E-time for TCS testing - 20140324 UT

Observers: JHill, DMiller (Tucson)
Telescope Operator: SAllanson (LBTO)
AO Support:
Telescope Support: JUrban (LBTO)
Software Support: CBiddick, MDeLaPena, KSummers, TGolata, TSargent, SHooper
Instrument Support: JPower (LBTO)
Engineering Support:

Summary

Plan

   a) test new GCS with MODS1
   b) check NS guiding with MODS1
   c) test new GCS with LUCI1
   d) test NS guiding with LUCI1
   e) test 64-bit AOS closing loop on-sky
   f) binocular guiding test (with up to date telemetry)
   (plus misc other software tests that don't consume time)
   g) measuring the practical AO patrol field
   starting ~7UT
   h) Gregorian cross-talk tests
   i) new Active Optics tests
   starting ~10UT
   j) WRS tests on LBC-Blue (and Red)

Preparations

Created list of potential fast-moving asteroids using Olga's script fastmover.pl. An improved version of the script lives in /home/lbcobs/supportscripts/NonsiderealSupport/ The list of main belt asteroids below is fine for our purposes here, but a flaw in this search procedure is that sbwobs.cgi gives you N asteroids first and does not give the more recently discovered earth-crossing objects with much higher rates. First column is the IAU number, and last colum is the rate.

78: 07:00:00.000 03:42:21.5849 +26:52:54.113 67.89240 8.971753 13.01 68.4826279406172
291: 07:00:00.000 04:29:35.1289 +20:14:32.291 66.75979 11.61699 15.97 67.7629988821643
370: 07:00:00.000 03:49:18.4629 +23:25:34.281 65.25454 7.461819 15.64 65.6797817703467
851: 07:00:00.000 04:32:52.3957 +20:20:21.452 64.02839 11.61424 16.20 65.0732302622953
290: 07:00:00.000 11:26:47.8658 +17:46:57.527 -54.6105 -33.4974 13.91 64.06545494266
23: 07:00:00.000 05:16:33.5456 +30:05:13.161 62.88453 6.045229 11.24 63.1744323835469
46: 07:00:00.000 03:54:17.0432 +18:16:20.496 61.28778 13.51624 13.63 62.7605028745468
931: 07:00:00.000 04:08:56.6016 +16:11:37.193 57.88745 20.01391 14.49 61.2495996802477
1057: 07:00:00.000 04:03:59.9010 +20:32:12.870 58.79000 9.227028 16.26 59.5096811091505
245: 07:00:00.000 03:46:05.2839 +21:07:48.727 56.15228 14.43543 13.30 57.9781009389174
306: 07:00:00.000 18:33:19.5819 -15:44:16.863 57.08086 7.472229 13.33 57.5678624283379
862: 07:00:00.000 03:50:11.4067 +28:03:32.652 57.17015 1.591227 15.20 57.1922901656161
66: 07:00:00.000 05:06:09.5297 +25:50:34.740 56.87755 2.448507 14.20 56.9302281791629
148: 07:00:00.000 05:17:56.0410 +05:46:31.888 49.25850 28.46969 12.68 56.8939633963578
945: 07:00:00.000 06:35:36.5199 +33:18:59.368 34.89579 -42.6229 14.44 55.085640271618
569: 07:00:00.000 05:41:41.2610 +23:35:46.533 54.81587 -0.03321 14.67 54.8158800600793
336: 07:00:00.000 04:14:28.8018 +18:35:51.315 53.99131 8.255131 14.96 54.6187581636864
477: 07:00:00.000 04:18:37.4879 +26:07:57.977 53.88675 6.623503 15.53 54.2922887485277
127: 07:00:00.000 03:56:23.2594 +26:07:11.668 52.90903 10.31775 13.93 53.9056715068405
333: 07:00:00.000 03:40:50.2190 +22:54:19.885 52.12519 10.44396 15.20 53.1611863394498
481: 07:00:00.000 05:05:23.2066 +28:22:22.856 52.66249 6.219210 13.69 53.0284492138343
688: 07:00:00.000 18:44:43.5421 -12:28:32.904 48.68292 12.39996 15.52 50.2372939928894
287: 07:00:00.000 18:39:44.2070 -13:17:03.606 49.00031 8.519550 12.88 49.7354311562552
169: 07:00:00.000 04:53:06.7458 +27:42:21.525 49.49666 0.940191 14.74 49.5055886771593
104: 07:00:00.000 04:46:34.6528 +24:27:12.491 49.00198 5.484054 13.70 49.3078988823831
485: 07:00:00.000 06:21:24.8720 +08:21:02.479 46.40495 15.39499 12.50 48.8919737953235
1067: 07:00:00.000 05:21:49.7753 +24:13:59.059 48.58805 -5.00096 16.11 48.8447356807681
210: 07:00:00.000 05:17:31.8160 +28:01:17.934 48.31426 0.617868 14.43 48.3182106478812
237: 07:00:00.000 03:47:26.4223 +18:32:12.788 45.95692 14.91278 15.10 48.3159342579112
900: 07:00:00.000 17:52:06.7893 -11:48:38.950 45.59813 15.46459 16.10 48.1491744826949
967: 07:00:00.000 05:00:01.6463 +24:11:49.766 47.27318 6.453791 16.95 47.7116858388391
677: 07:00:00.000 03:53:39.8573 +22:19:55.541 45.88486 4.777286 15.44 46.1328824023104
129: 07:00:00.000 17:56:59.3663 -09:53:34.065 45.18848 8.153882 11.26 45.9182372960932
412: 07:00:00.000 04:34:54.6584 +18:02:49.654 43.32666 15.14067 14.72 45.8959622930438
207: 07:00:00.000 05:47:15.6208 +27:23:42.884 45.48015 -2.52771 14.60 45.5503387678577
160: 07:00:00.000 05:17:20.9359 +26:51:41.045 45.53556 0.022366 14.30 45.5355654928272
139: 07:00:00.000 05:25:01.0327 +33:53:24.804 44.73683 -7.77961 12.82 45.4082183112374
825: 07:00:00.000 05:53:42.3741 +24:17:06.158 45.07821 2.004846 16.04 45.1227705741549
364: 07:00:00.000 06:49:08.0936 +25:58:45.995 44.74158 -1.46064 13.83 44.7654157816723
1041: 07:00:00.000 04:53:01.3580 +30:23:09.527 44.36663 5.837584 15.64 44.7490250677482
81: 07:00:00.000 06:00:15.2168 +31:07:00.054 43.83529 -8.96880 13.40 44.7434020032462
591: 07:00:00.000 05:05:16.6939 +32:45:26.399 43.92596 -7.99387 15.87 44.6474178368526
363: 07:00:00.000 04:53:18.4533 +25:25:28.442 44.27015 5.566892 14.52 44.6187905210592
598: 07:00:00.000 05:41:02.0109 +27:03:09.633 43.92866 5.787995 14.62 44.3083294146329
304: 07:00:00.000 17:39:53.7982 -04:46:58.984 40.25119 18.23932 14.29 44.1908484924028
763: 07:00:00.000 06:18:23.9399 +22:31:31.831 43.88075 -4.45321 16.96 44.1061367597141
570: 07:00:00.000 04:07:52.6145 +19:59:16.699 43.21464 7.821668 14.93 43.916780399203
1069: 07:00:00.000 04:11:46.9730 +10:04:18.958 40.81768 15.89966 15.37 43.805047525348
1059: 07:00:00.000 17:36:18.7778 -15:48:43.368 41.92102 12.70405 15.15 43.8037076540662
47: 07:00:00.000 04:10:16.6098 +25:32:05.676 43.27834 5.679952 13.81 43.6494738556824
1062: 07:00:00.000 04:59:38.7261 +27:37:00.860 43.42253 -0.41488 15.42 43.4245119375601
576: 07:00:00.000 04:10:21.9993 +26:51:38.142 43.08049 1.278787 15.36 43.0994653659586
574: 07:00:00.000 12:02:36.9493 -04:47:55.852 -41.2435 12.14473 15.40 42.9944270693645
93: 07:00:00.000 03:59:04.7404 +28:06:26.490 42.33079 5.151239 13.85 42.6430656175095
..................
771: 07:00:00.000 17:47:32.9847 -14:55:15.113 17.32703 10.90274 16.38 20.4718271809944
991: 07:00:00.000 14:07:02.1990 -10:57:21.348 -19.3059 6.536989 16.16 20.3825906105215
667: 07:00:00.000 16:55:56.4353 +06:39:27.013 7.166976 18.97747 15.47 20.2857071009486
567: 07:00:00.000 10:20:55.2292 +24:14:03.339 -20.1851 -1.57675 13.72 20.2465898998449
339: 07:00:00.000 09:48:37.2119 +09:04:35.245 -15.5236 12.92047 14.45 20.1970468628683
324: 07:00:00.000 09:43:36.2098 +11:36:12.193 -20.0308 2.081581 12.06 20.1386674856993
993: 07:00:00.000 07:12:11.0251 +20:38:23.523 20.05976 -0.72441 16.50 20.0728359009309
860: 07:00:00.000 06:54:44.4721 +25:01:37.313 17.12287 -10.4224 15.82 20.0454258821533
294: 07:00:00.000 06:06:53.1121 +20:17:51.964 19.65475 3.357934 16.57 19.939531546926
64: 07:00:00.000 14:18:36.9390 -15:54:01.352 -19.3919 4.534725 11.32 19.9150575303117
317: 07:00:00.000 16:36:22.2272 -19:45:31.441 19.85314 -0.52180 14.21 19.8599960498385
505: 07:00:00.000 09:01:59.1243 +17:55:04.830 18.55099 -6.81943 14.38 19.764712381034
836: 07:00:00.000 09:37:06.7765 +09:01:33.241 -15.2017 12.61744 16.90 19.7557959860796
408: 07:00:00.000 07:04:26.9925 +21:26:52.971 18.52687 -6.60771 14.68 19.6699451814437
692: 07:00:00.000 14:55:24.2767 +05:09:55.924 -19.0496 4.472068 14.41 19.5674896794817
659: 07:00:00.000 12:08:07.8399 -02:07:03.646 -18.3649 6.707342 16.17 19.5514190972155
231: 07:00:00.000 09:50:54.2724 +14:49:34.128 -19.3772 1.810707 14.19 19.4616170879978
875: 07:00:00.000 15:51:29.5423 -11:52:43.757 7.789883 17.74357 15.37 19.3782494952095
733: 07:00:00.000 09:24:02.9347 +20:55:39.359 -15.6825 -11.2176 14.28 19.2814770183718
816: 07:00:00.000 10:20:25.6028 +22:58:26.993 -16.4532 10.04583 14.58 19.2776163108643
73: 07:00:00.000 17:06:09.1589 -25:02:32.461 18.46499 -4.86934 13.98 19.096238575586
503: 07:00:00.000 09:02:03.0692 +17:54:45.040 -18.2458 5.510895 5.05 19.0598840851938
994: 07:00:00.000 08:37:55.5637 +32:07:09.317 -4.16632 -18.5707 15.14 19.0323177997952
832: 07:00:00.000 07:06:01.9334 +21:40:36.726 18.83813 -2.13298 16.52 18.9585006152201
1036: 07:00:00.000 15:44:07.8099 -16:16:53.800 -0.19973 18.90665 14.03 18.9077049452174

I created ephemeris files for asteroids 66, 81,207,364,763 and 339,324,408,503. And I made guide star catalogs for the above asteroids.

Details

TCS Testing with 64-bit cluster

MODS1 monocular

02:02 First ACTIVE preset interupted by power glitch.

02:12 Init SX M2 hexapod since we saw lots of coma, but didn't make much difference.

02:20 10 minutes of guiding here for Michele

02:20:25 missing messages from syslog here

02:29 Hijack NS ACTIVE preset fails because /lbt/ephemeris isn't mounted on 64-bit cluster.

02:36 ACTIVE preset to asteroid 66 with gs=1

As expected, there is a guiding glitch at the time of the probe move. We've verified that it is broken the same as before.

LUCI1 monocular

02:44 Reconfigure for LUCI1 (and LUCI2 which isn't on the telescope)

03:04 ACQUIRE preset

03:06 ACTIVE preset - still starting with lots of coma

03:16 Hijack NS ACTIVE preset to asteroid 66 with gs=1

LUCI2 monocular

03:27 DX M3 is open loop (caused by earlier power glitches?) Cured by Init.

AOS right says lab mode. Doug M arrives in time to confirm that 64-bit AOS with text serialization is broken.

Doug Miller E-time

(in parallel Chris and Stephen are testing 32-bit AOS on right side)

LUCI1 monocular

05:35 Find the readWFScam left now writes the new image in /home/tcs. This is a local directory on the 64-bit machine so I do not have access to this file. Chris B called Stephen. John suggests that we can write a rsync command to insert into IDL to copy the file over.

05:47 Tested send a preset: OK

05:48 Tested send an offset: OK

06:38 PSF GUI
  • Z5 +1000: SEXT=-876 EQU=-1151 57(rot=17), 73(rot=0), 74(rot=30), 75(rot=45), 75(rot=90)z5=-1397
  • Z6 +1000: SEXT=-1168 EQU=-1139 58(rot=17), 77(rot=90) z6=-1192
  • Z9 +1000: SEXT= EQU= 59(rot=10.), 62(rot=0.0)
  • Z10 +1000: SEXT= EQU= 60(rot=10.), 61(rot=0.0)
  • Z7 +1000: SEXT= EQU= 78(rot=5)no, 79(rot=90)no, 80(rot=45) Check these, no coma signal for rot=45
  • Z +1000: SEXT= EQU=
  • Z +1000: SEXT= EQU=

  • 81-83 collimate with sext

07:32 Start working on primary crosstalk

07:33 /home/lbto/data/20150324/cross_1
  • Z4, 11, 22 = 500, 500, 300
  • cross_2 z4, 11, 22 = 1000, 1000, 500
  • find OLD crosstalk coefficients for 4, 11, 22, and none for higher order. Copy values from 32 bit 2014D
  • Find that the crosstalk coefficients constant with changing amplitude. Good!

07:50 Now with nearly correct crosstalk coefficients
  • cross_3 1000, 1000, 500
  • cross_4 500, 500, 300
  • cross_5 300, 300, 200
  • Note, the Z6 LUT on the primary was on even though the rigid secondary is mounted. Thus, the Z6 went from a negative value for Cross_3 to a large values for cross_5. I think this resulted in an under measurement of Z4 in cross_5 compared to _3 and _4
  • John turned off the Z6 LUT

08:47 change Z11/4 from 4.0 to 5.0

08:56 restart PSFL
  • cross_6 Z4 decrease from -600 to -400

09:18 change Z11/4 from 5.0 to 7.0. change Z22/11 from -2.3 to -3.0

09:20 restart PSFL

09:23 Collect cross_8
  • Wrong way on Z22/11
  • Too much on Z11/4

09:39 change Z11/4 from 7.0 to 5.5. change Z22/11 from -3.0 to -2.0
  • cross_9
  • Z11/22 and Z11/4 is spot on!
  • Z22/11 seems to be variable(150 to 400nm). Z22/4 not even close (-900nm)
  • Need more time on April 3rd and 4th