Commissioning: 5 July 2010 UT
Observer: Pascale H (LBTO) Doug M (Tucson)
Telescope Operator: Steve A (LBTO)
Telescope Support: (LBTO)
Instrument Support: Tim S (LBTO)
Adaptive Secondary Operator: Pascale H (LBTO), Marco X (Firenze)
Summary
Night was clear with an average seeing of ~0.8-0.9".
Dice5 data on 7 stars at elevation > 45deg.
Collimation data at low elevation ~30deg.
Transformation data on
StoneOagw field
We restarted twice the GCS due to problem of WFS. We do not know if the problem was script or GCS correlated.
Preparations
Single frame names refer to: irtc.20100705.xxxxxx.fits
Cube names refer to: irtc.20100705_00xxx_cube.fit
Plan for the night: follow Doug's verification plan, in particular to transformation data, collimation and pointing models.
Details
Open
02:19 Open T-air=10.7C, Humidity=53%, Wind=8m/s
02:30 The Shell is set.
Preset + Collimation
02:58 pointto ACT0256 Tel="ACQUIRE" gs=0 PA=0 PAM-
03:02 pointto ACT0343 Tel="ACQUIRE" gs=0 PA=0 PAM- Elevation 65deg
Steve is doing a ptreset + ptspiral_right
IE=-3 CA=11
03:14 pointto BS9162 Tel="ACTIVE" gs=0
Seeing~1-1.1"
03:30 pointto BS9131 Tel="ACTIVE" gs=0
03:33 pointto BS9131 Tel="ACQUIRE" gs=0 PA=0 PAM- Elevation 29deg
IE= -19 CA= 4
- wfscimage000024.fits - wfscimage000038.fits : we hit the limit so Steve has to backup the active optics corrections values.
- Strong Astigmatism : ~5arcsec
Steve is clearing the active optics corrections values.
03:53 pointto BS9139 Tel="ACTIVE" gs=8 Elevation 29deg
- wfscimage000042.fits - wfscimage000057.fits
- Strong Astigmatism : ~6arscec
04:05 pointto BS9162 Tel="ACTIVE" gs=0
- wfscimage000059.fits - wfscimage000075.fits
Steve cleared the active optics.
Seeing~0.9"
Dice5 data
04:27 pointto BS9166 Tel="ACTIVE" gs=15 PA=0 Elevation 83deg
04:32 offset 30 0
04:33 takeseq 2.0 30
04:34 offset 0 0
04:35 dice5 1x1 RADEC 2.0 30 3 :
- first : 043608 cube 49
- last : 045702 cube 63
04:58 pointto BS9177 Tel="ACTIVE" gs=45 Elevation 62deg
05:05 offset 30 0
05:06 takeseq 2.0 30
05:07 offset 0 0
05:08 dice5 3x3 RADEC 2.0 30 3 :
Interrupted.
05:15 pointto BS9177 Tel="ACTIVE" gs=45 PA=0 Elevation 62deg
05:15 dice5 3x3 RADEC 2.0 30 3 :
- first : 051548 cube 69
- last : 053702 cube 83
05:38 pointto BS9162 Tel="ACTIVE" gs=6 PA=0 Elevation 67deg
05:41 offset 30 0
05:41 takeseq 2.0 30
05:43 offset 0 0
05:43 dice5 2x2 RADEC 2.0 30 3 :
- first : 054405 cube 85
- last : 060514 cube 99
06:07 pointto BS9166 Tel="ACTIVE" gs=15 PA=0 Elevation 75deg
06:09 pointto BS9166 Tel="ACQUIRE" gs=0 PA=0 PAM-
06:15 pointto BS9166 Tel="ACTIVE" gs=15 PA=0
06:15 offset 30 0
06:16 takeseq 2.0 30
06:17 offset 0 0
06:18 dice5 5x5 RADEC 2.0 30 3 :
- first : 061842 cube 101
- last : 063943 cube 115
Collimation at low elevation
06:41 pointto BS9182 Tel="ACTIVE" gs=0 Elevation 38 deg
- wfscimage000281.fits - wfscimage000292.fits
06:53 pointto BS9182 Tel="ACTIVE" gs=0 PA=90
- wfscimage000293.fits - wfscimage000296.fits
06:56 pointto BS9182 Tel="ACTIVE" gs=0 PA=-90
- wfscimage000297.fits - wfscimage000308.fits
07:06 pointto BS9153 Tel="ACTIVE" gs=0 PA=0 Elevation 25deg
07:09 pointto BS9153 Tel="ACQUIRE" gs=0 PA=0 PAM-
07:11 Steve is doing a ptspiral_right
CA=-21 IE=-51
07:13 pointto BS9153 Tel="ACTIVE" gs=0 PA=0
- Astigmatism 4-5arcsec
- wfscimage000309.fits - wfscimage000313.fits
07:18 WFS has been stopped
Back to dice5 data
07:28 pointto BS9169 Tel="ACTIVE" gs=14 PA=0 Elevation 60deg
07:31 pointto BS9169 Tel="ACQUIRE" gs=0 PA=0 PAM-
IE=-33 CA=-1
07:33 pointto BS9169 Tel="ACTIVE" gs=14 PA=0
07:35 offset 30 0
07:36 takeseq 2.0 30
07:37 offset 0 0
07:38 dice5 5x5 RADEC 2.0 30 3 :
- first : 073831 cube 117
- last : 075935 cube 131
Collimation at low elevation
08:00 The parameter WFS_lenslet_edge_x has been changed at 364.7
08:01 pointto BS9186 Tel="ACTIVE" gs=0 Elevation 28deg
08:05 pointto BS9186 Tel="ACQUIRE" gs=0 PA=0 PAM-
Steve has done a ptspiral_right
08:07 pointto BS9186 Tel="ACTIVE" gs=0 Elevation 28deg
- wfscimage000347.fits - wfscimage000358.fits
08:16 cd /OldRepository/IRTC_Data/20100627/transform
08:16 prepdir
08:17 pointto
StoneOagw Tel="ACTIVE" gs=0
Seeing~0.8"
08:23 pointto
StoneOagw Tel="ACTIVE" gs=2 PA=0
08:24 takepic 2.0
08:29 pointto
StoneOagw Tel="ACTIVE" gs=7 PA=0
08:30 pointto
StoneOagw Tel="ACTIVE" gs=2 PA=-90
08:30 takepic 2.0
08:33 takepic 1.0
08:35 offset 30 0
08:36 offset 0 0
08:37 The parameter WFS_lenslet_edge_x has been changed at 354.7
08:38 pointto
StoneOagw Tel="ACTIVE" gs=2 PA=-90
08:40 offset 30 0
08:41 takeseq 1.0 30
08:42 offset 0 0
08:43 cl< /home/LBTO/iraf/tran_StoneO_mix.cl
08:47 pointto
StoneOagw Tel="ACQUIRE" gs=0 PA=0 PAM-
CA=-15.5 IE=-22
Discussion with Doug about the validity to use GS with R~16.5-17.5.
trans_StoneO_mix.cl need to be modified
09:03 cl< /home/LBTO/iraf/tran_StoneO_mix2.cl
- first : 090420 cube 134
- last : 091343 cube 140
09:19 cl< /home/LBTO/iraf/tran_StoneO_mix3.cl
- first : 092004 cube 141
- last : 094709 cube 158
09:30 : Seeing ~0.8"
10:03 cl< /home/LBTO/iraf/tran_StoneO_mix4.cl
- first : 100445 cube 159
- last : 100751 cube 161
the WFS stopped by itself.
10:12 pointto
StoneOagw Tel="ACTIVE" gs=2 PA=-90
10:15 cl< /home/LBTO/iraf/tran_StoneO_mix4.cl
- 101628 cube 162
- 104355 cube178
strange WFS image : /Repository/20100705/GCS/wfscimage000486.fits
strange WFS image : /Repository/20100705/GCS/wfscimage000495.fits
THESE TWO "STRANGE IMAGES" ARE ALWAYS THE FIRST AFTER SENDING PRESET.
Dice5 data
10:47 pointto BS9188 Tel="ACTIVE" gs=29 PA=0 Elevation 75deg
Failed because of AGw out of range.
10:50 pointto BS9188 Tel="ACTIVE" gs=29 PA=90
10:50 offset 30 0
10:51 takeseq 2.0 30
10:52 offset 0 0
10:53 dice5 5x5 RADEC 2.0 30 3 :
- first : 105341 cube180
- last : 111315 cube 193
11:14 pointto BS9101 Tel="ACTIVE" gs=3 PA=0 Elevation 57deg
11:20 offset 30 0
11:21 takeseq 2.0 30
11:22 offset 0 0
11:23 dice5 5x5 RADEC 2.0 30 3 :
- first : 112338 cube 195
- last : 113829 cube 203
failed at loop2 position 4/.
Steve restarted GCS.
11:39 dice5 5x5 RADEC 2.0 30 1 :
- first : 113952 cube 204
- last : 114507 cube 208
11:46 dice5 5x5 RADEC 2.0 30 1 :
- first : 114638 cube 209
- last : 115155 cube 213
Close
11:54 The shell is on rest mode.
12:00 Close. T_air=8.3C, Humidity=53%, Wind=6.2m/s
--
PascaleHibon - 05 Jul 2010