UT November 29, 2018
ARGOS/Eng LBTO Technical Night
OSA: D.G. Huerta
ISp: E. Solheid
ISA: B. Rothberg (Tucson)
ARGOS AO: J. Power, S. Walsh
Laser Dude: G. Rahmer
Software Support: A. Colson (Tucson)
Mtn Manager: P. Hartley
Summary:
ARGOS Eng - completed tests on-sky, including measuring a pupil wobble by taking images at multiple positions along 0.25" slit
Eng Tasks Accomplished -
1. spectrophotometric standard in all modes
2. photometric imaging field - dual imaging for MODS mask pre-imaging (also test of
MODS2R)
3. MODS-Bino AGW Transform data collection/confirmation - however, only ~10 stars were obtained as conditions rapidly deteriorated
4. Test of MODS2-Red in real science longslit spectroscopy - 30min exposure - worked - but resulted in a red grating fault (see IT 7496)
5. Observed 1 backup poor condition program QSO (MODS-1 Dual, MODS-2 Blue)
--MODS2 Red is currently unavailable again.
--Updated MODS2 rotator zeropoint, and MODS 1 & 2 new transforms are still active from AGW transform collection
Backup Eng Taak To-Do List:
1. MODS-2 Red on-sky checkout
a/ a spectrophotometric standard in all modes (if time is a factor, then I'll skip blue-only modes),
b/ a photometric imaging field (or any sdss field, but I have scripts for a couple of fields with photometry from Clem et al or Stetson)
c/ the Praesepe field, which has 5 or 6 stars with ZYJHK from UKIDSS and sdss ugriz photometry, and which would serve as a pre-image for a mask, thereby avoiding the limitations of using a catalog and autoslit.
3. MODS-Bino AGW Transform data collection/confirmation
4. MODS pointing, LUCI pointing
5. Test monocular MODS blind offset - make sure script engine update is working
6. ESM/SL Comparison
UT 01:13 - LUCI GUIs running, init all run on both
UT 01:14 - AO checkout in-progress
UT 01:22 - com drop out from mountain? - my NX session stopped but polycom was fine...turns out it was Olga...
UT 01:29 - AO checout abandoned....going straight to ARGOS
UT 01:32 - DIMM 1.52" - authroizing LUCI-1 SL / LUCI-2 ARGOS
UT 01:37 - network drop out from mountain
UT 01:39 - test darks LUCIs
L1 - 0001-0002 2.51sec test dark
L2 - 0003-0004 2.51sec test dark
UT 01:53 - network drop out from mountain
UT 01:57 - Sending collimation script for M52
UT 02:00 - DX side missed on target acquisition
UT 02:06 - pointing check - I updated the collimation star to a brighter one closer in the ARGOS patrol field
UT 02:11 - firing lasers
UT 02:17 - stopping lasers for plans
UT 02:18 - resuming lasers, sending L1/SL + L2/ARGOS preset
UT 02:49 - lots of planes going by, working on pupils with ARGOS AO system
UT 03:04 - satellite closure for 3 min + airplanes after - seeing hitting 2"
UT 03:18 - 2.5" on the DIMM
UT 03:24 - taking test images DIMM 1.93" Gain 1.0, 0.2, 0
L1 0003 - 2.51sec x 13 NDIT K
L2 0005 - 2.51sec x 13 NDIT K
UT 03:31 - airplane flew through
L1 0004 - IGNORE
L2 0006- IGNORE (this would represent no corrections)
UT 03:33 - network drop out from mountain
UT 03:35 - DIMM 1.74" Gain 1.0, 0.3, 0
L1 0005 ; L2 0007
UT 03:38 - Closure for planes
UT 03:42 - no satellite closures for 1hr 16min
UT 03:45 - Gain 1.0, 0.4, 0 DIMM 1.58"
L1 0006 ; L2 0008
UT 03:48 - Gain 1.0, 0.5, 0 DIMM 1.42" - got ripples
L1 0007 ; L2 0009 - IGNORE
UT 03:49 - Gain 1.0, 0.4, 0.05 DIMM 1.5" - ripples
L1 0008 ; L2 0010
UT 03:51 - Gain 1.0, 0.4, 0.1 DIMM 1.37"
L1 0009 ; L2 011 - L2 images look squashed (elliptical) wider in X than Y by ~1-1.2pixels
UT 03:57 - Airplane and RIP during GAIN setting
UT 03:58 - unleashing the light upon the sky
UT 04:03 - Gain 1.0, 0.4, 0.1 DIMM 1.6"
L1 0010 ; L2 0012
LUCI2 images show streaks through stars - looks like mini Saturns
UT 04:05 - Gain 1.2, 0.2, 0.1 DIMM 1.76"
L1 0011 ; L2 0013
LUCI2 images shows elongation and one 2.51sec read shows double stars
UT 04:11 - Gain 1.2, 0.2, 0.1 DIMM 1.15"
L1 0012 ; L2 0014
LUCI2 images shows elongation and one 2.51sec read shows double stars
Changing savemode to CUBE
UT 04:17 - Gain 1.2, 0.2, 0.1 DIMM 1.20"
L1 0013 ; L2 0015
UT 04:19 - RTD2 - LUCI2 had to reset all and restart
UT 04:21 - Gains 1.2, 0.2, 0.05
L1 0014 ; L2 0016
LUCI2 shows double stars - can see in cube first read is OK, then it jumps left ~30 pixels (~3.57")
UT 04:43 - DIMM 0.84" 1.2, 0.2, 0.05
L1 0015 ; L2 0017 -LOST AOS (sub-system died) and an airplane
UT 04:46 -- Reauthorizing LUCI2 only - putting blinds in LUCI-1
-pointing check
UT 04:55 - sending M52 L2 only collimation script
UT 04:58 - powering on lasers
UT 05:03 - Facsum shows -+2147483648 for RA Dec HA
GCS right - guidestar flew off
UT 05:05 - preset to science field cleared weird numbers
acetrack failed since lasers were off, powering on lasers again
UT 05:07 - resending M52 science preset
UT 05:11 - ARGOS arbitrator disconnected, AOS crashed
L2 0018 looked OK, 0019 - arbitrator failed - can see poor image quality
LUCI2 reporting can't get rotator angle and elevation
back to FACSUM showing -+2147483648 for RA Dec HA - also in IIFGUI
-Calling Petr Kubanek - no answer
UT 05:25 - restarted PCS - fixed most of the issues (HA is still odd)
UT 05:26 - resendnig ARGOS collimation script for M52
UT 05:30 - AOS died again
-called Stephen Hooper
-shell set
UT 05:37 - resending preset
Arbitrator died
UT 05:43 - still holding on techincal issues
UT 05:47 - resending collimation ARGOS script for M52
UT 05:51 - sending science preset
UT 05:53 - LUCI-2 FW1 error - eng GUI - initizalized and manually moved to correct filter, failed again, initiazlied again
UT 05:54 - resending ARGOS science preset
UT 05:58 - says Clear + K - but looks like its the blind filter in FW1 L2 0020-0021
UT 05:59 - network drop out from mountain
L2 0022 - test - watchied numbers move in MCU - recovered
UT 06:05 - Put TT 1.1 Lo 0.3 & Ho 0.05 . Ripples immediately and rip Got ripples on
AdSec
UT 06:10 - looks like it grabbed the wrong AO Ref star - system reports multiple stars and the one it grabbed was R=13. AORef star is R=10.7 (and there are no clouds and seeing is better now)
UT 06:16 - L2 0023 - test exposure 2.51sec x 13 NDIT CUBE K filter
UT 06:21 - System Status shows AO DX cooling flow low
UT 06:31 - going to try Georgiev's G1 script
UT 06:39 - sent collimation script
UG 06:42 - sent science script (LS acquisition)
- preset failed due to airplane
UT 06:45 - resending science preset
Gains 1.1,0.2,0.0
UT 06:52 - -resending preset since LUCI GUI showed an error in preset but ARGOS had closed loops
Had to offset +0.12" in DETX to nudge star into slit - centerd at Y=1030 in slit (G1)
0028 - aligned in slit
checking pupil wobble by dithering up and down in slit with mirror
0029 - +20" DETY star is in upper segment (one above central segment) galaxy is at top of central segment - might be too much
0030 - -15" DETY - both look to be in segment
0031 - +15" DETY
0032 - 0" DETY
0033 - -43" DETY (first offset in Iskren's script) - moved to segment below central segment - star might be out of slit
0034 - +1" DETY (second offset - looks good)
0035 - +43" DETY - looks slightly out of slit (star)
0036 - -42" DETY - (4th offset in script)
0037 - +5" DETY (9th offset in script)
0038 - -36" DETY (23rd offset in script)
0039 - +36" DETY
0040 - 0"DETY
0041 - +40" DETY
0042 - -5" DETY
UT 07:38 - playing with gains
UT 07:47 - putting mask in turnout to take some images
0043 - cube image 2.51 x 10 H-band
0044 - test cube image 2.51 x 10 H-band
L2 0024-0044 - (0029-0042 wobble test along slit)
UT 07:57 - finished with Iskren's target
07:58 - handing over to LBTO Eng, reconfiguring for Binocular MODS, putting LUCIs into safe setup
Plan is to observe full complement of specphotstds and imaging for a mask, test science image spectra possible
UT 08:27 - sending preset for g191b2b
UT 08:36 - starting spectroscopy all modes MODS1 & 2 for G191b2b
-there are some clouds in all-sky near standard
UT 09:26 - completed G191b2b script
UT 09:27 - sending preset for Praesepe imaging
UT 09:47 -
MODS1R on the last exposure is taking a long time to read out exposure
UT 09:48 - now reading out OK
M1B 0014-0017
M1R 0017-0022
M2B 0113-0116
M2R 0116-0121
UT 09:50 - Moving to Arp 187
UT 09:53 - caught the wrong star on MODS2, doing a pointing check
UT 09:57 - resending preset
UT 10:01 -
MODS2R IMCS lock fail, but retry worked
UT 10:04 -
MODS2R seemed to skip the acquisition thru slit and just take the field image, manually taking it now
headers all screwed up, but last two manual exposures of 10sec worked
UT 10:15 - RGRATING =1 move fault, move 1 but requested position 2, hit Retry
UT 10:16 - fault on retry, cleciked Imaging, OK, clicked Grating...OK
UT 10:19 - red IMCS lock failed, hit retry OK
-i swear i'm not trying to break MODS2-Red....
DIMM 1", WFS 1.3"
M1B 0018
M1R 0023-0026
M2B 0117 - stopped 179s short
M2R 0122-0127 stopped 178s short
UT 10:49 - moving to Stone_E - just at 29.5
AdSec limit,
UT 10:51 - used RS instead of TS in preset, resending - worked
UT 10:56 - i think i RIP'd DX - I think maybe SX too....(next on my learn how to fix list...)
-both shell set
UT 10:59 - clouds really rolling in.....don't think transform is doable - However, Olga found the missing piece of the puzzle
1. Update AGW.INI on mods1 and mods2 computers
2. Stop agw, Stop ie
3. Start age, start ie
4. PCSInstrunment.conf - make sure to update rotator zeropoint
5. Bounce PCS
6. run the transform init script to setup both MODS
7. Take your data
UT 11:03 - we're giving the transform a try - i'm updating PCS to Right Rotator ZP = 26.79, Olga is updating MODS transform sent by Doug M.
Ut 11:16 - bouncing PCS
UT 11:17 - running transformInit_PointingMask.pro
UT 11:18 R-grating error again - rgrating=2 move fault, positon at end of move 2 but requested position 1
- had this earlier
UT 11:20 - instconfig dual imaging not working on MODS2 - made a version for
M2Blue - running now
UT 11:27 - ran transform collect - got error co-pointing limit....
https://lbt.issuetrak.com/CSIssue_View.asp?IssueNbr=7218
UT 11:29 - resending initial binoc preset
UT 11:32 - starting transform_collect again DIMM 1.21"
M1R 0027 On Axis
M2B 0118 On axis
-stars are different in each one
UT 11:37 - need to do a pointing check - DX was in another zip code (in another state)
UT 11:43 - moving back to Stone E
Using Stone_Estar50bt_pa180.list
UT 11:59 - Olga is checking on MODS2-Red grating
M1R 0028 on axis
M2B 0120 on axis
M1R 0029 - BG
M2B 0121 - BG
M1R 0030 - GS1
M2B 0122 - GS1
M1R 0031 - GS2
M2B 0123 - GS2
M1R 0032 - GS3
M2B 0124 - GS3
M1R 0033 - GS5
M2B 0125 - GS5
M1R 0034 - GS6
M2B 0126 - GS6
M1R 0035 - GS7
M2B 0127 - GS7
M1R 0036 - GS8
M2B 0128 - GS8
M1R 0037 - GS9
M2B 0129 - GS9
M1R 0038 - GS11
M2B 0130 - GS11
M1R 0039 - GS12
M2B 0131 - GS12
M1R 0040 - GS13 - looks like offset from what it shoudl be
M2B 0132 - GS13 - looks like offset from what it should be
M1R 0041 - GS14 - looks correct
M2B 0133 - GS14 - looks wrong again
M2B 0134 - GS15 - looks blank - missed target
UT 12:25 - losing guidestar SX lost
UT 12:28 - both sides failed
UT 12:27 - trying to restart SX
Done with trasnform for tonight
M1R 0028-0039 GOOD
M2B 0120-0131 GOOD
UT 12:31 - attempting poor condition QSO target
UT 12:45 - lost guiding, but back
MODS1 offset into slit - 2pix -0.24 DET X, MODS2 looks good
M1R 0042-0047
M1B 0019-0020
M2B 0135-0139
UT 12:48 - com drop mountain
UT 12:50 - starting spectroscopy
I did not revert to the old MODS2 ZP or transforms for either MODS before taking this data....
UT 13:24 - finished 1800sec exposures, attempting a last 600sec - aborting earlier (94-120sec short)
UT 13:35 - closing dome...finishing up, putting MODS to sleep
--
BarryRothberg - 29 Nov 2018