UT 20120601 Source Extractor Active Optics, AdSec Rested Collimation and Closed AO Loop on DX
Observer: DMiller, KBoutsia (LBTO) JCGuerra (Tucson)
Telescope Operator: DHuerta (LBTO)
Telescope Support: MMidkiff(LBTO)
Instrument Support: JMorris (LBTO)
Summary
Tasks:
- Doug's IDL send binocular presets. It was quite easy.
- Olga tested the binocular range balance. Trouble with authorize on left side.
- Closed the DX AO loop on a bright star. This took about 2.5 hours as we had a hardware problem that required unplugging and plugging in the AGw/W Unit. Plus CCD39 stopped communicating, auto gain failed, re-rotator no enabled
- Collect more Astig LUT and COW -vs- SEXT data
Details
02:15 Open chamber
Binocular presets from IDL
02:40 Try to send binocular preset. Received several warnings about requested instrument/focal station combination not allowed and binoculaControl SYNCPRESET command ignored: Duplicate event. Not clear to me the order of commands yet.
02:45 Success. Sent in acquire on both sides.
02:50 David align pointing model on left side. Could not see star on right side. Changing IE/CA on right. Left star stays stationary.
03:08 David re-initialize the right hexapod
03:15 Here's my syncpreset sequence
- R iif_register
- R iif_syncpreset
- R iif_preset, ACT0277, MODE=ACQUIRE, GS=0
- L iif_register
- L iif_syncpreset
- L iif_preset, ACT0277, MODE=ACQUIRE, GS=0
03:30 David send monocular preset to right side to find star
03:57 Find star and set IE/CA
- Left: IE=-18.0, CA=-45.0
- Right: IE = -54.5, CA = -137.8
03:58 Authorize on both sides. Send binocular preset. See star on right. Move star so can see on left.
04:05 Binocular preset to ACT0277, MODE=ACQUIRE, GS=1, PA=180. Success. A lot of coma on both sides. Collimating
- Left: IE=-47.0, CA=-15.0
- Right: IE = -49.5, CA = -147.8
Binocular Range Balance
04:15 Olga send several range bal commands. Getting error on left side about not registered
DX AO Closed Loop
04:53 Start with DX AO Closed Loop. Have several problems:
- could not talk to ts8 in W Ring. Had to go to zenith, unplug and plug the power to the agw/W unit
- lost communication to CCD37 twice. Had to restart slope computer
- rerotator not getting rotator position. 10 mode closed loop cause shell to rip. Twice
- autogain failed
07:00 Finally closed loop on AO1019. bin 1, 400 modes. offset, 5, 0 successful.
Going to collect LUT and Sext data
Astig LUT and Collimation data sets
New LUT and SEXT Collimation
Data in /OldRepository/AGW_Data/20120602/SEXTnewLUT
07:25 AO1018, el 79, wfsc Failed. David set pointing
07:31 AO1018, el 79, wfsc 1
07:36 AO883, el 42, wfsc 7
07:39 AO1029, el 67, wfsc 11
07:44 AO1039, el 29, wfsc 14
07:46 AO1044, el 49, wfsc 17
07:49 AO656, el 67, wfsc 22
07:53 AO696, el 28, wfsc 26
07:58 AO657, el 62, wfsc 31
08:03 AO733, el 45, wfsc 34
08:05 AO710, el 30, wfsc 37
08:09 AO731, el 54, wfsc 44
08:12 AO1028, el 77, wfsc 47
08:16 AO1041, el 40, wfsc 52
New LUT and COW Collimation
Data in /OldRepository/AGW_Data/20120602/COWnewLUT
08:24 AO1027, el 75
08:26 AO1041, el 45
08:29 AO657, el 68
08:33 AO711, el 32
08:36 AO735, el 50
08:39 AO657, el 70
08:42 AO780, el 28
08:47 AO729, el 64 saturated
08:51 AO731, el 62
08:53 AO1039, el 44
08:56 AO780, el 30
08:59 AO735, el 53
09:02 AO660, el 77
09:05 AO710, el 43
New LUT and SEXT Collimation, No Clear C00
Data in /OldRepository/AGW_Data/20120602/SEXTnewLUTnoC00
09:08 AO661, el 76, wfsc 1
09:11 AO711, el 41, wfsc 3
09:15 AO731, el 66, wfsc 7
09:18 AO1062, el 28, wfsc 10
09:22 AO1046, el 60, wfsc 16
09:26 AO1045, el 45, wfsc 20
09:30 AO803, el 30, wfsc 24
09:33 AO732, el 51, wfsc 27
09:35 AO661, el 81, wfsc 31
09:38 AO780, el 41, wfsc 34
09:42 AO1052, el 27, wfsc 37
09:44 AO1045, el 51, wfsc 39
09:47 AO731, el 72, wfsc 43
09:52 AO1064, el 40, wfsc 46
Old LUT and SEXT Collimation
Data in /OldRepository/AGW_Data/20120602/SEXToldLUT
09:56 AO731, el 74, wfsc 1
10:00 AO779, el 40, wfsc 4
10:05 AO735, el 66, wfsc 13
10:09 AO1052, el 33, wfsc 16
10:13 AO779, el 45, wfsc 22
10:16 AO735, el 69, wfsc 26
10:22 AO1069, el 29, wfsc 28
10:25 AO1039, el 60, wfsc 33
10:29 AO779, el 47, wfsc 37
10:32 AO763, el 30, wfsc 40
10:36 AO780, el 49, wfsc 46
10:39 AO733, el 75, wfsc 51
10:42 AO778, el 40, wfsc 53
New LUT and SEXT Image Quality
Data in /OldRepository/AGW_Data/20120602/IQ
10:49 AO735 clear C00, COW, el 77, collimate to 500, irtc 410, 110027
11:00 Clear C00, SEXT, el 77, collimate to 500, wfsc 1-2 wfsc camera problem
11:09 AO735, clear C00, SEXT, el 77, collimate to 500, wfsc still camera problems
11:25 David stopAGW and startAGW and now the camera works.
11:30 Getting too bright. Closing Chamber
--
DougMiller - 29 May 2012