Observer(s):D. Miller, J. Hill, A. Rakich, K. Boutsia (Tucson)
Telescope Operator: G. Becchetti (LBTO)
Telescope Support: ?
Instrument Support:: ?
Summary
We lost 3 hours due to high winds
Elevation |
Preset |
Guiding/Collimation |
Dice5 (1x1) |
Dice5 (10x10) |
Large Offsets (1'-3') |
30 |
col_30a, col_30b |
col_30a, col_30b |
|
|
|
45 |
col_45a |
col_45a |
|
|
|
60 |
col_60a, col_60b |
col_60a, col_60b |
dice5_1_60a |
dice5_10_60a |
|
75 |
col_75a, col_75b, col_75c |
col_75a, col_75b, col_75c |
dice5_1_75a (bad trans.) dice5_1_75b, dice5_1_75c |
dice5_10_75a, dice5_10_75b |
|
Details
07:30 Flattening the mirror
07:42 Dome closed because of high wind
10:40 Open dome again - moving to zenith
10:45 preset - >iif_preset, M5_1416, GS=0, MODE=ACQUIRE, ROTMODE=PARALLACTIC
10:57 preset to do collimate_collect - > collimate_collect, BS9162, GS=2, PA=-90, SETS=20
- no star found
- we're trying to find the star with an iif_preset -> iif_preset, BS9162, GS=2, MODE=GUIDE
- there is a star but it is way out of focus... we sent iif_preset again but with MODE=ACQUIRE
- actually before we were seeing a ghost and GS was out of the acquisition image. G.B. did a pointing correction.
11:09 repeat iif_preset, BS9162, GS=2, MODE=GUIDE
- either bad focus or very bad seeing - almost 4 degrees of temp difference for the mirrors
11:10 collimate_collect, BS9162, GS=2, SETS=20
- actually needs to be done from GCS, so we add flag: /GCS
- script aborted - getirparams error
11:25 we're acquiring on axis to see if our pointing is correct -> iif_preset, BS9162, GS=0, MODE=ACQUIRE
- we see the star and we start the collimate collect again
- seeing 1.2''-1.4''
11:35 dice5_1_75c
- seeing 1.3 - 1.8'' - very variable seeing
Ra/X |
Dec/Y |
Single Image |
Cube Image |
Background Image |
30 |
0 |
irtc.20110324.113713.fits |
irtc.20110324.00208_cube.fits |
Dice5 1 arcsec RADEC |
0.00000 |
0.00000 |
irtc.20110324.113803.fits |
irtc.20110324.00209_cube.fits |
-1.00000 |
1.00000 |
irtc.20110324.113854.fits |
irtc.20110324.00210_cube.fits |
1.00000 |
-1.00000 |
irtc.20110324.113945.fits |
irtc.20110324.00211_cube.fits |
-1.00000 |
-1.00000 |
irtc.20110324.114039.fits |
irtc.20110324.00212_cube.fits |
1.00000 |
1.00000 |
irtc.20110324.114130.fits |
irtc.20110324.00213_cube.fits |
0.00000 |
0.00000 |
irtc.20110324.114221.fits |
irtc.20110324.00214_cube.fits |
-1.00000 |
1.00000 |
irtc.20110324.114317.fits |
irtc.20110324.00215_cube.fits |
1.00000 |
-1.00000 |
irtc.20110324.114423.fits |
irtc.20110324.00216_cube.fits |
-1.00000 |
-1.00000 |
irtc.20110324.114513.fits |
irtc.20110324.00217_cube.fits |
1.00000 |
1.00000 |
irtc.20110324.114605.fits |
irtc.20110324.00218_cube.fits |
0.00000 |
0.00000 |
irtc.20110324.114655.fits |
irtc.20110324.00219_cube.fits |
-1.00000 |
1.00000 |
irtc.20110324.114747.fits |
irtc.20110324.00220_cube.fits |
1.00000 |
-1.00000 |
irtc.20110324.114838.fits |
irtc.20110324.00221_cube.fits |
-1.00000 |
-1.00000 |
irtc.20110324.114947.fits |
irtc.20110324.00222_cube.fits |
1.00000 |
1.00000 |
irtc.20110324.115057.fits |
irtc.20110324.00223_cube.fits |
0.00000 |
0.00000 |
irtc.20110324.115148.fits |
irtc.20110324.00224_cube.fits |
-1.00000 |
1.00000 |
irtc.20110324.115240.fits |
irtc.20110324.00225_cube.fits |
1.00000 |
-1.00000 |
irtc.20110324.115336.fits |
irtc.20110324.00226_cube.fits |
-1.00000 |
-1.00000 |
irtc.20110324.115427.fits |
irtc.20110324.00227_cube.fits |
1.00000 |
1.00000 |
irtc.20110324.115518.fits |
irtc.20110324.00228_cube.fits |
0.00000 |
0.00000 |
irtc.20110324.115609.fits |
irtc.20110324.00229_cube.fits |
-1.00000 |
1.00000 |
irtc.20110324.115701.fits |
irtc.20110324.00230_cube.fits |
1.00000 |
-1.00000 |
irtc.20110324.115753.fits |
irtc.20110324.00231_cube.fits |
-1.00000 |
-1.00000 |
irtc.20110324.115843.fits |
irtc.20110324.00232_cube.fits |
1.00000 |
1.00000 |
irtc.20110324.115934.fits |
irtc.20110324.00233_cube.fits |
12:00 dice5_10_75b
Ra/X |
Dec/Y |
Single Image |
Cube Image |
Background Image |
30 |
0 |
irtc.20110324.120054.fits |
irtc.20110324.00234_cube.fits |
Dice5 10.0000 arcsec RADEC |
0.00000 |
0.00000 |
irtc.20110324.120142.fits |
irtc.20110324.00235_cube.fits |
-10.0000 |
10.0000 |
irtc.20110324.120233.fits |
irtc.20110324.00236_cube.fits |
10.0000 |
-10.0000 |
irtc.20110324.120324.fits |
irtc.20110324.00237_cube.fits |
-10.0000 |
-10.0000 |
irtc.20110324.120419.fits |
irtc.20110324.00238_cube.fits |
10.0000 |
10.0000 |
irtc.20110324.120607.fits |
irtc.20110324.00239_cube.fits |
0.00000 |
0.00000 |
irtc.20110324.120714.fits |
irtc.20110324.00240_cube.fits |
-10.0000 |
10.0000 |
irtc.20110324.120804.fits |
irtc.20110324.00241_cube.fits |
10.0000 |
-10.0000 |
irtc.20110324.120855.fits |
irtc.20110324.00242_cube.fits |
-10.0000 |
-10.0000 |
irtc.20110324.121043.fits |
irtc.20110324.00243_cube.fits |
10.0000 |
10.0000 |
irtc.20110324.121149.fits |
irtc.20110324.00244_cube.fits |
0.00000 |
0.00000 |
irtc.20110324.121239.fits |
irtc.20110324.00245_cube.fits |
-10.0000 |
10.0000 |
irtc.20110324.121332.fits |
irtc.20110324.00246_cube.fits |
10.0000 |
-10.0000 |
irtc.20110324.121500.fits |
irtc.20110324.00247_cube.fits |
-10.0000 |
-10.0000 |
irtc.20110324.121553.fits |
irtc.20110324.00248_cube.fits |
10.0000 |
10.0000 |
irtc.20110324.121645.fits |
irtc.20110324.00249_cube.fits |
0.00000 |
0.00000 |
irtc.20110324.121737.fits |
irtc.20110324.00250_cube.fits |
-10.0000 |
10.0000 |
irtc.20110324.121846.fits |
irtc.20110324.00251_cube.fits |
10.0000 |
-10.0000 |
irtc.20110324.121938.fits |
irtc.20110324.00252_cube.fits |
-10.0000 |
-10.0000 |
irtc.20110324.122045.fits |
irtc.20110324.00253_cube.fits |
10.0000 |
10.0000 |
irtc.20110324.122152.fits |
irtc.20110324.00254_cube.fits |
0.00000 |
0.00000 |
irtc.20110324.122320.fits |
irtc.20110324.00255_cube.fits |
-10.0000 |
10.0000 |
irtc.20110324.122507.fits |
irtc.20110324.00256_cube.fits |
10.0000 |
-10.0000 |
irtc.20110324.122558.fits |
irtc.20110324.00257_cube.fits |
-10.0000 |
-10.0000 |
irtc.20110324.122704.fits |
irtc.20110324.00258_cube.fits |
12:29 collimate_collect, BS9158, GS=4, PA=-90, SETS=10, /GCS
12:40 dice5_1_60b
- only some offsets done - getting too bright!!!
Ra/X |
Dec/Y |
Single Image |
Cube Image |
Background Image |
30 |
0 |
irtc.20110324.124105.fits |
irtc.20110324.00271_cube.fits |
Dice5 1.00000 arcsec RADEC |
0.00000 |
0.00000 |
irtc.20110324.124155.fits |
irtc.20110324.00272_cube.fits |
-1.00000 |
1.00000 |
irtc.20110324.124323.fits |
irtc.20110324.00273_cube.fits |
1.00000 |
-1.00000 |
irtc.20110324.124413.fits |
irtc.20110324.00274_cube.fits |
-1.00000 |
-1.00000 |
irtc.20110324.124503.fits |
irtc.20110324.00275_cube.fits |
1.00000 |
1.00000 |
irtc.20110324.124555.fits |
irtc.20110324.00276_cube.fits |
0.00000 |
0.00000 |
irtc.20110324.124646.fits |
irtc.20110324.00277_cube.fits |
-1.00000 |
1.00000 |
irtc.20110324.124737.fits |
irtc.20110324.00278_cube.fits |
1.00000 |
-1.00000 |
irtc.20110324.124828.fits |
irtc.20110324.00279_cube.fits |
-1.00000 |
-1.00000 |
irtc.20110324.124919.fits |
irtc.20110324.00280_cube.fits |
1.00000 |
1.00000 |
irtc.20110324.125016.fits |
irtc.20110324.00281_cube.fits |
0.00000 |
0.00000 |
irtc.20110324.125105.fits |
irtc.20110324.00282_cube.fits |
-1.00000 |
1.00000 |
irtc.20110324.125211.fits |
irtc.20110324.00283_cube.fits |
1.00000 |
-1.00000 |
irtc.20110324.125301.fits |
irtc.20110324.00284_cube.fits |
-1.00000 |
-1.00000 |
irtc.20110324.125352.fits |
irtc.20110324.00285_cube.fits |
12:57 - END OF NIGHT
--
KonstantinaBoutsia - 24 Mar 2011