AO Retroreflector Work: 23 October 2010 UT
Observer: DMiller, SEsposito, MXompero, LBusoni, APuglisi, FQuiros
Telescope Operator: DHuerta (LBTO)
Telescope Support: JUrban (LBTO)
Instrument Support: TShih (LBTO)
Summary
Snow and clouds at the beginning of the night. 105% humidity
Preparations
Details
Collimation Lookup Table for Retroreflector
03:40 Start at el=90. The first three (131, 214, 243) may not have had all the t/t offloaded from the AO secondary. Those after do! (Steps of 5 degrees)
03:46 Down to 72
03:49 Up to 90
03:54 Down to 50
04:01 Up to 90
04:11 Down to 26
04:14 Up to 50 (041141 taken too soon: remove)
04:17 Down to 26
04:23 Up to 70
04:25 Down to 50
04:30 Up to 90
04:34 Down to 26 (Steps of 10 degrees)
04:39 Up to 90 (043951 is last irtc image)
--
DougMiller - 23 Oct 2010