You are here: Foswiki>Commissioning Web>Com20120207 (10 Feb 2012, JuanGuerra)Edit Attach

UT 20120207 - AO2 commissioning @ LBBG

Observer: KBoutsia, JHill (Tucson), JCarlos (LBTO)
Telescope Operator: DHuerta (LBTO)
Additional AO Support: SEsposito, EPinna, APuglisi, MXompero
Telescope Support: JUrban(LBTO)
Instrument Support: DOfficer (LBTO)

Summary

Late start because of clouds. We start opening dome at around 3:00UT.
Sky conditions poor; cloudy Pisces ND holder plate was aligned, remains on sky test with the ND filter

Note: There were some parallel/parasitic measurements with AO2 during the previous night Commissioning.Com20120206 .

Details

03:05 Opening dome

CLOSE LOOP PERFORMANCES

IDL> PRESET. bright star BIN 1 mag.7.5
     >iif_preset,'AO1071',GS=3,RS=0,MODE=ACE,PIPPO,PA=180
  
      # Target star: 0   AO1071
        05:38:11.1470 +51:26:45.940 RADEC 2000.0 J2000 0.0 0.0 7.20 R 1.36 B_V 1.65
      # Guide star: 3
        05:38:03.4398 +51:25:25.709 RADEC 2000.0 J2000 0.0 0.0 11.01 R 0.81 B_V 0.63
      # AO Reference star: 0
        05:38:11.1470 +51:26:45.940 RADEC 2000.0 J2000 0.0 0.0 7.20 U 1.36 B_V 0.5jhill
 
Prest in ACE mode using the iif. The preset end ok, but the command didn't go to the TCS and the AO system. Doug M was called, probably is na error in IDL that try to connect to the IRTC, authorization.

The close loop was done using the AOS.

The system works well closing the loop giving a performance of about between 80%-90%

05:44 Telescope to zentih. stop the three house.

6:06 PRESET. bright star BIN 1 mag.7.5 preset to AO305 from TCS.


IDL> iif_preset,'AO305',GS=3,RS=0,MODE=ACE,PIPPO,PA=180
  
      # Target star: 0   AO305
        08:48:01.3477 +39:35:50.664 RADEC 2000.0 J2000 0.0 0.0 7.18 R 2.39 B_V 1.65
      # Guide star: 3
        08:47:46.5260 +39:34:09.030 RADEC 2000.0 J2000 0.0 0.0 14.57 R 1.01 B_V 0.63
      # AO Reference star: 0
        08:48:01.3477 +39:35:50.664 RADEC 2000.0 J2000 0.0 0.0 7.18 U 2.39 B_V 0.5
 


IDL> iif_runao
% Compiled module: IIF_RUNAO.
      runao: closing the AO loop
% Compiled module: IRC_RUNAO.

Preset Success.

06:50 CLOSE DOME. Cloudy. Total cover sky.

11:37 OPEN DOME

preset AO470 mag.7

Close the loop using the AOS.

The iif didn't work, the preset was received ok in the telescope , but there was a difference in the pointing between a poiting used by the TO and the pointing used with the iif. pointing with the TO (mode active), the reference star is in the CCD47 fov, instead if the preset is sent by the iif the star moves away from the CCD47 fov

IDL> iif_preset,'AO470',GS=3,RS=0,MODE=ACTIVE,PIPPO,PA=180
  
      # Target star: 0   AO470
        12:29:41.3887 +41:59:32.180 RADEC 2000.0 J2000 0.0 0.0 9.11 R 2.49 B_V 1.65
      # Guide star: 3
        12:29:50.1217 +41:56:41.211 RADEC 2000.0 J2000 0.0 0.0 10.91 R 0.71 B_V 0.63
 

IDL> iif_preset,'AO860',GS=1,RS=0,MODE=ACE,PIPPO,PA=180
  
      # Target star: 0   AO860
        12:22:20.6870 +25:10:09.449 RADEC 2000.0 J2000 0.0 0.0 10.40 R 2.30 B_V 1.65
      # Guide star: 1
        12:22:24.1615 +25:08:22.268 RADEC 2000.0 J2000 0.0 0.0 10.68 R 0.61 B_V 0.63
      # AO Reference star: 0
        12:22:20.6870 +25:10:09.449 RADEC 2000.0 J2000 0.0 0.0 10.40 U 2.30 B_V 0.5
  
Failure due to CCD39 not live.

IDL> iif_preset,'AO860',GS=1,RS=0,MODE=ACE,PIPPO,PA=180
  
      # Target star: 0   AO860
        12:22:20.6870 +25:10:09.449 RADEC 2000.0 J2000 0.0 0.0 10.40 R 2.30 B_V 1.65
      # Guide star: 1
        12:22:24.1615 +25:08:22.268 RADEC 2000.0 J2000 0.0 0.0 10.68 R 0.61 B_V 0.63
      # AO Reference star: 0
        12:22:20.6870 +25:10:09.449 RADEC 2000.0 J2000 0.0 0.0 10.40 U 2.30 B_V 0.5
 

 
IDL> iif_runao
      runao: closing the AO loop
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = IDL File error
        err = Resmsg[2]  = AcquireRef[167] failed - IDL File errorpreset, AO860, MODE=ACE, GS=1, RS=0, PA=180

Failure from the WFS side.

IDL> iif_preset,'AO860',GS=1,RS=0,MODE=ACE,PIPPO,PA=180preset, AO860, MODE=ACE, GS=1, RS=0, PA=180
  
      # Target star: 0   AO860
        12:22:20.6870 +25:10:09.449 RADEC 2000.0 J2000 0.0 0.0 10.40 R 2.30 B_V 1.65
      # Guide star: 1
        12:22:24.1615 +25:08:22.268 RADEC 2000.0 J2000 0.0 0.0 10.68 R 0.61 B_V 0.63
      # AO Reference star: 0
        12:22:20.6870 +25:10:09.449 RADEC 2000.0 J2000 0.0 0.0 10.40 U 2.30 B_V 0.5
  

  
IDL> iif_runao
      runao: closing the AO loop
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = AcquireRef[170] failed - Command timeout - -13107: Arbitrator interface generic error
IDL> 

Failure from the WFS side.

The loop is close from the WFS side.

ND holder plate align and left in place. On hold till we can align on sky or using the retro-relector.

The pinhole is aligned in teh center of Pisces image. The pinhole was centered first in the ND holder and moving the plate we could center the pinhole in the center of :Pisces image. * Imae: pisces.20120207.0069,70,71.fits. The image below shows the center of the pinhole. Pisces.20120207.0071.fits

pinhole.png

13:13 CLOSE DOME. Cloudy, total sky cover

13:13 END OF THE NIGHT.

-- JohnHill - 07 Feb 2012
  • Pinhole center in the ND holder:
    pinhole.png
Topic attachments
I Attachment Action SizeSorted ascending Date Who Comment
pinhole.pngpng pinhole.png manage 298 K 10 Feb 2012 - 18:45 UnknownUser Pinhole center in the ND holder
Topic revision: r7 - 10 Feb 2012, JuanGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback