Content: | Error to initialize the instrument unit server "rmi://localhost:60002/TWO_MOSUnit"! |
Attachment: | java.rmi.ServerException: RemoteException occurred in server thread; nested exception is: java.rmi.RemoteException: de.rub.astro.lucifer.instrument.sequence.PreConditionsViolatedException |
2018-09-13T02:26:17.003596+00:00 tcs1 LBT_GCSL: CamImage: createSubImageXY(70 131 249 310) 2018-09-13T02:26:17.010574+00:00 tcs1 LBT_GCSL: [D] WFS: spot grid 0 0: [3:15,3:16]UT 02:32 home AGW2 and resend the on-axis preset. DX pupil came back to the same place (perhaps only displaced by 0.75 lenslet rather than a full row). UT 02:38 ACTIVE preset off-axis KFP X=-0.2 Y=69.74 SX FWHM=1.5 DX FWHM=0.8 arcsec.
2018-09-13T02:40:13.654168+00:00 tcs1 LBT_GCSL: CamImage: createSubImageXY(70 145 249 324) 2018-09-13T02:40:13.669151+00:00 tcs1 LBT_GCSL: [D] WFS: spot grid 0 0: [3:15,3:15]UT 02:46 ACTIVE preset off-axis KFP X=0.1 Y=149.3 - DX grabbed the wrong guide star a fainter binary. (Interesting for seeing lenslet positions.) SX pupil shift is OK here on the guider Y-axis.
2018-09-13T02:48:46.684389+00:00 tcs1 LBT_GCSL: CamImage: createSubImageXY(70 158 249 337) 2018-09-13T02:48:46.696374+00:00 tcs1 LBT_GCSL: [D] WFS: spot grid 0 0: [3:15,3:16]UT 02:55 resending preset to correct the guide star UT 03:15 ACTIVE preset off-axis with PA rotated by +30 (after ACQUIRE for repointing) KFP X=+73.8 Y=129.8 grep GCSL /lbt/log/current.log | grep "createSubImageXY(" -A 2 Note that IDL and GCS on the SX side no longer agree on the left this is wfsc 0051. It must be a configuration problem as the DX side agrees. SX
=> Pupil Positioning: X Y X Y On-Axis Pupil = 159.70 214.76 159.70 214.76 Pupil Shift = 17.58 22.26 17.58 22.26 Shifted Pupil Center = 177.28 237.02 Outer Pupil Fit = 177.67 236.89 -------------- -------------- Pupil Center = 173.11 245.11 173.07 234.77DX
=> Pupil Positioning: X Y X Y On-Axis Pupil = 376.00 263.00 376.00 263.00 Pupil Shift = 17.58 -22.26 17.58 -22.26 Shifted Pupil Center = 393.58 240.74 Outer Pupil Fit = 396.31 247.75 -------------- -------------- Pupil Center = 397.99 245.20 397.99 245.2003:22 ACTIVE preset off-axis with PA rotated by -30 from original. PA=115 SX side runs away immediately in coma! KFP X=-75.5 Y=128.8 SX wfsc 0060
=> Pupil Positioning: X Y X Y On-Axis Pupil = 159.70 214.76 159.70 214.76 Pupil Shift = 17.58 22.26 17.58 22.26 Shifted Pupil Center = 177.28 237.02 Outer Pupil Fit = 177.90 235.27 -------------- -------------- Pupil Center = 173.11 245.11 173.07 234.77DX wfsc 0067
=> Pupil Positioning: X Y X Y On-Axis Pupil = 376.00 263.00 376.00 263.00 Pupil Shift = 17.58 -22.26 17.58 -22.26 Shifted Pupil Center = 393.58 240.74 Outer Pupil Fit = 394.13 246.68 -------------- -------------- Pupil Center = 397.99 245.20 397.99 245.20after the preset SX wfsc 0061
=> Pupil Positioning: X Y X Y On-Axis Pupil = 159.70 214.76 159.70 214.76 Pupil Shift = -17.96 21.96 -17.96 21.96 Shifted Pupil Center = 141.74 236.72 Outer Pupil Fit = 145.04 235.93 -------------- -------------- Pupil Center = 146.35 231.73 153.00 215.00DX wfsc 0068
=> Pupil Positioning: X Y X Y On-Axis Pupil = 376.00 263.00 376.00 263.00 Pupil Shift = -17.96 -21.96 -17.96 -21.96 Shifted Pupil Center = 358.04 241.04 Outer Pupil Fit = 358.11 247.40 -------------- -------------- Pupil Center = 357.85 245.69 357.85 245.6903:28 Clear ACTIVE optics on left, but image is still ugly. 03:33 ACTIVE preset on-axis
=> Pupil Positioning: X Y X Y On-Axis Pupil = 159.70 214.76 159.70 214.76 Pupil Shift = -7.41 14.14 -7.42 14.14 Shifted Pupil Center = 152.29 228.90 Outer Pupil Fit = 153.36 228.67 -------------- -------------- Pupil Center = 146.35 231.73 146.45 230.99-image quality is so bad, can't see the central star on LUCI-1 but easily can see on LUCI-2 UT 04:58 -Going to Telluric (guidestar on the left side of det X) LUCI-1 star not quite centered +0.2 LUCI-2 centered OK UT 05:07 - telluric starting spectroscopy UT 05:08 - error grating setup HK G200 1.93 on LUCI-1 - set manually -taking image manually - seemed to be ok UT 05:24 - Imaging script to NGC 7027 - 5pt dither, GS on left, cycle through remaining filters, repeat of K, then skip to [FeII] UT 05:25 accidental faint guide star shows lenslet field stops behind star. UT 05:29 - resending preset, it selected a faint star (GS is bright, but LUCI script passed it R=15.8 mag) - new GS selected UT 05:40 - skipping to [FeII] - filter error LUCI-2 - iniitalizing filter wheel one from IMGUI - came up as Y2 - manually moving to [FeII] - error moving to [FeII] UT 05:42 - brought up LUCI-2 filter wheel unit from LMC - initialized - came up as Br Gamma - manually moving in steps of one filter - moved forward to clear, then back towards [FeII] - worked UT 05:44 - (LUCI-2 will be missing first [FeII] exposure UT 05:48 - image quality is about 20% worse on LUCI-1, but images are still round UT 06:54 for LUCI_R.cfg installed Doug's new hotspot 376.0,263.0 ---> 377.5,265.5 UT 07:05 - completed NGC 7027 imaging script - have now taken data through all LUCI-filters on both side - last exposure luci1.20180913.0081, luci2.20180913.0079
# usage "cl < focus_luci.cl" # Position 1 # move to the first focus position !psfclient left instrument_offsets M2 abs 0 0 0.15 0 0 0 # offset the telescope positiom offset 0 -10 type=ABS !echo "Take LUCI image 1" sleep 10 .........UT 07:16 - going to a Persson star, LUCI-N 5sec Br Gamma measuring FWHM using LUCI RTDs luci2.20180913.0081 0082 ignore -restarting (turning off WFS) UT 07:33 - 0083 start 83 14.11 16.87 84 11.93 10.07 85 5.78 6.81 86 5.01 4.49 87 7.45 7.95 88 12.95 8.49 89 17.34 9.72 #85 - was focus we were at already so all good UT 07.40 repeat exercise LUCI-1 luci1.20180913.0082 first 82 12.33 7.51 83 6.64 6.77 84 5.08 4.06 - best 85 6.81 6.21 86 11.75 12.05 87 couldn't measure -need to adjust focus UT 07:53 Left focus from 31 to 26 mm, but that was the wrong way and 36 is correct (even though we used 37 for this test). 88 - test image to check focus 7.34 9.11 fwhm -going other direction to focus=37 89 - 3.37 3.65 fwhm - BINGO!
2018-09-13T08:14:53.903654+00:00 tcs1 LBT_GCSL: WFS: findSpots: mvSubImageXY (70, 154, 249, 333). 2018-09-13T08:14:53.903663+00:00 tcs1 LBT_GCSL: WFS: findSpots: mvSubImageXY (70, 154, 249, 333), shifted 0,0 pix. 2018-09-13T08:14:53.903671+00:00 tcs1 LBT_GCSL: WFS: findSpots: createSubImageXY (70, 154, 249, 333). 2018-09-13T08:14:54.062792+00:00 tcs1 LBT_GCSL: WFS: findSpots: GUI subImage filename = /Repository/GCSfiles/dailyimages/left_wfscsubimage000405.fits 2018-09-13T08:16:28.592000+00:00 tcs1 LBT_GCSL: WFS: findSpots: mvSubImageXY (23, -90, 202, 89). 2018-09-13T08:16:28.592006+00:00 tcs1 LBT_GCSL: WFS: findSpots: mvSubImageXY (23, 1, 202, 180), shifted 0,-91 pix. 2018-09-13T08:16:28.592017+00:00 tcs1 LBT_GCSL: WFS: findSpots: createSubImageXY (23, 1, 202, 180). 2018-09-13T08:16:28.749746+00:00 tcs1 LBT_GCSL: WFS: findSpots: GUI subImage filename = /Repository/GCSfiles/dailyimages/left_wfscsubimage000406.fitsUT 08:18 - sending preset to NGC 628 to test image quality after change - will test if pausing guiding for 300" will work last exposure 0099 L1, 0098 L2 UT 08:53 changed SX WFScam_sext_x to 113.0,237.7 UT 09:04 Total collimation has NaNs. Cleared by initializing M2 LUTs in PSF, but they come back in a few minutes. Created IT 7404. Restarted PSF, GCS, PCS.
=======
=====================
========