UT 20130620 Technical Observing - LFBG Collimation Tests

Observer: DMiller (LBTO)
Telescope Operator: SAllanson (LBTO)
AO Support: DMiller (LBTO)
Telescope Support: MMidkif (LBTO)
Instrument Support: (LBTO)

Summary

LFBG

03:00 Preset ACTIVE to BS9152, collimate

03:20 Preset GUIDE to BS9152 so can collect pupil data

03:34 pupil_collect: pupil_03:34:31.log. About a 2 pixel diameter wobble, so no change needed
  • Note, for each offset in rotation of 60 degrees the guider had to pull the guide star back to the hotspot. This tells use the default on-axis position of the guide probe is not on the rotator axis.

03:59 field_collect on BS9152
  • /home/dlmiller/data/20130620/initial
  • initial.log
  • Focus Tip=-18, Tilt=-29, IE=18, CA=29
  • Global -3.21 0.102 0.4 -42 -569.2
  • Manual 1.481 0.919 0.0 -176.759 284.779
  • Active -0.092 -0.410 -0.081 42.753 -7.74
  • Total -1.98 1.393 0.937 173.25 135.147

05:00 Turned on sending of high order zernikes (12-21)

05:15 field_collect
  • /home/dlmiller/data/20130620/tip-18_tilt-29

06:30 Changed Tip/Tilt of secondary from initial values
  • Tip=+3, Tilt=-12, IE=-3, CA=+12
  • Global -3.21 0.102 0.4 -42 -569.2
  • Manual 0.613 -0.153 0.0 29.46 117.84
  • Active -0.055 -0.477 -0.073 60.1 1.909
  • Total -2.523 -0.277 1.214 397.541 -20.222

06:45 field_collect
  • /home/dlmiller/data/20130620/tip+3_tilt-12
  • From 0 Astig get tip=-10, tilt=+5

07:40 Changed Tip/Tilt of secondary from tip+3, tilt-12
  • Tip=+30, Tilt=0, IE=-30, CA=0 (+33, -12)
  • Global -3.21 0.102 0.4 -42 -569.2
  • Manual 0.613 -1.685 0 324.059 117.840
  • Active 0.161 -0.539 -0.065 50.593 11.563
  • Total -2.068 -2.454 1.536 703.418 5.383

07:45 field_collect
  • /home/dlmiller/data/20130620/tip+30

08:40 Change Tip/Tip of secondary from tip+3, tilt-12
  • Tip=0, Tilt=+30, IE=0, CA=-30 (+3, +18)
  • Global -3.21 0.102 0.4 -42 -569.2
  • Manual -0.919 -0.153 0 29.46 -176.759
  • Active 0.162 -0.765 -0.015 79.757 16.910
  • Total -3.617 -1.058 1.602 436.488 -292.901

08:45 field_collect
  • /home/dlmiller/data/20130620/tilt+30

09:40 Change Tip/Tip of secondary from tip+3, tilt-12
  • Tip=0, Tilt=-30, IE=0, CA=+30 (+3, -42)
  • Global -3.21 0.102 0.4 -42 -569.2
  • Manual 2.145 -0.153 0 29.46 412.439
  • Active 0.161 -0.828 -1.426 93.013 11.004
  • Total -0.962 -0.503 1.41 436.920 283.880

09:43 field_Collect
  • /home/dlmiller/data/20130620/tilt-30

09:40 Change Tip/Tip of secondary back to tip+3, tilt-12
  • Tip=0, Tilt=0, IE=0, CA=0
  • Global -3.21 0.102 0.4 -42 -569.2
  • Manual 0.613 -0.153 0.0 29.46 117.84
  • Active 0.049 -0.829 0.017 101.094 -0.333
  • Total -3.156 0.081 1.109 435.473 -33.756

10:44 field_collect
  • /home/dlmiller/data/20130620/final

11:05 preset to BS9188. Higher

11:07 test offsets to get one full subap motion of pupil
  • /home/dlmiller/data/20130620/pupil_subap

11:40 Close

-- DougMiller - 20 Jun 2013
Topic revision: r3 - 20 Jun 2013, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.