D-Time UT Jan 08, 2019
OSA: S. Allanson
ISA: B. Rothberg
ISp: E. Solheid
Mtn Manager: P. Hartley
Night Center 00:26 - Handover to occur at 00:21 from LBTI
Plan: MODS-Bino at start
Highlights:
Completed 2/3 Wagner targets
Completed 1" MOS Mask for Praesepe (O. Kuhn)
Completed 1 QSO LS (Rothberg)
Completed 3 Asteroid Targets 2018VR, 2018VR5, 2018ET2 w/LBC-Red (Veillet)
Wagner Program
UT 07:32 - heading to pointing star - seeing as 1.3-1.6" at handover
UT 07:39 - 0.8-0.9" on DIMM
UT 07:42 - running with 0.8" script for v392per
UT 07:49 - nudge MODS-1 over + 2 pix +0.25", MODS-2 nudge -0.13" (bit more than 1pix), nudged back MODS-1 -0.13" - MODS-2 is spot on
UT 07:50 - starting spectroscopy
M1R 0006-0008
M1B 0002-0004
M2R 0006-0008
M2B 0002-0004
- first spectra look good, can see emission lines
UT 08:07 - DIMM 0.77" Guiders 0.60" on WFS
UT 08:18 - powering up LBC-Red for later
UT 08:29 - completed v392per
UT 08:30 - moving to v959mon
UT 08:37 - MODS1-R slow readout, MODS-2 bang on, nudging MODS-1 over by -0.123"
UT 08:42 - MODS-1 bang on, starting spectroscopic script v959mon
M1R 0013-0015
M1B 0005-0007
M2R 0012-0014
M2B 0005-0007
UT 08:50 - DIMM 0.68" WFS 0.70"
UT 09:07 - first exposures out, can see emission lines - looking at SX guider in LBTtools - definitely have clouds passing over us
UT 09:49 - completed v959mon
UT 09:50 - moving to Feige 34
UT 09:58 - had to tweak alignment again with modsAlign -r
UT 09:59 - starting spectroscopy
UT 10:13 - completed Feige 34
M1R 0018-0020
M1B 0008-0010
M2R 0017-0019
M2B 0008-0010
UT 10:13 - sending Praesep MOS mask acquisition script
UT 10:27 - alignment complete - looks good both sides - starting spectroscopic observations
M1R 0024-0026
M1B 0011-0013
M2R 0023-0025
M2B 0011-0013
DIMM 0.6" WFS on both sides 0.47"
UT 11:05 - finished Praesepe 1"slit MOS mask
UT 11:06 - moving to Rothberg QSO (PG1202+281)
UT 11:15 - MODS1-R again slow readout
-since MODS1 so slow, MODS-2 script started first with execMODS --mods2
-MODS1-R readout again slow
UT 11:24 - starting MODS1 spectroscopy (its 2 minutes behind)
M1R 0027-0031
M1B 0014-0015
M2R 0026-0030
M2B 0014-0015
DIMM 0.9" WFS 0.48-0.50"
taking an extra 900sec exposure on each side
UT 12:01 - WFS 0.6"
UT 12:09 - WFX 0.51-0.53"
Veillet Program
UT 12:15 - Reconfiguring for LBC-Red on DX
UT 12:30 - sending focus script for 2018 VR5
UT 12:34 - running dohybrid
UT 12:40 - converged, sending non-sidereal override for 2018 VR5 (5 exp x 120 sec no dither)
UT 12:44 - DIMM 0.92"
UT 12:53 - finished 2018 VR5
UT 12:54 - slewing to focus field for 2018 ET2
UT 12:59 - slewing to 2018 ET2 (5exp x 120 sec no dither)
UT 13:14 - finished 2018 ET2
-moving to focus field for 2018 VR
UT 13:30 - moivng to 2018 VR
UT 13:35 - finished 2018VR - closing up to take cals
UT 13:45 - Bino-MODS Dual Grating Arc lamps
UT 13:55 - Bino-MODS Dual Grating slitless pixel flats
UT 13:59 - taking 10 LBC-Red Biases
UT 14:03 - powering off LBC-Red
UT 14:19 - Bino-MODS Dual Grating 0.8" slitflats
UT 14:41 - MODS put to sleep (will need to finish Praesepe cals and biases later)
--
BarryRothberg - 08 Jan 2019