UT 20130621 Technical Observing - LDG Collimation Tests
Observer: DMiller (LBTO)
Telescope Operator: SAllanson (LBTO)
AO Support: DMiller (LBTO)
Telescope Support: MMidkif (LBTO)
Instrument Support: (LBTO)
Summary
LDG
02:30 Open Chanber
03:00 Preset to BS9152
03:24 pupil wobble with pupil_collect
- /home/dlmiller/data/20130621/pupil_wobble
- ~1 pixel radius
03:35 field_collect
- /home/dlmiller/data/20130621/initial
- Had put last night's LFBG values on M2, Tip=+3, Tilt=-12
- Nearly 0 focal plane tilt
04:26 Change M2 position from tip=+3, tile=-12
- Delta Tip=-15, Tilt=-7, (final Tip=-12, Tilt=-19)
- Manual 0.970 0.613 0 -17.840 186.579
04:29 field_collect
- /home/dlmiller/data/20130621/tip-15_tilt-7
- disable AdSec LUT application during three off-axis acquisitions
- Some focal plane tilt but about the same binodal (at the noise level)
05:30 Installed new M2 position in config files
- Created /home/telescope/TCS/Configuration/PSF/SXSMMODSCollimation.20130621.dat
- Created /home/telescope/TCS/Configuration/PCS/SX_Gregorian.20130621.ptmod
- Edited /home/telescope/TCS/Configuration/PCS/PCSInstrument.conf
- Created /home/telescope/TCS/Configuration/PCS/PCSInstrument.20130621.conf
05:35 Steve restarted PCS and reinitialized PSF. All Good!
05:40 Pupil_subap_collect moving in Y. Some poorish, variable seeing now.
06:30 preset to South. Better
07:01 pupil_subap_collect moving in Y from -10 to -340" steps -10
- /home/dlmiller/data/20130621/pupil_subap_y
09:02 pupil_subap_collect moving in Y from -90 to -340" steps -10, X=270
- /home/dlmiller/data/20130621/pupil_subap_x
10:02 Convergence test
- Send
- Z4 = -6000
- Z5 = 5000
- Z7 = 3000
- CoW
- Start wfscimage 637
- Finish wfscimage 644
- Sext with filled pupil
- Start wfscimage 654
- Finish wfscimage 661
- Sext with Dynamic Recon
- Start wfscimage 672
- Finish wfscimage 679
10:30 Convergence test
- Send
- CoW
- Start wfscimage 726
- Finish wfscimage 739
- Sext with filled pupil
- Start wfscimage 746
- Finish wfscimage 759
- Sext with Dynamic Recon
- Start wfscimage 765
- Finish wfscimage 678 * Sext with Dynamic Recon
- Start wfscimage 787
- Finish wfscimage 800
11:00 Convergence test, Dim star
- Send
- CoW
- Start wfscimage 812 Send 4-11 crap (a lot of trefoil)
- removed aberration
- Collimated with sext
--
DougMiller - 21 Jun 2013