Technical Observing: 28 November 2012 UT

Observer: DMiller, JGuerra (LBTO)
Telescope Operator: DHuerta (LBTO)
Software Support: TLeibold (Tucson)
AO Support: DMiller (LBTO)
Telescope Support: JLittle (LBTO)
Instrument Support: JMorris (LBTO)

Summary

  • Original Cow Active Optics works (converged at the beginning of the night)
  • Fallback from Sext to new Cow when not enough spots are found by Sext
  • New Cow collimates proplerly
  • Sextractor Act Optis converge with beginning of the night collimation

Problems to Fix:
  • iif.async for left and right should be set to 0 if monocular (iif_init.pro)

Details

00:01 Open Chamber

00:30 Change links to GCS.20121127.V2.7.3.3 and to directory GCS.newWFS

01:00 David send ACTIVE preset. OK. A lot of coma, but collimating. Using original Cow because UseSextract false in LUCI_L.cfg (from testing).

01:10 Change to UseSextract true (and set rm_flat to false). Now new Cow is being used. Sext is finding 0 spots. Error running sex, .nnw file not found. Torsten copy the file and Sext now used.

01:20 GCS and IDL sext output is exactly the same.

01:25 Cancel preset. David clears C00 and Active Optics on Primary and Secondary so we can do a beginning of the night collimation with Sext.

01:30 Active Preset fails: Guiding Sext could not find a file. The new GCS put in a "left" in a file name where it shouldn't. Stop and start GCSL and it works for the first preset. Torsten will fix and make new patch.

01:34 Restarted GCS and Preset successful. Collimate from beginning of the night with Sext. OK

01:43 Patched GCS. David stop and start GCSL. 1st preset successful. 2nd preset successful. Problem fixes.

01:56 Confirmed that IRAF:rangebal works. We should be ready to collect a pointing and collimation model. Confirmed that the M1 and M2 values in the wfsc image header.

02:10 Test my IDL pre

02:21:01 Shell ripped. Active Optics continues and collimate to ~150 nm WFE for the sensed modes. Z12-Z22 sensed ~700 nm, but are not being sent. Not sure the scale factors are correct. See wfsc image 111.

Sextractor collecting data.

02:30 - 04:30 JC collects sext data The sexstractor active optics was running during the acquisitions of various fields at different conditions; faint star, vignetting, large aberration, astigmatism, bright background.

Wed Nov 28 02:41:02 2012 preset, AO820, MODE=ACTIVE, GS=10 # Target star: 0 AO820 23:30:41.71 +46:39:56.3 RADEC 2000.0 J2000 488.0 -84.0 12.70 R 2.00 B_V 1.65 # Guide star: 10 23:31:00.152 +46:43:50.61 RADEC 2000.0 J2000 0.0 0.0 14.38 R 0.90 B_V 0.63
  Vignetting by the guide probe, the active optics closed the loop. Every time the corrections values were converging
  • vignetting:
    AO820_GS10_VIG2.png
(attach screenshot vignetting)

Wed Nov 28 02:48:08 2012 preset, AO820, MODE=ACTIVE, GS=3 Wed Nov 28 02:48:09 2012 # Target star: 0 AO820 Wed Nov 28 02:48:09 2012 23:30:41.71 +46:39:56.3 RADEC 2000.0 J2000 488.0 -84.0 12.70 R 2.00 B_V 1.65 Wed Nov 28 02:48:09 2012 # Guide star: 3 Wed Nov 28 02:48:09 2012 23:30:43.563 +46:36:33.62 RADEC 2000.0 J2000 -4.0 2.0 14.72 R 1.40 B_V 0.63

Wed Nov 28 02:53:49 2012 preset, AO820, MODE=ACTIVE, GS=4, PA=180.000 (iif_preset) Wed Nov 28 02:57:03 2012 => irc_setstars: Command Successful Wed Nov 28 02:53:49 2012 # Target star: 0 AO820 Wed Nov 28 02:53:49 2012 23:30:41.71 +46:39:56.3 RADEC 2000.0 J2000 488.0 -84.0 12.70 R 2.00 B_V 1.65 Wed Nov 28 02:53:49 2012 # Guide star: 4 Wed Nov 28 02:53:49 2012 23:30:28.767 +46:36:55.67 RADEC 2000.0 J2000 0.0 0.0 15.11 R 1.42 B_V 0.63 (attach screenshot ao820_gs4_smallvig.png)

Wed Nov 28 02:57:03 2012 preset, AO820, MODE=ACTIVE, GS=1, PA=90.0000 (iif_preset) Wed Nov 28 03:01:15 2012 preset, AO696, MODE=ACTIVE, GS=2, PA=0.00000 (iif_preset) ELEVATION 31 Wed Nov 28 03:05:44 2012 => irc_presettelescope: Command Successful (SCREENSHOT ASTIGM-EL30)

TIME TO COLLIMATE? ABOUT 7 MINUTES,.. IT IS NOT IMPROVING. REMAINS ABOUT 500 RMS WFE
LOOSING STAR CLOUDY??

Wed Nov 28 03:18:26 2012 preset, AO696, MODE=ACTIVE, GS=6, PA=0.00000 (iif_preset) Wed Nov 28 03:19:01 2012 => irc_presettelescope: Command Successful

The star can't be seeing, not corrections..
(screenshot ao696_gs6_cloudy.png)

Wed Nov 28 03:26:54 2012 preset, AO706, MODE=ACTIVE, GS=0, TS=0 (iif_check_preset) Wed Nov 28 03:26:54 2012 # Target star: 0 AO706 Wed Nov 28 03:26:54 2012 21:01:54.761 +02:16:43.38 RADEC 2000.0 J2000 2.0 -14.2 9.35 R 2.15 B_V 1.65 Wed Nov 28 03:26:54 2012 # Guide star: 0 Wed Nov 28 03:26:54 2012 21:01:54.761 +02:16:43.38 RADEC 2000.0 J2000 2.0 -14.2 9.35 R 2.15 B_V 0.63

Wed Nov 28 03:44:14 2012 preset, AO1061, MODE=ACTIVE, GS=0, TS=0, PA=0.00000 (iif_preset) Wed Nov 28 03:46:27 2012 => irc_presettelescope: Command Successful
 time:2 minutes to drop to 600rms wfe 
(screenshot ao1061_astig-el70.png)

# Target star: 0 AO1061 23:28:01.060 +22:28:28.86 RADEC 2000.0 J2000 9.1 -4.0 10.60 R 1.00 B_V 1.65 # Guide star: 0 23:28:01.060 +22:28:28.86 RADEC 2000.0 J2000 9.1 -4.0 10.60 R 1.00 B_V 0.63

 time:2 minutes to drop to 600rms wfe 
  • Astigmatism_elevation 70:
    ao1061_astig-el702.png

Wed Nov 28 03:51:38 2012 preset, AO1061, MODE=ACTIVE, GS=5, PA=180.000 (iif_preset) Wed Nov 28 03:53:02 2012 => irc_presettelescope: Command Successful # Target star: 0 AO1061 23:28:01.060 +22:28:28.86 RADEC 2000.0 J2000 9.1 -4.0 10.60 R 1.00 B_V 1.65 # Guide star: 5 23:28:08.646 +22:26:37.31 RADEC 2000.0 J2000 0.0 0.0 15.32 R 0.86 B_V 0.63

preset, AO1061, MODE=ACTIVE, GS=5, PA=180.000 (iif_preset)

Wed Nov 28 03:56:46 2012 preset, AO786, MODE=ACTIVE, GS=2, PA=0.00000 (iif_preset) Wed Nov 28 03:58:06 2012 => irc_presettelescope: Command Successful # Target star: 0 AO786 23:50:58.116 +19:56:34.74 RADEC 2000.0 J2000 870.0 -156.0 14.20 R 2.79 B_V 1.65 # Guide star: 2 23:51:06.582 +19:58:19.22 RADEC 2000.0 J2000 -6.0 2.0 15.26 R 1.39 B_V 0.63 preset, AO786, MODE=ACTIVE, GS=2, PA=0.00000 (iif_preset)

 start active optics.. time: start with 1015rms wfe to 330rmswfe 2 minutes. 

Wed Nov 28 04:02:18 2012 preset, AO786, MODE=ACTIVE, GS=3, PA=180.000 (iif_preset) Wed Nov 28 04:03:41 2012 => irc_presettelescope: Command Successful # Target star: 0 AO786 23:50:58.116 +19:56:34.74 RADEC 2000.0 J2000 870.0 -156.0 14.20 R 2.79 B_V 1.65 # Guide star: 3 23:50:44.155 +19:55:33.14 RADEC 2000.0 J2000 0.0 14.0 14.64 R 1.65 B_V 0.63 preset, AO786, MODE=ACTIVE, GS=3, PA=180.000 (iif_preset)

 TIME: START WITH 1354 TO 398 3 MINUTES. 

Wed Nov 28 04:07:09 2012 preset, AO715, MODE=ACTIVE, GS=3, PA=180.000 (iif_preset) Wed Nov 28 04:08:25 2012 => irc_presettelescope: Command Successful # Target star: 0 AO715 21:49:07.386 +18:19:35.49 RADEC 2000.0 J2000 174.0 207.0 15.40 R 2.00 B_V 1.65 # Guide star: 3 21:49:18.574 +18:17:13.78 RADEC 2000.0 J2000 0.0 0.0 14.24 R 0.69 B_V 0.63 preset, AO715, MODE=ACTIVE, GS=3, PA=180.000 (iif_preset)

 time: 1609rms wfe to 574 in  3 minutes. 
(screenshot AO715_GS3-ASTIG.png) dimm:1.6"

Wed Nov 28 04:14:08 2012 preset, AO715, MODE=ACTIVE, GS=7, PA=180.000 (iif_preset) Wed Nov 28 04:14:43 2012 => irc_presettelescope: Command Successful # Target star: 0 AO715 21:49:07.386 +18:19:35.49 RADEC 2000.0 J2000 174.0 207.0 15.40 R 2.00 B_V 1.65 # Guide star: 7 21:49:22.075 +18:15:48.67 RADEC 2000.0 J2000 0.0 0.0 15.43 R 1.22 B_V 0.63 preset, AO715, MODE=ACTIVE, GS=7, PA=180.000 (iif_preset)

 with bad seeing and vignetting the active optics drops the rms to 480. 
  • bad seeing and vignetting:
    ao715_gs7_badseeing_vig.png

Wed Nov 28 04:25:52 2012 preset, AO131, MODE=ACTIVE, GS=3 (iif_check_preset) Wed Nov 28 04:25:52 2012 # Target star: 0 AO131 Wed Nov 28 04:25:52 2012 03:01:38.52 +49:39:13.7 RADEC 2000.0 J2000 157.0 -116.0 14.10 R 2.00 B_V 1.65 Wed Nov 28 04:25:52 2012 # Guide star: 3 Wed Nov 28 04:25:52 2012 03:01:43.371 +49:40:25.16 RADEC 2000.0 J2000 2.0 -4.0 15.66 R 1.24 B_V 0.63

 high background and it is not getting the star 

  • Failed to acquire:
    ao131_gs3_failedacquire2.png

Pointing and Collimation model data

04:39 David starts a pointing log at /home/telescope/PointingLogs/20121128_sx.log

04:45 - 08:47 JC collect 36 point monocular range balanced pointing and collimation model data set

Position # Star Name Target Star GStar WFSC Image
1 WT10_355 26 26 left_wfscimage000319.fits
3 WT10_405 12 12 left_wfscimage000323.fits
4 WT10_364 15 15 left_wfscimage000327.fits
6 WT10_206 4 4 left_wfscimage000331.fits
7 WT10_244 6 6 left_wfscimage000335.fits
8 ACT0121 6 6 left_wfscimage000337.fits
9 ACT0265 1 1 left_wfscimage000340.fits
10 ACT0216 12 12 left_wfscimage000345.fits
11 WT10_318 6 6 left_wfscimage000350.fits
12 WT10_331 8 8 left_wfscimage000354.fits
13 WT10_301 26 26 left_wfscimage000359.fits
14 WT10_269 8 8 left_wfscimage000363.fits
15 WT10_314 1 1 left_wfscimage000367.fits
18 WT10_108 6 6 left_wfscimage000372.fits
19 WT10_157 2 2 left_wfscimage000376.fits
20 WT10_297 1 1 left_wfscimage000379.fits
21 ACT0261 2 2 left_wfscimage000384.fits
22 ACT0223 1 1 left_wfscimage000392.fits
23 ACT0293 1 1 left_wfscimage000399.fits
24 WT10_342 1 1 left_wfscimage000402.fits
25 WT10_395 6 6 left_wfscimage000407.fits
26 ACT0408 1 1 left_wfscimage000413.fits
27 WT10_407 3 3 left_wfscimage000421.fits
28 ACT0370 1 1 left_wfscimage000429.fits
29 ACT0383 3 3 left_wfscimage000435.fits
30 ACT0397 7 7 left_wfscimage000442.fits
31 ACT0410 1 1 left_wfscimage000448.fits
32 WT10_355 26 26 left_wfscimage000454.fits
33 WT10_384 4 4 left_wfscimage000459.fits
34 WT10_364 15 15 left_wfscimage000466.fits
35 WT10_297 1 1 left_wfscimage000471.fits
37 WT10_342 1 1 left_wfscimage000474.fits
2 ACT0409 3 3 left_wfscimage000484.fits
16 ACT0301 35 35 left_wfscimage000489.fits
17 ACT0197 6 6 left_wfscimage000493.fits
36 WT10_366 19 19 left_wfscimage000498.fits

Failed Acquisitions

Images with -> "chosen spot" and ** "correct spot"

left_acquire000030.fits
#   1 X_IMAGE         Object position along x                         [pixel]
#   2 Y_IMAGE         Object position along y                         [pixel]
#   3 FLUX_AUTO       Flux within a Kron-like elliptical aperture     [count]
#   4 FWHM_IMAGE      FWHM assuming a gaussian core                   [pixel]
#   5 ELLIPTICITY     1 - B_IMAGE/A_IMAGE
#   6 FLAGS           Extraction flags
#   7 CLASS_STAR      S/G classifier output
->    82.528     31.274      1113354    89.76    0.701  16  0.00
    65.720    249.273     420833.1    48.21    0.934  16  0.01
**    95.162    142.512     955703.2    16.93    0.257   0  0.72

left_acquire000032.fits
**   131.626     94.757     76488.12     8.96    0.132   0  0.39
->   144.242    249.638     491683.2    47.95    0.952  16  0.01

left_acquire000035.fits
**    87.904    125.408     226947.5    12.49    0.086   0  0.67
->   139.315    249.430     377178.7    53.67    0.958  16  0.01

left_acquire000071.fits
**    59.450    158.008     129977.3    14.09    0.098   0  0.41
->   129.399    247.939     226504.9    81.45    0.955  16  0.00

Is only the total flux being used to choose which spot to take? It looks like FWHM, ELLIP, FLAG and CLASS could be used.

Made InfromationTechnology#4379

Center of Rotation on LFBG Guide camera

09:10 Take 60 second image 04, but a bit out of focus

09:15 Active preset for a bit

09:23 collect image 05, center at

-- DougMiller - 28 Nov 2012

Topic attachments
ISorted descending Attachment Action Size Date Who Comment
AO820_GS10_VIG2.pngpng AO820_GS10_VIG2.png manage 76 K 29 Nov 2012 - 00:59 UnknownUser vignetting
ao1061_astig-el702.pngpng ao1061_astig-el702.png manage 75 K 30 Nov 2012 - 01:34 UnknownUser Astigmatism_elevation 70
ao131_gs3_failedacquire2.pngpng ao131_gs3_failedacquire2.png manage 55 K 30 Nov 2012 - 01:38 UnknownUser Failed to acquire
ao715_gs7_badseeing_vig.pngpng ao715_gs7_badseeing_vig.png manage 79 K 30 Nov 2012 - 01:34 UnknownUser bad seeing and vignetting
Topic revision: r9 - 25 Jul 2014, DouglasFisher
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback