UT 20120205 AO/PISCES technical night
Observer: DMiller (tucson), JCarlos (LBTO)
Telescope Operator: DHuerta (LBTO)
Telescope Support: JUrban(LBTO)
Instrument Support: DOfficer (LBTO)
Summary
-Test of the new preset modes to close the loop and apply offsets during the close loop. Several presets were sent with a good success in most all of them. The last preset, early in the morning failed during the autogain procedure, this was due to a bad seeing ~1.3" and the high background
-Check performances of the close loop.
-Check PSF quality in Pisces, the images showed a poor psf, this has to be investigated tomorrow (morning).
Details
First half was TCS Testing with TCS Build 2012B. TCS was reverted to BP14 for the second half.
Clouds passing. good seeing ~0.8" till the last hour where the seeing was about 1.3".
9:10 Opened chamber
Target in the ND holder plate.
We had a few minutes to check the ND holder plate using a diffuse source. The source is a piece of paper that cover the ND holder with a small hole in the center illuminated by a torch.
A few images were taken and this test will be done tomorrow with more time to center and to fix the position for the ND holder plate.
Filter positions.
Images taken with 20 seconds exposure used to identify the filters posiitons. The table below shows the new positions..
filter |
band |
image |
#9 |
Open |
pisces.20120205.0015.fits |
0 |
dark |
pisces.20120205.0005,16.fits |
1 |
J |
pisces.20120205.0007,17.fits |
2 |
Ks |
pisces.20120205.0008,18.fits |
3 |
H |
pisces.20120205.0009,19.fits |
4 |
Br-gm |
pisces.20120205.0010,20.fits |
5 |
FeII |
pisces.20120205.0011.fits |
6 |
2.046um |
pisces.20120205.0012.fits |
7 |
2.14um |
pisces.20120205.0013.fits |
8 |
H2 |
pisces.20120205.0014.fits |
long exposure images.
During the close dome we took a serie of images with light ON/OFF. The filter used was J. The test to check any possible vignetting in the optical path of Pisces.
image |
exptime(sec) |
light |
pisces.20120205.0021,22 |
120 |
ON |
pisces.20120205.0023,24 |
120 |
OFF |
pisces.20120205.0025 |
240 |
ON |
pisces.20120205.0026 |
240 |
OFF |
Defocused images.
Preset to AO439.
Offset to center the star in the middle RA=10 DEC=5.
images taken:
offset RA,DEC (arcsec) |
image |
position |
10 -2 |
pisces.20120205.0029.fits |
offset 10,-3 image: pisces.20120205.0033.fits
offset 10 -5
* Image of a defocus star, it is hard to identify a clear pupil image.
10:06 Preset AO365
Offset along the detector. Images
10:45 First
AdaptiveAce_Active preset
# Test of observing script
# 21Jun2011 DLM
header, PARTNER=ARIZONA, OBSERVER='Miller', OBJECT=AO366
preset, OBJECT=AO366, MODE=ace, GS=1, RS=0, PA=37
auto_collimate
runao
- 5.2 mag in H
- Success. object in upper left quadrant, on the edge
- bin1,
- /newdata/pisces.20120205.00543fits J Saturated
- offset, -10, -8, DETXY, object near the center
- /newdata/pisces.20120205.0054.fits J Much Dimmer!!
- offset, -2, 0, DETXY, object off edge now
- /newdata/pisces.20120205.0055.fits J saturated
11:10 Second
AdaptiveAce_Active preset
# Test of observing script
# 21Jun2011 DLM
header, PARTNER=ARIZONA, OBSERVER='Miller', OBJECT=AO376
preset, OBJECT=AO376, MODE=ace, GS=4, RS=0, PA=37
auto_collimate
runao
- 8.2 mag in H
- bin 2, 990 Hz
- Success. object not seen
- /newdata/pisces.20120205.0056.fits J bject not seen
- offset, -2, 0, DETXY
- /newdata/pisces.20120205.0057.fits J object not seen
- offset, -6, 0, DETXY
- /newdata/pisces.20120205.0060.fits FeII object not seen
- offset, -14, -8, DETXY to move to center
- /newdata/pisces.20120205.0061.fits FeII object not seen
- /newdata/pisces.20120205.0062.fits K object not seen
- offset, -6, 0, DETXY
- /newdata/pisces.20120205.0063.fits K (3 sec) 29000 peak counts
- offset, -6, 2, DETXY
- /newdata/pisces.20120205.0064.fits K (3 sec) not seen
- offset, -6, 0, DETXY
- /newdata/pisces.20120205.0063.fits K (3 sec) 29000 peak counts
- offset, -6, -1, DETXY
- /newdata/pisces.20120205.0065.fits K (3 sec) 5000 peak counts
- offset, -18, 0, DETXY Lower left quadrant
- /newdata/pisces.20120205.00568.fits K (3 sec) Saturated
12:02 third
AdaptiveAce_Active preset R=14.2
# Test of observing script
# 21Jun2011 DLM
header, PARTNER=ARIZONA, OBSERVER='Miller', OBJECT=AO476
preset, OBJECT=AO476, MODE=ace, GS=5, RS=0, PA=62
auto_collimate
runao
- 9.6 mag in H
- bin 2, 400 Hz
- Success. object not seen
- /newdata/pisces.20120205.0070.fits K Open loop, top left edge
- offset, -6, 0, DETXY
- /newdata/pisces.20120205.0073.fits K (3 sec) 1000 counts peak
- offset, -14, -8, DETXY
- /newdata/pisces.20120205.0074.fits K (3 sec) not seen
- /newdata/pisces.20120205.0075.fits K (60 sec) not seen
12:29 fourth
AdaptiveAce_Active preset R=15.7
# Test of observing script
# 21Jun2011 DLM
header, PARTNER=ARIZONA, OBSERVER='Miller', OBJECT=AO457
preset, OBJECT=AO457, MODE=ace, GS=1, RS=0, PA=20
auto_collimate
runao
- 10.9 in H
- bin 3, 199 Hz
- offset, -6, 0, DETXY
- /newdata/pisces.20120205.0076.fits K (3 sec) not seen
- /newdata/pisces.20120205.0077.fits K (60 sec) not seen
- offset, -18, 0, DETXY
- /newdata/pisces.20120205.0078.fits K (15 sec) 26000 peak counts
- offset, -13, 0, DETXY
- /newdata/pisces.20120205.0079.fits K (3 sec) 20 counts over background
12:29 fifth
AdaptiveAce_Active preset R=15.9
# Test of observing script
# 21Jun2011 DLM
header, PARTNER=ARIZONA, OBSERVER='Miller', OBJECT=AO384
preset, OBJECT=AO384, MODE=ace, GS=3, RS=0, PA=36
auto_collimate
runao
- 10.6 H mag
- bin 4, 311 Hz
- Success.
- /newdata/pisces.20120205.0080.fits K (15 sec) object not seen
- offset, -18, 0, DETXY
- /newdata/pisces.20120205.0081.fits K (15 sec) 7000 peak counts
- offset, -18, -2, DETXY
- /newdata/pisces.20120205.0082.fits K (15 sec) 2000 peak counts
- /newdata/pisces.20120205.0083.fits K (15 sec) 2000 peak counts
13:08 fifth
AdaptiveAce_Active preset R=13.7
# Test of observing script
# 21Jun2011 DLM
header, PARTNER=ARIZONA, OBSERVER='Miller', OBJECT=M53
preset, OBJECT=M53, MODE=ace, GS=9, RS=0, PA=10
auto_collimate
runao
- Dimm = 0.8" seeing
- 11.11 H mag
- bin 3, 399 Hz
- /newdata/pisces.20120205.0084.fits K (15 sec) open loop
- /newdata/pisces.20120205.0085.fits K (15 sec) 700 peak counts
- offset, 0, -5, DETXY
- /newdata/pisces.20120205.0086.fits K (10 sec) 2000 peak counts
- /newdata/pisces.20120205.0086.fits K (10 sec) 2000 peak counts
- /newdata/pisces.20120205.0088.fits K (60 sec) Open Loop
13:25 ADI preset
# Test of observing script
# 21Jun2011 DLM
header, PARTNER=ARIZONA, OBSERVER='Miller', OBJECT=AO493
preset, OBJECT=AO493, MODE=acquire, GS=0, RS=0, PA=-10
pause
preset, OBJECT=AO493, MODE=ace, GS=6 RS=0, PA=-10, ROT=PARALLACTIC
auto_collimate
runao
- rotator at 170. Need to calculate PA for PARALLACTIC mode rather than POSITION mode
- Failed: Shell Ripped. Lost communication to slope computer. JC restarted slope computer process and BCU 39 restarted
13:35 Send just ADAPTIVEACE_TRACK
# Test of observing script
# 21Jun2011 DLM
header, PARTNER=ARIZONA, OBSERVER='Miller', OBJECT=AO493
preset, OBJECT=AO493, MODE=ace, GS=6 RS=0, PA=-20, ROT=PARALLACTIC
runao
- Failed during Auto-gain procedure. Max skips reached, Stopping WFS, Stopping AdSec
- ADI mode seemed to work
13:40 Closing
13:48 Pisces deactivated
With the problems due to the bas quality of the Pisces images we used teh elab tool to check the performances. Below is a table of the perfomarnce and a modal plot.
The quality of the loop close could be seen in the CCD47, where diffraction images could be seeing. Unfortunally the images were not saved.
After talking with the Arcetri Team, the note in the elab are not true, this is a wrong information from the elab. An issue track was activated: n#3939
TrackNo |
RefStar |
Mag |
El |
Wind |
DIMM/OL |
Rec |
bin |
#mod |
freq |
gain |
mod |
nph |
AntiDrift |
SR |
filter |
exp |
#frames |
disturb |
SN |
notes |
20120205_130727 |
??? |
14.9 |
48 |
11 |
NaN 0.75 |
083227 |
4 |
36 |
312 |
3.4 1.5 0.8 |
6 |
39 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_130241 |
??? |
14.9 |
49 |
13 |
NaN 0.81 |
083227 |
4 |
36 |
312 |
3.4 1.5 0.8 |
6 |
40 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_130340 |
??? |
14.9 |
49 |
13 |
NaN 0.69 |
083227 |
4 |
36 |
312 |
3.4 1.5 0.8 |
6 |
41 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_130555 |
??? |
14.9 |
49 |
11 |
NaN 0.80 |
083227 |
4 |
36 |
312 |
3.4 1.5 0.8 |
6 |
40 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_125751 |
??? |
14.9 |
50 |
13 |
NaN 0.93 |
083227 |
4 |
36 |
312 |
3.4 1.5 0.8 |
6 |
40 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_125938 |
??? |
14.9 |
50 |
9 |
NaN 1.04 |
083227 |
4 |
36 |
312 |
3.4 1.5 0.8 |
6 |
39 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_110328 |
??? |
8.2 |
58 |
11 |
NaN 0.42 |
092604 |
1 |
400 |
990 |
0.9 0.7 0.7 |
3 |
319 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
- Pupils mismatch |
20120205_114134 |
??? |
11.5 |
58 |
11 |
NaN 0.77 |
180534 |
2 |
145 |
991 |
1.4 0.5 0.4 |
3 |
65 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_105438 |
??? |
8.2 |
60 |
11 |
NaN 0.57 |
092604 |
1 |
400 |
990 |
0.9 0.7 0.7 |
3 |
313 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
- Pupils mismatch |
20120205_105506 |
??? |
8.2 |
60 |
11 |
NaN 0.55 |
092604 |
1 |
400 |
990 |
0.9 0.7 0.7 |
3 |
314 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
- Pupils mismatch |
20120205_124803 |
??? |
14.6 |
61 |
13 |
1.21 0.61 |
075552 |
3 |
66 |
200 |
2.7 1.2 1.0 |
6 |
40 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_112505 |
??? |
11.5 |
62 |
11 |
NaN 0.48 |
180534 |
2 |
145 |
991 |
1.4 0.5 0.4 |
3 |
64 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_124442 |
??? |
14.7 |
62 |
12 |
1.07 0.56 |
075552 |
3 |
66 |
200 |
2.7 1.2 1.0 |
6 |
39 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_131919 |
??? |
13.9 |
62 |
8 |
0.92 0.56 |
075552 |
3 |
66 |
400 |
2.7 0.9 0.9 |
7 |
40 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
- Pyramid modulation mismatch |
20120205_132044 |
??? |
14.0 |
62 |
11 |
1.58 0.61 |
075552 |
3 |
66 |
400 |
2.7 0.9 0.9 |
7 |
37 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
- Pyramid modulation mismatch |
20120205_122620 |
??? |
13.3 |
63 |
11 |
NaN 0.86 |
180534 |
2 |
145 |
400 |
2.4 1.8 1.0 |
3 |
30 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_123936 |
??? |
14.6 |
63 |
11 |
NaN 0.53 |
075552 |
3 |
66 |
200 |
2.7 1.2 1.0 |
6 |
41 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_124223 |
??? |
14.6 |
63 |
11 |
NaN 0.56 |
075552 |
3 |
66 |
200 |
2.7 1.2 1.0 |
6 |
40 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_131514 |
??? |
13.9 |
63 |
7 |
NaN 0.75 |
075552 |
3 |
66 |
400 |
2.7 0.9 0.9 |
7 |
40 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
- Pyramid modulation mismatch |
20120205_131558 |
??? |
13.9 |
63 |
9 |
NaN 0.56 |
075552 |
3 |
66 |
400 |
2.7 0.9 0.9 |
7 |
40 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
- Pyramid modulation mismatch |
20120205_121733 |
??? |
13.4 |
65 |
11 |
NaN 0.86 |
180534 |
2 |
145 |
400 |
2.4 1.8 1.0 |
3 |
28 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_121030 |
??? |
13.4 |
66 |
10 |
NaN 0.77 |
180534 |
2 |
145 |
400 |
2.4 1.8 1.0 |
3 |
27 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
20120205_121214 |
??? |
13.3 |
66 |
11 |
NaN 0.86 |
180534 |
2 |
145 |
400 |
2.4 1.8 1.0 |
3 |
30 |
ON |
-1.0 |
? |
-1 |
-1 |
ONSKY |
NO |
|
Modal plot.
Condensation on the Pisces entrance window. Effect to the image quality
--
JuanGuerra - 05 Feb 2012
- Modal plot bin 2:
- Image at close loop of the resulting PSF with condensation on the entrance window:
- Condensation, the image shows the creation of ice, this has been remove using the dry air hose:
- Defocuse bright star:
- Image offset to the center_with condensation: