UT 20120107 LBC Technical Observations

Observer: DMiller(@LBTO), KBoutsia (Tucson)
Telescope Operator: DGonzalez Huerta
Instrument Support: JMorris
Telescope Support:
SW support:

Summary

Clear sky with seeing <1.0'' for most of the night.
Measured the rotator center of the IRTC and AGw, since the previous values were obtained during bad seeing conditions.
Several transform datasets have been collected and a new transformation has been calculated and implemented.
The rms of the final transformation is of the order of 50micron and it is half of what had been previously estimated. The transform data obtained with the new transformation confirm these values. The data set to check the new transformation give xrms=39 and yrms=37. Maybe Jesper can get a better fit to the data than can I (Doug)
Several collimation and dice5 datasets were also collected in various elevations.

Elevation Preset Guiding/Collimation Dice5 (1x1) Dice5 (10x10)
30 col_30a col_30a dice5_1_30a dice5_10_30a
45 col_50a, col_50b col_50a, col_50b    
60 col_60a, col_60b col_60a, col_60b dice5_1_60a, dice5_1_60b dice5_10_60a, dice5_10_60b
75 col_70a, col_80a col_70a, col_80a dice5_1_80a dice5_10_80a

The irtc data were being written in /newdata, but not digested by the archive. Thus they are not in /Repository/20120107. I created data subdirectories for all the data sets we have and copied the irtc data from /newdata to these directories (eg /OldRepository/AGW_Data/20120107/transform_I/data).

Preliminary Dice5 results for tonight

Dice5 (1"x1")          
Elevation Ra Sigma Dec Sigma Aver. Distance Ellipticity FWHM
30 53.45 52.47 61.38 0.08 +- 0.05 0.72 +- 0.12
60 30.32 37.03 42.64 0.09 +- 0.04 0.54 +- 0.04
80 48.12 53.49 75.71 0.15 +- 0.06 0.81 +- 0.10
Full Set Average 42.89 48.16 55.59    

Dice5 (10"x10")          
Elevation Ra Sigma Dec Sigma Aver. Distance Ellipticity FWHM
30 41.97 48.08 61.06 0.10 +- 0.05 0.66 +- 0.11
60 46.44 42.70 56.41 0.09 +- 0.05 0.68 +- 0.10
80 51.78 44.33 57.10 0.14 +- 0.07 0.89 +- 0.24
Full Set Average 49.24 44.96 57.83    

Details

00:26 Going up at the beginning of the night to check the leaking problem and check IRTC.
  • Doug is not able to communicate with the camera.

01:30 Moving towards opening. IRTC is working now
  • they found a way to bypass the leaking problem. The small AGW is beeing cooled but not the pyramid...

01:44 Preseting to the first star for pointing correction and collimation.

Doug sent the email:
John, John and I inspected the leaky fittings and found
a couple of drops of glycol on one of the fittings/hose
and a couple drops on the AGw outer wall.  We wiped
everywhere we could and then put pig (absorbent cloth
around the wet fitting and on the outer wall of the AGw.
Both are jammed tight so they cannot move.  These
should absorb any more drops that the might come
out of the hose insulation.

The IRTC did not communicate, but a power cycle of
the IRTC computer and IRTC power did the job.

We are ready to operation and David is opening the
Chamber doors.

Doug

01:50 Interesting looking acquisition image with a double central obscuration hole. After some manual focus by David we see some astigmatism (3:1 sausage) and some coma. 10 iterations of active optics and we are down to 0.6" fwhm on the guider.

02:00 Collimated

Measure Rotator Center on IRTC

02:09 Preset to ACT0297 (7mag in R) to determine the center of rotation of the IRTC. David set IE=-18, CA=-39 from -10, -50.

02:15 Preset in ACTIVE mode with GS=1. Starting wfsc 28. 3:1 sausage form astigmatism.

02:20 Every third WFSC image has two stars in each subap. If I watch the guider, the is a guide image that is about 1" off. Look at wfsciamge00034.fits

Will use 40 milisecond exposures at 15 herz, 900 frames to get 60 seconds of rotation

02:33 Preset in Active with GS=10. Collimate. Guiding off. Rotator at 100. Send to 360. irtc....00004.fits, irtc...023712.fits Only to rotator 240

02:41 Send rot to 0. 1500 images. cube00005 header024051

02:45 Preset with PA=-60 rot=80. Send rot to 360, 1200 images, cube00006, header024756

02:53 offset 30" to get background. cube000007, header025453

03:14 send from 4 to 360. cube00009, header031426

03:17 offset 30", background cube000010, header031701

Transform Data on Stone D

03:21 Preset to StoneD for collimation (GS=11, PA=0)

03:31 transform_collect,num=60,exp=0.2,/GCS
  • we changed the exposure time to 12sec (instead of 30sec) because otherwise they would be overexposed
  • the preset failed giving error because it could not find all the necessary DD values:
===> Error in irc_getparameter
% Compiled module: IRC_FIND_PARAM.
===> Active Optics loop is not running
  • we asked David to make all DD variables public so that the script can read them

03:33 repeat : transform_collect,num=60,exp=0.2,/GCS
  • this time the preset went through
  • dimm seeing 0.9'' - gcs 0.6''
  • some wfs images look vignetted... alignment problem (?)

Transform Log
GStar wfsc # Single Image Cube Image
0 0 irtc.20120107.033454.fits irtc.20120107.00011_cube.fits
22 77 irtc.20120107.033539.fits irtc.20120107.00012_cube.fits
30 78-79 irtc.20120107.033707.fits irtc.20120107.00013_cube.fits
4 80-82 irtc.20120107.033912.fits irtc.20120107.00014_cube.fits
36 83-84 irtc.20120107.034155.fits irtc.20120107.00015_cube.fits
25 85-88 irtc.20120107.034401.fits irtc.20120107.00016_cube.fits
9 89-90 irtc.20120107.034755.fits irtc.20120107.00017_cube.fits
42 91-93 irtc.20120107.035001.fits irtc.20120107.00018_cube.fits
10 94-95 irtc.20120107.035244.fits irtc.20120107.00019_cube.fits
28 96 irtc.20120107.035450.fits irtc.20120107.00020_cube.fits
1 97-98 irtc.20120107.035617.fits irtc.20120107.00021_cube.fits
24 99-100 irtc.20120107.035841.fits irtc.20120107.00022_cube.fits
22 101-103 irtc.20120107.040046.fits irtc.20120107.00023_cube.fits
11 104-105 irtc.20120107.040331.fits irtc.20120107.00024_cube.fits
25 106-107 irtc.20120107.040536.fits irtc.20120107.00025_cube.fits
2 108-109 irtc.20120107.040742.fits irtc.20120107.00026_cube.fits
13 110-112 irtc.20120107.041040.fits irtc.20120107.00027_cube.fits
22 113-114 irtc.20120107.041325.fits irtc.20120107.00028_cube.fits
4 115-116 irtc.20120107.041531.fits irtc.20120107.00029_cube.fits
28 117-119 irtc.20120107.041736.fits irtc.20120107.00030_cube.fits
5 120-121 irtc.20120107.042019.fits irtc.20120107.00031_cube.fits
30 122-123 irtc.20120107.042241.fits irtc.20120107.00032_cube.fits
11 124-125 irtc.20120107.042447.fits irtc.20120107.00033_cube.fits
41 126-127 irtc.20120107.042653.fits irtc.20120107.00034_cube.fits
2 128-129 irtc.20120107.042901.fits irtc.20120107.00035_cube.fits
4 130-131 irtc.20120107.043140.fits irtc.20120107.00036_cube.fits
13 132-133 irtc.20120107.043346.fits irtc.20120107.00037_cube.fits
20 134-135 irtc.20120107.043553.fits irtc.20120107.00038_cube.fits

Measure Rotator Center on AGW

04:40 acquire mode with StoneD on -axis - actually it is too bright and we switch to a nearby BS star

04:43 collimate on BS9108

guiding off - active optics off

04:50 60 second guider image with rotator moving from 360 to 0, only get 2/3 of rotation. /OldRepository/AGW_Data/20120107/agw_center/left_guider000004.fits. Measure center at x=233, y = 227

04:56 90 second guider image with rotator moving from 0 to 360. /OldRepository/AGW_Data/20120107/agw_center/left_guider000005.fits. Measure center at x=232, y=225

Collimation and Dice5 Data

05:17 collimate_collect, bs9107,logname, retval, gs=23,/GCS -> col_70a
  • the script exited giving error:
% Compiled module: INSTRUMENT_START_ACQUISITION.
% Keyword IRTC not allowed in call to: INSTRUMENT_START_ACQUISITION
% Execution halted at: COLLIMATE_COLLECT  241
  /home/LBTO/idl/wfsc/collimate/collimate_collect.pro
%                      $MAIN$          
% Program caused arithmetic error: Floating illegal operand
  • Doug fixed it

05:23 collimate_collect, bs9107,logname, retval, gs=23,/GCS
  • we do not see a star on the IRTC - stop script
  • change the exposure time back to 30sec (total in the cube, 1.0secx30im)

05:30 collimate_collect, bs9107, logname, retval, gs=23,exp=1.0,/GCS -> col_70a

05:41 dice5_collect, dist=1, iter=5
  • script saved the first wfs image and exited without giving specific error
  • doug is running dice5 from the mountain
  • we lost 10min for script error
  • the star is at lower elevation now - we delete the 70a dir and create a 60a.

06:05 dice5_collect, dist=1, iter=5 -> dice5_1_60a
  • in one 1,1 offset the single image recorded was 'none' - to process this set I need to copy there the name of the single image of another 1,1 offset, because the only info it gets from this file is the offset values.

Ra/X Dec/Y Single Image Cube Image
Background Image
30 0 irtc.20120107.060523.fits irtc.20120107.00069_cube.fits
Dice5 1 arcsec RADEC
0.00000 0.00000 irtc.20120107.060618.fits irtc.20120107.00070_cube.fits
-1.00000 1.00000 irtc.20120107.060721.fits irtc.20120107.00071_cube.fits
1.00000 -1.00000 irtc.20120107.060832.fits irtc.20120107.00072_cube.fits
-1.00000 -1.00000 irtc.20120107.060939.fits irtc.20120107.00073_cube.fits
1.00000 1.00000 irtc.20120107.061052.fits irtc.20120107.00074_cube.fits
0.00000 0.00000 irtc.20120107.061202.fits irtc.20120107.00075_cube.fits
-1.00000 1.00000 irtc.20120107.061311.fits irtc.20120107.00076_cube.fits
1.00000 -1.00000 irtc.20120107.061424.fits irtc.20120107.00077_cube.fits
-1.00000 -1.00000 irtc.20120107.061534.fits irtc.20120107.00078_cube.fits
1.00000 1.00000 irtc.20120107.061647.fits irtc.20120107.00079_cube.fits
0.00000 0.00000 irtc.20120107.061758.fits irtc.20120107.00080_cube.fits
-1.00000 1.00000 irtc.20120107.061907.fits irtc.20120107.00081_cube.fits
1.00000 -1.00000 irtc.20120107.062020.fits irtc.20120107.00082_cube.fits
-1.00000 -1.00000 irtc.20120107.062130.fits irtc.20120107.00083_cube.fits
1.00000 1.00000 irtc.20120107.062243.fits irtc.20120107.00084_cube.fits
0.00000 0.00000 irtc.20120107.062354.fits irtc.20120107.00085_cube.fits
-1.00000 1.00000 irtc.20120107.062504.fits irtc.20120107.00086_cube.fits
1.00000 -1.00000 irtc.20120107.062614.fits irtc.20120107.00087_cube.fits
-1.00000 -1.00000 irtc.20120107.062725.fits irtc.20120107.00088_cube.fits
1.00000 1.00000 none (irtc.20120107.062243.fits) irtc.20120107.00089_cube.fits
0.00000 0.00000 irtc.20120107.062947.fits irtc.20120107.00090_cube.fits
-1.00000 1.00000 irtc.20120107.063101.fits irtc.20120107.00091_cube.fits
1.00000 -1.00000 irtc.20120107.063210.fits irtc.20120107.00092_cube.fits
-1.00000 -1.00000 irtc.20120107.063320.fits irtc.20120107.00093_cube.fits
1.00000 1.00000 irtc.20120107.063429.fits irtc.20120107.00094_cube.fits

06:36 dice5_collect, dist=10, iter=5 -> dice5_10_60a
  • finished at elevation 49

Ra/X Dec/Y Single Image Cube Image
Background Image
30 0 irtc.20120107.063706.fits irtc.20120107.00095_cube.fits
Dice5 10 arcsec RADEC
0.00000 0.00000 irtc.20120107.063802.fits irtc.20120107.00096_cube.fits
-10.0000 10.0000 irtc.20120107.063903.fits irtc.20120107.00097_cube.fits
10.0000 -10.0000 irtc.20120107.064013.fits irtc.20120107.00098_cube.fits
-10.0000 -10.0000 irtc.20120107.064123.fits irtc.20120107.00099_cube.fits
10.0000 10.0000 irtc.20120107.064236.fits irtc.20120107.00100_cube.fits
0.00000 0.00000 irtc.20120107.064352.fits irtc.20120107.00101_cube.fits
-10.0000 10.0000 irtc.20120107.064500.fits irtc.20120107.00102_cube.fits
10.0000 -10.0000 irtc.20120107.064610.fits irtc.20120107.00103_cube.fits
-10.0000 -10.0000 irtc.20120107.064723.fits irtc.20120107.00104_cube.fits
10.0000 10.0000 irtc.20120107.064833.fits irtc.20120107.00105_cube.fits
0.00000 0.00000 irtc.20120107.064948.fits irtc.20120107.00106_cube.fits
-10.0000 10.0000 irtc.20120107.065059.fits irtc.20120107.00107_cube.fits
10.0000 -10.0000 irtc.20120107.065207.fits irtc.20120107.00108_cube.fits
-10.0000 -10.0000 irtc.20120107.065317.fits irtc.20120107.00109_cube.fits
10.0000 10.0000 irtc.20120107.065428.fits irtc.20120107.00110_cube.fits
0.00000 0.00000 irtc.20120107.065542.fits irtc.20120107.00111_cube.fits
-10.0000 10.0000 irtc.20120107.065652.fits irtc.20120107.00112_cube.fits
10.0000 -10.0000 irtc.20120107.065803.fits irtc.20120107.00113_cube.fits
-10.0000 -10.0000 irtc.20120107.065916.fits irtc.20120107.00114_cube.fits
10.0000 10.0000 irtc.20120107.070027.fits irtc.20120107.00115_cube.fits
0.00000 0.00000 irtc.20120107.070138.fits irtc.20120107.00116_cube.fits
-10.0000 10.0000 irtc.20120107.070250.fits irtc.20120107.00117_cube.fits
10.0000 -10.0000 irtc.20120107.070357.fits irtc.20120107.00118_cube.fits
-10.0000 -10.0000 irtc.20120107.070512.fits irtc.20120107.00119_cube.fits
10.0000 10.0000 irtc.20120107.070624.fits irtc.20120107.00120_cube.fits

07:08 collimate_collect, bs9143, logname, retval, gs=5, PA=180,exp=1.0,/GCS -> col_30a

07:21 dice5_collect, dist=1, iter=5 -> dice5_1_30a
  • dimm seeing 1.1''

Ra/X Dec/Y Single Image Cube Image
Background Image
30 0 irtc.20120107.072158.fits irtc.20120107.00132_cube.fits
Dice5 1 arcsec RADEC
0.00000 0.00000 irtc.20120107.072253.fits irtc.20120107.00133_cube.fits
-1.00000 1.00000 irtc.20120107.072354.fits irtc.20120107.00134_cube.fits
1.00000 -1.00000 irtc.20120107.072503.fits irtc.20120107.00135_cube.fits
-1.00000 -1.00000 irtc.20120107.072616.fits irtc.20120107.00136_cube.fits
1.00000 1.00000 irtc.20120107.072726.fits irtc.20120107.00137_cube.fits
0.00000 0.00000 irtc.20120107.072840.fits irtc.20120107.00138_cube.fits
-1.00000 1.00000 irtc.20120107.072951.fits irtc.20120107.00139_cube.fits
1.00000 -1.00000 irtc.20120107.073100.fits irtc.20120107.00140_cube.fits
-1.00000 -1.00000 irtc.20120107.073211.fits irtc.20120107.00141_cube.fits
1.00000 1.00000 irtc.20120107.073322.fits irtc.20120107.00142_cube.fits
0.00000 0.00000 irtc.20120107.073510.fits irtc.20120107.00143_cube.fits
-1.00000 1.00000 irtc.20120107.073623.fits irtc.20120107.00144_cube.fits
1.00000 -1.00000 irtc.20120107.073733.fits irtc.20120107.00145_cube.fits
-1.00000 -1.00000 irtc.20120107.073845.fits irtc.20120107.00146_cube.fits
1.00000 1.00000 irtc.20120107.073955.fits irtc.20120107.00147_cube.fits
0.00000 0.00000 irtc.20120107.074108.fits irtc.20120107.00148_cube.fits
-1.00000 1.00000 irtc.20120107.074219.fits irtc.20120107.00149_cube.fits
1.00000 -1.00000 irtc.20120107.074328.fits irtc.20120107.00150_cube.fits
-1.00000 -1.00000 irtc.20120107.074442.fits irtc.20120107.00151_cube.fits
1.00000 1.00000 irtc.20120107.074550.fits irtc.20120107.00152_cube.fits
0.00000 0.00000 irtc.20120107.074700.fits irtc.20120107.00153_cube.fits
-1.00000 1.00000 irtc.20120107.074816.fits irtc.20120107.00154_cube.fits
1.00000 -1.00000 irtc.20120107.074923.fits irtc.20120107.00155_cube.fits
-1.00000 -1.00000 irtc.20120107.075037.fits irtc.20120107.00156_cube.fits
1.00000 1.00000 irtc.20120107.075149.fits irtc.20120107.00157_cube.fits

07:53 dice5_collect, dist=10, iter=5 -> dice5_10_30a
  • finished at elev 45

Ra/X Dec/Y Single Image Cube Image
Background Image
30 0 irtc.20120107.075319.fits irtc.20120107.00158_cube.fits
Dice5 10 arcsec RADEC
0.00000 0.00000 irtc.20120107.075414.fits irtc.20120107.00159_cube.fits
-10.0000 10.0000 irtc.20120107.075552.fits irtc.20120107.00160_cube.fits
10.0000 -10.0000 irtc.20120107.075704.fits irtc.20120107.00161_cube.fits
-10.0000 -10.0000 irtc.20120107.075817.fits irtc.20120107.00162_cube.fits
10.0000 10.0000 irtc.20120107.075927.fits irtc.20120107.00163_cube.fits
0.00000 0.00000 irtc.20120107.080035.fits irtc.20120107.00164_cube.fits
-10.0000 10.0000 irtc.20120107.080148.fits irtc.20120107.00165_cube.fits
10.0000 -10.0000 irtc.20120107.080258.fits irtc.20120107.00166_cube.fits
-10.0000 -10.0000 irtc.20120107.080415.fits irtc.20120107.00167_cube.fits
10.0000 10.0000 irtc.20120107.080523.fits irtc.20120107.00168_cube.fits
0.00000 0.00000 irtc.20120107.080633.fits irtc.20120107.00169_cube.fits
-10.0000 10.0000 irtc.20120107.080744.fits irtc.20120107.00170_cube.fits
10.0000 -10.0000 irtc.20120107.080856.fits irtc.20120107.00171_cube.fits
-10.0000 -10.0000 irtc.20120107.081007.fits irtc.20120107.00172_cube.fits
10.0000 10.0000 irtc.20120107.081118.fits irtc.20120107.00173_cube.fits
0.00000 0.00000 irtc.20120107.081231.fits irtc.20120107.00174_cube.fits
-10.0000 10.0000 irtc.20120107.081342.fits irtc.20120107.00175_cube.fits
10.0000 -10.0000 irtc.20120107.081454.fits irtc.20120107.00176_cube.fits
-10.0000 -10.0000 irtc.20120107.081642.fits irtc.20120107.00177_cube.fits
10.0000 10.0000 irtc.20120107.081753.fits irtc.20120107.00178_cube.fits
0.00000 0.00000 irtc.20120107.081905.fits irtc.20120107.00179_cube.fits
-10.0000 10.0000 irtc.20120107.082018.fits irtc.20120107.00180_cube.fits
10.0000 -10.0000 irtc.20120107.082129.fits irtc.20120107.00181_cube.fits
-10.0000 -10.0000 irtc.20120107.082239.fits irtc.20120107.00182_cube.fits
10.0000 10.0000 irtc.20120107.082350.fits irtc.20120107.00183_cube.fits

08:29 checking the winds

08:31 collimate_collect, Stone_F, logname, retval, gs=8, PA=0,exp=1.0,/GCS -> col_60a
  • it might be overexposed - repeat

08:43 collimate_collect, Stone_F, logname, retval, gs=8, PA=0,exp=0.5,num=60,/GCS -> col_60a
  • aborted because IRTC was in continuous mode
   Acquiring Single IRTC image for information...
===>Error in irc_setirparams
       err = Resmsg[0]  = IRTC2 SetIRParams command result: ERROR
       err = Resmsg[1]  = [Error] IRSocket::SetIRParams -> IR System busy. Command has been understood, but NOT executed.
===>Error in irc_setirparams
       err = Resmsg[0]  = IRTC2 SetIRParams command result: ERROR
       err = Resmsg[1]  = [Error] IRSocket::SetIRParams -> IR System busy. Command has been understood, but NOT executed.
% Program caused arithmetic error: Floating illegal operand

08:47 collimate_collect, Stone_F, logname, retval, gs=8, PA=0,exp=0.5,num=60,/GCS -> col_60a
  • repeat - this set should be fine

08:56 collimate_collect, Stone_G, logname, retval, gs=10, PA=0,exp=0.5,num=60,/GCS -> col_50a

09:11 transform_collect, num=60, exp=0.2,/GCS -> transform_G
  • there is some background from the moon on the wfs

Transform Log for Stone_G
GStar wfsc # Single Image Cube Image
0 0 irtc.20120107.091511.fits irtc.20120107.00217_cube.fits
2 384 irtc.20120107.091604.fits irtc.20120107.00218_cube.fits
10 385-386 irtc.20120107.091733.fits irtc.20120107.00219_cube.fits
11 387-388 irtc.20120107.091941.fits irtc.20120107.00220_cube.fits
16 389-390 irtc.20120107.092146.fits irtc.20120107.00221_cube.fits
2 391-392 irtc.20120107.092354.fits irtc.20120107.00222_cube.fits
10 393-394 irtc.20120107.092600.fits irtc.20120107.00223_cube.fits
11 395-396 irtc.20120107.092808.fits irtc.20120107.00224_cube.fits
16 397-398 irtc.20120107.093017.fits irtc.20120107.00225_cube.fits
5 399-401 irtc.20120107.093243.fits irtc.20120107.00226_cube.fits
6 402 irtc.20120107.093529.fits irtc.20120107.00227_cube.fits
8 403-404 irtc.20120107.093659.fits irtc.20120107.00228_cube.fits
14 405-407 irtc.20120107.093906.fits irtc.20120107.00229_cube.fits
10 408-409 irtc.20120107.094154.fits irtc.20120107.00230_cube.fits
5 410-412 irtc.20120107.094403.fits irtc.20120107.00231_cube.fits
15 413-415 irtc.20120107.094651.fits irtc.20120107.00232_cube.fits
14 416-418 irtc.20120107.094938.fits irtc.20120107.00233_cube.fits

09:54 collimate_collect, BS9142, logname, retval, gs=9, PA=0,exp=1.0,num=30,/GCS -> col_80a
  • seeing on guider oscillates between 1.3''-2.0''
  • dimm seeing 1.3''-1.5''

10:10 dice5_collect, dist=1, iter=5 -> dice5_1_80a
  • finished at elev80

Ra/X Dec/Y Single Image Cube Image
Background Image
30 0 irtc.20120107.101055.fits irtc.20120107.00245_cube.fits
Dice5 1 arcsec RADEC
0.00000 0.00000 irtc.20120107.101151.fits irtc.20120107.00246_cube.fits
-1.00000 1.00000 irtc.20120107.101253.fits irtc.20120107.00247_cube.fits
1.00000 -1.00000 irtc.20120107.101442.fits irtc.20120107.00248_cube.fits
-1.00000 -1.00000 irtc.20120107.101552.fits irtc.20120107.00249_cube.fits
1.00000 1.00000 irtc.20120107.101703.fits irtc.20120107.00250_cube.fits
0.00000 0.00000 irtc.20120107.101813.fits irtc.20120107.00251_cube.fits
-1.00000 1.00000 irtc.20120107.101924.fits irtc.20120107.00252_cube.fits
1.00000 -1.00000 irtc.20120107.102036.fits irtc.20120107.00253_cube.fits
-1.00000 -1.00000 irtc.20120107.102146.fits irtc.20120107.00254_cube.fits
1.00000 1.00000 irtc.20120107.102258.fits irtc.20120107.00255_cube.fits
0.00000 0.00000 irtc.20120107.102451.fits irtc.20120107.00256_cube.fits
-1.00000 1.00000 irtc.20120107.102559.fits irtc.20120107.00257_cube.fits
1.00000 -1.00000 irtc.20120107.102711.fits irtc.20120107.00258_cube.fits
-1.00000 -1.00000 irtc.20120107.102940.fits irtc.20120107.00259_cube.fits
1.00000 1.00000 irtc.20120107.103137.fits irtc.20120107.00260_cube.fits
0.00000 0.00000 irtc.20120107.103239.fits irtc.20120107.00261_cube.fits
-1.00000 1.00000 irtc.20120107.103349.fits irtc.20120107.00262_cube.fits
1.00000 -1.00000 irtc.20120107.103500.fits irtc.20120107.00263_cube.fits
-1.00000 -1.00000 irtc.20120107.103729.fits irtc.20120107.00264_cube.fits
1.00000 1.00000 irtc.20120107.103843.fits irtc.20120107.00265_cube.fits
0.00000 0.00000 irtc.20120107.103956.fits irtc.20120107.00266_cube.fits
-1.00000 1.00000 irtc.20120107.104145.fits irtc.20120107.00267_cube.fits
1.00000 -1.00000 irtc.20120107.104257.fits irtc.20120107.00268_cube.fits
-1.00000 -1.00000 irtc.20120107.104406.fits irtc.20120107.00269_cube.fits
1.00000 1.00000 irtc.20120107.104517.fits irtc.20120107.00270_cube.fits

10:47 dice5_collect, dist=10, iter=5 -> dice5_10_80a
  • finished at elev76

Ra/X Dec/Y Single Image Cube Image
Background Image
30 0 irtc.20120107.104725.fits irtc.20120107.00271_cube.fits
Dice5 10 arcsec RADEC
0.00000 0.00000 irtc.20120107.104820.fits irtc.20120107.00272_cube.fits
-10.0000 10.0000 irtc.20120107.105000.fits irtc.20120107.00273_cube.fits
10.0000 -10.0000 irtc.20120107.105112.fits irtc.20120107.00274_cube.fits
-10.0000 -10.0000 irtc.20120107.105223.fits irtc.20120107.00275_cube.fits
10.0000 10.0000 irtc.20120107.105334.fits irtc.20120107.00276_cube.fits
0.00000 0.00000 irtc.20120107.105526.fits irtc.20120107.00277_cube.fits
-10.0000 10.0000 irtc.20120107.105636.fits irtc.20120107.00278_cube.fits
10.0000 -10.0000 irtc.20120107.105748.fits irtc.20120107.00279_cube.fits
-10.0000 -10.0000 irtc.20120107.105858.fits irtc.20120107.00280_cube.fits
10.0000 10.0000 irtc.20120107.110010.fits irtc.20120107.00281_cube.fits
0.00000 0.00000 irtc.20120107.110122.fits irtc.20120107.00282_cube.fits
-10.0000 10.0000 irtc.20120107.110233.fits irtc.20120107.00283_cube.fits
10.0000 -10.0000 irtc.20120107.110345.fits irtc.20120107.00284_cube.fits
-10.0000 -10.0000 irtc.20120107.110456.fits irtc.20120107.00285_cube.fits
10.0000 10.0000 irtc.20120107.110608.fits irtc.20120107.00286_cube.fits
0.00000 0.00000 irtc.20120107.110718.fits irtc.20120107.00287_cube.fits
-10.0000 10.0000 irtc.20120107.110835.fits irtc.20120107.00288_cube.fits
10.0000 -10.0000 irtc.20120107.110944.fits irtc.20120107.00289_cube.fits
-10.0000 -10.0000 irtc.20120107.111055.fits irtc.20120107.00290_cube.fits
10.0000 10.0000 irtc.20120107.111205.fits irtc.20120107.00291_cube.fits
0.00000 0.00000 irtc.20120107.111322.fits irtc.20120107.00292_cube.fits
-10.0000 10.0000 irtc.20120107.111430.fits irtc.20120107.00293_cube.fits
10.0000 -10.0000 irtc.20120107.111542.fits irtc.20120107.00294_cube.fits
-10.0000 -10.0000 irtc.20120107.111653.fits irtc.20120107.00295_cube.fits
10.0000 10.0000 irtc.20120107.111809.fits irtc.20120107.00296_cube.fits

New Transformation

11:24 Put new Transformation in oacontrol.conf. Called new file oacontrol.conf.20120107. Previous oacontrol.conf was from 20111211a. The new transform used Stone_G and is
rgpoff:  0.0800000 psigpoff:  4.2568680
Quad III
Transformation:
ax1 + by1 + kx = x2
  -1.00084872644712      -1.371966153049578E-002  0.199384608504798     
ax1 + by1 + ky = y2
  1.371966153049578E-002  -1.00084872644712        612.341725030299     
RMS(X)=  0.04572  RMS(Y)=  0.04632

        Scale factor:  1.0008    
Rotation Angle (rad):   3.1552973
Rotation Angle (deg): 180.7853635
  Mirrored transform: NO

Star no   x_targ     y_targ    x_comp   y_comp      X-res        Y-res
      1      114.889      564.372      114.877      564.367      0.01138      0.00520
      2        4.103      475.902        4.127      475.873     -0.02382      0.02984
      3      -76.585      453.207      -76.689      453.175      0.10387      0.03257
      4      -29.666      578.291      -29.661      578.279     -0.00496      0.01183
      5       47.316      497.275       47.377      497.332     -0.06118     -0.05678
      6      -93.529      513.026      -93.510      513.068     -0.01926     -0.04165
      7     -166.689      554.076     -166.706      554.163      0.01751     -0.08744
      8       20.023      536.148       19.997      536.169      0.02610     -0.02121
      9       88.808      563.446       88.741      563.409      0.06654      0.03786
     10      -78.306      475.014      -78.321      474.987      0.01469      0.02689
     11     -114.863      565.206     -114.808      565.142     -0.05532      0.06448
     12      -57.314      450.586      -57.278      450.530     -0.03587      0.05581
     13       41.765      459.622       41.805      459.680     -0.03969     -0.05741
M_X_GP:   1 M_Y_GP:   1 signphi:   1
This not very many points, but the rms error was half of the Stone_D transform with 22 points taken earlier in the night, with a bit better conditions

David stopped and restarted oacontrol and GCS

11:29 collimate_collect,Stone_I, logname, retval, gs=13, PA=0,exp=1.0,num=30,/GCS -> col_50b

11:39 transform_collect, num=30, exp=1.0,/GCS -> transform_I
  • this set is obtained after implementing the new transformation
  • when the seeing is good the star is saturated
  • interrupt the OB and change exposure time

11:51 transform_collect, num=60, exp=0.5,/GCS, START=4 -> transform_I
  • we don't repeat the gs already done...
  • it could no reach GS=13, PA=-135 and preset failed

12:17 transform_collect, num=60, exp=0.5,/GCS, START=20 -> transform_I
  • we changed it into GS=13, PA=-100
  • dimm seeing >1.0'' but it might not be very accurate, guider seeing 0.7''

The transform data gave us
rgpoff:  0.3200000 psigpoff:  0.3298680
Quad III
Transformation:
ax1 + by1 + kx = x2
  -1.00163135842754      -1.385412530328125E-002  0.415658811176338     
ax1 + by1 + ky = y2
  1.385412530328125E-002  -1.00163135842754        612.773033979609     
RMS(X)=  0.03760  RMS(Y)=  0.03934

        Scale factor:  1.0015    
Rotation Angle (rad):   3.1554208
Rotation Angle (deg): 180.7924402
  Mirrored transform: NO

Star no   x_targ     y_targ    x_comp   y_comp      X-res        Y-res
      1       11.225      478.131       11.247      478.172     -0.02234     -0.04031
      2      -33.693      500.751      -33.678      500.828     -0.01503     -0.07700
      3      -24.339      581.287      -24.257      581.362     -0.08224     -0.07468
      4      130.627      576.901      130.620      576.936      0.00710     -0.03476
      5       29.210      596.172       29.195      596.228      0.01570     -0.05526
      6       55.452      509.502       55.470      509.515     -0.01848     -0.01325
      7       -4.849      486.863       -4.830      486.821     -0.01961      0.04152
      8      -83.999      527.309      -83.972      527.322     -0.02765     -0.01233
      9      112.391      578.705      112.359      578.696      0.03254      0.00897
     10       85.738      520.033       85.767      520.011     -0.02879      0.02204
     11        1.161      492.690        1.167      492.686     -0.00576      0.00338
     12      -78.768      609.011      -78.720      608.948     -0.04793      0.06290
     13      100.534      536.298      100.575      536.261     -0.04095      0.03752
     14       85.861      528.446       85.846      528.404      0.01453      0.04221
     15      -52.872      554.166      -52.850      554.123     -0.02161      0.04352
     16      -68.253      559.465      -68.325      559.468      0.07255     -0.00302
     17      -66.166      478.627      -66.167      478.629      0.00069     -0.00209
     18       13.926      575.571       13.926      575.592     -0.00001     -0.02068
     19        4.236      533.616        4.215      533.637      0.02101     -0.02064
     20      -10.440      526.532      -10.508      526.474      0.06727      0.05795
     21       48.223      470.846       48.181      470.838      0.04193      0.00735
     22      -67.685      562.385      -67.742      562.358      0.05709      0.02666
M_X_GP:   1 M_Y_GP:   1 signphi:   1

Transform Log
GStar wfsc # Single Image Cube Image
0 0 irtc.20120107.114132.fits irtc.20120107.00308_cube.fits
14 524 irtc.20120107.114241.fits irtc.20120107.00309_cube.fits
16 525-527 irtc.20120107.114435.fits irtc.20120107.00310_cube.fits
13 528 irtc.20120107.114737.fits irtc.20120107.00311_cube.fits
GStar wfsc # Single Image Cube Image
14 533 irtc.20120107.115254.fits irtc.20120107.00313_cube.fits
13 534-536 irtc.20120107.115424.fits irtc.20120107.00314_cube.fits
3 537-538 irtc.20120107.115712.fits irtc.20120107.00315_cube.fits
10 539 irtc.20120107.115908.fits irtc.20120107.00316_cube.fits
5 540 irtc.20120107.120038.fits irtc.20120107.00317_cube.fits
14 541-542 irtc.20120107.120208.fits irtc.20120107.00318_cube.fits
3 544-545 irtc.20120107.120414.fits irtc.20120107.00319_cube.fits
10 546-547 irtc.20120107.120626.fits irtc.20120107.00320_cube.fits
13 548-549 irtc.20120107.120834.fits irtc.20120107.00321_cube.fits
11 550-551 irtc.20120107.121040.fits irtc.20120107.00322_cube.fits
10 552-553 irtc.20120107.121248.fits irtc.20120107.00323_cube.fits
13 554 irtc.20120107.121455.fits irtc.20120107.00324_cube.fits
11 555-556 irtc.20120107.121623.fits irtc.20120107.00325_cube.fits
4 557-558 irtc.20120107.121830.fits irtc.20120107.00326_cube.fits
16 559-560 irtc.20120107.122037.fits irtc.20120107.00327_cube.fits
6 561-562 irtc.20120107.122246.fits irtc.20120107.00328_cube.fits
GStar wfsc # Single Image Cube Image
13 565 irtc.20120107.123011.fits irtc.20120107.00330_cube.fits
11 566-567 irtc.20120107.123146.fits irtc.20120107.00331_cube.fits
4 568-569 irtc.20120107.123355.fits irtc.20120107.00332_cube.fits
6 570 irtc.20120107.123604.fits irtc.20120107.00333_cube.fits
8 571 irtc.20120107.123734.fits irtc.20120107.00334_cube.fits
16 572 irtc.20120107.123903.fits irtc.20120107.00335_cube.fits
4 573 irtc.20120107.124032.fits irtc.20120107.00336_cube.fits
6 574 irtc.20120107.124202.fits irtc.20120107.00337_cube.fits
8 575 irtc.20120107.124331.fits irtc.20120107.00338_cube.fits
16 576-577 irtc.20120107.124500.fits irtc.20120107.00339_cube.fits
7 578-579 irtc.20120107.124708.fits irtc.20120107.00340_cube.fits

12:50 collimate_collect,BS9153, logname, retval, gs=3, PA=180,exp=1.0,num=30,/GCS -> col_60b

13:02 dice5_collect, dist=1, iter=5 -> dice5_1_60b

Ra/X Dec/Y Single Image Cube Image
Background Image
30 0 irtc.20120107.130224.fits irtc.20120107.00352_cube.fits
Dice5 1 arcsec RADEC
0.00000 0.00000 irtc.20120107.130321.fits irtc.20120107.00353_cube.fits
-1.00000 1.00000 irtc.20120107.130420.fits irtc.20120107.00354_cube.fits
1.00000 -1.00000 irtc.20120107.130530.fits irtc.20120107.00355_cube.fits
-1.00000 -1.00000 irtc.20120107.130644.fits irtc.20120107.00356_cube.fits
1.00000 1.00000 irtc.20120107.130753.fits irtc.20120107.00357_cube.fits
0.00000 0.00000 irtc.20120107.130906.fits irtc.20120107.00358_cube.fits
-1.00000 1.00000 irtc.20120107.131016.fits irtc.20120107.00359_cube.fits
1.00000 -1.00000 irtc.20120107.131129.fits irtc.20120107.00360_cube.fits
-1.00000 -1.00000 irtc.20120107.131240.fits irtc.20120107.00361_cube.fits
1.00000 1.00000 irtc.20120107.131352.fits irtc.20120107.00362_cube.fits
0.00000 0.00000 irtc.20120107.131505.fits irtc.20120107.00363_cube.fits
-1.00000 1.00000 irtc.20120107.131616.fits irtc.20120107.00364_cube.fits
1.00000 -1.00000 irtc.20120107.131728.fits irtc.20120107.00365_cube.fits
-1.00000 -1.00000 irtc.20120107.131843.fits irtc.20120107.00366_cube.fits
1.00000 1.00000 irtc.20120107.131948.fits irtc.20120107.00367_cube.fits
0.00000 0.00000 irtc.20120107.132102.fits irtc.20120107.00368_cube.fits
-1.00000 1.00000 irtc.20120107.132211.fits irtc.20120107.00369_cube.fits
1.00000 -1.00000 irtc.20120107.132323.fits irtc.20120107.00370_cube.fits
-1.00000 -1.00000 irtc.20120107.132432.fits irtc.20120107.00371_cube.fits
1.00000 1.00000 irtc.20120107.132545.fits irtc.20120107.00372_cube.fits
0.00000 0.00000 irtc.20120107.132658.fits irtc.20120107.00373_cube.fits
-1.00000 1.00000 irtc.20120107.132808.fits irtc.20120107.00374_cube.fits
1.00000 -1.00000 irtc.20120107.132922.fits irtc.20120107.00375_cube.fits
-1.00000 -1.00000 irtc.20120107.133029.fits irtc.20120107.00376_cube.fits
1.00000 1.00000 irtc.20120107.133138.fits irtc.20120107.00377_cube.fits

13:33 dice5_collect, dist=10, iter=5 -> dice5_10_60b
  • 3 full iterations completed. The background got too bright during the 4th iteration and the preset was cancelled

Ra/X Dec/Y Single Image Cube Image
Background Image
30 0 irtc.20120107.133323.fits irtc.20120107.00378_cube.fits
Dice5 10 arcsec RADEC
0.00000 0.00000 irtc.20120107.133420.fits irtc.20120107.00379_cube.fits
-10.0000 10.0000 irtc.20120107.133521.fits irtc.20120107.00380_cube.fits
10.0000 -10.0000 irtc.20120107.133630.fits irtc.20120107.00381_cube.fits
-10.0000 -10.0000 irtc.20120107.133744.fits irtc.20120107.00382_cube.fits
10.0000 10.0000 irtc.20120107.133852.fits irtc.20120107.00383_cube.fits
0.00000 0.00000 irtc.20120107.134005.fits irtc.20120107.00384_cube.fits
-10.0000 10.0000 irtc.20120107.134115.fits irtc.20120107.00385_cube.fits
10.0000 -10.0000 irtc.20120107.134224.fits irtc.20120107.00386_cube.fits
-10.0000 -10.0000 irtc.20120107.134335.fits irtc.20120107.00387_cube.fits
10.0000 10.0000 irtc.20120107.134445.fits irtc.20120107.00388_cube.fits
0.00000 0.00000 irtc.20120107.134600.fits irtc.20120107.00389_cube.fits
-10.0000 10.0000 irtc.20120107.134713.fits irtc.20120107.00390_cube.fits
10.0000 -10.0000 irtc.20120107.134823.fits irtc.20120107.00391_cube.fits
-10.0000 -10.0000 irtc.20120107.134938.fits irtc.20120107.00392_cube.fits
10.0000 10.0000 irtc.20120107.135048.fits irtc.20120107.00393_cube.fits
0.00000 0.00000 irtc.20120107.135157.fits irtc.20120107.00394_cube.fits
-10.0000 10.0000 irtc.20120107.135312.fits irtc.20120107.00395_cube.fits
10.0000 -10.0000 irtc.20120107.135426.fits irtc.20120107.00396_cube.fits
-10.0000 -10.0000 irtc.20120107.135534.fits irtc.20120107.00397_cube.fits

13:58 wfs camera saturated - END OF NIGHT

-- KonstantinaBoutsia - 07 Jan 2012