Sky was mostly clear so we were open all night. However, the high altitude seeing was poor. So data on AGw transformations is not as good as could be hoped. The best seeing we saw was 1 arcsec, and it was between 1.7 and 2.2 arcsec for the second half of the night.

Found two places in the astrometric catalog files where the proper motion of the central star was wrong. This explains some (but perhaps not all) of the problems of this night and last.

Lost 0.5 hour to AGW4 not moving the probe.

Lost 1 hour to telescope problems related to MCSPU in two separate incidents.

We got about 28 stars in a set of pointing model data. Doug turned these into a new pointing model and we were able to test it with another 38 stars at the end of the night. This is the only really productive activity in 2 arcsec seeing.

Lost 0.5 hour to OSS not moving the secondary. But it looks like that was going on for several hours, so more data may have been lost.

Had relatively minor issues with GCS and GCSGUI.

Preparations

Vikings 17 Steelers 27 !!!

Details

All Times in UT

Vent doors open before sunset.

Open

00:45 Open T=3.5 degC, D=-9.6 degC, Sky mostly clear. Wind 4-6 m/sec.

00:52 pointto M5_1526 ACQUIRE gs=0 PAM- - The image/movie on GCSGUI didn't arrive.

00:56 stop and restart GCSL.

00:57 pointto M5_1526 ACQUIRE gs=0 PAM- This time we get the image/movie displayed OK.

00:59 offset 180 180

01:02 Send TRACK preset

01:03 We can't get a readGuideCam image for flats, but we can get readWFSimage.

[telescope@lbtmu41 091026]$ readGuideCam -e 10000
readGuideCam: acquiring full guider image ...
GCS side: L
exposureTime = 10000 ms
guide image invalid!

01:06 pointto M5_1526 ACQUIRE gs=0 PAM- Guide or movie image fails to arrive again.

01:08 stop GCSL. stopAGW. startAGW Home AGW.

01:12 pointto M5_1526 ACQUIRE gs=0 PAM- Now we get the movie OK. Adjust IE=10 CA=23 at EL=71 deg

01:17 pointto M5_1526 gs=2 TelM="ACTIVE" for initial collimation. We are still using the 10 sec initial WFS exposure time, so that makes this process significantly faster. Seeing is varying 1-1.5 arcsec.

01:24 offset 0 0 to force M2 offload, but it didn't do anything.

01:25 focus 0, did force an offload. Secondary Offload register is X=-0.983 Y=-2.286 Z=+0.321 RX=-24.57 RY=+10.65

StoneO AGw Transformation Data

We are at it early in mediocre seeing to try to get a different field than StoneA from last night.

01:29 pointto StoneOagw gs=0 TelM="ACQUIRE" PAM- Adjust IE=13 CA=-3 at EL=52.75 deg.

01:34 pointto StoneOagw gs=11 TelM="ACTIVE" PA=INDEF=18.96

Seeing is variable from 1.0 to 1.4 arcsec on guider at EL=54 deg.

01:39 cl < home$tran_StoneO_00.cl
transtar (21) missed because IRTC was in video mode.
transtar (17) failed for uncertain reason
transtar (11) irtc.20091026.014335.fits cube 119
transtar (32) irtc.20091026.014552.fits cube 120 (star is faint)
transtar (9)
transtar (19)
transtar (4)
transtar (8)
transtar (1)
transtar (37)
transtar (21)
transtar (17)
transtar (11)

01:19 Doug's GCSGUI displayed downtown from lbtmu43 crashes.

02:02 John's GCSGUI on lbtmu42 crashes.

This became Issue #2410.

02:09 cl < home$tran_StoneO_180.cl
transtar (24) irtc.20091026.021055.fits cube 130
CA=+3 Seeing now worse than 1.5 arcsec. transtar (18) irtc.20091026.021305.fits cube 131
transtar (12) irtc.20091026.021517.fits cube 132

02:16 Clear C00 as we are getting bad influence forces from PSF. Actuator 101 was at -125 # correction. This makes enough defocus plus bad seeing, that the guider can't really see the star image any more. The last 20 minutes of WFS images were numbers 49 - 88 to be checked later by Doug.

02:19 pointto StoneOagw gs=0 TelM="ACTIVE" to get a brighter star. failed to find stable guiding on the out of focus donut.

02:22 pointto StoneOagw gs=0 TelM="ACQUIRE" PAM-

02:27 put default WFS exposure time back to 30000 msec in AIP_IRTC_DG_L.cfg. stop and restart GCS,

Killed and restarted my IRAF window because of pipe errors.

02:30 pointto StoneOagw gs=0 TelM="ACTIVE" - Even after careful collimation, the seeing is still 1.6 to 2.2 arcsec on the guider.

02:39 Force on actuator 101 =-28#
02:43 -36#
02:47 -35#
02:55 -47#
03:02 -44#
03:06 -40#
03:13 +9#
03:20 +83#

My impression is that the divergence of the correction forces is only happening when the seeing is 2 arcsec or worse.

What is the little image below the WFS spots on the WFScam image? Could it been the moon or something else in a direct image of the sky?

Seeing is 1.2 to 1.5 arcsec on the guider in the following data.

03:05 cl < home$tran_StoneO_180.cl transtar (24) irtc.20091026.030738.fits cube 133
transtar (18) irtc.20091026.030952.fits cube 134
transtar (12) irtc.20091026.031211.fits cube 135
transtar (28)
transtar (6)
transtar (31)
transtar (20)
transtar (23)
transtar (3)
transtar (15)
transtar (27)
transtar (33)
transtar (14)
transtar (5)
transtar (38)
transtar (24)
transtar (18) irtc.20091026.033524.fits cube 149 - No star - Couldn't move probe.
Mon Oct 26 03:35:09.331 2009  Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) 56.3201, 59.9614, focus: 30.0375 :AGw command status: AGW4: Error moving the motor(s)error: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 56.3201, 59.9614, 30.0375 mm.

We didn't catch it, but the probe had not been moving correctly since 03:22:24. This makes lots of "interesting" structure in Doug's plot. See Issue #2411.

03:37 stop GCS, stopAGW, startAGW, home AGw, start GCSL. Lost 15 min.

JMH: Warning after the fact: It appears that the RA proper motion for the central star in StoneO is 15 times too large.

StoneA AGw Transformation Data (with central star proper motion)

03:42 pointto M5_0036 gs=0 TelM="ACQUIRE" PAM- - Adjust IE=-6 CA=+2 at EL=49.7 deg

03:47 pointto StoneAagw gs=12 TelM="ACTIVE" PA=0 Seeing is 1.2 arcsec on guider at EL=46 deg.

We are taking this data, but seeing is sufficiently (1.2-1.4 arcsec) bad that it may not be very useful.

03:53 cl < home$tran_StoneA_00.cl
transtar (12) irtc.20091026.035444.fits cube 150
transtar (16)
transtar (17) irtc.20091026.035933.fits cube 152
transtar (18)
transtar (14)
transtar (12)
transtar (6)
transtar (5)
transtar (3)
transtar (12)
transtar (11)

04:21 cl < home$tran_StoneA_90.cl
transtar (12)
transtar (13) irtc.20091026.042520.fits cube 162
transtar (15)
transtar (19)
transtar (20)
transtar (21)
transtar (16)
transtar (17)
transtar (18)
transtar (14)
transtar (12) irtc.20091026.044636.fit cube 171

IE=-4 CA=+8

04:48 cl < home$tran_StoneA_180.cl
transtar (13) irtc.20091026.044930.fits cube 172
transtar (15)
transtar (19)
transtar (20)
transtar (21)
transtar (9) failed to find star - this is the background frame. See below.
transtar (2)
transtar (13)

4:51 Terminal running ds9 and CGSGui froze on downtown workstation. The terminal started on lbtdu16 was ssh connected to lbtssh then lbtmu43. A GCSGui was start from that terminal around 1:20 and ds9 started around 4:38. All three froze around 4:50. When I do a "ps" on lbtmu43 I see:
LBTO@lbtmu43:9 % ps aux | grep GCS
LBTO     31062  1.1  0.5  63476 49664 pts/1    S    01:20   2:27 GCSGUI left
LBTO     31295  0.4  0.1  23728 14244 pts/1    S+   04:38   0:04 ds9 /Repository/GCSfiles/dailyimages/wfscimage000187.fits
LBTO     31397  0.0  0.0   3912   684 pts/3    S+   04:57   0:00 grep GCS
at 4:58 the two process above stopped (did not show up with ps ) and about minutes later the terminal on lbtdu16 reported:
LBTO@lbtmu43:33 % ds9 /Repository/GCSfiles/dailyimages/wfscimage000187.fits 
Read from remote host lbtssh: Connection reset by peer
Connection to lbtssh closed.
[LBTO@lbtdu16 ~]$ 
I was interacting with ds9, so I don't think it is an ssh "disconnect due inactivity" problem. Doug

04:59 Executed B23-Test 16. all-on-source flag seems to work fine.

05:00 transtar (9) from above failed to find the star. This is because the right side authorization from the B23-Test 16 reset the left side pointing model. This was not the behaviour I was expecting from a left-centric monocular PCS.

05:02 Put IE=-4 CA=+12 to restore pointing.

Pointing Model Data

05:13 Stop last night's pointing file and start a fresh one. /home/telescope.Pointing_26Oct09UT

PSF is running in default mode, so secondary offloads are being applied.

Working from directory /OldRepository/IRTC_Data/091026_Pointing/

05:16 gopoint 1 - This failed and telescope dropped to TRACK mode. Why? It seems that the preset didn't get through. Because I forgot to prepdir this new directory.

05:22 gopoint 1 WT10_353 irtc.20091026.052605.fits cube 180

05:27 gopoint 2 ACT0404 - MCS/MCSPU go into a funny state that requires them to be restarted. MCSPU won't restart correctly. Call Tom S. Tom says it stopped tracking because it didn't like the polynomials. They were stale by 1.06 sec. Then the restart problem seemed to have something to do with the optical support state machine. Tom will investigate that more on Monday.

05:48 gopoint 2 - ACT0404 irtc.20091026.055236.fits cube 181

05:54 pointto ACT0404 ACQUIRE - Adjust *IE=-25 CA=-58 * at EL=21.8 deg

05:57 gopoint 3 - WT10_398 irtc.20091026.060026.fits cube 182

06:01 gopoint 4 - WT10_362 irtc.20091026.060424.fits cube 183

06:05 gopoint 5 - ACT0270 irtc.20091026.060755.fits

06:08 gopoint 6 - WT10_185 irtc.20091026.061457.fits cube 185 -16/-25

06:15 gopoint 7 - WT10_259 irtc.20091026.061830.fits -16/15

Changed WFS default exposure time back to 10000 msec.

06:20 gopoint 8 WT10_087 irtc.20091026.062317.fits -16/-58

06:23 gopoint 9 WT10_157 irtc.20091026.062652.fits -16/-40

06:27 gopoint 10 ploop+ ACT0263 irtc.20091026.063019.fits

11 ACT0214 irtc.20091026.063357.fits

12 ACT0316 irtc.20091026.063709.fits

13 WT10_329 irtc.20091026.063840.fits (This is the WRONG star - I think.)

Error below happened here too.

14 ACT0284

Mon Oct 26 06:39:18.780 2009  Preset alert for left IRTC mode ACTIVE: OK
Mon Oct 26 06:39:18.830 2009  Preset alert for left IRTC mode ACTIVE: PCS could not start tracking because ERROR: MCSPU is not connected.
Mon Oct 26 06:39:18.880 2009  Preset command failed for left IRTC mode ACTIVE from IIF

15 WT10_267

Same error here.

06:43 Stop and restart MCSPU.

06:47 gopoint 13 WT10_344 - Same error.

06:48 Stop and restart PCS.

06:49 gopoint 13 WT10_344 - Same error. irtc.20091026.065003.fits cube 194 are BACKGROUND images.

06:50 Stop PCS, MCS and MCSPU. And restart pointing log Pointing2_26Oct09UT. Lost 30 minutes in this episode.

06:58 gopoint 13 WT10_344 - irtc.20091026.070111.fits

07:02 gopoint 14 ploop+ ACT0284 irtc.20091026.070435.fits cube 196

Mon Oct 26 07:06:40 UTC 2009 15 23 WT10_267 irtc.20091026.070742.fits cube 197

Mon Oct 26 07:10:41 UTC 2009 16 83 WT10_312 irtc.20091026.071140.fits cube 198

Mon Oct 26 07:15:05 UTC 2009 18 8 ACT0091 irtc.20091026.071607.fits cube 199

Mon Oct 26 07:18:02 UTC 2009 19 29 WT10_121 irtc.20091026.071903.fits cube 200

Mon Oct 26 07:22:14 UTC 2009 20 85 WT10_295 irtc.20091026.072315.fits cube 201

Mon Oct 26 07:25:52 UTC 2009 21 57 ACT0259 irtc.20091026.072651.fits cube 202

Mon Oct 26 07:29:19 UTC 2009 22 12 ACT0202 irtc.20091026.073020.fits cube203

Mon Oct 26 07:32:26 UTC 2009 23 35 ACT0291 irtc.20091026.073326.fits cube 204

Mon Oct 26 07:36:24 UTC 2009 24 87 WT10_340 irtc.20091026.073724.fits cube 205

Mon Oct 26 07:40:16 UTC 2009 25 64 WT10_400 irtc.20091026.074115.fits cube 206

Mon Oct 26 07:43:29 UTC 2009 26 16 WT10_403 irtc.20091026.074430.fits cube 207

Mon Oct 26 07:46:32 UTC 2009 27 17 WT10_407 irtc.20091026.074729.fits cube 208

Mon Oct 26 07:49:45 UTC 2009 29 43 ACT0379 irtc.20091026.075045.fits cube 209

Mon Oct 26 07:56:24 UTC 2009 17 51 WT10_193
GOPOINT: !ssh agwuser@lbtmu105 'cd agw-control;setxy -x 0 -y 500 -u 4'
ERROR: cannot open `uparm$pipe15752' for writing
  "print (agw_cmd) | cl"
     line 129: home$gopoint.cl
     called as: `gopoint (gridID=17)'
irtc.20091026.075747.fits cube 210 (probably probe was still in)

Mon Oct 26 08:01:49 UTC 2009 28 81 ACT0342 irtc.20091026.080316.fits cube 211

Mon Oct 26 08:06:07 UTC 2009 1 66 WT10_368 irtc.20091026.080730.fits cube 212 (but probe was still in) irtc.20091026.080941.fits cube 213 (has the star)

StoneC

Restart IRAF

Stop pointing log.

08:12 pointto StoneCagw gs=0 TelM="ACQUIRE" PAM- - Adjust IE=2 CA=1 at EL=57.5 deg

08:18 pointto StoneCagw gs=18 ACTIVE - Seeing is 1.5 - 1.7 arcsec on guider.

IDL Field Data Collection Tests

08:30 execute an IDL> agw_wfsc_multiple, 1. The irc_client.conf file was not available in /tmp. Need to fix my IDL routine to put it there automatically

8:35 execute an IDL> agw_wfsc_multiple, 1. Successful

8:40 add a stepfocus to agw_wfsc_multiple to force application of collimation LUT. First time fail because "DEFAULT" in not an option for ope in the call. Change it to 'M1M2".

8:45 Success

8:50 execute agw_collimate. Successful, other than M2 appears to still be in motion.

9:00 Collimation with IDL was successful, but M2 PSF gui show yellow for x,y,z, etc. However, PSFL did not report a failed collimation (with M2) in its events. Why? John and Wayne working on it.

09:15 Moved Hexapod so star was out of guide box. However, Sextractor found star along left edge where the first column was brighter than the rest of the image. See /Repository/GCSfiles/20091026/guiderimage004350.fits through 4371 (or so...)

09:16 The recovery was that we had to restart OSS twice. Then we cleared active optics in PSFL and started afresh.

Based on the IRTC headers, it looks like M2 was stuck in this position, and thus not collimating correctly since 05:52 UT. (around the time we were on the phone with Tom)

09:20 pointto StoneCagw gs=0 TelM="ACQUIRE" PAM- IE=5 CA=-10

09:24 pointto StoneCagw gs=18 TelM="ACTIVE" - but it lost the star between bad seeing and coma.

09:28 clear active optics again and then pointto StoneCagw gs=0 TelM="ACTIVE"

09:33 pointto StoneCagw gs=18 TelM="ACTIVE"

09:35 put WFScam_exposureTime back to its 30000 default. (but didn't restart GCS here)

09:40 Sent a couple agw_collimate IDL routines, which were successful. Ready to collect field data. (If the seeing turns decent.)

09:50 stop guiding, stop and restart GCSL to get the default exposure time.

StoneC Tranformation Data (in very poor seeing)

Decided to take some data in this 1.8 to 2 arcsec seeing, just to exercise the system. I don't expect this data is worth reducing.

09:52 cl < home$tran_StoneC_00.cl
transtar (10) irtc.20091026.095224.fits cube 214
transtar (14)
transtar (15)
transtar (12) This star is probably the magnitude limit when the seeing is 2 arcsec. GCS isn't even able to measure the FWHM.
transtar (18)

Seeing improves a little to 1.5 arcsec.

10:03 cl < home$tran_StoneC_180.cl
transtar (13)
transtar (16) irtc.20091026.100658.fits cube 220
transtar (17)
transtar (7) irtc.20091026.101150.fits cube 222

10:12 cl < home$tran_StoneC_225.cl
transtar (13) irtc.20091026.101423.fits cube 223
transtar (16)
transtar (17)
transtar (7)
transtar (4)
transtar (5)
transtar (9)
transtar (13)

StoneE

10:32 pointto StoneEagw gs=0 TelM="ACQUIRE" PAM- - Adjust *IE=0 CA=-17 * at EL=51 deg.

10:36 pointto StoneEagw gs=15 TelM="ACTIVE"

Mon Oct 26 10:38:05.388 2009  Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) 0.116549, 88.5548, focus: 29.5123 :AGw command status: timed out waiting for probe to reach destination
Mon Oct 26 10:38:05.438 2009  Preset alert for left IRTC mode ACTIVE: couldn''t move probe to position (SFP) 0.116549, 88.5548, focus: 29.5123 :AGw command status: timed out waiting for probe to reach destinationerror: setProbePosition: couldn''t move probe to position (SFP) (x,y,z): 0.116549, 88.5548, 29.5123 mm.

10:40 stop GCSL. stopAGW, startAGW, home, start GCS.

10:42 pointto StoneEagw gs=15 TelM="ACTIVE"
Mon Oct 26 10:43:20.200 2009  Preset alert for left IRTC mode ACTIVE: size: full CCD, exptime: 0 mserror: couldn''t request a full CCD readout for GS acquisition. Error is -99

10:43 Stop GCSL. Start GCSL.

10:44 pointto StoneEagw gs=15 TelM="ACTIVE"

10:48 cl < home$tran_StoneE_00.cl
transtar (15) irtc.20091026.104918.fits cube 231
transtar (27)
transtar (29)
transtar (30)
transtar (14)
transtar (13)
transtar (12)
transtar (1)

11:07 cl < home$tran_StoneE_90.cl
transtar (27) irtc.20091026.110857.fits cube 239
transtar (29)
transtar (30)
transtar (26) star was out of range
transtar (28)
transtar (23)
transtar (24)
transtar (21)
transtar (22) might have selected the wrong star in a crowded field
transtar (19) irtc.20091026.112919.fits cube 248

11:30 pointto StoneEagw gs=0 TelM="ACQUIRE" PAM- IE=2 CA=-5

11:33 cl < home$tran_StoneE_180.cl
transtar (20) irtc.20091026.113516.fits cube 249
transtar (18) irtc.20091026.113741.fits cube 250

Interupted to test the new pointing model.

Testing new pointing model by collecting more data

11:39 Stop and restart PCS to load the new model = irtcdg.20091026.ptmod. And start a pointing log file Pointing3_26Oct09UT.

Taking these in TRACK mode, so guider is not centering the stars on IRTC. All these images were taken with the initial values of IE/CA in the model. No manual intervention was required, although we did miss a couple stars.

11:41 gopoint 1 cube 251

11:46 gopoint 2 active- irtc.20091026.114905.fit cube 252

11:50 gopoint 3 active- ploop+

3 39 WT10_400 irtc.20091026.115126.fits cube 253

4 78 ACT0344 irtc.20091026.115347.fits cube 254

5 13 may have missed. ACT0278 irtc.20091026.115629.fits

Oops. gopoint.cl skips the log entry in track mode. Fixed it here.

12:02 gopoint 6 active- ploop+

Mon Oct 26 12:02:16 UTC 2009 6 32 WT10_176 irtc.20091026.120222.fits cube 256

Mon Oct 26 12:04:24 UTC 2009 7 74 ACT0250 irtc.20091026.120429.fits cube 257

12:05 Note the zodiacal light, or gegenschein, or sun pillar or something on the all-sky camera in the east. The pointing model data makes for a great time-lapse on the all-sky camera.

Mon Oct 26 12:06:44 UTC 2009 8 9 ACT0095 irtc.20091026.120650.fits cube 258

Mon Oct 26 12:08:48 UTC 2009 9 26 ACT0165 irtc.20091026.120854.fits cube 259

Mon Oct 26 12:10:53 UTC 2009 10 70 WT10_271 irtc.20091026.121058.fits cube 260

Mon Oct 26 12:13:11 UTC 2009 11 5 WT10_222 irtc.20091026.121317.fits

Mon Oct 26 12:15:06 UTC 2009 12 21 WT10_337 irtc.20091026.121511.fits cube 262

Mon Oct 26 12:16:30 UTC 2009 13 45 WT10_322 irtc.20091026.121636.fits cube 263

Mon Oct 26 12:18:05 UTC 2009 14 22 WT10_275 irtc.20091026.121811.fits cube 264

Mon Oct 26 12:19:35 UTC 2009 15 23 WT10_239 irtc.20091026.121940.fits cube 265

Mon Oct 26 12:22:19 UTC 2009 16 83 WT10_303 irtc.20091026.122225.fits cube 266 (missed)

Mon Oct 26 12:24:48 UTC 2009 17 51 WT10_182 irtc.20091026.122453.fits cube 267

Mon Oct 26 12:26:34 UTC 2009 18 8 WT10_097 irtc.20091026.122640.fits cube 268

Mon Oct 26 12:28:13 UTC 2009 19 29 WT10_144 irtc.20091026.122819.fits cube 269

Mon Oct 26 12:30:48 UTC 2009 20 85 ACT0286 irtc.20091026.123053.fits cube 270

Mon Oct 26 12:33:12 UTC 2009 21 57 WT10_248 irtc.20091026.123317.fits cube 271

Mon Oct 26 12:35:00 UTC 2009 22 12 ACT0210 irtc.20091026.123505.fits cube 272

Mon Oct 26 12:36:41 UTC 2009 23 35 WT10_297 irtc.20091026.123647.fits cube 273

Mon Oct 26 12:39:40 UTC 2009 24 87 WT10_318 irtc.20091026.123946.fits cube 274 (missed at EL=86)

Mon Oct 26 12:42:05 UTC 2009 25 64 WT10_397 irtc.20091026.124211.fits cube 275

Mon Oct 26 12:44:06 UTC 2009 26 16 WT10_405 irtc.20091026.124412.fits cube 276

Mon Oct 26 12:45:47 UTC 2009 27 17 WT10_409 irtc.20091026.124552.fits cube 277

Mon Oct 26 12:48:43 UTC 2009 28 81 ACT0333 irtc.20091026.124849.fits cube 278 (maybe missed at EL=85.5? - no)

12:49 pointto ACT0333 gs=0 ACQUIRE PAM- (didn't miss, was faint)

12:51 gopoint 29 active- ploop+

Mon Oct 26 12:53:32 UTC 2009 29 43 ACT0383 irtc.20091026.125337.fits cube 279

Mon Oct 26 12:55:26 UTC 2009 30 2 WT10_376 irtc.20091026.125531.fits cube 280

Mon Oct 26 12:57:02 UTC 2009 31 18 WT10_399 irtc.20091026.125707.fits cube 281 (maybe missed?)

Mon Oct 26 12:58:50 UTC 2009 32 40 ACT0410 irtc.20091026.125856.fits cube 282

Mon Oct 26 13:00:56 UTC 2009 33 79 WT10_370 irtc.20091026.130101.fits cube 283

Mon Oct 26 13:03:16 UTC 2009 34 15 WT10_375 irtc.20091026.130322.fits cube 284

Mon Oct 26 13:05:03 UTC 2009 35 37 ACT0355 irtc.20091026.130512.fits cube 285

Mon Oct 26 13:07:11 UTC 2009 36 61 ACT0357 irtc.20091026.130726.fits cube 286

Mon Oct 26 13:09:16 UTC 2009 37 77 ACT0316 irtc.20091026.130924.fits cube 287

Mon Oct 26 13:10:59 UTC 2009 38 76 WT10_301 irtc.20091026.131112.fits cube 288

Mon Oct 26 13:13:16 UTC 2009 39 33 WT10_231 irtc.20091026.131323.fits cube 289

Mon Oct 26 13:14:57 UTC 2009 40 11 ACT0159 irtc.20091026.131504.fits cube 290

13:16 Stop pointing log

Close

13:17 Close for impending dawn. T=-0.8 degC, D=-26.8 degC, apparent wind 8 m/sec. Sky clear - approaching photometric.

-- DougMiller - 21 Oct 2009
I Attachment Action Size Date Who Comment
daq.20091026.gifgif daq.20091026.gif manage 50 K 27 Oct 2009 - 07:59 JohnHill Plot of Telescope and Mirror Temperatures
Topic revision: r10 - 12 Nov 2009, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback