Observer: DMiller, KBoutsia (LBTO)
Telescope Operator: DHuerta (LBTO)
Telescope Support: JUrban(LBTO)
Instrument Support: JMorris (LBTO)
Summary
Seeing was variable from 1.5" to 2" with a couple half hour stints of ~1.0". Not good enough for AGw#1 transformation data collection
Tasks performed
- Collected two Adsec Astigmatism Hysteresis curves
- One with Adsec LUT turned off to measure the hysteresis curve to see if it has change since it was measured last fall
- One with the new AdSec LUT turned on to measure how well this new linear LUT compensates for the elevation dependent astigmatism. As we were collecting the data it looked like the LUT was down the middle of the hysteresis curve. That is, when we were decreasing elevation between presets, the Act Opt added negative (-)Z6. As the elevation increased with new presets, positive (+)Z6 was needed. It's not clear yet, but it may be best to clear C00 (or if possible just the Z6 component of the primary forces) for each preset so we are starting with the Adsec LUT each time we collimate, instead of have the astigmatism from the last preset still on the primary
- Tested Source Extractor Active Optics Algorithm
- Works well for stars down to 16th magnitude
- New background subtraction method caused spurious Z11 for dim (<15th mag) stars. My have to trash it
- Old 4-corner background subtraction works well for source extractor for conditions tested
- Tried to collimate with shell rested
- Could improve rested guide image with several collimation iterations, but could not get SH spot in all subaps (about half or a bit more) so the core of the guide image got more concentrated, but still had a large halo.
- Tried to limit the number of SH spots found (finding spurious spot in empty subaps), but need to work on algorithm a bit more
- Can try to send Z12-21 along with current zernikes to see if image improves.
- Olga tested the Binocular Range Balance routines for Gregorian focal stations. We had LBC authorized on the right so the RangeBal failed. May try to get RFBG authorized on the right tonight or tomorrow night for another try at testing
Details
02:30 Test collimate_multiple routine. Sky is bright so saturating wfsc image. There is a strange dark stripe, but may be because of saturation
02:34 Dave preset ACQUIRE WT10_309
02:56 David preset GUIDE WT10_309 GS=1
02:59 coll_mult, 1, wfsc 18 (foc, astig only), 19-29 all (
AdSec LUT was off)
Adsec Astig LUT OFF
03:10 Test astigmatism on
AdSec GUI
03:17 coll_mult, 5, wfsc 30-34 (all ~250 nm rms)
03:24 preset AO976, gs=0, GUIDE acquire=4, guide=399 (looks round, 1.5")
03:28 preset AO359, GS=0, GUIDE acq=5, guide=435 el 74 (3/1 sausage, sext #35 -2300)
03:32 preset AO357, GS=0, GUIDE acq=6, guide=454 el 65 (4/5, sext #36 -2800)
03:34 preset AO344, GS=0, GUIDE acq=7, guide=474 el 42 (6/1, sext #37 -3200)
03:37 preset AO359, GS=0, GUIDE acq=8, guide=492 el 25 (7/1, sext #38 -3200)
03:40 preset AO345, GS=0, GUIDE Failed, AGw guide probe motion error
03:42 David rehome stages
03:51 preset AO345, GS=0, GUIDE acq=9, guide=520 el 40 (4/1, sext #39 -2400)
03:55 preset AO357, GS=0, GUIDE acq=10, guide=555 el 50 (2/1, sext #1 -1400 Dimm 1.8)
03:59 preset AO359, GS=0, GUIDE acq=11, guide=597 el 59 (round, sext #2 0)
04:02 preset AO975, GS=0, GUIDE acq=12, guide=627 el 69 (round, sext #3 0)
Old AdSec Astig LUT
/OldRepository/AGW_Data/20120531/old_lut_on
04:13 preset AO454, GS=0, GUIDE acq=13 el 84 LUT=0.8 (sext #1 1500 z6 not sent)
04:15 David clear C00, see focus because cleared Z11
04:16 collimate_multiple, 10, /Send, Collimated to 300nm in 5 iterations wfsc 2-11 first astig = 200
04:25 preset AO990, GS=0, GUIDE acq=14 el 71 LUT=2.2
04:25 David clear C00
04:28 collimate_multiple, 10, /Send, Collimated to 300nm in 4 iterations wfsc 12-21, first astig = -1400
04:35 preset AO976, GS=0, GUIDE acq=15 el 61 LUT=2.7
04:35 David clear C00
04:37 collimate_multiple, 10, /Send, EXP=15, Collimated to 300nm in 4 iterations wfsc 23-32, first astig = -2400
04:45 Realize old LUT is being applied. Restarted all processes, but old LUT is applied. The make install-calib recopied the astig_lut_original.sav into astig_lut.sav.
05:00 copy astig_lut_new.lut into astig_lut.sav, but not run make install-calib
05:01 preset failed because M2 UMAC not responding. David re-init UMAC
/OldRepository/AGW_Data/20120531/new_lut_on
JD for xmgrace plots from 0.7 to 0.88
05:05 preset AO451, GS=0, GUIDE acq=16 el 85 LUT=0.9
05:05 David clear C00
05:10 collimate_multiple, 10, /Send, Collimated to 300nm in 4 iterations wfsc 1-10, first astig = -500
05:15 preset AO519, GS=0, GUIDE acq=17 el 74 LUT=2.4
05:15 David clear C00
05:17 collimate_multiple, 10, /Send, EXP=15 Collimated to 300nm in 4 iterations wfsc 11-20, first astig = -1200
05:26 preset AO875, GS=0, GUIDE acq=18 el 64 LUT=3.8
05:26 David clear C00
05:28 collimate_multiple, 10, /Send, EXP=15 Collimated to 300nm in 3 iterations wfsc 21-30, first astig = -1300
05:34 preset AO1014, GS=0, GUIDE acq=19 el 52 LUT=5.9
05:34 David clear C00
05:36 collimate_multiple, 10, /Send, EXP=10 Collimated to 300nm in 3 iterations wfsc 31-40, first astig = -900
05:51 preset AO1029, GS=0, GUIDE acq=20 el 42 LUT=6.1
05:51 David clear C00
05:53 collimate_multiple, 10, /Send, EXP=15 Collimated to 300nm in 3 iterations wfsc 41-50, first astig = -1200
05:51 preset AO657, GS=0, GUIDE acq=23 el 36 LUT=7.1
05:51 David clear C00
05:53 collimate_multiple, 10, /Send, EXP=15 Collimated to 300nm in 3 iterations wfsc 51-60, first astig = -700
06:06 preset AO731, GS=0, GUIDE acq=24 el 29 LUT=9.4 (
AdSed Control GUI shows 7.1 still. Log shows 9.4)
06:06 David clear C00
06:08 collimate_multiple, 10, /Send, EXP=15 wfsc 61-70, first astig = -600
06:13 preset AO657, GS=0, GUIDE acq=25 el 39 LUT=7.9 (
AdSed Control GUI shows 7.1 still. Log shows 7.9)
06:13 David clear C00
06:15 collimate_multiple, 10, /Send, EXP=15 wfsc 71-80, first astig = 600
06:20 preset AO1028, GS=0, GUIDE acq=26 el 53 LUT=5.8 (
AdSed Control GUI shows 5.8. Log shows 5.8. OK now)
06:20 David clear C00
06:22 collimate_multiple, 10, /Send, EXP=15 wfsc 81-90, first astig = 1300
06:28 preset AO612, GS=0, GUIDE acq=27 el 64 LUT=3.9
06:28 David clear C00
06:30 collimate_multiple, 10, /Send, EXP=15 wfsc 91-100, first astig = 800
06:35 preset AO1018, GS=0, GUIDE acq=28 el 71 LUT=3.0
06:35 David clear C00
06:37 collimate_multiple, 10, /Send, EXP=15 wfsc 101-110, first astig = 1200
06:41 preset AO591, GS=0, GUIDE acq=29 el 83 LUT=1.1
06:41 David clear C00
06:43 collimate_multiple, 10, /Send, EXP=15 wfsc 111-120, first astig = 100
06:55 Olga try to send a Binoc Range bal command. send IE CA but failed because
06:41 preset Stone_M1, GS=0, GUIDE acq=30 el 83 LUT=1.1
06:41 David clear C00
06:43 collimate_multiple, 10, /Send, EXP=15 wfsc 121-130, first astig = -800
07:05 Seeing at 1.5". Did have <1.0" for a while, but seeing has gotten worse. Back to Astig LUT
07:15 preset AO591, GS=0, GUIDE acq=31 el 81 LUT=1.5
07:15 David clear C00
07:17 collimate_multiple, 10, /Send, EXP=15 wfsc 131-140, first astig = 80
07:27 Set pupil center from 379,201 to 376.5,199. Central obscuration is not at subap 7,7. Was at 6,7 before
07:27 collimate_multiple, 5, /Send, EXP=15 wfsc 141-145
07:31 preset AO1017, GS=0, GUIDE acq=33 el 70 LUT=3.1
07:31 David DID NOT clear C00. We will compare if leaving astig on primary cause more iterations
07:33 collimate_multiple, 10, /Send, EXP=15 wfsc 146-155, first astig = -450
07:44 preset AO656, GS=0, GUIDE acq=34 el 64 LUT=4.0, collimate_multiple, 10, /Send, EXP=15 wfsc 156-165, first astig = -460
07:50 preset AO656, GS=0, GUIDE acq=35 el 58 LUT=4.9, collimate_multiple, 8, /Send, EXP=15 wfsc 166-173, first astig = -130
07:56 preset AO733, GS=0, GUIDE acq=36 el 42 LUT=7.4 (gui show 6.4), collimate_multiple, 5, /Send, EXP=15 wfsc 174-179, first astig = 1
07:59 preset AO1045, GS=0, GUIDE acq=37 el 27 LUT=9.6 (gui show 6.4), collimate_multiple, 5, /Send, EXP=15 wfsc 180-184, first astig = -500
08:04 preset AO735, GS=0, GUIDE acq=38 el 41 LUT=7.5 (gui show 6.4), collimate_multiple, 5, /Send, EXP=15 wfsc 185-189, first astig = 1900
08:09 preset AO659, GS=0, GUIDE acq=39 el 58 LUT=4.9, collimate_multiple, 5, /Send, EXP=15 wfsc 190-194, first astig = 730
08:13 preset AO656, GS=0, GUIDE acq=40 el 70 LUT=3.1, collimate_multiple, 5, /Send, EXP=15 wfsc 195-199, first astig = -730
08:18 preset AO1016, GS=0, GUIDE acq=41 el 84 LUT=0.9, Nearby bright star. Can use
08:13 preset AO592, GS=0, GUIDE acq=42 el 86 LUT=0.6, collimate_multiple, 5, /Send, EXP=15 wfsc 201-205, first astig = -1200
08:25 unwrap azimuth
08:32 preset AO733, GS=0, GUIDE acq=43 el 48 LUT=6.4, collimate_multiple, 5, /Send, EXP=15 wfsc 206-210, first astig = 150
08:37 preset AO657, GS=0, GUIDE acq=44 el 68 LUT=3.4, collimate_multiple, 5, /Send, EXP=15 wfsc 211-215, first astig = 700
08:42 preset AO1059, GS=0, GUIDE acq=45 el 29 LUT=9.4, collimate_multiple, 5, /Send, EXP=15 wfsc 216-220, first astig = -600
08:47 preset AO1047, GS=0, GUIDE acq=46 el 51 LUT=6.0, collimate_multiple, 5, /Send, EXP=15 wfsc 221-225, first astig = 2400
08:47 preset AO732, GS=0, GUIDE acq=47 el 42 LUT=7.5, collimate_multiple, 5, /Send, EXP=15 wfsc 226-230, first astig = -1300
09:00 preset AO657, GS=0, GUIDE acq=48 el 73 LUT=2.7, collimate_multiple, 5, /Send, EXP=15 wfsc 236-240, first astig = -900
Test Sext on dimm stars
09:13 preset BS9169, GUIDE, GS=7, acq=49 el 64 LUT-4.1, David clear C00
09:15 collimate_multiple, 10, first astig = -630, wfsc 1-6 Zernikes not sent. first astig = -790, wfsc 7-17 GSmag=15, Seeing 1.5" - 2"
09:25 preset AO656, GUIDE, GS=11, PA=-90, acq=50 LUT = 1.4
09:27 collimate_multiple, 10, first astig = 900, wfsc 18-21 GSmag=15, Seeing 1.5" - 2"
09:35 preset AO656, GUIDE, GS=11, PA=-90, acq=50 LUT = 1.4, David clear C00
09:36 collimate_multiple, 10, first astig = 200, wfsc 22-24 GSmag=15.5, Seeing 1.5" - 2"
09:36 Switch
ON background subtraction to wfsc_remove_bg
09:35 preset AO656, GUIDE, GS=16, PA=-90, acq=50 LUT = 1.4, David clear C00
09:38 Clear C00, collimate_multiple, 10, first astig = 200, large Z11 changes on several iterations. wfsc 26-36 GSmag=15.5, Seeing 1.5" - 2"
09:46 preset AO656, GUIDE, GS=20, PA=-90, acq=51 LUT = 1.4, David clear C00
09:46 Clear C00, collimate_multiple, 10, wfsc 37-46 GSmag=16.0, Seeing 1.5" - 2"
10:05 preset AO656, GUIDE, GS=0, PA=-90, acq=55 LUT = 1.4
10:05 collimate_multiple, 10, wfsc 47-53 GSmag=12.3, Seeing 1.5" - 2"
- Z11's: -1055, -521, -108, -46, -10
- Seeing 1"
10:17 Switch
OFF background subtraction to wfsc_remove_bg
10:05 preset AO656, GUIDE, GS=0, PA=-90, acq=55 LUT = 1.4
10:05 collimate_multiple, 10, wfsc 57-58 GSmag=12.3, Seeing 1"
10:17 preset AO656, GUIDE, GS=20, PA=-90, acq=55 LUT = 1.4
10:q7 collimate_multiple, 10, wfsc 59-61 GSmag=16.0, Seeing 1"
10:21 Switch
ON background subtraction to wfsc_remove_bg
10:21 collimate_multiple, 10, wfsc 63-69 GSmag=16.0, Seeing 1"
- Z11: 280, 359, 133, 255, 152, 431
10:27 Switch
OFF background subtraction to wfsc_remove_bg
10:27 collimate_multiple, 10, wfsc 71-76 GSmag=16.0, Seeing 1"
- Z11: -1006, -436, -130. -62
10:31 Switch
ON old background subtraction (average of corners)
10:31 collimate_multiple, 10, wfsc 78-83 GSmag=16.0, Seeing 1"
- Z11: 27, -10, -8, -28, 16, 1
- Same Z11 as no background subtraction
10:38 preset AO656, GUIDE, GS=0, PA=-90, acq=55 LUT = 1.4
10:31 collimate_multiple, 10, wfsc 85- GSmag=12.5, Seeing 1"
10:41 Collimated on-axis
Rested Shell Collimation
10:42 Rested shell, preset canceled
10:46 collimate_multiple, 1 Not Sent: wfsc #1
10:47 collimate_multiple, 10, /Send: wfsc #2-11 50-60 SH spots After wfsc 11 acquired left_guider #1
10:55 Set the Shell, take image guider #2
10:57 preset AO656, GUIDE, GS=0, PA=-90, acq=55 LUT = 1.4
10:58 collimate_multiple, 10, /Send: wfsc #12-17, Collimated
11:03 Rested shell, preset canceled
11:04 guider 3
11:04 collimate_multiple, 10, /SEND wfsc 19-28
wfsc # |
guider # |
19 |
4 |
21 |
5 |
22 |
6 |
24 |
7 |
25 |
8 |
26 |
9 |
11:12 Set Shell
11:15 preset AO656, GUIDE, GS=0, PA=-90, acq=55 LUT = 1.4
11:16 collimate_multiple, 10, /SEND wfsc 29-39
11:24 Rest Shell
11:16 collimate_multiple, 10, /SEND wfsc 42-48
11:24 guider 10
wfsc # |
guider # |
42 |
11 |
44 |
12 |
47 |
13 |
11:12 Set Shell
11:15 preset AO656, GUIDE, GS=0, PA=-90, acq=55 LUT = 1.4
11:16 collimate_multiple, 10, /SEND wfsc -54
11:37 Rest Shell
11:37 collimate_multiple, 10, /SEND wfsc 56-60
wfsc # |
guider # |
57 |
14 |
58 |
15 |
Not many drops. ave-2*sigma sometimes less than 0
11:42 change to ave[0]/2.0
11:42 collimate_multiple, 10, /SEND wfsc 62
wfsc # |
guider # |
61 |
16 |
64 |
17 |
11:45 Close Chamber, go to sleep
--
DougMiller - 29 May 2012