Commissioning 20150925
Observers: BRothberg, DMiller (Tucson)
Telescope Operator: SAllanson (LBTO)
AO Support: DMiller
Telescope Support: (LBTO)
Software Support:
Instrument Support: JPowers (LBTO)
Engineering Support: DAshby
Details
01:20 Open Chamber
01:38 Preset, Collimate
01:55 Preset to BS9177
02:00 field_collect, BS9177_new.list
- data in /home/lbto/data/20150925/LDG
- seeing ~0.9 to 1.0
- Tip = 11", Tilt = 4"
- Good enough, no change needed
03:00 reconfigure to SX
PepsiPFU
- RPC error when trying to connect to AGw7
- Steve restart oacserver and AGw7
- OK
03:29 Acquire Preset to M5 star. Try to find on guider. OK, in about 2 minutes of spiral
04:00 Move tertiary in Tip to center central obscuration over one subap (i.e. only one star missing in the center of SH image rather than two or four dim stars)
04:01 Change WFScam_hotspot_x from 131.3 to 144.3 to move pupil to the left one column
- changed /home/telescope/TCS/Configuration/GCS/PEPSIPFU_L.cfg
04:02 Save new tertiary and pointing model
- Change /home/telescope/Configuration/OSS/position.conf Tip = -400, Tilt = -600
- Change /home/telescope/Configuration/PCS/SX_PFUrigid.20150925.ptmod IE = -105, CA = +18
04:20 Ilya change beam splitters to see if pupil positions are OK. They are. There was some movement, but not much. We has centered the pupil in the beam splitter that will probably be used the most.
05:00 Done. Back to MODS1 and Barry takes over.
-- %USERSIG{DougMiller - 2015-09-25}%
\xA0