RFBG Commissioning with Adaptive Secondary - 05 April 2010 UT
Night 17:
Observer: DMiller FBian JHill (Tucson)
Telescope Operator: JHill (Tucson)
Telescope Support: MMidkiff
Adaptive Operator & Wind Monitor: RBriguglio (LBTO)
Vibration Operator: JEsguerra
Summary
More training of Doug (and Fuyan) to operate the telescope.
Collected more transformation data with seeing 0.8 - 1.2 arcsec. Residuals seem worse than previously seen.
Had various problems with the shell RIPing or resetting.
Collected Field Aberration Data with the reversed Tip setting from last night.
Problems with the Right Instrument Cooling loop. See Issue 2648.
Completed the DX M3 tests as the seeing degrades beyond 1.5 arcsec.
Had problems with a DX primary mirror panic at the end of the night. See Issue 2649.
Preparations
Andrew reports that we got the sign of the tip correction wrong based on last night's data.
So we haved changed the sign. Tonight we are using Tip=-15 Tilt=-5.
This has the fortuitous effect of getting us off the -Y travel limit for M2.
The DX M2 Pointing Offsets are now dX=+0.255 dY=+0.766 dZ=0 RX=-147.3 RY=+49.1
Details
Open
01:42 Reset Shell
01:46 Kill and restart OSS to unstick M2 hexapod. (The hexapod was not power cycled.)
Assistant telescope operator Miller is starting up the telescope this evening. So John is enjoying the armchair operator's position.
02:04 Reset AZ encoders at 120.
02:10 Runa reports the wind on the balcony is 8 m/s (and nearly 0 in the chamber...ha ha)
02:12 Opening the shutter doors
02:23 pointto Pollux
TelMode = TRACK gs=0 PAM-
02:28 tweak IE and CA to center star (high elevation). Put out of focus and remove coma by moving M2
RY=-200 RY=-40 and IE=-63 CA=-26
02:38 Runa report 5 m/s in chamber and 7 m/s on balcony
02:45 Take a cube of out of focus images for Runa irtc.20100405.024239.fits (single) and irtc.20100405_00079_cube.fits
02:46 pointto M5_0460 (low elevation) to set
IA=-406 and IE=-75
02:52 Turned on Mirror Ventilation (forgot to when we opened)
02:54 pointto BS9143 ACQUIRE gs=0 PAM- to set
IE=-63 CA=-23
02:59 pointto BS9143 ACTIVE gs=0 Collimate down to 200 nm rms in about 5 iterations
(must have missed some presets here in the log during the Doug-Fuyan transition)
03:14 cl < home$tran_StoneE_00.cl seeing is 0.7-0.8 (prepdir before cl < home$tran_StoneE_00.cl )
star |
fits file |
cube file |
PA |
0 |
15 |
irtc.20100405.031533.fits |
irtc.20100405_00080_cube.fits |
27 |
irtc.20100405.031748.fits |
irtc.20100405_00081_cube.fits |
29 |
irtc.20100405.031954.fits |
irtc.20100405_00082_cube.fits |
30 |
irtc.20100405.032202.fits |
irtc.20100405_00083_cube.fits |
14 |
irtc.20100405.032413.fits |
irtc.20100405_00084_cube.fits |
13 |
irtc.20100405.032623.fits |
irtc.20100405_00085_cube.fits |
12 |
irtc.20100405.032837.fits |
irtc.20100405_00086_cube.fits |
1 |
irtc.20100405.033048.fits |
irtc.20100405_00087_cube.fits |
cl < tran_StoneE_mix1.cl
PA |
90 |
27 |
irtc.20100405.033511.fits |
irtc.20100405_00088_cube.fits |
29 |
irtc.20100405.033717.fits |
irtc.20100405_00089_cube.fits |
30 |
irtc.20100405.033925.fits |
irtc.20100405_00090_cube.fits |
PA |
180 |
20 |
irtc.20100405.034146.fits |
irtc.20100405_00091_cube.fits |
18 |
irtc.20100405.034359.fits |
irtc.20100405_00092_cube.fits |
11 |
irtc.20100405.034606.fits |
irtc.20100405_00093_cube.fits |
10 |
irtc.20100405.034813.fits |
irtc.20100405_00094_cube.fits |
PA |
270 |
11 |
irtc.20100405.035039.fits |
irtc.20100405_00095_cube.fits |
10 |
irtc.20100405.035249.fits |
irtc.20100405_00096_cube.fits |
9 |
irtc.20100405.035457.fits |
irtc.20100405_00097_cube.fits |
7 |
irtc.20100405.035705.fits |
irtc.20100405_00098_cube.fits |
03:58 cl < tran_StoneE_mix2.cl, during this script the seeing is at the range of 0.8-1.1.
PA |
0 |
14 |
irtc.20100405.040029.fits |
irtc.20100405_00099_cube.fits |
13 |
irtc.20100405.040235.fits |
irtc.20100405_00100_cube.fits |
| 12 | irtc.20100405.040446.fits | irtc.20100405_00101_cube.fits | a faint nearby star 3" away
1 |
irtc.20100405.040654.fits |
irtc.20100405_00102_cube.fits |
PA |
90 |
28 |
irtc.20100405.040912.fits |
irtc.20100405_00103_cube.fits |
23 |
irtc.20100405.041121.fits |
irtc.20100405_00104_cube.fits |
24 |
irtc.20100405.041334.fits |
irtc.20100405_00105_cube.fits |
There is a bright star on the guider, guide on a wrong star |
PA |
180 |
9 |
irtc.20100405.041556.fits |
irtc.20100405_00106_cube.fits |
7 |
irtc.20100405.041804.fits |
irtc.20100405_00107_cube.fits |
23 |
irtc.20100405.042019.fits |
irtc.20100405_00108_cube.fits |
may be bad because the primary hits the limit, |
24 |
irtc.20100405.042230.fits |
irtc.20100405_00109_cube.fits |
There is a bright star on the guider, guide on a wrong star |
PA |
270 |
8 |
irtc.20100405.042453.fits |
irtc.20100405_00110_cube.fits |
6 |
irtc.20100405.042702.fits |
irtc.20100405_00111_cube.fits |
17 |
irtc.20100405.042917.fits |
irtc.20100405_00112_cube.fits |
04:30 cl < home$tran_StoneE_mix3.cl
PA |
0 |
15 |
irtc.20100405.043221.fits |
irtc.20100405_00113_cube.fits |
1 |
irtc.20100405.043434.fits |
irtc.20100405_00114_cube.fits |
PA |
90 |
21 |
irtc.20100405.043653.fits |
irtc.20100405_00115_cube.fits |
22 |
irtc.20100405.043910.fits |
irtc.20100405_00116_cube.fits |
too dim |
19 |
irtc.20100405.044130.fits |
irtc.20100405_00117_cube.fits |
PA |
180 |
21 |
irtc.20100405.044353.fits |
irtc.20100405_00118_cube.fits |
22 |
irtc.20100405.044529.fits |
irtc.20100405_00119_cube.fits |
out of probe range. bad irtc image, background |
19 |
irtc.20100405.044736.fits |
irtc.20100405_00120_cube.fits |
primary against a limit, image may not be good
PA |
270 |
5 |
irtc.20100405.045016.fits |
irtc.20100405_00121_cube.fits |
no star found in acquisition image |
13 |
irtc.20100405.045229.fits |
irtc.20100405_00122_cube.fits |
primary against a limit, image may not be good |
2 |
irtc.20100405.045447.fits |
rtc.20100405_00123_cube.fits |
There is a bright star on the guider, guide on a wrong star |
05:05 pointto
StoneIagw TelMode=ACQUIRE gs=1 PAM-
change secondary RX to -300 and remove corrections of active optics in primary and click collimate on primary mirror.
IE changes to -45
05:08 pointo
StoneIagw TelMode=ACTIVE gs=0
05: 16 cl < home$tran_StoneI_mix1.cl
PA |
45 |
18 |
irtc.20100405.051642.fits |
irtc.20100405_00124_cube.fits |
21 |
irtc.20100405.051853.fits |
irtc.20100405_00125_cube.fits |
25 |
irtc.20100405.052103.fits |
irtc.20100405_00126_cube.fits |
PA |
135 |
8 |
irtc.20100405.052326.fits |
irtc.20100405_00127_cube.fits |
11 |
irtc.20100405.052541.fits |
irtc.20100405_00128_cube.fits |
21 |
irtc.20100405.052757.fits |
irtc.20100405_00129_cube.fits |
PA |
225 |
10 |
irtc.20100405.053023.fits |
irtc.20100405_00130_cube.fits |
14 |
irtc.20100405.053238.fits |
irtc.20100405_00131_cube.fits |
5 |
irtc.20100405.053451.fits |
irtc.20100405_00132_cube.fits |
PA |
315 |
24 |
irtc.20100405.053755.fits |
irtc.20100405_00133_cube.fits |
13 |
irtc.20100405.054009.fits |
irtc.20100405_00134_cube.fits |
4 |
irtc.20100405.054223.fits |
irtc.20100405_00135_cube.fits |
05:44 cl < home$tran_StoneI_mix2.cl
PA |
225 |
11 |
irtc.20100405.054459.fits |
irtc.20100405_00136_cube.fits |
8 |
irtc.20100405.054714.fits |
irtc.20100405_00137_cube.fits |
13 |
irtc.20100405.054933.fits |
irtc.20100405_00138_cube.fits |
6 |
irtc.20100405.055147.fits |
irtc.20100405_00139_cube.fits |
3 |
irtc.20100405.055400.fits |
irtc.20100405_00140_cube.fits |
PA |
135 |
10 |
irtc.20100405.055626.fits |
irtc.20100405_00141_cube.fits |
17 |
irtc.20100405.055840.fits |
irtc.20100405_00142_cube.fits |
19 |
irtc.20100405.060059.fits |
irtc.20100405_00143_cube.fits |
26 |
irtc.20100405.060312.fits |
irtc.20100405_00144_cube.fits |
PA |
45 |
19 |
irtc.20100405.060615.fits |
irtc.20100405_00145_cube.fits |
22 |
irtc.20100405.060834.fits |
irtc.20100405_00146_cube.fits |
PA |
315 |
22 |
irtc.20100405.061059.fits |
irtc.20100405_00147_cube.fits |
12 |
irtc.20100405.061310.fits |
irtc.20100405_00148_cube.fits |
5 |
irtc.20100405.061527.fits |
irtc.20100405_00149_cube.fits |
2 |
irtc.20100405.061740.fits |
irtc.20100405_00150_cube.fits |
06:24 cl < home$tran_StoneI_mix3.cl
PA |
315 |
25 |
irtc.20100405.062453.fits |
irtc.20100405_00151_cube.fits |
14 |
irtc.20100405.062702.fits |
irtc.20100405_00152_cube.fits |
6 |
irtc.20100405.062915.fits |
irtc.20100405_00153_cube.fits |
3 |
irtc.20100405.063121.fits |
irtc.20100405_00154_cube.fits |
PA |
225 |
9 |
irtc.20100405.063343.fits |
irtc.20100405_00155_cube.fits |
16 |
irtc.20100405.063555.fits |
irtc.20100405_00156_cube.fits |
12 |
irtc.20100405.063808.fits |
irtc.20100405_00157_cube.fits |
4 |
irtc.20100405.064020.fits |
irtc.20100405_00158_cube.fits |
2 |
irtc.20100405.064230.fits |
irtc.20100405_00159_cube.fits |
PA |
135 |
9 |
irtc.20100405.064453.fits |
irtc.20100405_00160_cube.fits |
16 |
irtc.20100405.064706.fits |
irtc.20100405_00161_cube.fits |
18 |
irtc.20100405.064919.fits |
irtc.20100405_00162_cube.fits |
20 |
irtc.20100405.065132.fits |
irtc.20100405_00163_cube.fits |
27 |
irtc.20100405.065340.fits |
irtc.20100405_00164_cube.fits |
PA |
45 |
20 |
irtc.20100405.065640.fits |
irtc.20100405_00165_cube.fits |
26 |
irtc.20100405.065852.fits |
irtc.20100405_00166_cube.fits |
06:59 offset 0 -40 to take the back ground image. Then the shell is dead, reset.
07:39 pointto BS9152
TelMode=ACQUIRE gs=0 PAM- The elevation = 69
pointto BS9177
TelMode=ACQUIRE gs=0 PAM- The elevation = 31
Primary against the limit.
start collimate file: wfsc278
Shell reset.
08:30 pointto BS9152
TelMode=ACQUIRE gs=0 PAM-.
pointto BS9152
TelMode=ACTIVE gs=0,
active mode error.
restart GCSR.
resend the preset.. Primary hits the limit, change RX in secondary from -300 to -400. remove the correction of active optics in primary. resend the preset.
lost the guide star. go to the acquire mode and set RX to -350 and adjust IE and CA to put the star in the center and then set RX to -400 and play with
IE and CA to put the star in the center. Go to active mode to collimate.
Field Aberration Data
08:54 cl < home$field_BS9152.cl
The primary hits the limit. Set RX to 420. The wrong script name uses LFBG parameters.
09:20 cl < home$newfield_BS9152_right.cl
GStar |
wfscimage# |
Sequence |
1 |
0 |
9 - 13 |
17 |
14 - 16 |
0 |
17 - 19 |
18 |
20 - 22 |
0 |
23 - 25 |
7 |
26 - 28 |
0 |
29 - 31 |
4 |
32 - 34 |
0 |
35 - 37 |
1 |
38 - 40 |
0 |
41 - 43 |
9 |
44 - 46 |
0 |
47 - 49 |
Sequence |
2 |
0 |
50 - 54 |
17 |
55 - 57 |
0 |
58 - 60 |
18 |
61 - 63 |
0 |
64 - 66 |
7 |
67 - 69 |
0 |
70 - 72 |
4 |
73 - 75 |
0 |
76 - 78 |
1 |
79 - 81 |
0 |
82 - 84 |
9 |
85 - 87 |
0 |
88 - 90 |
10:00 Discover that right side instrument cooling loop temperature is up to 7 degC when it should be 0 degC. From Runa's telemetry plot, it seems the failure
happened about midnight (3 hours ago). Reading on IC page of ECS says CV0424 is at 103%. But when John sends a manual command to 50%, the apparent value jumps to 2% (closed). Note that there is no ECS alarm for this case (pumps are still running). See Issue 2648.
Low-elevation collimation
11:02 pointto BS9131
TelMode=ACTIVE gs=0 elevation=22 to check collimation at low elevation.
Apr 5 11:04:24 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 588.573 0 0 -110.879 537.464 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Apr 5 11:05:08 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 473.947 631.846 606.183 -52.7452 366.097 108.491 -17.2522 -248.401 0 0 0 0 0 0 0 0 0 0 0
Apr 5 11:06:03 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -851.171 0 0 68.2029 125.179 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Apr 5 11:06:43 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -578.142 920.859 99.5814 7.29454 69.8581 -228.593 -5.74796 164.425 0 0 0 0 0 0 0 0 0 0 0
Apr 5 11:07:24 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -275.269 436.574 -28.0351 29.808 -3.72734 -134.092 -4.71848 65.4037 0 0 0 0 0 0 0 0 0 0 0
Apr 5 11:08:03 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -298.161 444.686 90.6393 -24.5791 97.7588 -176.521 74.0611 89.8753 0 0 0 0 0 0 0 0 0 0 0
Apr 5 11:08:44 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -366.152 362.105 16.0823 11.1312 -5.89536 -137.61 17.8443 75.3973 0 0 0 0 0 0 0 0 0 0 0
Apr 5 11:09:23 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -209.034 287.249 136.524 4.68573 46.312 -6.53692 26.0713 25.0467 0 0 0 0 0 0 0 0 0 0 0
Apr 5 11:10:03 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -123.493 185.021 59.6372 20.8754 10.384 -51.0525 13.4202 31.1355 0 0 0 0 0 0 0 0 0 0 0
Apr 5 11:10:43 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -36.0132 148.44 30.1374 -10.1305 -22.0116 -76.276 2.42176 2.37393 -0 -0 -0 -0 -0 -0 0 -0 0 -0 -14.9297
Apr 5 11:11:23 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -180.934 259.293 79.4949 9.39771 17.759 -54.3403 16.057 19.9945 0 0 0 0 0 0 0 0 0 0 0
Apr 5 11:12:02 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -150.858 217.308 82.6865 6.67482 3.04474 -56.5111 31.5071 52.4288 0 0 0 0 0 0 0 0 0 0 0
Apr 5 11:12:41 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -81.5015 146.531 91.5999 21.6089 5.18267 -65.6098 27.9636 26.633 0 0 0 0 0 0 0 0 0 0 0
Apr 5 11:13:21 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 124.127 60.3453 10.544 -33.0009 20.6949 -10.5354 32.5323 13.2056 -0 -0 -0 -0 -0 0 0 -0 0 -0 -19.1628
Apr 5 11:14:02 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -12.1108 129.349 100.722 -2.78523 31.9094 -36.9729 39.3651 29.8172 -0 -0 -0 -0 -0 -0 0 -0 0 -0 -18.0617
Apr 5 11:14:41 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -78.6121 112.729 23.2599 -65.3618 8.25143 -17.293 35.1441 1.42131 -0 -0 -0 -0 -0 0 0 -0 0 -0 -12.5818
Apr 5 11:15:22 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -68.7581 30.7959 77.2477 22.0484 25.0274 -30.5641 52.9028 5.20929 -0 0 -0 -0 -0 -0 -0 -0 0 -0 -14.0696
Apr 5 11:16:02 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -16.924 82.1336 -70.8436 10.3042 6.38059 -14.7091 18.2819 -16.6667 -0 -0 -0 -0 -0 -0 0 -0 0 -0 -10.6517
Apr 5 11:16:41 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 57.7932 -26.0198 31.104 22.3348 -12.929 -47.7966 -10.3355 -13.8259 -0 0 -0 -0 -0 -0 0 -0 0 -0 -12.6909
Apr 5 11:17:21 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 -17.0492 -62.611 37.4457 32.4732 -17.8366 -36.4707 -1.46401 -21.4575 -0 0 -0 -0 -0 -0 0 -0 0 -0 -8.35444
Apr 5 11:18:01 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 89.2932 98.9705 9.51283 -7.46258 7.4654 -15.1122 23.8037 -20.636 -0 -0 -0 -0 -0 0 0 -0 0 -0 -12.036
Apr 5 11:18:41 tcs3 LBT_PSFR: ACTOPT: Primary Zernikes 0 0 177.75 -11.7824 -5.29433 28.6938 3.08855 -13.4451 -16.8335 -6.17109 -0 0 -0 -0 -0 -0 0 -0 0 -0 -16.4399
11:20 The DX primary mirror is panic, raise the primary and there is a big coma. Why was this coma vastly different after we recovered the panic?
M3 Tests - Repeatability
11:38 pointto BS9177
TelMode=ACQUIRE gs=0 PAM-
center the guide star in the acquire field,
11:40 Test: home the Tertiary mirror the guide star disappear, and then collimate Tertiary mirror the star coming back within ~1 arcsec (limited by tracking drift)
11:48 Test: put tip and tilt -200 and 200, home the Tertiary mirror, take off the values and collimate Tertiary mirror the star coming back within ~1 arcsec.
11:53 Test: Home the Tertiary mirror selector and go back to RFBG, the star coming back again within ~1 arcsec.
M3 Tests - Scale of Motion
move the star from the center to the edge of the guider acquire field. First the tip = +140 arcsec (moves to low on left edge), and then the tilt = +230 arcsec (moves to top near upper left corner). This seems like correct behaviour as far as our sleepy brains can tell. Coordinates are rotated from parallactic by the selector angle to feed the particular focal station.
12:05 pointto BS9177
TelMode=ACTIVE, gs=0 .
GCS is dead (hung on the preset), restart GCSR and resend the preset.
Induced Panic
12:12 Press the button to induce an artificial panic to see of the collimation position is repeatable.
12:20 Torque switch set in hardpoint 0. This ends our night with DX M1.
Close
12:30 Close Dome