Flat Any 3020 17083 17861 20159 3Kx3K 1 1 0 0 Slow Grating G400L Clear 3150 16767 18004 20163 Full 1 1 0 0 Slow Prism P450L Clear 3180 16806 17920 20380 4Kx3K 1 1 0 0 Slow Acquire Flat g_sdss 3020 17083 17861 20159 3Kx3K 2 2 0 0 Fast # # Dual-Mode Presets # DImaging Flat Any 3220 17254 17775 20074 3Kx3K 1 1 0 0 Slow DGrating G400L Clear 3330 16919 17920 20065 Full 1 1 0 0 Slow DPrism P450L Clear 3380 16958 17847 20300 4Kx3K 1 1 0 0 Slow DAcquire Flat g_sdss 3220 17254 17775 20074 3Kx3K 2 2 0 0 Fast |
mods1 rconfig.tab | # Direct-Mode Presets # Imaging Flat Any 1200 16138 14731 12535 3Kx3K 1 1 0 0 Slow Grating G670L GG495 1650 16172 14793 12448 Full 1 1 0 0 Slow Prism P700L GG495 1550 16117 14806 12492 4Kx3K 1 1 0 0 Slow Acquire Flat r_sdss 1250 16138 14731 12535 3Kx3K 2 2 0 0 Fast # # Dual-Mode Presets # DImaging Flat Any 1160 16089 14759 12555 3Kx3K 1 1 0 0 Slow DGrating G670L Clear 1650 16116 14809 12479 Full 1 1 0 0 Slow DPrism P700L GG495 1550 15723 14511 12182 4Kx3K 1 1 0 0 Slow DAcquire Flat r_sdss 1160 16089 14759 12555 3Kx3K 2 2 0 0 Fast | # Direct-Mode Presets # Imaging Flat Any 1200 16128 14725 12551 3Kx3K 1 1 0 0 Slow Grating G670L GG495 1650 16181 14784 12447 Full 1 1 0 0 Slow Prism P700L GG495 1550 16121 14789 12505 4Kx3K 1 1 0 0 Slow Acquire Flat r_sdss 1250 16128 14725 12551 3Kx3K 2 2 0 0 Fast # # Dual-Mode Presets # DImaging Flat Any 1160 16075 14756 12571 3Kx3K 1 1 0 0 Slow DGrating G670L Clear 1650 16120 14805 12479 Full 1 1 0 0 Slow DPrism P700L GG495 1550 15737 14488 12191 4Kx3K 1 1 0 0 Slow DAcquire Flat r_sdss 1160 16075 14756 12571 3Kx3K 2 2 0 0 Fast |
mods2 bconfig.tab | # Direct-Mode Presets # Imaging Flat Any 985 26293 19651 27372 3Kx3K 1 1 0 0 Slow Grating G400L Clear 1245 26277 19503 27537 Full 1 1 0 0 Slow Prism P450L Clear 1138 26190 19534 27334 4Kx3K 1 1 0 0 Slow Acquire Flat g_sdss 940 26293 19651 27372 3Kx3K 1 1 0 0 Slow # # Dual-Mode Presets # DImaging Flat Any 1225 26456 19575 27286 3Kx3K 1 1 0 0 Slow DGrating G400L Clear 1525 26370 19327 27362 Full 1 1 0 0 Slow DPrism P450L Clear 1450 26360 19451 27245 4Kx3K 1 1 0 0 Slow DAcquire Flat g_sdss 1225 26456 19575 27286 3Kx3K 1 1 0 0 Slow | # Direct-Mode Presets # Imaging Flat Any 985 26529 19586 27201 3Kx3K 1 1 0 0 Slow Grating G400L Clear 1245 26525 19445 27347 Full 1 1 0 0 Slow Prism P450L Clear 1138 26433 19435 27190 4Kx3K 1 1 0 0 Slow Acquire Flat g_sdss 940 26293 19651 27372 3Kx3K 1 1 0 0 Slow # # Dual-Mode Presets # DImaging Flat Any 1225 26692 19510 27115 3Kx3K 1 1 0 0 Slow DGrating G400L Clear 1525 26617 19269 27173 Full 1 1 0 0 Slow DPrism P450L Clear 1450 26605 19350 27100 4Kx3K 1 1 0 0 Slow DAcquire Flat g_sdss 1225 26456 19575 27286 3Kx3K 1 1 0 0 Slow |
mods2 rconfig.tab | # Direct-Mode Presets # Imaging Flat Any 450 23113 17403 19382 3Kx3K 1 1 0 0 Slow Grating G670L GG495 861 23001 17453 19443 Full 1 1 0 0 Slow Prism P700L GG495 800 23121 17496 19344 4Kx3K 1 1 0 0 Slow Acquire Flat r_sdss 450 23113 17403 19382 3Kx3K 1 1 0 0 Slow # # Dual-Mode Presets # DImaging Flat Any 450 23108 17404 19387 3Kx3K 1 1 0 0 Slow DGrating G670L Clear 861 22994 17453 19451 Full 1 1 0 0 Slow DPrism P700L GG495 825 23109 17500 19350 4Kx3K 1 1 0 0 Slow DAcquire Flat r_sdss 450 23108 17404 19387 3Kx3K 1 1 0 0 Slow | # Direct-Mode Presets # Imaging Flat Any 450 23272 17397 19229 3Kx3K 1 1 0 0 Slow Grating G670L GG495 861 23171 17446 19280 Full 1 1 0 0 Slow Prism P700L GG495 800 23282 17495 19184 4Kx3K 1 1 0 0 Slow Acquire Flat r_sdss 450 23272 17397 19229 3Kx3K 1 1 0 0 Slow # # Dual-Mode Presets # DImaging Flat Any 450 23266 17399 19233 3Kx3K 1 1 0 0 Slow DGrating G670L Clear 861 23164 17448 19286 Full 1 1 0 0 Slow DPrism P700L GG495 825 23109 17500 19189 4Kx3K 1 1 0 0 Slow DAcquire Flat r_sdss 450 23266 17399 19233 3Kx3K 1 1 0 0 Slow |
Images mods*.20190521.0014-19 . locks look good. Changes all within +/-2