Service Observer: Jenny

Telescope Operator: DGH

Plan: Hopefully LBTI (which is not logged here) but iff not, closed dome checkouts.

Summary:

Issues:

Weather: A few clouds, winds are dying down, humidity pegged

Overview:

02:20 Unable to ssh to adsec or lbti wfs machines. We are able to ping them though. Tried skipping alias and directly ssh’ing to ip, waiting but connection closed by machine.

02:39 called Stephen who heroically stepped in and helped troubleshoot

(insert various troubleshooting efforts here)

03:19 Stephen is going to call us back after investigating some more.

03:25 Working on bringing MODS up. Looks like comtrollers need restarting. I’m just going to bring things up cleanly from scratch.

03:43 Stephen has some ideas! And solved. Logged in as root, adjust sshd_config with some commands he provided. Happy!

03:50 Amali is bringing up adsecs, I’m working on MODS.


MODS

04:30 Ilya is having hte same problem but with ssh, so did the same sort of thing to that machine as we did to adsec and wfs. Can ssh to it now.

05:00. MODS is finally up. Brought up MODS2 software. I ended up restarting the comtrollers so started from scratch.

-Started the cronjob for MODS2 and also started up the MODS2 portion of the ISp daily report.

-Note that on the Post Shutdown page, the commands isisCmd --mods1 m1.ie agc and isisCmd --mods1 m1.ie wfs

-Should be isisCmd --mods1 m1.ie util agc and isisCmd --mods1 util m1.ie wfs

Checkout

  1. mods2ColdStart.pro script
    • the 'agw reset' failed several times. Possible syntax error? Skipped that step. Restarted the AGw processed and moved the probe manually 'grpobe 0 -100' as you suggested and it moved fine. Homed. mods2ColdStart success
  2. From the GUI stepping through all configurations
    • Blue Imaging Grating Prism ok
    • Red Imaging Grating Prism ok
    • Blue filters 8 ok
    • Red filters 8 ok
    • Blue-Only Imaging ok Grating ok Prism ok
    • Red-Only Imaging ok Grating ok Prism ok
    • Dual Imaging ok Grating ok Prism ok
    • Hatch Open Closed ok
    • Calibration In Out ok
    • Mode Observing Calibration ok
    • Home AGW ok
  3. SieveSnap with both.
    • mods*.20190521.0001 Looks good
  4. David moved telescope to 60deg, LDG 207, RDG 195
  5. The imcsTTFs.pro actually in the Dual directory
    • cd ~MODSeng/modsScripts/Support/Dual
    • Running the imcsTTFs.pro script
    • mods*.20190521.0002-7
    • Mods2 took about 4 minutes longer than mods1 to complete the script.
    • Changes summarized in table below
    • The numbers obtained for colttfa colttfb colttfc were all fairly close except for DGrating for MODS2. I expected to see a difference of ~150 looking at the other numbers. But this one was 1150 off. I backed up the b & rconfig.tabs and filled in the new numbers. I reran the imcsTTFs.pro.
    • Images mods*.20190521.0008-13
    • The numbers achieved match what are in the r&b.conf files pretty much which is what I would expect. I did step away for a quick sec and missed locking for dual grating. Although I could just run this mode I'm reruning the imcsTTFs once more.

OLD VALUES

NEW VALUES

mods1 bconfig.tab

# Direct-Mode Presets

#

Imaging Flat Any 3020 17062 17865 20176 3Kx3K 1 1 0 0 Slow

Grating G400L Clear 3150 16746 18011 20177 Full 1 1 0 0 Slow

Prism P450L Clear 3180 16792 17921 20393 4Kx3K 1 1 0 0 Slow

Acquire Flat g_sdss 3020 17062 17865 20176 3Kx3K 2 2 0 0 Fast

#

# Dual-Mode Presets

#

DImaging Flat Any 3220 17233 17779 20091 3Kx3K 1 1 0 0 Slow

DGrating G400L Clear 3330 16892 17924 20087 Full 1 1 0 0 Slow

DPrism P450L Clear 3380 16933 17847 20324 4Kx3K 1 1 0 0 Slow

DAcquire Flat g_sdss 3220 17233 17779 20091 3Kx3K 2 2 0 0 Fast

# Direct-Mode Presets

#

Imaging Flat Any 3020 17083 17861 20159 3Kx3K 1 1 0 0 Slow

Grating G400L Clear 3150 16767 18004 20163 Full 1 1 0 0 Slow

Prism P450L Clear 3180 16806 17920 20380 4Kx3K 1 1 0 0 Slow

Acquire Flat g_sdss 3020 17083 17861 20159 3Kx3K 2 2 0 0 Fast

#

# Dual-Mode Presets

#

DImaging Flat Any 3220 17254 17775 20074 3Kx3K 1 1 0 0 Slow

DGrating G400L Clear 3330 16919 17920 20065 Full 1 1 0 0 Slow

DPrism P450L Clear 3380 16958 17847 20300 4Kx3K 1 1 0 0 Slow

DAcquire Flat g_sdss 3220 17254 17775 20074 3Kx3K 2 2 0 0 Fast

mods1 rconfig.tab

# Direct-Mode Presets

#

Imaging Flat Any 1200 16138 14731 12535 3Kx3K 1 1 0 0 Slow

Grating G670L GG495 1650 16172 14793 12448 Full 1 1 0 0 Slow

Prism P700L GG495 1550 16117 14806 12492 4Kx3K 1 1 0 0 Slow

Acquire Flat r_sdss 1250 16138 14731 12535 3Kx3K 2 2 0 0 Fast

#

# Dual-Mode Presets

#

DImaging Flat Any 1160 16089 14759 12555 3Kx3K 1 1 0 0 Slow

DGrating G670L Clear 1650 16116 14809 12479 Full 1 1 0 0 Slow

DPrism P700L GG495 1550 15723 14511 12182 4Kx3K 1 1 0 0 Slow

DAcquire Flat r_sdss 1160 16089 14759 12555 3Kx3K 2 2 0 0 Fast



# Direct-Mode Presets

#

Imaging Flat Any 1200 16128 14725 12551 3Kx3K 1 1 0 0 Slow

Grating G670L GG495 1650 16181 14784 12447 Full 1 1 0 0 Slow

Prism P700L GG495 1550 16121 14789 12505 4Kx3K 1 1 0 0 Slow

Acquire Flat r_sdss 1250 16128 14725 12551 3Kx3K 2 2 0 0 Fast

#

# Dual-Mode Presets

#

DImaging Flat Any 1160 16075 14756 12571 3Kx3K 1 1 0 0 Slow

DGrating G670L Clear 1650 16120 14805 12479 Full 1 1 0 0 Slow

DPrism P700L GG495 1550 15737 14488 12191 4Kx3K 1 1 0 0 Slow

DAcquire Flat r_sdss 1160 16075 14756 12571 3Kx3K 2 2 0 0 Fast



mods2 bconfig.tab

# Direct-Mode Presets

#

Imaging Flat Any 985 26293 19651 27372 3Kx3K 1 1 0 0 Slow

Grating G400L Clear 1245 26277 19503 27537 Full 1 1 0 0 Slow

Prism P450L Clear 1138 26190 19534 27334 4Kx3K 1 1 0 0 Slow

Acquire Flat g_sdss 940 26293 19651 27372 3Kx3K 1 1 0 0 Slow

#

# Dual-Mode Presets

#

DImaging Flat Any 1225 26456 19575 27286 3Kx3K 1 1 0 0 Slow

DGrating G400L Clear 1525 26370 19327 27362 Full 1 1 0 0 Slow

DPrism P450L Clear 1450 26360 19451 27245 4Kx3K 1 1 0 0 Slow

DAcquire Flat g_sdss 1225 26456 19575 27286 3Kx3K 1 1 0 0 Slow



# Direct-Mode Presets

#

Imaging Flat Any 985 26529 19586 27201 3Kx3K 1 1 0 0 Slow

Grating G400L Clear 1245 26525 19445 27347 Full 1 1 0 0 Slow

Prism P450L Clear 1138 26433 19435 27190 4Kx3K 1 1 0 0 Slow

Acquire Flat g_sdss 940 26293 19651 27372 3Kx3K 1 1 0 0 Slow

#

# Dual-Mode Presets

#

DImaging Flat Any 1225 26692 19510 27115 3Kx3K 1 1 0 0 Slow

DGrating G400L Clear 1525 26617 19269 27173 Full 1 1 0 0 Slow

DPrism P450L Clear 1450 26605 19350 27100 4Kx3K 1 1 0 0 Slow

DAcquire Flat g_sdss 1225 26456 19575 27286 3Kx3K 1 1 0 0 Slow



mods2 rconfig.tab

# Direct-Mode Presets

#

Imaging Flat Any 450 23113 17403 19382 3Kx3K 1 1 0 0 Slow

Grating G670L GG495 861 23001 17453 19443 Full 1 1 0 0 Slow

Prism P700L GG495 800 23121 17496 19344 4Kx3K 1 1 0 0 Slow

Acquire Flat r_sdss 450 23113 17403 19382 3Kx3K 1 1 0 0 Slow

#

# Dual-Mode Presets

#

DImaging Flat Any 450 23108 17404 19387 3Kx3K 1 1 0 0 Slow

DGrating G670L Clear 861 22994 17453 19451 Full 1 1 0 0 Slow

DPrism P700L GG495 825 23109 17500 19350 4Kx3K 1 1 0 0 Slow

DAcquire Flat r_sdss 450 23108 17404 19387 3Kx3K 1 1 0 0 Slow



# Direct-Mode Presets

#

Imaging Flat Any 450 23272 17397 19229 3Kx3K 1 1 0 0 Slow

Grating G670L GG495 861 23171 17446 19280 Full 1 1 0 0 Slow

Prism P700L GG495 800 23282 17495 19184 4Kx3K 1 1 0 0 Slow

Acquire Flat r_sdss 450 23272 17397 19229 3Kx3K 1 1 0 0 Slow

#

# Dual-Mode Presets

#

DImaging Flat Any 450 23266 17399 19233 3Kx3K 1 1 0 0 Slow

DGrating G670L Clear 861 23164 17448 19286 Full 1 1 0 0 Slow

DPrism P700L GG495 825 23109 17500 19189 4Kx3K 1 1 0 0 Slow

DAcquire Flat r_sdss 450 23266 17399 19233 3Kx3K 1 1 0 0 Slow



Images mods*.20190521.0014-19 . locks look good. Changes all within +/-2

  • 6) Running MODS focus scripts found in ~modseng/modsScripts/Testing/MODSfocus
    • There were 2 options for dualgr2 but based on config files the first version seemed the best. IF time I'll run v2.
    • 1) dualgr1.pro mods1*.20190521.0020-30 . red from 1500 to 1800, blue from 3070 to 3370
      • dualgr2.pro mods2*.20190521.0020-30 , red from 711 to 1011, blue from 1375 to 1675
    • 2)dualim1.pro mods1*.20190521.0031-41 . red from 1010 to 1310, blue from 3180 to 3480
      • dualim2.pro mods2*.20190521.0031-41 , red from 300 to 600, blue from 1075 to 1375
    • 3)dualpr1.pro mods1*.20190521.0042-52 . red from 1400 to 1700, blue from 3230 to 3530
      • dualpr2.pro mods2*.20190521.0042-52 , red from 675 to 975, blue from 1300 to 1600
    • 4)redim1.pro mods1r.20190521.0053-63 . red from 1050 to 1350
      • redim2.pro mods2r.20190521.0053-63 . red from 300 to 600
    • 5) redigr1.pro mods1r.20190521.0053-63 . red from redgr2.pro mods2r.20190521.0053-63 . red from
    • 6) redire1.pro mods1r.20190521.0064-74 . red from
      • redpr2.pro mods2r.20190521.0064-74 . red from
LBTI needs to do some things, and I need to shift focus. Blue focus to be run later.

Leaving MODS in configuration for Daywork:
  • Mods sleep
  • slitmask out
  • calib out
  • agw home
  • dichroic 3 (should be blue-only)


LUCI1

  1. While taking focus data, going to do functional checkout of LUCI1. Bringing up GEIRS still takes a very long time without the network.
  2. All mechanisms for LUCI1 are unknown. Init failed with timeout. MCE on yet?
  3. Unable to ssh to luci.luci.lbto.org, but I can ping it. Same as the computers earlier in the night so checking if its the same thing….and it worked.
  4. MCE was off via the webIO. Turned on. Init all units successful.
  5. All Using The IMGUI - Will use eng if things go amiss.
    • Move FW1 Positive: +10 moving from Jlow to JHigh, + 10 moving H2 to HeI, no other additional steps
    • Move FW1 Negative: -10 steps moving H2 to HeI, no other additional steps
    • Move FW2 Positive: +10 steps from Free06 to Ks, +10 from K to HKspec, no other additional steps
    • Move FW2 Negative: no additional steps
    • Moving Camera: N1.8 ok, N30 ...
    • Error while moving to the N30. 3 additional steps of 10 but not found. Init back to N375 and resent to N30. No additional steps this time.
    • Moved to N375 and 3 additional steps of -10, failed to reach N375
    • Initialized and it took another 3x(-10) steps to reach the N375.
    • Moving to n1.8 ok, to N375 ok, to N30 +2x(10) additional steps but ok, to N375 ok.
    • Move Grating: G210 Tilt 2.45 & 2.105, G200 1.53 & 2.46, G150 2.025 & 2.34, back to mirror
  6. Before moving the mask to the FPU I might check pupil alignment. Need to wait for LN guys to finish so I can put appropriate lights on.
  7. Pupil and Fieldstop alignment:
    • David is Authorizing LUCI. Both rotators at their park positions, low dome lights on. COllimated M2’s
    • Taking Pupil Image: N1.8 J PVlens Pupil viewer luci1.20190521.0001
    • Field Stop image - moved in the N30Field stop, N375 J luci1.20190521.0002
    • From pupil image:
      • Cold stop: 1208.8 1246.84
      • Plug: 1214.1584 1278.9902
      • Plug to coldstop -5.358 -32.150
      • From FS image
      • 1103.4929 1156.3584
      • FS to center of detector: -79.493, -132.3584
      • Scale dXi and dYi to N180 pixels: dXi dYi
        • Original imaging pixel offsets: -79.49 -132.36 (N375)
        • Offsets scaled to N180 pixels: -37.47 -62.39
        • For these N180 camera pixel offsets:
        • dXimg dYimg dXpup dYpup
        • -37.47 -62.39 -5.36 -32.15
      • Motor offsets to align both the Pupil and FieldStop are:
        • FM1m1 FM1m2 FM4m1 FM4m2
        • -11200 -3279 -12970 13812
      • Moving FM1m1 -11200
      • Moving FM1m2 -3279
      • Moving FM4m1 -12970
      • Moving FM4m2 13812
      • From FS image
        • 1014.3623 1024.4276
      • FS to center of detector: 9.6377, -0.4276
      • From pupil image:
        • Cold stop: 1130.1562 1123.0171
        • Plug: 1133.1703 1125.0265
        • Plug to coldstop -3.0141, -2.0094
    • Round 2
      • Scale dXi and dYi to N180 pixels dXi dYi
        • Original imaging pixel offsets: 9.64 -0.43 (N375)
        • Offsets scaled to N180 pixels: 4.54 -0.20
      • For these N180 camera pixel offsets
      • dXimg dYimg dXpup dYpup
        • 4.54 -0.20 -3.01 -2.01
      • Motor offsets to align both the Pupil and FieldStop are:
        • FM1m1 FM1m2 FM4m1 FM4m2
        • -354 -57 -134 -1007
    • Taking Pupil Image: N1.8 J PVlens Pupil viewer mask in turnout luci1.20190521.0005
    • Field Stop image - moved in the N30Field stop, N375 J luci1.20190521.0006
    • From pupil image: aligned! Plug = coldstop
    • From FSimage center at 1023.1915 1024.6028, good enough!!
    • Field Stop image - moved in the N30Field stop, N375 J luci1.20190521.0003
    • Taking Pupil Image: N1.8 J PVlens Pupil viewer mask in turnout luci1.20190521.0004

-transcribed from Google docs: https://docs.google.com/document/d/14lB5TkhGhOgonHYTFau6BIOuAwm-70oBH0WP2ILNnSU/edit

-- BarryRothberg - 21 May 2019
Topic revision: r1 - 21 May 2019, BarryRothberg