LBC/Gregorian Technical Collimation Updates - 17 October 2011 UT

Observer(s): D. Thompson,A. Rakich, K. Boutsia, also present: DiPaola, F.Pedichini, M.Centrone
Telescope Operator: D. Huerta (LBTO)
Telescope Support: J. Urban (LBTO)
Instrument Support: J. Morris (LBTO)

Summary

Details

01:26 We start with tests for LBC software.
  • Go to pointing star WT10_319 for rangebal and collimation
  • we cannot do rangebal because the some values are missing from the header
  • we call T. Sargent, we switch to BP11, we call P. Grenz
  • we swithed to BP13 because it was not a TCS problem - values are saved correctly in DD

02:37 Probably we had problems with the headers because LBC was not connected to the telescope
  • connect to the telescope
  • run rangebal - this time it went through correctly
  • while we were running dofpia - LBC crashed and restarted - LBC control gui was not responding and dopfpia stopped during the 5th iteration because it would not find the images in newdata
  • AdP. rebooted LBC

03:08 Clear active optics - repeat OB and dofpia * globas offset SXZREL=-0.8 and DXZREL=-0.3 manually

03:20 start test for PA.
  • point to different stars and obtain more images changing the PA
  • point to WT10_319 - starting PA=353, repeat OB with PA=176 and PA=65
  • point to WT10_276 - starting PA=62, repeat OB with PA=196 and PA=33
  • point to WT10_164 - starting PA=237, repeat OB with PA=143

03:58 Slew back to WT10_319
  • the Parralactic angle on PCS (80.50) is different than the parralactic angle in the image header (98.91)

04:30 Turn off LBC to update SW. - Turn on again

04:35 Slew to WT10_319 again to verify if SW update worked.
  • now we have PARANGLE = ROTANGLE + PA_PNT
  • The position angle in the images are significantly different (and varying) from the requested PA. ROTANGLE in the header and in the rotator trajectory seems to be off from the parallactic angle as reported on the PCS GUI.

04:47 Reverted to previous LBC SW, PA's on sky now close to requested.

04:38 Preset to WT10_308 (EL~84) for FPIA
  • start with Andrew tests
  • clear instrument offsets and active optics
  • dofpia
  • rangebal - record instrument offsets - active optics, elevation, T1 and T2

05:11 Preset to WT10_272 (EL~49)
  • clear instrument offsets and active optics and repeat procedure.

05:30 Preset to WT10_302 (EL~29)
  • clear instrument offsets and active optics and repeat procedure.

05:45 Preset to WT10_234(EL~19)
  • clear instrument offsets and active optics and repeat procedure.

05:54 Preset to WT10_246(EL~43)
  • clear instrument offsets and active optics and repeat procedure.

06:05 Preset to WT10_327(EL~63)
  • clear instrument offsets and active optics and repeat procedure.

06:18 Preset to ACT0340(EL~75)
  • clear instrument offsets and active optics and repeat procedure.

06:29 Preset to ACT0325(EL~87)
  • clear instrument offsets and active optics and repeat procedure.

06:39 Preset to WT10_293(EL~80)
  • clear instrument offsets and active optics and repeat procedure.

06:52 Preset to WT10_325(EL~82)
  • clear instrument offsets and active optics and repeat procedure.

07:15 Preset to WT10_329(EL~58)
  • clear instrument offsets and active optics and repeat procedure.

07:24 Preset to WT10_331(EL~37)
  • clear instrument offsets and active optics and repeat procedure.

LBC Blue UT20111017 UT05:05 GlobOff Z=-1.127
Instrument Offsets.............. Active Optics....................
In_X IN_Y IN_Z IN_RX IN_RY AO_X AO_Y AO_Z AO_RX AO_RY EL T1 T2
0.488 0.230 -0.020 4.941 -10.466 0.000 0.000 -0.021 -4.621 0.666 84.1 8.83 9.10
0.418 0.069 -0.020 1.489 -8.970 0.000 0.000 0.004 -5.253 1.880 49.1 8.71 8.94
0.377 0.110 -0.020 2.354 -8.079 0.000 0.000 0.012 -4.437 2.469 29.0 8.64 8.85
0.449 0.023 -0.020 0.484 -9.630 0.000 0.000 -0.015 -1.484 0.690 19.4 8.59 8.80
0.308 0.022 -0.020 0.465 -6.597 0.000 0.000 0.084 -1.621 -1.611 43.4 8.54 8.73
0.301 0.056 -0.020 1.212 -6.455 0.000 0.000 0.000 -4.863 -3.562 63.5 8.45 8.65
0.259 0.088 -0.020 1.892 -5.547 0.000 0.000 0.006 -6.240 -4.102 74.9 8.39 8.60
0.234 0.101 -0.020 2.159 -5.014 0.000 0.000 0.030 -4.361 -2.279 87.2 8.32 8.57
0.278 0.073 -0.020 1.564 -5.972 0.000 0.000 0.046 -4.019 -0.752 80.5 8.29 8.55
0.170 0.124 -0.020 2.660 -3.644 0.000 0.000 0.077 -5.997 -2.428 82.2 8.20 8.50
0.257 0.080 -0.020 1.710 -5.517 0.000 0.000 0.042 -4.159 -3.899 57.9 8.14 8.45
0.210 0.009 -0.020 0.184 -4.508 0.000 0.000 0.101 -0.45 -0.718 36.9 8.09 8.40

LBC Red UT20111017 UT5:05 GlobOff Z=-0.603
Instrument Offsets.............. Active Optics....................
In_X IN_Y IN_Z IN_RX IN_RY AO_X AO_Y AO_Z AO_RX AO_RY EL T1 T2
-0.415 0.025 0.069 0.540 8.906 0.000 0.000 0.007 -2.354 2.095 84.1 8.82 8.61
-0.318 0.226 0.069 4.857 6.831 0.000 0.000 -0.006 -6.156 5.717 49.1 8.70 8.46
-0.298 0.136 0.069 2.916 6.385 0.000 0.000 0.022 -4.474 5.614 29.0 8.64 8.40
-0.417 0.190 0.069 4.076 8.955 0.000 0.000 0.016 -3.880 5.336 19.4 8.59 8.37
-0.317 0.172 0.069 3.689 6.801 0.000 0.000 0.072 -2.850 1.665 43.4 8.54 8.34
-0.291 0.245 0.069 5.250 6.242 0.000 0.000 -0.036 -6.417 2.662 63.5 8.45 8.29
-0.234 0.244 0.069 5.229 5.027 0.000 0.000 -0.005 -7.463 3.703 74.9 8.39 8.22
-0.236 0.206 0.069 4.416 5.072 0.000 0.000 0.042 -6.187 -0.119 87.2 8.32 8.15
-0.186 0.202 0.069 4.328 3.987 0.000 0.000 -0.027 -4.929 5.394 80.5 8.29 8.11
-0.124 0.205 0.069 4.399 2.651 0.000 0.000 0.055 -7.016 3.527 82.2 8.20 8.00
-0.275 0.186 0.069 3.993 5.899 0.000 0.000 0.001 -4.492 1.494 57.9 8.14 7.94
-0.220 0.148 0.069 3.174 4.711 0.000 0.000 0.095 -1.746 1.524 36.9 8.09 7.89

Note for quicker recording of the data...
If a file (~LBTO/InstOff_ActOp.dat) contains the following:
psf.side[0].primaryMirror.collimation.localOffset[0]
psf.side[0].primaryMirror.collimation.localOffset[1]
psf.side[0].primaryMirror.collimation.localOffset[2]
psf.side[0].primaryMirror.collimation.localOffset[3]
psf.side[0].primaryMirror.collimation.localOffset[4]
psf.side[0].primaryMirror.collimation.activeOptics[0]
psf.side[0].primaryMirror.collimation.activeOptics[1]
psf.side[0].primaryMirror.collimation.activeOptics[2]
psf.side[0].primaryMirror.collimation.activeOptics[3]
psf.side[0].primaryMirror.collimation.activeOptics[4]
psf.side[0].primaryMirror.collimation.angle
psf.side[0].primaryMirror.collimation.temperature
psf.side[0].primaryMirror.collimation.temperature2
psf.side[1].primaryMirror.collimation.localOffset[0]
psf.side[1].primaryMirror.collimation.localOffset[1]
psf.side[1].primaryMirror.collimation.localOffset[2]
psf.side[1].primaryMirror.collimation.localOffset[3]
psf.side[1].primaryMirror.collimation.localOffset[4]
psf.side[1].primaryMirror.collimation.activeOptics[0]
psf.side[1].primaryMirror.collimation.activeOptics[1]
psf.side[1].primaryMirror.collimation.activeOptics[2]
psf.side[1].primaryMirror.collimation.activeOptics[3]
psf.side[1].primaryMirror.collimation.activeOptics[4]
psf.side[1].primaryMirror.collimation.angle
psf.side[1].primaryMirror.collimation.temperature
psf.side[1].primaryMirror.collimation.temperature2

and you invoke it on the command line with:
irc GetParameter InstOff_ActOp.dat

then you record the values Andrew needs quickly and without error. You can then reformat as needed. You can also re-direct the data to an output file if you like.

7:55 Switching to LFBG AGw to work on the new collimation model.

08:35 Preset to BS9107 to collimate on-axis

cp SXPMLUCIFERCollimation.dat SXPMLUCIFERCollimation.20111017.sav
cp SXSMLUCIFERCollimation.dat SXSMLUCIFERCollimation.20111017.sav
cp SXPMLUCIFERCollimation.20110908.dat SXPMLUCIFERCollimation.dat
cp SXSMLUCIFERCollimation.20110908.dat SXSMLUCIFERCollimation.dat
Found an extra carriage return at the end of the SXPM file.

Global offsets updated for new AOM2 starting from 20110908 models:
SXPMLUCIFERCollimation.20111017GO.dat and SXSMLUCIFERCollimation.20111017GO.dat
These have not been copied to the default files yet.

Make list of selected rangebal'ed wfs images (e.g. "wcs.lis")
hsel @wfs.lis "M1COLL0,M1COLL1,M1COLL2,M1COLL3,M1COLL4,M2COLL0,M2COLL1,M2COLL2,M2COLL3,M2COLL4,TELEL,T301,T201,AMBTEMP,GLASTEMP,$I" yes > "hdr.dat"

left_wfscimage000073 WT10_214 57
left_wfscimage000080 ACT0265 71
left_wfscimage000090 ACT0284 77
left_wfscimage000096 WT10_344 83
left_wfscimage000116 WT10_370 67
left_wfscimage000125 ACT0263 55
left_wfscimage000171 WT10_157 28
left_wfscimage000196 WT10_237 45
left_wfscimage000206 WT10_220 38
left_wfscimage000216 WT10_305 55
left_wfscimage000225 WT10_303 77
left_wfscimage000229 WT10_303 78

Seeing was marginal for a lot of this (~2") but had a lot of trouble collimating at lower elevations

In collimated WFS image the spots appear systematically offset from the center of the lenslet aaray. See, for example, wfscimage000225

-- KonstantinaBoutsia - 17 Oct 2011
Topic revision: r6 - 19 Oct 2011, KonstantinaBoutsia
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.