UT Nov 02 2018

Eng Split Night with SOUL-Commissioning

Observers: O. Kuhn, B. Rothberg

OSA:. S. Allanson

ISp: J. Riedl

Mtn Manager: P. Hartley

Plan:

1. AGW transform StoneD with LUCI-1 and LUCI-2

2. AGW trasnform with MODS2 (and MODS1) with updated MODS2 rotator zeropoint

UT 03:07 - J. Hill updating the AGW Transform computed by D. Miller, will restart systems later and update PCS config with the measured rotator ZP uopdate to LUCI-1

UT 03:40 - G. Taylor is running ESM on DX to test and is saving the CCD WFS data (seeing is 1.8"-3")

UT 07:46 - telescope handed over to LBTO - PCS and GCSL have been bounced, heading to pointing star.

LUCI-Bino AGW Transform

luci1.20181101.0060 - 2.51 second dark

luci2.20181101.0034 - 2.51 second dark

UT 08:00 - sending binocular preset to StoneD

L1 0061 - 1st exposure, 62 off image

L2 0035 - 1st exposure, 36 off image

star L1 L2

GS4 0063 0037 PA=0

GS12 0064 0038

GS23 0065 0039

GS13 0066 0040

GS22 0067 0041

GS5 0068 0042

GS2 0069 0043

GS11 0070 0044

GS29 0071 0045

GS24 0072 0046

GS30 0073 0047

GS25 0074 0048

GS4 0075 0049 PA=15

every few images wfsc on DX is complainnig that .info file is not found (not occurring on SX)

GS12 0076 0050

GS23 0077 0051

GS13 0078 0052

GS22 0079 0053

GS17 0080 0054

UT 08:43 DIMM 1.36"

GS5 0081 0055

GS11 0082 0056

GS29 0083 0057

GS24 0084 0058

GS30 0085 0059

GS4 0086 0060 PA=30 - DX is ~2 stars behid SX

GS12 0087 0061

GS23 0088 0062

GS13 0089 0063

GS22 0090 0064

GS5 0091 0065

UT 09:00 collimation on DX struggling more - may explain why behind SX (DX still on 0060 or GS4) - z9/z10 ran away - Steve fixed it

GS11 0092 0066

GS29 0093 0067

GS24 0094 0068

GS20 0095 0069

ON-axis 0096 0070

UT 09:08 - SX Complate

20181102/lfbg/ Log for SX

20181102/rfbg/ Log for DX

UT 09:15 - Olga waking up MODS1/MODS2

MODS-Bino AGW Transform

UT 09:23 - putting LUCIs in safe mode - reconfiguring for MODS-Bino

UT 09:25 - Olga updating PCS Config to change the right rotator zeropoint, first making a backup copy PCSInstrument.20181102.conf, then changing to

Measured delta theta in September (during restart - see wiki page for 20180910) as 0.76, changing right rotator zeropoint to 26.79

UT 09:32 - restarting PCS

UT 09:45 - setting up MODS for 3Kx3K sloan g, 3seconds blue on both sides

UT 09:48 - sending binocular preset to StoneD

UT 09:52 - resending preset to GS0 in StoneD

starting filenames:

mods1b.20181102.0002

mods2b.20181102.0002

-config script homed AGW so we lost GS

-run script then send preset for transform

UT 09:58 -sending preset

UT 10:02 - starting transform collection

-copointing limit hit

changing list for GS0 to start

UT 10:10 - Running Stone_D_MODS.list from wfsc directory, 35 stars

UT 10:18 - star saturated so stopping, then going to change back to 1Kx1K for readout

starting on GS5 so have to set TS=5 in the preset via IDL, i.e. we wanted to start with GS5 instead of the too bright GS0
  • IDL> iif_preset, Stone_D, MODE=Active, GS=5, RS=5, PA=225, /RIGHT
  • IDL> iif_preset, Stone_D, MODE=Active, GS=5, RS=5, PA=225, /LEFT
  • iif_binoc_preset
then run trasnform collect

Added later (20181127) by OPK: list was Stone_D_star5_mrg.list, having 34 stars, and I believe that the syntax for the iif_preset commands use GS=5, TS=5, not GS=5, RS=5. RS refers to AO reference star.

M1R 0004 - first

M2B 0004 - first

Changing exposure times from 1R 1sec 2B 3sec to 5seconds for both sides

Changing exposure time on 2B from 5sec to 10sec so can better see holes

-remember to take a bias at the end of the script

mods1r 0009 GS 19 - star is off to the top left - perhaps got the wrong off-axis star

MODS1Red is reading out 3Kx3K, MODS2Blue is reading out 1Kx1K

mods1r 0023 - faint star in wrong spot - mods2b shows it OK

UT 12:07 - MODS2Blue completed

Taking biases on the blue side mods2b 0040-0044 biases

UT 12:22 - MODS-2 put to sleep

UT 12:26 - MODS1 done

taking 5 biases mods1r 0040-0044

UT 12:27 - closing up

Leaving the transform and upated LFBG rotator zeropoint in place

Reverting back to previous MODS-2 rotator zeropoint

-- BarryRothberg - 02 Nov 2018