UT 20130621 Technical Observing - LDG Collimation Tests

Observer: DMiller (LBTO)
Telescope Operator: SAllanson (LBTO)
AO Support: DMiller (LBTO)
Telescope Support: MMidkif (LBTO)
Instrument Support: (LBTO)

Summary

LDG

02:30 Open Chanber

03:00 Preset to BS9152

03:24 pupil wobble with pupil_collect
  • /home/dlmiller/data/20130621/pupil_wobble
  • ~1 pixel radius

03:35 field_collect
  • /home/dlmiller/data/20130621/initial
  • Had put last night's LFBG values on M2, Tip=+3, Tilt=-12
  • Nearly 0 focal plane tilt

04:26 Change M2 position from tip=+3, tile=-12
  • Delta Tip=-15, Tilt=-7, (final Tip=-12, Tilt=-19)
  • Manual 0.970 0.613 0 -17.840 186.579

04:29 field_collect
  • /home/dlmiller/data/20130621/tip-15_tilt-7
  • disable AdSec LUT application during three off-axis acquisitions
  • Some focal plane tilt but about the same binodal (at the noise level)

05:30 Installed new M2 position in config files
  • Created /home/telescope/TCS/Configuration/PSF/SXSMMODSCollimation.20130621.dat
  • Created /home/telescope/TCS/Configuration/PCS/SX_Gregorian.20130621.ptmod
  • Edited /home/telescope/TCS/Configuration/PCS/PCSInstrument.conf
  • Created /home/telescope/TCS/Configuration/PCS/PCSInstrument.20130621.conf

05:35 Steve restarted PCS and reinitialized PSF. All Good!

05:40 Pupil_subap_collect moving in Y. Some poorish, variable seeing now.

06:30 preset to South. Better

07:01 pupil_subap_collect moving in Y from -10 to -340" steps -10
  • /home/dlmiller/data/20130621/pupil_subap_y

09:02 pupil_subap_collect moving in Y from -90 to -340" steps -10, X=270
  • /home/dlmiller/data/20130621/pupil_subap_x

10:02 Convergence test
  • Send
    • Z4 = -6000
    • Z5 = 5000
    • Z7 = 3000
  • CoW
    • Start wfscimage 637
    • Finish wfscimage 644
  • Sext with filled pupil
    • Start wfscimage 654
    • Finish wfscimage 661
  • Sext with Dynamic Recon
    • Start wfscimage 672
    • Finish wfscimage 679

10:30 Convergence test
  • Send
    • Z4 = 6000
    • Z5 = 9000
  • CoW
    • Start wfscimage 726
    • Finish wfscimage 739
  • Sext with filled pupil
    • Start wfscimage 746
    • Finish wfscimage 759
  • Sext with Dynamic Recon
    • Start wfscimage 765
    • Finish wfscimage 678 * Sext with Dynamic Recon
    • Start wfscimage 787
    • Finish wfscimage 800

11:00 Convergence test, Dim star
  • Send
    • Z4 = 6000
    • Z5 = 9000
  • CoW
    • Start wfscimage 812 Send 4-11 crap (a lot of trefoil)
    • removed aberration
    • Collimated with sext

-- DougMiller - 21 Jun 2013

This topic: Commissioning > Main > WebHome > Com20130621
Topic revision: 21 Jun 2013, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.