AGW2 transform test with LUCI2@RFBG 20151117 UT

Observers: DMiller (Tucson: Home)
Telescope Operator: GBechetti (LBTO)
AO Support: DMiller
Telescope Support: (LBTO)
Software Support: TSargent (Tucson)
Instrument Support: ESolheid (LBTO)
Engineering Support: DAshby

Summary

Details

06:26 IRCR: preset, ACT0282, MODE=GUIDE, GS=0, PA=0.00000 (iif_preset)
  • Target wavelength 1.65
         # Target star: 0   ACT0282
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 1.650
         # Guide star: 0
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 0.630

TCS log:

2015-11-17T06:26:05.485833+00:00::Tue-Nov-17-06:26:05 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: 1.397, 2.165 [mm] SFP_x,y
2015-11-17T06:26:05.486111+00:00::Tue-Nov-17-06:26:05 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: 0.647, 611.358 [mm] SFP_x,y

Doug's transform_pcs_to_agw:

      -1.0007274  -0.00016254187      0.98960000
   0.00016254187      -1.0007274       613.35132
 r =       1.07000
phi =       1.73200
      1.3970      2.1650     -0.4088    611.1850     -1.0559     -0.1729      0.6472    611.3578
      0.0000      0.0000      0.9896    613.3513     -1.0555     -0.1753      2.0451    613.5266

gcscleint getStatus right:

dlmiller@obs2:1 % gcsclient getStatus right
GCS Version: 4.0
GS is set to SFP(x,y): 1.39708, 2.16488
GCS status: "WARNING: guide star too far from hotspot"
selected AGW unit: #2
selected AGW name: "AOAGW2"
Selected AGW type: AIP_LUCIFER
associated rotator angle: mcs.rotatorSide[1].rotators[2].actualPositionASec
GCS isAcquiring: 0
GCS isGuiding: 0
GCS isWFSing: 0
GCS Guide Rate: 0.4
Guide cam exposure time (ms): 2100
WFS cam exposure time (ms): 30000
AGW position: 1.37019, 2.16585 (native: 0.674, 611.357)
AGW Focus: 25.221
AGW Filter: #3 : r'
AGW Status: UNKNOWN

telescope_status:

   PCS_X_RE        FLOAT           1.39708
   PCS_Y_RE        FLOAT           2.16488
   PCS_X_AC        FLOAT           1.37019
   PCS_Y_AC        FLOAT           2.16585
   AGW_X_RE        FLOAT          0.647094
   AGW_Y_RE        FLOAT           611.358
   AGW_X_AC        FLOAT          0.674000
   AGW_Y_AC        FLOAT           611.357
   ROT_ANGLE       FLOAT          0.798667
   POS_ANGLE       FLOAT           0.00000

07:21 IRCR: preset, ACT0282, MODE=GUIDE, GS=0, PA=0.00000
  • Target wavelength same as guide wavelength (0.63)
         # Target star: 0   ACT0282
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 0.630
         # Guide star: 0
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 0.630

2015-11-17T07:21:14.153134+00:00::Tue-Nov-17-07:21:14 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: 1.280, 2.090 [mm] SFP_x,y
2015-11-17T07:21:14.153405+00:00::Tue-Nov-17-07:21:14 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: 0.764, 611.433 [mm] SFP_x,y

   PCS_X_RE        FLOAT           1.28000
   PCS_Y_RE        FLOAT           2.09000
   PCS_X_AC        FLOAT           1.26725
   PCS_Y_AC        FLOAT           2.09107
   AGW_X_RE        FLOAT          0.764241
   AGW_Y_RE        FLOAT           611.433
   ROT_ANGLE       FLOAT          0.677442
   POS_ANGLE       FLOAT           0.00000

      -1.0007274  -0.00016254187      0.98960000
   0.00016254187      -1.0007274       613.35132
 r =       1.07000
phi =       1.73200
      1.2800      2.0900     -0.2917    611.2600     -1.0559     -0.1731      0.7642    611.4330
      0.0000      0.0000      0.9896    613.3513     -1.0555     -0.1753      2.0451    613.5266

07:30 IRCR: preset, ACT0282, MODE=GUIDE, GS=0, PA=0.00000
  • Target wavelength brakett gamma (2.165)
         # Target star: 0   ACT0282
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 2.165
         # Guide star: 0
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 0.630

2015-11-17T07:30:52.529546+00:00::Tue-Nov-17-07:30:52 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: 1.320, 2.157 [mm] SFP_x,y
2015-11-17T07:30:52.529827+00:00::Tue-Nov-17-07:30:52 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: 0.725, 611.366 [mm] SFP_x,y

   PCS_X_RE        FLOAT           1.31969
   PCS_Y_RE        FLOAT           2.15702
   PCS_X_AC        FLOAT           1.32621
   PCS_Y_AC        FLOAT           2.15593
   AGW_X_RE        FLOAT          0.724519
   AGW_Y_RE        FLOAT           611.366
   AGW_X_AC        FLOAT          0.718000
   AGW_Y_AC        FLOAT           611.367
   ROT_ANGLE       FLOAT          0.562923
   POS_ANGLE       FLOAT           0.00000

      -1.0007274  -0.00016254187      0.98960000
   0.00016254187      -1.0007274       613.35132
 r =       1.07000
phi =       1.73200
      1.3200      2.1570     -0.3317    611.1930     -1.0559     -0.1730      0.7242    611.3660

07:35 IRCR: preset, ACT0282, MODE=GUIDE, GS=5, PA=0.00000
         # Target star: 0   ACT0282
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 2.165
         # Guide star: 5
           04:26:27.170 +21:32:04.06 RADEC 2000.0 J2000 0.0 0.0 15.91 R 1.42 B_V 0.630

2015-11-17T07:35:51.176525+00:00::Tue-Nov-17-07:35:51 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: -70.120, 140.583 [mm] SFP_x,y
2015-11-17T07:35:51.176837+00:00::Tue-Nov-17-07:35:51 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: 72.156, 472.984 [mm] SFP_x,y

   PCS_X_RE        FLOAT          -70.1232
   PCS_Y_RE        FLOAT           140.583
   PCS_X_AC        FLOAT          -70.1411
   PCS_Y_AC        FLOAT           140.584
   AGW_X_RE        FLOAT           72.1591
   AGW_Y_RE        FLOAT           472.984
   AGW_X_AC        FLOAT           72.1770
   AGW_Y_AC        FLOAT           472.983
   ROT_ANGLE       FLOAT          0.471684
   POS_ANGLE       FLOAT           0.00000

      -1.0007274  -0.00016254187      0.98960000
   0.00016254187      -1.0007274       613.35132
 r =       1.07000
phi =       1.73200
    -70.1200    140.5830     71.1378    472.6547     -1.0181     -0.3291     72.1559    472.9837
      0.0000      0.0000      0.9896    613.3513     -1.0555     -0.1753      2.0451    613.5266

07:42 IRCR: preset, ACT0282, MODE=GUIDE, GS=4, PA=0.00000
         # Target star: 0   ACT0282
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 2.165
         # Guide star: 4
           04:26:07.084 +21:31:32.72 RADEC 2000.0 J2000 2.0 6.0 15.51 R 1.20 B_V 0.630

2015-11-17T07:42:01.959913+00:00::Tue-Nov-17-07:42:01 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: 97.686, 121.877 [mm] SFP_x,y
2015-11-17T07:42:01.960167+00:00::Tue-Nov-17-07:42:01 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: -95.717, 491.368 [mm] SFP_x,y

   PCS_X_RE        FLOAT           97.6856
   PCS_Y_RE        FLOAT           121.877
   PCS_X_AC        FLOAT           97.6882
   PCS_Y_AC        FLOAT           121.877
   AGW_X_RE        FLOAT          -95.7174
   AGW_Y_RE        FLOAT           491.368
   AGW_X_AC        FLOAT          -95.7200
   AGW_Y_AC        FLOAT           491.368
   ROT_ANGLE       FLOAT          0.398392
   POS_ANGLE       FLOAT           0.00000

      -1.0007274  -0.00016254187      0.98960000
   0.00016254187      -1.0007274       613.35132
 r =       1.07000
phi =       1.73200
     97.6860    121.8770    -96.7873    491.4016     -1.0695      0.0334    -95.7178    491.3682
      0.0000      0.0000      0.9896    613.3513     -1.0555     -0.1753      2.0451    613.5266

07:47 IRCR: preset, ACT0282, MODE=GUIDE, GS=2, PA=0.00000
         # Target star: 0   ACT0282
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 2.165
         # Guide star: 2
           04:26:11.426 +21:29:25.95 RADEC 2000.0 J2000 0.0 0.0 14.96 R 1.08 B_V 0.630

2015-11-17T07:47:16.398084+00:00::Tue-Nov-17-07:47:16 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: 61.385, 45.864 [mm] SFP_x,y
2015-11-17T07:47:16.398338+00:00::Tue-Nov-17-07:47:16 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: -59.379, 567.525 [mm] SFP_x,y

   PCS_X_RE        FLOAT           61.3853
   PCS_Y_RE        FLOAT           45.8637
   PCS_X_AC        FLOAT           61.3658
   PCS_Y_AC        FLOAT           45.8609
   AGW_X_RE        FLOAT          -59.3795
   AGW_Y_RE        FLOAT           567.525
   AGW_X_AC        FLOAT          -59.3600
   AGW_Y_AC        FLOAT           567.528
   ROT_ANGLE       FLOAT          0.289103
   POS_ANGLE       FLOAT           0.00000

      -1.0007274  -0.00016254187      0.98960000
   0.00016254187      -1.0007274       613.35132
 r =       1.07000
phi =       1.73200
     61.3850     45.8640    -60.4475    567.4639     -1.0683     -0.0609    -59.3792    567.5248
      0.0000      0.0000      0.9896    613.3513     -1.0555     -0.1753      2.0451    613.5266

07:51 IRCR: preset, ACT0282, MODE=GUIDE, GS=2, PA=-90.0000
         # Target star: 0   ACT0282
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 2.165
         # Guide star: 2
           04:26:11.426 +21:29:25.95 RADEC 2000.0 J2000 0.0 0.0 14.96 R 1.08 B_V 0.630

2015-11-17T07:51:14.902215+00:00::Tue-Nov-17-07:51:14 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: -42.492, 62.190 [mm] SFP_x,y
2015-11-17T07:51:14.902546+00:00::Tue-Nov-17-07:51:14 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: 44.541, 551.365 [mm] SFP_x,y

   PCS_X_RE        FLOAT          -42.4922
   PCS_Y_RE        FLOAT           62.1900
   PCS_X_AC        FLOAT          -42.3058
   PCS_Y_AC        FLOAT           62.1751
   AGW_X_RE        FLOAT           44.5414
   AGW_Y_RE        FLOAT           551.365
   AGW_X_AC        FLOAT           44.3550
   AGW_Y_AC        FLOAT           551.380
   ROT_ANGLE       FLOAT          -1.34263
   POS_ANGLE       FLOAT          -1.57080

      -1.0007274  -0.00016254187      0.98960000
   0.00016254187      -1.0007274       613.35132
 r =       1.07000
phi =       1.73200
    -42.4920     62.1900     43.5024    551.1092     -1.0389     -0.2562     44.5413    551.3654
      0.0000      0.0000      0.9896    613.3513     -1.0555     -0.1753      2.0451    613.5266

08:02 IRCR: preset, ACT0282, MODE=GUIDE, GS=0, PA=0.00000
         # Target star: 0   ACT0282
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 2.165
         # Guide star: 0
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 0.630

2015-11-17T08:02:09.693144+00:00::Tue-Nov-17-08:02:09 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: 1.281, 2.155 [mm] SFP_x,y
2015-11-17T08:02:09.693411+00:00::Tue-Nov-17-08:02:09 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: 0.764, 611.368 [mm] SFP_x,y

   PCS_X_RE        FLOAT           1.28063
   PCS_Y_RE        FLOAT           2.15547
   PCS_X_AC        FLOAT           1.22326
   PCS_Y_AC        FLOAT           2.15309
   AGW_X_RE        FLOAT          0.763604
   AGW_Y_RE        FLOAT           611.368
   AGW_X_AC        FLOAT          0.821000
   AGW_Y_AC        FLOAT           611.370
   ROT_ANGLE       FLOAT         0.0358401
   POS_ANGLE       FLOAT           0.00000

      -1.0007274  -0.00016254187      0.98960000
   0.00016254187      -1.0007274       613.35132
 r =       1.07000
phi =       1.73200
      1.2810      2.1550     -0.2927    611.1949     -1.0559     -0.1731      0.7632    611.3680
      0.0000      0.0000      0.9896    613.3513     -1.0555     -0.1753      2.0451    613.5266

08:05 Change the transformation to the old (20140117 version)
  • Geno did a oac@oac rdwrconfig -u 2

08:29 IRCR: preset, ACT0282, MODE=GUIDE, GS=0, PA=0.00000
         # Target star: 0   ACT0282
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 2.165
         # Guide star: 0
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 0.630

2015-11-17T08:29:25.464123+00:00::Tue-Nov-17-08:29:25 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: 1.247, 2.157 [mm] SFP_x,y
2015-11-17T08:29:25.464466+00:00::Tue-Nov-17-08:29:25 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: 0.798, 611.366 [mm] SFP_x,y

   PCS_X_RE        FLOAT           1.24658
   PCS_Y_RE        FLOAT           2.15679
   PCS_X_AC        FLOAT           1.23825
   PCS_Y_AC        FLOAT           2.15507
   AGW_X_RE        FLOAT          0.797661
   AGW_Y_RE        FLOAT           611.366
   AGW_X_AC        FLOAT          0.806000
   AGW_Y_AC        FLOAT           611.368
   ROT_ANGLE       FLOAT         -0.428692
   POS_ANGLE       FLOAT           0.00000

      -1.0007274  -0.00016254187      0.98960000
   0.00016254187      -1.0007274       613.35132
 r =       1.07000
phi =       1.73200
      1.2470      2.1570     -0.2587    611.1929     -1.0559     -0.1731      0.7972    611.3660
      0.0000      0.0000      0.9896    613.3513     -1.0555     -0.1753      2.0451    613.5266

08:34 gcsclient selectAGW right LUCI_R.cfg

08:36 IRCR: preset, ACT0282, MODE=GUIDE, GS=0, PA=0.00000
  • Transformation did not change
         # Target star: 0   ACT0282
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 2.165
         # Guide star: 0
           04:26:18.500 +21:28:13.55 RADEC 2000.0 J2000 106.0 -40.0 7.00 R 0.61 B_V 0.630

2015-11-17T08:36:47.261651+00:00::Tue-Nov-17-08:36:47 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: 1.237, 2.157 [mm] SFP_x,y
2015-11-17T08:36:47.261944+00:00::Tue-Nov-17-08:36:47 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: 0.807, 611.366 [mm] SFP_x,y

   PCS_X_RE        FLOAT           1.23730
   PCS_Y_RE        FLOAT           2.15749
   PCS_X_AC        FLOAT           1.23825
   PCS_Y_AC        FLOAT           2.15407
   AGW_X_RE        FLOAT          0.806946
   AGW_Y_RE        FLOAT           611.366
   AGW_X_AC        FLOAT          0.806000
   AGW_Y_AC        FLOAT           611.369
   ROT_ANGLE       FLOAT         -0.546969
   POS_ANGLE       FLOAT           0.00000

08:40 Geno stop and start GCSR
  • Seem to have used new config

08:47:44 IRCR: preset, ACT0282, MODE=GUIDE, GS=0, PA=0.00000
2015-11-17T08:47:44.356703+00:00::Tue-Nov-17-08:47:44 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: 1.223, 2.159 [mm] SFP_x,y
2015-11-17T08:47:44.356988+00:00::Tue-Nov-17-08:47:44 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: 1.170, 610.355 [mm] SFP_x,y

   PCS_X_RE        FLOAT           1.22337
   PCS_Y_RE        FLOAT           2.15885
   PCS_X_AC        FLOAT           1.22373
   PCS_Y_AC        FLOAT           2.15606
   AGW_X_RE        FLOAT           1.17037
   AGW_Y_RE        FLOAT           610.355
   AGW_X_AC        FLOAT           1.17000
   AGW_Y_AC        FLOAT           610.358
   ROT_ANGLE       FLOAT         -0.687093
   POS_ANGLE       FLOAT           0.00000

      -1.0033269    0.0045177476      0.55040205
   -0.0045177476      -1.0033269       612.81421
 r =       1.86000
phi =       1.41372
      1.2230      2.1590     -0.6669    610.6425     -1.8377      0.2874      1.1707    610.3551
      0.0000      0.0000      0.5504    612.8142     -1.8382      0.2838      2.3886    612.5304

08:50 Change oaccontrol.conf back to current one from 20151027
  • Geno execute rdwrconfig -u 2

08:56 IRCR: preset, ACT0282, MODE=GUIDE, GS=0, PA=0.00000
2015-11-17T08:56:38.767850+00:00::Tue-Nov-17-08:56:38 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: 1.212, 2.160 [mm] SFP_x,y
2015-11-17T08:56:38.768137+00:00::Tue-Nov-17-08:56:38 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: 1.182, 610.354 [mm] SFP_x,y

   PCS_X_RE        FLOAT           1.21196
   PCS_Y_RE        FLOAT           2.16018
   PCS_X_AC        FLOAT           1.20879
   PCS_Y_AC        FLOAT           2.15717
   AGW_X_RE        FLOAT           1.18183
   AGW_Y_RE        FLOAT           610.354
   AGW_X_AC        FLOAT           1.18500
   AGW_Y_AC        FLOAT           610.357
   ROT_ANGLE       FLOAT         -0.721038
   POS_ANGLE       FLOAT           0.00000

      -1.0033269    0.0045177476      0.55040205
   -0.0045177476      -1.0033269       612.81421
 r =       1.86000
phi =       1.41372
      1.2120      2.1600     -0.6559    610.6415     -1.8377      0.2874      1.1818    610.3541
      0.0000      0.0000      0.5504    612.8142     -1.8382      0.2838      2.3886    612.5304

08:59 gcsclient selectAGW right LUCI_R.cfg

09:00 IRCR: preset, ACT0282, MODE=GUIDE, GS=0, PA=0.00000
  • still same transformation
2015-11-17T09:00:17.820528+00:00::Tue-Nov-17-09:00:17 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: 1.207, 2.161 [mm] SFP_x,y
2015-11-17T09:00:17.820826+00:00::Tue-Nov-17-09:00:17 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: 1.186, 610.353 [mm] SFP_x,y

   PCS_X_RE        FLOAT           1.20732
   PCS_Y_RE        FLOAT           2.16073
   PCS_X_AC        FLOAT           1.20879
   PCS_Y_AC        FLOAT           2.15816
   AGW_X_RE        FLOAT           1.18649
   AGW_Y_RE        FLOAT           610.353
   AGW_X_AC        FLOAT           1.18500
   AGW_Y_AC        FLOAT           610.356
   ROT_ANGLE       FLOAT         -0.743061
   POS_ANGLE       FLOAT           0.00000

09:01 Geno stop and start GCSR

09:02 IRCR: preset, ACT0282, MODE=GUIDE, GS=0, PA=0.00000
  • New transform now used (20151027) Back to the original from tonight
2015-11-17T09:02:14.030126+00:00::Tue-Nov-17-09:02:14 tcs1 LBT_GCSR: AGW_AIP: doSetProbePosition: calling oacontrol::SFPtoAGWgeneric: 1.205, 2.161 [mm] SFP_x,y
2015-11-17T09:02:14.030390+00:00::Tue-Nov-17-09:02:14 tcs1 LBT_GCSR: __REGTEST__ AGW_AIP: doSetProbePosition: oacontrol::SFPtoAGWgeneric: agwgeneric: 0.839, 611.362 [mm] SFP_x,y

   PCS_X_RE        FLOAT           1.20485
   PCS_Y_RE        FLOAT           2.16105
   PCS_X_AC        FLOAT           1.22326
   PCS_Y_AC        FLOAT           2.15909
   AGW_X_RE        FLOAT          0.839415
   AGW_Y_RE        FLOAT           611.362
   AGW_X_AC        FLOAT          0.821000
   AGW_Y_AC        FLOAT           611.364
   ROT_ANGLE       FLOAT         -0.773785
   POS_ANGLE       FLOAT           0.00000

      -1.0007274  -0.00016254187      0.98960000
   0.00016254187      -1.0007274       613.35132
 r =       1.07000
phi =       1.73200
      1.2050      2.1610     -0.2166    611.1890     -1.0559     -0.1732      0.8393    611.3622
      0.0000      0.0000      0.9896    613.3513     -1.0555     -0.1753      2.0451    613.5266

09:13 Done testing

-- %USERSIG{DougMiller - 2015-11-17}%
Topic revision: r2 - 17 Nov 2015, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback