Restart Night #4 UT 2018-09-05
OSA: D.G. Huerta
Observers/ISA: B. Rothberg, J. Hill (Tucson)
Software: P. Kubanek
ISp: J. Riedl, G. Bechetti
Mtn Manager: P. Hartley
Details
UT 01:51 closed
UT 02:00+ P. Kubanek working on TCS 2018B build - closed dome testing
UT 03:00 - checking to see if conditions OK to open
UT 03:01 - powering up LBCs - taking test biases (will attempt NS testing at end of night).
UT 03:18 - starting up LUCI software - in case need to start checkouts - simple imaging and filter exercises
UT 03:57 - We were open briefly, but now closing for threatening clouds. In the meantime, James is making interesting vibration measurements on MV blowers and summer chiller.
Open
UT 06:32 - Opening again - HBS problem with Pump 4 fixed.
UT 07:00 Check pointing on M5 star - SX IE=-53 CA=26 DX IE=-130 CA=+14
UT 07:07 Active preset to Persson star, but we missed the SX guide star on the first try.
AGW4 initial collimation
UT 07:12 SX active optics runs away, so we are back to where we stopped last night. Blocked Zernikes and clear active optics.
Changing lenslet_edge_x now changes fits header correctly, and changes lenslets in tcslog, but does not change Pupil Center as seen by IDL.
07:28 collimate_multiple, 3, /send_zern to collimate with IDL
07:32 resend active preset and running gcs_wfsc_display again while making small changes in lenslet_edge (hoping that offline comparison will reveal something)
gethead left_wfsci*.fits LENSX LENSY PUPCENTX PUPCENTY PUPXONAX PUPYONAX TIME-OBS
Note that on the right side the IDL and GCS "Pupil Center" values agree at the 0.01 pixel level (even though M3 position has pupil out of place).
This confirms that GCS is getting the lenslet edge values from the config file - and that the X0,Y0 changes with changing lenslet edge. It is interesting to note that "edge" is used as a higher value than the lenslet center.
grep GCSL /lbt/log/2018/09/20180905.log | grep " lenslet edge" | grep T07
SX
2018-09-05T07:35:39.345691+00:00 tcs1 LBT_GCSL: WFS: X 0 lenslet edge 168.700000 center 162.010000
2018-09-05T07:35:52.964629+00:00 tcs1 LBT_GCSL: WFS: X 0 lenslet edge 168.700000 center 162.010000
2018-09-05T07:36:06.566545+00:00 tcs1 LBT_GCSL: WFS: X 0 lenslet edge 168.700000 center 162.010000
2018-09-05T07:36:20.237790+00:00 tcs1 LBT_GCSL: WFS: X 0 lenslet edge 168.700000 center 162.010000
2018-09-05T07:36:34.580524+00:00 tcs1 LBT_GCSL: WFS: X 0 lenslet edge 168.700000 center 162.010000
2018-09-05T07:36:48.141354+00:00 tcs1 LBT_GCSL: WFS: X 0 lenslet edge 167.700000 center 161.010000
2018-09-05T07:37:01.723008+00:00 tcs1 LBT_GCSL: WFS: X 0 lenslet edge 167.700000 center 161.010000
2018-09-05T07:37:15.151426+00:00 tcs1 LBT_GCSL: WFS: X 0 lenslet edge 167.700000 center 161.010000
2018-09-05T07:37:28.369964+00:00 tcs1 LBT_GCSL: WFS: X 0 lenslet edge 167.700000 center 161.010000
2018-09-05T07:37:42.315755+00:00 tcs1 LBT_GCSL: WFS: X 0 lenslet edge 167.700000 center 161.010000
2018-09-05T07:58:20.384858+00:00 tcs1 LBT_GCSL: WFS: X 0 lenslet edge 167.700000 center 161.010000
2018-09-05T07:58:20.384866+00:00 tcs1 LBT_GCSL: WFS: X 1 lenslet edge 181.080000 center 174.390000
2018-09-05T07:58:20.384874+00:00 tcs1 LBT_GCSL: WFS: X 2 lenslet edge 194.460000 center 187.770000
2018-09-05T07:58:20.384881+00:00 tcs1 LBT_GCSL: WFS: X 3 lenslet edge 207.840000 center 201.150000
2018-09-05T07:58:20.384889+00:00 tcs1 LBT_GCSL: WFS: X 4 lenslet edge 221.220000 center 214.530000
2018-09-05T07:58:20.384896+00:00 tcs1 LBT_GCSL: WFS: X 5 lenslet edge 245.700000 center 227.910001
2018-09-05T07:58:20.384909+00:00 tcs1 LBT_GCSL: WFS: Y 0 lenslet edge 245.700000 center 239.010000
2018-09-05T07:58:20.384916+00:00 tcs1 LBT_GCSL: WFS: Y 1 lenslet edge 259.080000 center 252.390000
2018-09-05T07:58:20.384924+00:00 tcs1 LBT_GCSL: WFS: Y 2 lenslet edge 272.460000 center 265.770000
2018-09-05T07:58:20.384931+00:00 tcs1 LBT_GCSL: WFS: Y 3 lenslet edge 161.010000 center 279.150000
DX
2018-09-05T07:57:57.363003+00:00 tcs1 LBT_GCSR: WFS: X 0 lenslet edge 354.700000 center 348.010000
2018-09-05T07:57:57.363010+00:00 tcs1 LBT_GCSR: WFS: X 1 lenslet edge 368.080000 center 361.390000
2018-09-05T07:57:57.363017+00:00 tcs1 LBT_GCSR: WFS: X 2 lenslet edge 381.460000 center 374.770000
2018-09-05T07:57:57.363024+00:00 tcs1 LBT_GCSR: WFS: X 3 lenslet edge 394.840000 center 388.150000
2018-09-05T07:57:57.363030+00:00 tcs1 LBT_GCSR: WFS: X 4 lenslet edge 408.220000 center 401.530000
2018-09-05T07:57:57.363037+00:00 tcs1 LBT_GCSR: WFS: X 5 lenslet edge 223.800000 center 414.910001
2018-09-05T07:57:57.363049+00:00 tcs1 LBT_GCSR: WFS: Y 0 lenslet edge 223.800000 center 217.110000
2018-09-05T07:57:57.363055+00:00 tcs1 LBT_GCSR: WFS: Y 1 lenslet edge 237.180000 center 230.490000
2018-09-05T07:57:57.363061+00:00 tcs1 LBT_GCSR: WFS: Y 2 lenslet edge 250.560000 center 243.870000
2018-09-05T07:57:57.363067+00:00 tcs1 LBT_GCSR: WFS: Y 3 lenslet edge 348.010000 center 257.250000
Preliminary adjustment of DX M3
07:48 switch to preliminary DX M3 adjustment (applying the same offsets Doug measured at the 4D focal station as a first guess)
Starting DX M3 absolute Tip=-1200 Tilt=+400 arcsec
Moving in steps of 40 arcsec on M3 to Tip=-865 Tilt=-360 (delta +335, -760). The basic strategy was successful. This moved the DX pupil closer to the normal pupil position, but did not quite center it in the historical subimage cutout.
Saved this new position in positions.conf until we get a better value.
08:01 ACQUIRE preset to update pointing and move to elevation less than 84 degrees. SX IE=-36 CA=+5 DX IE=-62 CA=+1
08:07 ACTIVE preset - collimate left side with IDL. IDL converged nicely, but image is jumping into funny shapes.
LUCI wake-up observations
08:15 Preset from LUCI for wakeup. SX side didn't find guide star.
08:18 ACQUIRE preset unwrapping rotator (we had 01:54 hh:mm) - pointing is just fine back on the previous M5 star, and on the Persson star.
SX AGW position (mm): 18.268, 124.477 - well centered.
08:22 Preset from LUCI for wakeup again at PA=270. Again we don't see guide star. Take note that this is our first off-axis guide star with AGW4.
08:24 manual acquire movie while flipping the x-coord of the guide probe also did not find the star.
08:32 ACTIVE preset from IRAF to Persson star with off-axis guide star. Default PA=345 finds star on both sides.
08:34 resend same preset with PA=20 to get off the Y-axis. Succeeds.
AGW position (mm): 30.288, 43.562 AGW position (mm): 30.2836, 43.5623
08:36 Preset from LUCI for wakeup again at PA=0 - succeeds with similar left/right pointing. Could guide probe on SX be far decentered from the rotator axis? We recall that AGW4 had guide probe work done last year.
Close
08:41 Closing for clouds
UT 09:57 - if we open plan is to switch to LBCs.
UT 10:40 - still closed - unsure if clouds look threatening?
UT 11:08 - still closed
UT 11:46 - powering off the LBCs
UT 11:50 - closing up shortly