Dice5 Results
- Data were collected on January 7th/12th (full nights) and 11th/13th (half nights), 2012
Data Collection
Elevation |
Preset |
Guiding/Collimation |
Dice5 (1x1) |
Dice5 (10x10) |
30 |
4,IV,X,9a |
4,IV,X,9a |
5,VI,10a |
6,V,XI |
45 |
8.a,g,1a,11a |
8,a,g,1a,11a |
c,3a,13a |
b,2a,12a |
60 |
7,12,VII,d,6a |
7,12,VII,d,6a |
2,13,IX,7a |
3,14,VIII,e,8a |
70 |
1,I,XII,4a |
1,I,XII,4a |
III,f,5a |
II,XIII |
80 |
9 |
9 |
10 |
11 |
*NOTE* References 1-14 are from 20120107.
*NOTE* References I-XIII are from 20120111.
*NOTE* References a-g are from 20120112.
*NOTE* References 1a-13a are from 20120113.
Results
Small (1") and Medium (10") Offset Accuracy
|
Dice5 (1"x1") |
Elevation |
Ra Sigma |
Dec Sigma |
Average Distance |
Ellipticity |
FWHM |
30 |
62.89 |
55.11 |
70.31 |
0.11 +- 0.05 |
0.86 +- 0.24 |
45 |
69.71 |
69.74 |
88.75 |
0.11 +- 0.06 |
0.80 +- 0.16 |
60 |
39.95 |
39.29 |
50.03 |
0.10 +- 0.04 |
0.60 +- 0.10 |
70 |
54.12 |
38.30 |
59.24 |
0.09 +- 0.06 |
0.55 +- 0.10 |
80 |
48.12 |
53.49 |
75.71 |
0.15 +- 0.06 |
0.81 +- 0.10 |
Full Set Average |
56.61 |
52.46 |
66.49 |
|
=> Sigma values measured in milliarcsec
|
Dice5 (10"x10") |
Elevation |
Ra Sigma |
Dec Sigma |
Average Distance |
Ellipticity |
FWHM |
30 |
53.43 |
71.69 |
81.46 |
0.10 +- 0.05 |
0.85 +- 0.22 |
45 |
75.22 |
65.05 |
89.83 |
0.12 +- 0.05 |
0.80 +- 0.12 |
60 |
70.45 |
54.56 |
75.71 |
0.12 +- 0.06 |
0.67 +- 0.10 |
70 |
80.74 |
75.07 |
104.17 |
0.11 +- 0.07 |
0.94 +- 0.32 |
80 |
51.78 |
44.33 |
57.10 |
0.14 +- 0.07 |
0.89 +- 0.24 |
Full Set Average |
71.48 |
64.54 |
83.06 |
|
=> Sigma values measured in milliarcsec
- Dice5 Results for LBBG 2012 - offset pattern:
- Dice5 Results for LBBG 2012 - elevation:
Single Set Statistics
20120113 |
dice5 |
RaAve. |
DecAve. |
DistAve |
ellip |
fwhm |
10_45a |
-0.06410 +- 0.09388 |
0.01875 +- 0.06976 |
0.11946 +- 0.05885 |
0.15024 +- 0.06472 |
0.73886 +- 0.07460 |
10_45b |
-0.03483 +- 0.04477 |
0.00015 +- 0.03752 |
0.05976 +- 0.03091 |
0.08496 +- 0.03198 |
0.74143 +- 0.08974 |
10_60a |
-0.03353 +- 0.10942 |
0.00347 +- 0.07733 |
0.12401 +- 0.05581 |
0.11972 +- 0.04460 |
0.63450 +- 0.07157 |
1_30a |
0.03872 +- 0.08118 |
-0.03773 +- 0.05642 |
0.09728 +- 0.05442 |
0.12640 +- 0.04473 |
1.16728 +- 0.12312 |
1_45a |
-0.05153 +- 0.05974 |
-0.00681 +- 0.06006 |
0.08260 +- 0.05369 |
0.13524 +- 0.05662 |
0.78309 +- 0.15976 |
1_45b |
0.01320 +- 0.07172 |
-0.03309 +- 0.07356 |
0.09763 +- 0.04413 |
0.07292 +- 0.03787 |
0.89568 +- 0.15202 |
1_60a |
-0.01179 +- 0.05520 |
-0.01374 +- 0.03207 |
0.05831 +- 0.02957 |
0.10484 +- 0.03404 |
0.63816 +- 0.07188 |
1_70a |
-0.02027 +- 0.05699 |
0.00137 +- 0.03045 |
0.05754 +- 0.03400 |
0.07052 +- 0.04141 |
0.46922 +- 0.08584 |
all |
-0.02051 +- 0.07971 |
-0.00845 +- 0.05920 |
0.08707 +- 0.05228 |
|
|
#
20120112 |
dice5 |
RaAve. |
DecAve. |
DistAve |
ellip |
fwhm |
10_45a |
-0.00553 +- 0.06957 |
-0.04205 +- 0.06891 |
0.09028 +- 0.05452 |
0.13976 +- 0.03702 |
0.90643 +- 0.10431 |
10_60a |
-0.01299 +- 0.04374 |
-0.03230 +- 0.06408 |
0.07246 +- 0.03971 |
0.23682 +- 0.06104 |
0.82606 +- 0.10384 |
1_45a |
-0.00438 +- 0.06275 |
-0.00300 +- 0.07363 |
0.08601 +- 0.04102 |
0.13204 +- 0.06486 |
0.73255 +- 0.13019 |
1_70a |
0.00682 +- 0.04391 |
-0.00071 +- 0.05017 |
0.05940 +- 0.02861 |
0.10856 +- 0.07589 |
0.61532 +- 0.08256 |
all |
-0.00256 +- 0.05737 |
-0.01744 +- 0.06645 |
0.07778 +- 0.04359 |
|
|
#
20120111 |
dice5 |
RaAve. |
DecAve. |
DistAve |
ellip |
fwhm |
10_30a |
-0.00268 +- 0.03940 |
-0.03393 +- 0.04496 |
0.06183 +- 0.02827 |
0.11356 +- 0.04355 |
0.80495 +- 0.12230 |
10_30b |
0.04044 +- 0.06720 |
0.07983 +- 0.06883 |
0.12149 +- 0.04711 |
0.08888 +- 0.03813 |
1.09455 +- 0.14814 |
10_60a |
0.01885 +- 0.05764 |
-0.00091 +- 0.03749 |
0.06281 +- 0.03145 |
0.09864 +- 0.04241 |
0.63352 +- 0.08813 |
10_70a |
-0.01848 +- 0.09468 |
-0.00832 +- 0.07844 |
0.10660 +- 0.06074 |
0.11179 +- 0.06924 |
1.20476 +- 0.22712 |
10_70b |
-0.06116 +- 0.05931 |
0.00744 +- 0.07244 |
0.10184 +- 0.04378 |
0.11536 +- 0.06701 |
0.68524 +- 0.11024 |
1_30a |
-0.00739 +- 0.03998 |
0.00620 +- 0.04530 |
0.05227 +- 0.03002 |
0.11680 +- 0.02699 |
0.69163 +- 0.05788 |
1_60a |
-0.00528 +- 0.04009 |
-0.01715 +- 0.04893 |
0.05653 +- 0.03175 |
0.10828 +- 0.03840 |
0.70291 +- 0.09892 |
1_70a |
-0.01325 +- 0.05203 |
-0.01520 +- 0.04387 |
0.06094 +- 0.03445 |
0.10640 +- 0.05854 |
0.57183 +- 0.06726 |
all |
-0.00606 +- 0.06391 |
0.00230 +- 0.06437 |
0.07789 +- 0.04661 |
|
|
#
20120107 |
dice5 |
RaAve. |
DecAve. |
DistAve |
ellip |
fwhm |
10_60a |
-0.01837 +- 0.04792 |
0.00226 +- 0.05173 |
0.06145 +- 0.03737 |
0.10336 +- 0.05430 |
0.70674 +- 0.07125 |
10_80a |
-0.00910 +- 0.05178 |
0.02579 +- 0.04433 |
0.05710 +- 0.04505 |
0.14508 +- 0.06996 |
0.88949 +- 0.23946 |
10_60b |
-0.01916 +- 0.04571 |
0.00891 +- 0.02757 |
0.04980 +- 0.02654 |
0.08342 +- 0.02972 |
0.63620 +- 0.11088 |
10_30a |
0.02140 +- 0.04197 |
0.01578 +- 0.04808 |
0.06106 +- 0.03044 |
0.10272 +- 0.05525 |
0.65616 +- 0.10536 |
1_60a |
0.00453 +- 0.02850 |
-0.00756 +- 0.04356 |
0.04657 +- 0.02306 |
0.11068 +- 0.03841 |
0.54695 +- 0.04969 |
1_80a |
0.01403 +- 0.04812 |
-0.03706 +- 0.05349 |
0.07571 +- 0.02900 |
0.14876 +- 0.05608 |
0.81334 +- 0.09677 |
1_60b |
-0.01065 +- 0.03073 |
-0.00017 +- 0.02956 |
0.03871 +- 0.01937 |
0.06440 +- 0.03270 |
0.53111 +- 0.04011 |
1_30a |
0.02339 +- 0.05345 |
0.00740 +- 0.05247 |
0.06138 +- 0.04809 |
0.07860 +- 0.05452 |
0.71993 +- 0.12490 |
all |
0.00137 +- 0.04644 |
0.00170 +- 0.04790 |
0.05668 +- 0.03503 |
|
|
Guider Corrections for 20120107 UT
- Guiding X/Y corrections for 20120107 UT:
- FWHM and Guider correction variations for 20120107 - all night::
Guider Corrections for 20120111 UT
- FWHM and Guider correction variations for 20120107 - 2nd half:::
Guider Corrections for 20120112 UT
* FWHM and Guider correction variations for 20120112 - 1st half:
Guider Corrections for 20120113 UT
- FWHM and Guider correction variations for 20120113 - 1st half:
LDG Guider Corrections for 20120120-21 UT
- Guiding corrections for LDG in the same period for comparison:
--
DougMiller - 14 Jan 2012
- Guider FWHM vs Average Correction for LBBG:
- LBBG Collimation:
20120113 |
dice5 |
RaAve. |
DecAve. |
DistAve |
ellip |
fwhm |
10_45a |
-0.064 +- 0.094 |
0.017 +- 0.07076 |
0.119 +- 0.059 |
0.150 +- 0.065 |
0.739 +- 0.075 |
10_45b |
-0.035 +- 0.045 |
0.000 +- 0.038 |
0.060 +- 0.031 |
0.085 +- 0.032 |
0.741 +- 0.090 |
10_60a |
-0.033 +- 0.109 |
0.003 +- 0.077 |
0.124 +- 0.056 |
0.120 +- 0.045 |
0.634 +- 0.072 |
1_30a |
0.039 +- 0.081 |
-0.038 +- 0.056 |
0.097 +- 0.054 |
0.126 +- 0.045 |
1.167 +- 0.123 |
1_45a |
-0.052 +- 0.060 |
-0.007 +- 0.060 |
0.083 +- 0.054 |
0.135 +- 0.057 |
0.783 +- 0.160 |
1_45b |
0.013 +- 0.072 |
-0.033 +- 0.074 |
0.098 +- 0.044 |
0.073 +- 0.038 |
0.896 +- 0.152 |
1_60a |
-0.012 +- 0.055 |
-0.014 +- 0.032 |
0.058 +- 0.030 |
0.105 +- 0.034 |
0.638 +- 0.072 |
1_70a |
-0.020 +- 0.057 |
0.001 +- 0.030 |
0.057 +- 0.034 |
0.071 +- 0.041 |
0.469 +- 0.086 |
all |
-0.021 +- 0.080 |
-0.008 +- 0.059 |
0.087 +- 0.052 |
|
|
#
20120112 |
dice5 |
RaAve. |
DecAve. |
DistAve |
ellip |
fwhm |
10_45a |
-0.006 +- 0.070 |
-0.042 +- 0.069 |
0.090 +- 0.055 |
0.140 +- 0.037 |
0.906 +- 0.104 |
10_60a |
-0.013 +- 0.044 |
-0.032 +- 0.064 |
0.072 +- 0.039 |
0.237 +- 0.061 |
0.826 +- 0.104 |
1_45a |
-0.004 +- 0.063 |
-0.003 +- 0.074 |
0.086 +- 0.041 |
0.132 +- 0.065 |
0.732 +- 0.130 |
1_70a |
0.007 +- 0.044 |
-0.001 +- 0.050 |
0.059 +- 0.029 |
0.109 +- 0.076 |
0.615 +- 0.083 |
all |
-0.003 +- 0.057 |
-0.017 +- 0.066 |
0.078 +- 0.043 |
|
|
#
20120111 |
dice5 |
RaAve. |
DecAve. |
DistAve |
ellip |
fwhm |
10_30a |
-0.003 +- 0.039 |
-0.034 +- 0.045 |
0.062 +- 0.028 |
0.114 +- 0.044 |
0.805 +- 0.122 |
10_30b |
0.040 +- 0.067 |
0.080 +- 0.069 |
0.121 +- 0.047 |
0.089 +- 0.038 |
1.095 +- 0.148 |
10_60a |
0.019 +- 0.058 |
-0.001 +- 0.037 |
0.063 +- 0.031 |
0.099 +- 0.042 |
0.634 +- 0.088 |
10_70a |
-0.018 +- 0.095 |
-0.008 +- 0.078 |
0.107 +- 0.061 |
0.112 +- 0.069 |
1.205 +- 0.227 |
10_70b |
-0.061 +- 0.059 |
0.007 +- 0.072 |
0.102 +- 0.044 |
0.115 +- 0.067 |
0.685 +- 0.110 |
1_30a |
-0.007 +- 0.040 |
0.006 +- 0.045 |
0.052 +- 0.030 |
0.117 +- 0.027 |
0.692 +- 0.058 |
1_60a |
-0.005 +- 0.040 |
-0.017 +- 0.049 |
0.057 +- 0.032 |
0.108 +- 0.038 |
0.703 +- 0.099 |
1_70a |
-0.013 +- 0.052 |
-0.015 +- 0.044 |
0.061 +- 0.034 |
0.106 +- 0.059 |
0.572 +- 0.067 |
all |
-0.006 +- 0.06391 |
0.002 +- 0.064 |
0.078 +- 0.047 |
|
|
#
20120107 |
dice5 |
RaAve. |
DecAve. |
DistAve |
ellip |
fwhm |
10_60a |
-0.018 +- 0.048 |
0.002 +- 0.052 |
0.061 +- 0.037 |
0.103 +- 0.054 |
0.707 +- 0.071 |
10_80a |
-0.009 +- 0.052 |
0.026 +- 0.044 |
0.057 +- 0.045 |
0.145 +- 0.070 |
0.889 +- 0.239 |
10_60b |
-0.019 +- 0.046 |
0.009 +- 0.028 |
0.050 +- 0.026 |
0.083 +- 0.030 |
0.636 +- 0.111 |
10_30a |
0.021 +- 0.042 |
0.016 +- 0.048 |
0.061 +- 0.030 |
0.103 +- 0.055 |
0.656 +- 0.105 |
1_60a |
0.005 +- 0.028 |
-0.008 +- 0.044 |
0.047 +- 0.023 |
0.111 +- 0.038 |
0.547 +- 0.050 |
1_80a |
0.014 +- 0.048 |
-0.037 +- 0.053 |
0.076 +- 0.029 |
0.149 +- 0.056 |
0.813 +- 0.097 |
1_60b |
-0.011 +- 0.031 |
-0.000 +- 0.030 |
0.039 +- 0.019 |
0.064 +- 0.033 |
0.531 +- 0.040 |
1_30a |
0.023 +- 0.053 |
0.007 +- 0.052 |
0.061 +- 0.048 |
0.079 +- 0.054 |
0.720 +- 0.125 |
all |
0.001 +- 0.046 |
0.002 +- 0.048 |
0.057 +- 0.035 |
|
|