UT 20120104 LBC Technical Observations

Observer: ARakich (@LBT), DThompson (Tucson)
Telescope Operator: DGonzalez Huerta
Instrument Support: JMorris
Telescope Support:
SW support:

Summary

Checkout::
  • lbccontrol:/home 66MB free (94% full)
  • lbckill/start but did not reboot. Memory usage and load look good
  • CMU clock off by <2ms
  • Ran OneBias_Bino (twice), data got to archive and look OK
  • Check these. (can start up RB_Science script to view these as they are taken)

Twilight: heavy clouds but clearing. Delaying open. 02:44 Opened a few minutes ago, starting dofpia ayt 3h+60d
02:48 Co-pointing.
02:50 Turned on mirror ventilation
02:55 Running DOFPIA continuously for 20 minutes or so to see how much focus we are having to put in in "start of the night" conditions". Setting bluelimit=10, redlimit=10 so we don't converge.

DOFPIA local log files on obs2:
  • cd /scratch/20120104/
  • tail -f lbcia.log # to see the whole thing
  • tail -f lbcia.log | grep red # to see only the red data
  • tail -f lbcia.log | grep blue # to see only the blue data
  • more lbcia.log | grep red # to pull the full set of red data from the file
  • more lbcia.log | grep blue # to pull the full set of blue data from the file

[2012-01-04T03:05:01] MESG> --------------------------------------------------------------------------
[2012-01-04T03:05:01] MESG>           Computed Aberrations (nm)              |   (arcsec)   | channel 
[2012-01-04T03:05:01] MESG>  Defoc   AstX   AstY   ComaX  ComaY   Sph        |  Est.   Est. |         
[2012-01-04T03:05:01] MESG>  (Z4)    (Z5)   (Z6)   (Z7)   (Z8)   (Z11)  (Z22)| seeing  WIQ  |         
[2012-01-04T03:05:01] MESG> --------------------------------------------------------------------------
[2012-01-04T02:46:23] MESG>   2728   -393    174   -966   -199    474    100   1.99   1.21     red
[2012-01-04T02:48:09] MESG>     16   -266     35    157     26    363     65   1.61   0.26     red
[2012-01-04T02:56:46] MESG>   2622   -171     19    246    278    126     20   1.42   1.05     red
[2012-01-04T02:58:26] MESG>    284   -103      3     93     34     70     -5   1.28   0.15     red
[2012-01-04T03:00:02] MESG>    273     54    -93    -65     44     15     -5   1.37   0.14     red
[2012-01-04T03:01:36] MESG>    390    151     11    106     59      0     -5   1.38   0.19     red
[2012-01-04T03:03:10] MESG>    537     49    -65     28     17   -100    -20   1.27   0.24     red
[2012-01-04T03:04:44] MESG>    360     74    -75     11     -9     -8     -4   1.29   0.17     red
[2012-01-04T03:06:24] MESG>   -118     68    -10     18     26     50     -2   1.29   0.10     red
[2012-01-04T03:07:56] MESG>    696     32    -51     28     73    -84     -7   1.32   0.29     red
[2012-01-04T03:09:34] MESG>    128    -78    112     19     41    -31      9   1.27   0.11     red
[2012-01-04T03:11:11] MESG>   -170    108    -25     71    -35     44     -6   1.30   0.12     red
[2012-01-04T03:12:43] MESG>    215    -82    -67    104     36    -22    -14   1.27   0.13     red
[2012-01-04T03:14:16] MESG>    286     50    -40   -130     24   -141    -35   1.08   0.18     red
[2012-01-04T03:15:55] MESG>   -229     31    -61     44     36     62    -22   1.08   0.13     red
[2012-01-04T03:17:31] MESG>    414     69    -35    -32    -26    -39    -11   1.11   0.19     red
[2012-01-04T03:19:04] MESG>   -150    -66     -3     88     99     44    -18   0.89   0.12     red
[2012-01-04T03:20:41] MESG>    -38     79     29     80     31     25    -18   0.99   0.09     red
[2012-01-04T03:22:13] MESG>    435     92     32    -13     51    -85    -21   1.01   0.20     red
[2012-01-04T03:23:48] MESG>     57    -81     -9     31   -130   -155    -23   0.86   0.14     red
[2012-01-04T03:25:23] MESG>    113     62    -37   -215    -93    -43      9   0.93   0.14     red
[2012-01-04T03:26:57] MESG>     71      7    -71    122    110   -118    -14   0.92   0.14     red
[2012-01-04T03:28:29] MESG>    -29     66    100     31    -32     48      3   0.95   0.09     red
[2012-01-04T03:30:01] MESG>   -389    -26    -72    109    100     97     -8   0.91   0.20     red
[2012-01-04T03:31:37] MESG>    145     82     86    -80    -73    -58     -6   0.94   0.12     red
[2012-01-04T03:33:10] MESG>   -751    105     50    191     96    147    -12   0.85   0.34     red
[2012-01-04T03:34:45] MESG>    200    -17    -94    -47     30    -57    -21   0.79   0.12     red
[2012-01-04T03:36:18] MESG>     11     64    -55      8    -59    -26     -9   0.87   0.09     red
[2012-01-04T03:37:57] MESG>     18     28    -70    -14     42    -66    -21   0.78   0.09     red
[2012-01-04T03:39:33] MESG>   -157     43    153     -1     53     59     -2   0.87   0.12     red
[2012-01-04T03:41:10] MESG>   -294    -26    -70     86    -46      1    -10   0.86   0.15     red

[2012-01-04T03:46:06] MESG>    834     73     70    149    536    -69    -22   0.86   0.42     red
[2012-01-04T03:47:46] MESG>   -495     52     39     12     56     16     -5   0.89   0.21     red
[2012-01-04T03:49:24] MESG>     25      1    -67    -39     68    -82     -9   0.80   0.10     red
[2012-01-04T03:50:59] MESG>    580     46    -39     -8    -90   -151    -16   0.82   0.26     red
[2012-01-04T03:52:33] MESG>    -86     26     74     30     47     11     -2   0.91   0.09     red
[2012-01-04T03:54:08] MESG>   -827     54     46     73    -36     14     -2   0.84   0.34     red
[2012-01-04T03:55:44] MESG>    319    -64    -23     13    -60    -67     -5   0.78   0.16     red
[2012-01-04T03:57:16] MESG>    345     56     84     14     46    -26     -7   0.79   0.16     red
[2012-01-04T03:58:55] MESG>   -185     46     87     29     -7     11     -9   0.76   0.11     red
[2012-01-04T04:00:27] MESG>   -334     29    -57   -113     97      1     -4   0.75   0.17     red
[2012-01-04T04:02:01] MESG>    -80     -4    -42     48    -41      3     -7   0.73   0.09     red
[2012-01-04T04:03:36] MESG>    461      4    -66     23     44     17     -6   0.72   0.20     red
[2012-01-04T04:05:12] MESG>    677     56     99    -72   -100    -39     -6   0.77   0.29     red
[2012-01-04T04:06:47] MESG>   -296     43    -69    224    -26     12     -9   0.70   0.18     red
[2012-01-04T04:08:20] MESG>    486    -34    -46   -122    -14    -44     -3   0.73   0.22     red
[2012-01-04T04:09:58] MESG>   -212     32     88      9    -29    -54     -5   0.71   0.12     red
[2012-01-04T04:11:31] MESG>   -378     53     28     94     78     61     -4   0.73   0.18     red
[2012-01-04T04:13:12] MESG>    622     58    -23     30    -33    -54     -7   0.69   0.26     red
[2012-01-04T04:14:49] MESG>    176    -64     -6    -76     54    -13     -3   0.69   0.11     red
[2012-01-04T04:16:27] MESG>    132     19    -34    153    -44     36     16   0.93   0.12     red
[2012-01-04T04:18:03] MESG>    413    -33    -23    -73    -30     16     15   0.97   0.18     red
[2012-01-04T04:19:39] MESG>    178     36     26     33    -37    -25      2   0.84   0.11     red
[2012-01-04T04:21:10] MESG>    576     -6     87    -13     64     12     10   0.90   0.24     red
[2012-01-04T04:22:47] MESG>     20     31    -21     63     14     51      7   0.91   0.09     red
[2012-01-04T04:24:21] MESG>   -795     23    -27     -2     26    -26     -6   0.77   0.32     red
[2012-01-04T04:25:59] MESG>    440     27     56   -154    -10    -29     14   0.96   0.20     red
[2012-01-04T04:27:36] MESG>   -419     18    -47     77    -95     10     -6   0.80   0.19     red
[2012-01-04T04:29:10] MESG>   -156    -22    -56     88    -45    -27    -14   0.69   0.11     red
[2012-01-04T04:30:43] MESG>    523     39    -40   -105     28     40      7   0.89   0.23     red
[2012-01-04T04:32:19] MESG>   -161     -3     68     24     54     38     23   1.04   0.11     red
[2012-01-04T04:33:52] MESG>   -364     32     72    -11    -54     51     38   1.25   0.17     red


[2012-01-04T02:46:45] MESG>  -2373   -239   -484   -445   -508    582     74   1.96   1.06    blue
[2012-01-04T02:48:26] MESG>    313   -212   -314     92    -73    277     40   1.94   0.26    blue
[2012-01-04T02:57:05] MESG>   1895   -161   -250    -90   -172     53     11   1.96   0.76    blue
[2012-01-04T02:58:42] MESG>    266     59   -203     91     42     21    -11   1.79   0.15    blue
[2012-01-04T03:00:16] MESG>    305   -121   -121     88    -81    -37      2   1.57   0.16    blue
[2012-01-04T03:01:50] MESG>    105    129     32    -21     66     62      4   1.48   0.11    blue
[2012-01-04T03:03:24] MESG>    217     69    -61     83    -38      8      8   1.45   0.13    blue
[2012-01-04T03:05:01] MESG>    445   -168     24    -51    100     -6    -19   1.42   0.21    blue
[2012-01-04T03:06:37] MESG>     16   -114    -14     89    -43     -2      2   1.49   0.10    blue
[2012-01-04T03:08:11] MESG>    225   -113     44    -77      2     28      5   1.44   0.13    blue
[2012-01-04T03:09:46] MESG>    259    -19   -144    -15   -124    -68      8   1.44   0.15    blue
[2012-01-04T03:11:24] MESG>     18    -24   -144     99    103     25     -3   1.40   0.11    blue
[2012-01-04T03:12:56] MESG>    160    167    136   -121     61    -42    -14   1.41   0.14    blue
[2012-01-04T03:14:33] MESG>    381    -90    -63     32   -182   -203    -30   1.24   0.23    blue
[2012-01-04T03:16:08] MESG>   -132    175     88     64    169    107    -23   1.35   0.15    blue
[2012-01-04T03:17:45] MESG>    554    -80    -13     44      9    -21    -35   1.33   0.23    blue
[2012-01-04T03:19:20] MESG>    121    124     39     78    -47   -107    -26   1.45   0.13    blue
[2012-01-04T03:20:54] MESG>    224    115    146    -50     43    -12     -8   1.47   0.13    blue
[2012-01-04T03:22:29] MESG>   -204   -109     14     35      8     95      4   1.42   0.13    blue
[2012-01-04T03:24:03] MESG>    331    -99      7     50   -105    -89    -24   1.31   0.17    blue
[2012-01-04T03:25:39] MESG>    -52    127   -108    -79    -19      9      0   1.35   0.10    blue
[2012-01-04T03:27:10] MESG>    -34    -91     31      7     65     19     -8   1.23   0.09    blue
[2012-01-04T03:28:42] MESG>   -178   -105    -42    133    -78      5     12   1.40   0.13    blue
[2012-01-04T03:30:19] MESG>    332    274     18    -15     70    -53    -24   1.38   0.18    blue
[2012-01-04T03:31:51] MESG>   -224   -152     66    -70    148    102     15   1.23   0.16    blue
[2012-01-04T03:33:25] MESG>    271   -165     -1     47     -1   -103    -32   1.15   0.16    blue
[2012-01-04T03:34:58] MESG>    100    131    111    141     10     50    -19   1.20   0.12    blue
[2012-01-04T03:36:34] MESG>   -102    114     24     77    -88    -24    -25   1.27   0.11    blue
[2012-01-04T03:38:12] MESG>     89     52   -101   -116    -37     -6    -16   1.16   0.11    blue
[2012-01-04T03:39:50] MESG>    160   -130     -9      0    -45    -32     -8   1.21   0.11    blue
[2012-01-04T03:41:27] MESG>    236    149     65     63     36    -41     -6   1.29   0.14    blue

[2012-01-04T03:46:20] MESG>  -4390   -160     60    287   -617   -115     17   0.94   1.76    blue
[2012-01-04T03:47:60] MESG>   -598    137     63    -21   -130    -35     -5   1.11   0.26    blue
[2012-01-04T03:49:38] MESG>   -194     97   -120    -56     64    -20    -21   1.06   0.13    blue
[2012-01-04T03:51:12] MESG>   -200    114    112    -79    -33     50     -4   1.20   0.13    blue
[2012-01-04T03:52:48] MESG>    -98   -164     63    -49     28     99     -5   1.14   0.12    blue
[2012-01-04T03:54:22] MESG>   -122    104    161    162    -42   -116    -24   1.11   0.15    blue
[2012-01-04T03:55:57] MESG>    498    -70    -61    -45    -14    -21    -18   1.09   0.21    blue
[2012-01-04T03:57:32] MESG>    -10   -161     38    100     -8    -68    -20   1.12   0.11    blue
[2012-01-04T03:59:07] MESG>     12     60    -85   -116     35     20      1   1.09   0.10    blue
[2012-01-04T04:00:41] MESG>   -366     90    120     63    -27     29     -2   0.99   0.17    blue
[2012-01-04T04:02:16] MESG>     80    101     31     16     21    -19    -10   1.12   0.09    blue
[2012-01-04T04:03:51] MESG>    145    -95    -74     46    -69    -76    -12   0.98   0.12    blue
[2012-01-04T04:05:25] MESG>    210    111     70   -123     11     17      3   1.10   0.13    blue
[2012-01-04T04:07:01] MESG>    275   -135    -22     74    -48    -73     -6   0.98   0.15    blue
[2012-01-04T04:08:37] MESG>    770     73     23     83     70    -28    -22   1.09   0.32    blue
[2012-01-04T04:10:12] MESG>   -298   -142    -39    -32    -64    -39     -8   1.00   0.15    blue
[2012-01-04T04:11:49] MESG>    -89     39    173     40    153     32     -2   1.07   0.12    blue
[2012-01-04T04:13:29] MESG>    106    125     55     29    -81     10     -7   1.02   0.11    blue
[2012-01-04T04:15:06] MESG>    126     82     16    -54      6    -35      0   1.10   0.10    blue
[2012-01-04T04:16:43] MESG>    202   -207    -10     57   -128     67     21   1.19   0.15    blue
[2012-01-04T04:18:16] MESG>    145    -51   -172    -47    165     39     15   1.25   0.14    blue
[2012-01-04T04:19:51] MESG>    379     32    106     50    -40    -84    -15   1.12   0.18    blue
[2012-01-04T04:21:26] MESG>    361    -37    -68    -79     69     22      0   1.11   0.17    blue
[2012-01-04T04:23:00] MESG>    609     14   -105    -51     -9     37      0   1.22   0.26    blue
[2012-01-04T04:24:36] MESG>   -947     21    156     86     -1     -8     -2   1.04   0.39    blue
[2012-01-04T04:26:14] MESG>     96   -106    -36     24    -98    -31     13   1.27   0.11    blue
[2012-01-04T04:27:50] MESG>    307      7   -101     93     63    -42    -14   1.08   0.16    blue
[2012-01-04T04:29:24] MESG>     -6    134     59    -84     66    -90    -17   1.02   0.12    blue
[2012-01-04T04:30:58] MESG>      8    138     -5      9   -104     44     28   1.24   0.10    blue
[2012-01-04T04:32:31] MESG>    -10   -185    -36     31     -9     33     25   1.28   0.10    blue
[2012-01-04T04:34:04] MESG>   -417    -98    -42    -38    -58     66     40   1.42   0.19    blue
[2012-01-04T03:05:01] MESG> --------------------------------------------------------------------------

03:42 Just realized that the wrong collimation models without the t2 terms were loaded. Now loading the correct collimation models and starting again. Luckily the mirrors are still > 1 degree C out of thermal equilibrium. First impressions are encouraging.

04:36 Got a good set of data with good first impressions of temp 2 focus correction term. Now taking LBC focal plane data in ~ 1" seeing.

Graceful exit from DOFPIA (always with /X2) with "S"
04:36 RB_rVexin4.ob
04:39 RB_rVinex4.ob
DOFPIA "S" to exit after cycle 6 because red not converging, possibly because dofpia is having trouble calculating the sky background in this crowded field.
Clear c00 and active optics on red only
04:55 DOFPIA (took 5 iterations)
05:04 RB_rVexin4.ob
05:06 RB_rVinex_pa180.ob
05:10 DOFPIA (took 1 iteration)
05:13 RB_rVexin4_pa180
05:17 RB_rVinex4.ob
05:21 DOFPIA (took 4 iterations)
05:28 RB_rVsuperfoc.ob
05:33 DOFPIA (took 4 iterations)
05:40 RB_rVsuperfoc180.ob

05:50 Done with LBC, switch to MODS

06:35 Correct pointing on ACT0286 and collimation on gs=3 (R2=13.29, alt: gs=10 (R2=10.85)

CORASTIG basic functionality tests
  • a) collimate. Exit preset when collimated (stop guiding and wfsing).
  • b) Drive in 10000 nm Z6 on M1 PSF gui.
  • c) Send track preset to same star, when tracking run corastig.
  • d) Repeat a-c for +5000 nm Z6, -5000 nm Z6, -10000 nm Z6.

-- DavidThompson - 04 Jan 2012