Started in poor weather (high humidity) with spectral verification. Humidity seemed to drop but rose again quickly and we had a telescope problem that stopped azimuth motion (see nightlog for more details). Moved on to LUCI closed dome flexure calibration. Grating tilts did not stabilize for most, but believe this is only a time out error.
LOG
Started the night with spectral verification: (~4 hours)
- Tel @ Zenith,
- ROT=341,
- Lights off in enclosure
- Scripts in /home/observer/LBTO/DThompson/LUCI_Recalib/Lambda_V
0001 00006 test exposures, blind mask in
- cd SlitImg
- executeLUCIScript.sh LS0.75_450um_N180.txt
0007 008 Slit image (OFF-ON)
cd ../G210K
source allscript
0009 0010 grat_210K_ar20992.txt
0011 0012 grat_210K_ar21339.txt
0013 0014 grat_210K_ar21540.txt
0015 0016 grat_210K_ne21714.txt
0017 0018 grat_210K_ar22046.txt
0019 0020 grat_210K_ne22537.txt
0021 0022 grat_210K_ne23107.txt
0023 0024 grat_210K_ar23139.txt
0025 0026 grat_210K_ne23572.txt
0027 0028 grat_210K_ar23851.txt
0029 0030 grat_210K_ar23973.txt
Odd...there was a line close to center in all data
cd ../G210H
source allscript
0031 0032 grat_210H_xe15422.txt
0033 0034 grat_210H_ar15994.txt
0035 0036 grat_210H_xe16058.txt
0037 0038 grat_210H_ar16441.txt
0039 0040 grat_210H_xe16733.txt
0041 0042 grat_210H_ar16945.txt
0043 0044 grat_210H_ne17167.txt actually @ 1.6733
0045 0046 grat_210H_ne17167.txt (corrected)
cd ../G210J
source allscript
0047 0048 grat_210J_ne11691.txt
0049 0050 grat_210J_xe11745.txt
0051 0052 grat_210J_ne12070.txt
0053 0054 grat_210J_ar12443.txt
0055 0056 grat_210J_xe12627.txt
0057 0058 grat_210J_ne12916.txt
00xx 00xx grat_210J_ne13223.txt # Outside of table range?
cd ../G210z
source allscript
0059 0060 grat_210z_ar8410.txt
0061 0062 grat_210z_ar8427.txt
0063 0064 grat_210z_ar8523.txt
0065 0066 grat_210z_ar8670.txt
0067 0068 grat_210z_xe8822.txt
0069 0070 grat_210z_xe8954.txt
0071 0072 grat_210z_xe9048.txt
0073 0074 grat_210z_ar9125.txt
0075 0076 grat_210z_xe9165.txt
0077 0078 grat_210z_ar9227.txt
0079 0080 grat_210z_ar9356.txt
0081 0082 grat_210z_ar9500.txt
0083 0084 grat_210z_xe9516.txt
0085 0086 grat_210z_ar9660.txt
0087 0088 grat_210z_ar9787.txt
0089 0090 grat_210z_xe9802.txt
0091 0092 grat_210z_xe9925.txt
#0093 0094 grat_210z_ar10054.txt skipped?
0093 0094 grat_210z_ar10335.txt
0095 0096 grat_210z_ar10472.txt
0097 0098 grat_210z_ar10677.txt
Check CWLs in headers
cd ../G150
source allscript
0099 0100 grat_150_ar19822.txt
0101 0102 grat_150_ar20323.txt
0103 0104 grat_150_ar20622.txt
0105 0106 grat_150_ar20992.txt
0107 0108 grat_150_ar21339.txt
0109 0110 grat_150_ar21540.txt
0111 0112 grat_150_ne21714.txt
0113 0114 grat_150_ar22046.txt
0115 0116 grat_150_ar22083.txt
0117 0118 grat_150_ar23139.txt
0119 0120 grat_150_ne22537.txt
0121 0122 grat_150_ne23107.txt
0123 0124 grat_150_ne23572.txt
0125 0126 grat_150_ar23852.txt
0127 0128 grat_150_ar23973.txt
cd ../G200HK
source allscript
0129 0130 grat_200HK_ar15994.txt
0131 0132 grat_200HK_ar16441.txt
0133 0134 grat_200HK_ar16945.txt
0135 0136 grat_200HK_ar19822.txt
0137 0138 grat_200HK_ar20622.txt
0139 0140 grat_200HK_ar22046.txt
0141 0142 grat_200HK_ne21047.txt
0143 0144 grat_200HK_ne21714.txt
0145 0146 grat_200HK_ne22537.txt
0147 0148 grat_200HK_ne23107.txt
0149 0150 grat_200HK_ne23572.txt
0151 0152 grat_200HK_xe15422.txt
cd ../G200zJ
Change config to 2nd order
source allscript
0153 0154 grat_200zJ_ar10054.txt
0155 0156 grat_200zJ_ar10472.txt
0157 0158 grat_200zJ_ar11672.txt
0159 0160 grat_200zJ_ar8670.txt
0161 0162 grat_200zJ_ar9125.txt
0163 0164 grat_200zJ_ar9227.txt
0165 0166 grat_200zJ_ar9356.txt
0167 0168 grat_200zJ_ar9500.txt
0169 0170 grat_200zJ_ar9660.txt
0171 0172 grat_200zJ_ar9787.txt
0173 0174 grat_200zJ_ne11691.txt
0175 0176 grat_200zJ_xe11745.txt
0177 0178 grat_200zJ_xe8822.txt
0179 0180 grat_200zJ_xe9048.txt
0181 0182 grat_200zJ_xe9165.txt
0183 0184 grat_200zJ_xe9516.txt
0185 0186 grat_200zJ_xe9802.txt
0187 0188 grat_200zJ_xe9925.txt
0189 N375 through slit image (0.75" Longslit) 1x10.0s
0190 blind filters for dark
06:30 Waiting to see how humidity will settle and AZ drive will work out.
07:30 Humidity = 99. Setting up for flexure compensation:
- LUCI authorized at LFBG
- EL and LFBG Rotator enabled
- Set rotator to -90 degrees
- AGw1 stages homed
- High-bay flood lights OFF (OK if other lights remain on)
- Calibration unit in beam
- Spectroscopic Sieve mask in the FPU
- Lamp(s) need to be turned on/off manually
- Scripts located in /home/observer/LBTO/FlexComp_Calib
Started with tests for exposure time 191; found 10s was reasonable
07:40: 0190, 0191: 1X [1X 10s] = dark
07:50:
START N1.80 200_HK
- Cal lamp on
- Telescope el=90.0 degree
- FC_N180_200HK.cal
- Flexure comp OFF
luci.20140910.0195.fits -90.0000
luci.20140910.0196.fits -53.9996
luci.20140910.0197.fits -17.9996
luci.20140910.0198.fits 18.0004
luci.20140910.0199.fits 54.0003
luci.20140910.0200.fits 90.0004
luci.20140910.0201.fits 126.0004
luci.20140910.0202.fits 162.0003
luci.20140910.0203.fits 198.0002
luci.20140910.0204.fits 234.0003
luci.20140910.0205.fits 270.0003
luci.20140910.0206.fits 306.0004
luci.20140910.0207.fits 342.0003
luci.20140910.0208.fits 378.0003
luci.20140910.0209.fits 414.0003
luci.20140910.0210.fits 450.0001
luci.20140910.0211.fits 450.0000
luci.20140910.0212.fits 413.9997
luci.20140910.0213.fits 377.9997
luci.20140910.0214.fits 341.9996
luci.20140910.0215.fits 305.9997
luci.20140910.0216.fits 269.9997
luci.20140910.0217.fits 233.9996
luci.20140910.0218.fits 197.9997
luci.20140910.0219.fits 161.9997
luci.20140910.0220.fits 125.9997
luci.20140910.0221.fits 89.9996
luci.20140910.0222.fits 53.9996
luci.20140910.0223.fits 17.9997
luci.20140910.0224.fits -18.0003
luci.20140910.0225.fits -54.0003
luci.20140910.0226.fits -90.0001
08:40:
- Cal lamp on
- Telescope el=55.0 degree
- FC_N180_200HK.cal
- Flexure comp OFF
luci.20140910.0227.fits -90.0000
luci.20140910.0228.fits -53.9997
luci.20140910.0229.fits -17.9997
luci.20140910.0230.fits 18.0004
luci.20140910.0231.fits 54.0003
luci.20140910.0232.fits 90.0003
luci.20140910.0233.fits 126.0004
luci.20140910.0234.fits 162.0003
luci.20140910.0235.fits 198.0003
luci.20140910.0236.fits 234.0004
luci.20140910.0237.fits 270.0003
luci.20140910.0238.fits 306.0004
luci.20140910.0239.fits 342.0003
luci.20140910.0240.fits 378.0002
luci.20140910.0242.fits 450.0001
luci.20140910.0243.fits 450.0000
luci.20140910.0244.fits 413.9997
luci.20140910.0245.fits 377.9997
luci.20140910.0246.fits 341.9997
luci.20140910.0247.fits 305.9996
luci.20140910.0248.fits 269.9996
luci.20140910.0249.fits 233.9996
luci.20140910.0250.fits 197.9997
luci.20140910.0251.fits 161.9996
luci.20140910.0252.fits 125.9997
luci.20140910.0253.fits 89.9996
luci.20140910.0254.fits 53.9997
luci.20140910.0255.fits 17.9997
luci.20140910.0256.fits -18.0003
luci.20140910.0257.fits -54.0004
luci.20140910.0258.fits -90.0001
09:30:
- Cal lamp on
- Telescope el=20.0 degree
- FC_N180_200HK.cal
- Flexure comp OFF
luci.20140910.0259.fits -90.0000
luci.20140910.0260.fits -53.9996
luci.20140910.0261.fits -17.9996
luci.20140910.0262.fits 18.0002
luci.20140910.0263.fits 54.0004
luci.20140910.0264.fits 90.0003
luci.20140910.0265.fits 126.0003
luci.20140910.0266.fits 162.0003
luci.20140910.0267.fits 198.0003
luci.20140910.0268.fits 234.0003
luci.20140910.0269.fits 270.0004
luci.20140910.0270.fits 306.0002
luci.20140910.0271.fits 342.0003
luci.20140910.0272.fits 378.0003
luci.20140910.0273.fits 414.0002
luci.20140910.0274.fits 450.0001
luci.20140910.0275.fits 450.0000
luci.20140910.0276.fits 413.9997
luci.20140910.0277.fits 377.9997
luci.20140910.0278.fits 341.9997
luci.20140910.0279.fits 305.9996
luci.20140910.0280.fits 269.9997
luci.20140910.0281.fits 233.9997
luci.20140910.0282.fits 197.9997
luci.20140910.0283.fits 161.9997
luci.20140910.0284.fits 125.9997
luci.20140910.0285.fits 89.9996
luci.20140910.0286.fits 53.9997
luci.20140910.0287.fits 17.9996
luci.20140910.0288.fits -18.0004
luci.20140910.0289.fits -54.0003
luci.20140910.0290.fits -90.0001
10:20 Start N1.8 210zJHK
- Cal lamp on
- Telescope el=90.0 degree
- FC_N180_210zJHK.cal
- Flexure comp OFF
0291: 1X [1X 10s] = dark (blinds in)
0292: 1X [1X 10s] = test (blinds out, lights on configured)
luci.20140910.0293.fits -90.0000
luci.20140910.0294.fits -53.9997
luci.20140910.0295.fits -17.9996
luci.20140910.0296.fits 18.0002
luci.20140910.0297.fits 54.0003
luci.20140910.0298.fits 90.0003
luci.20140910.0299.fits 126.0003
luci.20140910.0300.fits 162.0004
luci.20140910.0301.fits 198.0003
luci.20140910.0302.fits 234.0003
luci.20140910.0303.fits 270.0003
luci.20140910.0304.fits 306.0002
luci.20140910.0305.fits 342.0003
luci.20140910.0306.fits 378.0003
luci.20140910.0307.fits 414.0003
luci.20140910.0308.fits 450.0001
luci.20140910.0309.fits 450.0000
luci.20140910.0310.fits 413.9997
luci.20140910.0311.fits 377.9997
luci.20140910.0312.fits 341.9996
luci.20140910.0313.fits 305.9997
luci.20140910.0314.fits 269.9997
luci.20140910.0315.fits 233.9997
luci.20140910.0316.fits 197.9998
luci.20140910.0317.fits 161.9997
luci.20140910.0318.fits 125.9997
luci.20140910.0319.fits 89.9997
luci.20140910.0320.fits 53.9997
luci.20140910.0321.fits 17.9996
luci.20140910.0322.fits -18.0004
luci.20140910.0323.fits -54.0003
luci.20140910.0324 (Didn't appear in /newdata, so I took another)
luci.20140910.0325.fits -90.0000 (by hand)
11:08
- Cal lamp on
- Telescope el=55.0 degree
- FC_N180_210zJHK.cal
- Flexure comp OFF
luci.20140910.0326.fits -90.0000
luci.20140910.0328.fits -17.9997
luci.20140910.0329.fits 18.0004
luci.20140910.0330.fits 54.0003
luci.20140910.0331.fits 90.0003
luci.20140910.0332.fits 126.0003
luci.20140910.0333.fits 162.0003
luci.20140910.0334.fits 198.0003
luci.20140910.0335.fits 234.0004
luci.20140910.0336.fits 270.0003
luci.20140910.0337.fits 306.0003
luci.20140910.0338.fits 342.0003
luci.20140910.0339.fits 378.0003
luci.20140910.0340.fits 414.0003
luci.20140910.0341.fits 450.0001
luci.20140910.0343.fits 413.9997
luci.20140910.0344.fits 377.9998
luci.20140910.0345.fits 341.9997
luci.20140910.0346.fits 305.9997
luci.20140910.0347.fits 269.9997
luci.20140910.0348.fits 233.9997
luci.20140910.0349.fits 197.9996
luci.20140910.0350.fits 161.9997
luci.20140910.0351.fits 125.9997
luci.20140910.0352.fits 89.9996
luci.20140910.0353.fits 53.9996
luci.20140910.0354.fits 17.9997
luci.20140910.0355.fits -18.0003
luci.20140910.0356.fits -54.0003
luci.20140910.0357.fits -90.0001
11:52
- Cal lamp on
- Telescope el=20.0 degree
- FC_N180_210zJHK.cal
- Flexure comp OFF
luci.20140910.0358.fits -90.0000
luci.20140910.0359.fits -53.9996
luci.20140910.0360.fits -17.9996
luci.20140910.0361.fits 18.0003
luci.20140910.0362.fits 54.0004
luci.20140910.0363.fits 90.0003
luci.20140910.0364.fits 126.0003
luci.20140910.0365.fits 162.0002
luci.20140910.0366.fits 198.0003
luci.20140910.0367.fits 234.0003
luci.20140910.0368.fits 270.0002
luci.20140910.0369.fits 306.0003
luci.20140910.0370.fits 342.0003
luci.20140910.0371.fits 378.0004
luci.20140910.0372.fits 414.0003
luci.20140910.0373.fits 450.0001
luci.20140910.0374.fits 450.0000
luci.20140910.0375.fits 413.9997
luci.20140910.0376.fits 377.9997
luci.20140910.0377.fits 341.9997
luci.20140910.0378.fits 305.9996
luci.20140910.0379.fits 269.9997
luci.20140910.0380.fits 233.9996
luci.20140910.0381.fits 217.8041
luci.20140910.0382.fits 161.9997
luci.20140910.0383.fits 125.9997
luci.20140910.0384.fits 89.9997
luci.20140910.0385.fits 53.9996
luci.20140910.0386.fits 17.9997
luci.20140910.0387.fits -18.0004
luci.20140910.0388.fits -54.0003
luci.20140910.0389.fits -90.0001
12:30 Closing up!