Telescope and AGw Commissioning at LFBG with IRTC - 05-06 April 2009 MST

Observers: J. Hill (mtn), D. Thompson (Tucson, first half), J. Storm (Potsdam)
Telescope Operator: A. Ceranski
Telescope Support: J. Hill

Summary

Winds are down, clouds are thin, seeing is moderate and telescope is in a happy mood. So we got a fair set of data for a new measurement of the AGw probe transformation. Jesper is analyzing it now. The initial result is that this data set has much larger residuals than the March 16 data. This may be due to the poor seeing tonight. We certainly had lots of image motion on the scale of a 2 second exposure.

Jesper writes later in the morning:
  I have placed a new transform on the agw-control computer. The name
is /etc/oacontrol/oacontrol.conf.basic20090406. You can substitute the
existing oacontrol.conf file with the new one at your leisure.
  It is based on 45 data points excluding only star #19 which is a double.
  The transform is a simple orthogonal transform without the pinhole offset as
the data are too noisy for determining this possible offset. The RMS of the
transform is 260 microns in X and Y, which is about 0.15arcsec. So we are more
than a factor 3 off where we would like to be. The transform should bring the
star well on the rotation axis, the zero point is (-0.14,612.50) in excellent
agreement with the alignment from  yesterday. The rotation angle is
178.7degree, which differs from the previous angle of 180.3 deg.

We continue to have problems with elevation pointing after resetting encoders, and tonight we can't blame it on temperature gradients. Azimuth matches the IRTC pointing model from months ago, while elevation has a 3 arcminute offset.

Closed for clouds at 3:30 AM.

We got Dave's LBTtools.IRTC.center3 script working to take an IRTC image and then offset the specified star onto the rotator center. It now works at all position angles.

Preparations

Butch says he put 60# of freon in the utility bldg chillers this morning.

Details

Open

We are authorized as IRTC on the left side.

18:20 Reset Encoders

18:35 Open Shutter Doors and Vent Doors, T=-0.4 degC, D=-20 degC, Wind 2-4 m/sec from East, scattered thin cirrus. Primary mirror is starting out at -2.1 degC, so mirror ventilation is heating it. Telescope steel is fairly close to ambient.

18:55 Slew to zenith to put the DX M2 Swing arm in so that Doug can collect anemometer data in the "deployed" position. This is our new strategy to be sure that the wind doesn't blow for the rest of the week. smile Dave A. is rebalancing from Tucson.

For the second time, the reset encoders at EL=3 gave us a wrong zenith position of 90.06 (motor encoders) or 90.11 (strip encoders) for the position with stow pins lined up.

All active optics have been cleared from PSFL-M1 including Secondary Offload and Pointing Offsets.

19:21 pointto M5_1246 gs=0 TelM="ACQUIRE" PAM- -no star seen.

This slew put in a small, but non-zero amount of M2 offload on the primary.

19:24 source ptspiral_irtc.csh - went around whole 4x4 arcmin grid without finding an M5 star.

19:33 slew to horizon to check the stow pin positions down there. We found the horizon stow pin indicators at +0.08 deg (strip encoders) or +0.06 (motor encoders).

19:37 elencreset 3 2 failed on first try.

19:38 Cleared residual Secondary Offload corrections and collimated M1 at horizon.

19:40 Wind (LBTO) is up to 10 m/sec, so I guess Doug gets some data after all.

19:50 slew to horizon to check the stow pin positions again. Now lineup is +0.05 deg (strip encoder) or +0.06 (motor encoder).

19:53 pointto M5_1246 gs=0 TelM="ACQUIRE" PAM- -no star seen.

This slew put in a small, but non-zero amount of M2 offload on the primary.

Search manually in elevation, and found the star with IE=-122 CA=-57 (2 arminutes in EL from the nominal pointing model of IE=-4 CA=-69) but still with some coma.

20:06 Adding +5 arcsec RX means I need more negative IE (to move star back down on ACQUIRE image). Added at total of RX=+25 arcsec of M1 tip so that active optics has less raw coma to correct in a pointing-free manner. This moves us to IE=-170 with global offsets Z=+0.6 and RX=+25.

BS9122

20:13 pointto BS9122 gs=0 TelM="ACTIVE" PA=0 - found star in corner of acquisition image. GCS correctly identified it despite 3 arcsec FWHM and still slightly comatic.

This slew put in a small, but non-zero amount of M2 offload on the primary. That might have been correct for the few minutes since my last manual collimation update.

20:25 focus 0, After some collimation and focussing, the seeing is varying between 1.1 and 1.5 arcsec FWHM.

M5_0347

20:30 pointto M5_0347 gs=0 TelM="ACTIVE" PAM- - remarakbly GCS started guiding on this bright star, but I meant to say ACQUIRE.

20:34 pointto M5_0347 gs=0 TelM="ACQUIRE" PAM- Adjust IE=-171 CA=-55

20:37 pointto M5_0347 gs=1 TelM="ACTIVE" PA=INDEF=91.52 - found star 5 arcsec left of hotspot. x:-1.69 y:498.89

20:43 center2 - irc OffsetPointing 0.0 -0.55 9.676 RADEC MOUNT true ABS left

20:44 center2 - irc OffsetPointing 0.0 -0.61 10.539 RADEC MOUNT true ABS left

20:46 center2 - irc OffsetPointing 0.0 -0.594 11.404 RADEC MOUNT true ABS left

20:48 center2 - irc OffsetPointing 0.0 -0.575 13.251 RADEC MOUNT true ABS left

20:56 pointto M5_0347 gs=1 TelM="ACTIVE" PA=90 x:+1.26 y:498.88 - seeing improved to 1 arcsec.

takepic 0.01 - irtc.20090406.035849.fits

takeseq 0.01 50 - 00001_cube

21:01 offset 0 10

Sun Apr 5 20:59:43.581 2009 setting none mode on left side

Apr  5 20:57:16.436: LFBG RTracker:Slew done. state-->TRACKING, pos'n= 316760.3 v=-4996.44
Apr  5 20:57:16.436: LFBG RTracker:State changed from SLEW_TO_TRACK --> TRACKING
Apr  5 20:57:16.788: MCSPU: AZ/EL ON_SOURCE just became TRUE
Apr  5 20:57:20.111: LFBG RTracker:Just changed to Rotator ON_SOURCE
Apr  5 20:57:56.496: MCSPU: AZ/EL ON_SOURCE just became FALSE
Apr  5 20:57:58.444: MCSPU: AZ/EL ON_SOURCE just became TRUE
Apr  5 20:59:39.043: LFBG RTracker:Just changed to Rotator NOT ON_SOURCE !
Apr  5 20:59:39.114: MCSPU: AZ/EL ON_SOURCE just became FALSE
Apr  5 20:59:39.311: AZ Tracker :A slew appears to have started spontaneously while in TRACKING state
Apr  5 20:59:39.311: AZ Tracker :State changed from TRACKING --> SLEW_TO_TRACK
Apr  5 20:59:39.653: AZ Tracker :slew done. position =  191.427deg. vel=     0.023 deg/sec

Apr  5 20:59:39.653: AZ Tracker :Track Poly: t0=4745707213.639 t1=4745707213.689 n=2 seq=3068760  191:24:54.3     28.82  -0.00
Apr  5 20:59:39.653: AZ Tracker :Slew done. state-->TRACKING, pos'n= 689135.5 v=  81.69
Apr  5 20:59:39.653: AZ Tracker :State changed from SLEW_TO_TRACK --> TRACKING
Apr  5 20:59:40.116: AZ Tracker :A slew appears to have started spontaneously while in TRACKING state
Apr  5 20:59:40.116: AZ Tracker :State changed from TRACKING --> SLEW_TO_TRACK
Apr  5 20:59:40.259: LFBG RTracker:Just changed to Rotator ON_SOURCE
Apr  5 20:59:40.302: AZ Tracker :slew done. position =  191.427deg. vel=    -0.007 deg/sec

Apr  5 20:59:40.302: AZ Tracker :Track Poly: t0=4745707214.289 t1=4745707214.339 n=2 seq=3068773  191:25:13.0     28.82  -0.00
Apr  5 20:59:41.092: AZ Tracker :A slew appears to have started spontaneously while in TRACKING state
Apr  5 20:59:41.092: AZ Tracker :State changed from TRACKING --> SLEW_TO_TRACK
Apr  5 20:59:41.171: LFBG RTracker:Just changed to Rotator NOT ON_SOURCE !
Apr  5 20:59:42.110: AZ Tracker :slew done. position =  191.429deg. vel=     0.020 deg/sec

Apr  5 20:59:42.110: AZ Tracker :Track Poly: t0=4745707216.090 t1=4745707216.140 n=2 seq=3068809  191:26:04.9     28.82  -0.00
Apr  5 20:59:42.110: AZ Tracker :Slew done. state-->TRACKING, pos'n= 689143.0 v=  71.99
Apr  5 20:59:42.110: AZ Tracker :State changed from SLEW_TO_TRACK --> TRACKING
Apr  5 20:59:42.243: AZ Tracker :A slew appears to have started spontaneously while in TRACKING state
Apr  5 20:59:42.244: AZ Tracker :State changed from TRACKING --> SLEW_TO_TRACK
Apr  5 20:59:42.387: LFBG RTracker:Just changed to Rotator ON_SOURCE
Apr  5 20:59:42.637: AZ Tracker :slew done. position =  191.444deg. vel=     0.014 deg/sec

Apr  5 20:59:42.638: AZ Tracker :Track Poly: t0=4745707216.640 t1=4745707216.690 n=2 seq=3068820  191:26:20.8     28.82  -0.00
Apr  5 20:59:42.638: AZ Tracker :Slew done. state-->TRACKING, pos'n= 689196.8 v=  51.61
Apr  5 20:59:42.638: AZ Tracker :State changed from SLEW_TO_TRACK --> TRACKING
Apr  5 20:59:45.976: MCSPU: AZ/EL ON_SOURCE just became TRUE

21:06 pointto M5_0347 gs=1 TelM="ACTIVE" PA=90 - and continue guiding while talking to Tom on the phone.

Azimuth servo is having rms servo error around 0.7 arcsec, so small excursions from this may be tripping on_source bit. Tom says minimum time off source is 2 sec even for a short excursion.

takeseq 0.01 50 - 00002_cube

21:17 offset 0 10

takeseq 0.01 50 - 00003_cube

21:19 offset -5 10

takeseq 0.01 50 - 00004_cube

21:20 offset -5 0

takeseq 0.01 50 - 00005_cube

21:20 pointto M5_0347 gs=2 TelM="ACTIVE" PA=INDEF=120.28

21:22 pointto M5_0347 gs=2 TelM="ACTIVE" PA=120

takeseq 0.01 50 - 00006_cube

offset 0 10

takeseq 0.01 50 - 00007_cube

offset -5 10

takeseq 0.01 50 - 00008_cube

21:28 pointto M5_0347 gs=4 TelM="ACTIVE" PA=0 - x:-139.13 y:576.01 - star appears ~4 arcsec left of hotspot

21:30 WFS image has horrible scattered light and glints

takeseq 0.01 50 - 00009_cube

offset 0 10

takeseq 0.01 50 - 00010_cube

21:33 offset -5 10

takeseq 0.01 50 - 00011_cube

21:46 pointto M5_0347 gs=1 TelM="ACTIVE" PA=90 to get an orientation without so much flare in WFS

offset 0 -15

Blank frames for the above data : takeseq 0.01 50 - 00012_cube, 00013_cube, 00014_cube

Vibration and Tracking Data

Telescope AZ=217 EL=53, IRTC wide field, Wind 4 m/sec (LBTO) from West. Guiding on with 4.6 sec exposures, and WFS is running. Seeing on guider is varying from 0.9 to 1.3 arcsec FWHM. Single frames accompanying the cubes have header information.

21:59 takeseq 0.01 3000 = 00015_cube It wrote the cube to disk at 22:03, but the IRAF task doesn't come back until 22:07.

22:07 takeseq 0.01 3000 = 00016_cube

Switch to configuration 2 - medium field, but this star isn't bright enough for exposures less than 50 ms in this seeing.

22:20 Dave T. installs new version of LBTtools with "center3" for adjusting positons on IRTC.

BS9145

22:21 pointto BS9145 gs=0 TelM="ACTIVE" PA=0 - no star in acq image

22:26 pointto M5_0387 gs=0 ACQUIRE PAM- Adjust IE=-177 CA=-75

22:29 pointto BS9145 gs=0 ACQUIRE PAM- Adjust IE=-175 CA=-79

22:32 pointto BS9145 gs=8 TelM="ACTIVE" PA=0 - found star 6 sec left of hotspot in acq image.

center3

center3

offset 30 30 to get sky frame

takepic 2.0 irtc.20090406.054129.fits

offset 0 0

22:43 center3 irtc.20090406.054327.fits irc OffsetPointing 0.0 0.855 7.644 RADEC MOUNT true ABS left

22:44 center3 irtc.20090406.054443.fits irc OffsetPointing 0.0 1.71 15.288 RADEC MOUNT true ABS left

22:45 center3 irtc.20090406.054521.fits star out of frame

22:48 offset 0 0

center3 irtc.20090406.055144.fits irc OffsetPointing 0.0 6.235 0.251 RADEC MOUNT true ABS left

center3 irtc.20090406.055304.fits irc OffsetPointing 0.0 18.506 -0.1 RADEC MOUNT true ABS left went wrong way

fixed

center3 star was off chip

22:55 offset 0 0

center3 irtc.20090406.055541.fits irc OffsetPointing 0.0 -6.033 0.251 RADEC MOUNT true ABS left

center3 irtc.20090406.055612.fits irc OffsetPointing 0.0 -6.231 0. RADEC MOUNT true ABS left

22:58 offset 0 0

Jesper data on BS9145

22:59 already on gs=8 at PA=0 takepic 2 - irtc.20090406.055927.fits

23:00 pointto BS9145 gs=6 PA=0 takepic 2 - irtc.20090406.060237.fits

23:03 pointto BS9145 gs=9 PA=0 takepic 2 - irtc.20090406.060512.fits

23:05 pointto BS9145 gs=4 PA=0 - no star found

23:07 pointto BS9145 gs=4 PA=0 ACQUIRE

23:10 pointto BS9145 gs=0 PAM- ACQUIRE - Adjust IE=-178 CA=-76

23:12 pointto BS9145 gs=16 PA=0 takepic 2 - (found 5 arcsec lower left) irtc.20090406.061413.fits

23:17 pointto BS9145 gs=18 PA=0 - no star found

23:20 pointto BS9145 gs=20 PA=0 - couldn't move probe there

23:22 pointto BS9145 gs=14 PA=180 - no star found

23:23 pointto BS9145 gs=15 PA=180 - takepic 2 irtc.20090406.062433.fits (moonlight in WFS)

23:25 pointto BS9145 gs=19 PA=180 - takepic 2 irtc.20090406.062838.fits (moonlight in WFS)

23:29 pointto BS9145 gs=17 PA=180 - takepic 2 irtc.20090406.063051.fits

23:32 pointto BS9145 gs=7 PA=180 - takepic 2 irtc.20090406.063447.fits (jumped) irtc.20090406.063504.fits

23:35 pointto BS9145 gs=12 PA=180 - no star found

23:37 pointto BS9145 gs=1 PA=180 - couldn't move probe

23:38 pointto BS9145 gs=3 PA=180 - couldn't move probe

23:39 pointto BS9145 gs=3 PA=270 - star is there but too faint

23:41 pointto BS9145 gs=7 PA=270 - takepic 2 - irtc.20090406.064349.fits (0.7 arcsec seeing)

23:44 pointto BS9145 gs=8 PA=270 - takepic 2 - irtc.20090406.064640.fits

23:47 pointto BS9145 gs=6 PA=270 - takepic 2 - irtc.20090406.064821.fits

23:49 pointto BS9145 gs=17 PA=90 - takepic 2 - irtc.20090406.065124.fits

23:51 pointto BS9145 gs=19 PA=90 - takepic 2 - irtc.20090406.065442.fits (binary star)

23:54 pointto BS9145 gs=15 PA=90 - takepic 2 - irtc.20090406.065655.fits

23:57 pointto BS9145 gs=20 PA=90 - takepic 2 - irtc.20090406.065939.fits

00:00 pointto BS9145 gs=20 PA=135 - couldn't move probe

00:01 pointto BS9145 gs=19 PA=135 - takepic 2 irtc.20090406.070524.fits (binary star) JMH did getdat

00:05 pointto BS9145 gs=17 PA=135 - takepic 2 - irtc.20090406.070852.fits JMH did getdat

00:09 pointto BS9145 gs=15 PA=135 - takepic 2 - irtc.20090406.071200.fits JMH did getdat

00:13 pointto BS9145 gs=7 PA=135 - takepic 2 - irtc.20090406.071528.fits JMH did getdat

00:16 pointto BS9145 gs=7 PA=225 - takepic 2 - irtc.20090406.071743.fits JMH did getdat

00:18 pointto BS9145 gs=1 PA=225 - didn't find star

00:20 pointto BS9145 gs=0 PA=225 ACQUIRE - Adjust IE=-178 CA=-71

00:22 pointto BS9145 gs=1 PA=225 - still didn't find star

00:25 pointto BS9145 gs=8 PA=315 - takepic 2 - irtc.20090406.072652.fits JMH did getdat

00:27 pointto BS9145 gs=6 PA=315 - takepic 2 - irtc.20090406.072918.fits JMH did getdat

0029 pointto BS9145 gs=9 PA=315 - takepic 2 - irtc.20090406.073126.fits JMH did getdat

00:32 pointto BS9145 gs=8 PA=275 - takepic 2 - irtc.20090406.073418.fits JMH did getdat

00:36 pointto BS9145 gs=8 PA=285 - takepic 2 - irtc.20090406.073757.fits JMH did getdat

00:38 pointto BS9145 gs=8 PA=295 - takepic 2 - irtc.20090406.074000.fits JMH did getdat

00:40 pointto BS9145 gs=8 PA=305 - takepic 2 - irtc.20090406.074159.fits JMH did getdat

00:42 pointto BS9145 gs=8 PA=325 - takepic 2 - irtc.20090406.074414.fits JMH did getdat

00:45 pointto BS9145 gs=8 PA=335 - takepic 2 - irtc.20090406.074749.fits JMH did getdat (seeing explodes from 0.7 to 1.4) Aaron says sky is 50% cirrus.

00:50 pointto BS9145 gs=8 PA=345 - takepic 2 - irtc.20090406.075050.fits JMH did getdat

00:51 pointto BS9145 gs=8 PA=355 - takepic 2 - irtc.20090406.075304.fits JMH did getdat

00:53 pointto BS9145 gs=8 PA=5 - takepic 2 - irtc.20090406.075538.fits JMH did getdat

00:56 pointto BS9145 gs=8 PA=15 - takepic 2 - irtc.20090406.075832.fits JMH did getdat

00:59 pointto BS9145 gs=8 PA=25 - takepic 2 - irtc.20090406.080026.fits JMH did getdat

01:00 pointto BS9145 gs=8 PA=35 - takepic 2 - irtc.20090406.080214.fits JMH did getdat

01:02 pointto BS9145 gs=8 PA=55 - takepic 2 - irtc.20090406.080354.fits JMH did getdat

01:04 pointto BS9145 gs=8 PA=65 - takepic 2 - irtc.20090406.080534.fits JMH did getdat

01:06 pointto BS9145 gs=8 PA=75 - couldn't move probe

01:07 pointto BS9145 gs=7 PA=145 - takepic 2 - irtc.20090406.080917.fits JMH did getdat

01:09 pointto BS9145 gs=7 PA=155 - takepic 2 - irtc.20090406.081123.fits JMH did getdat (bad seeing)

01:12 pointto BS9145 gs=7 PA=165 - takepic 2 - irtc.20090406.081313.fits JMH did getdat (bad seeing)

01:13 pointto BS9145 gs=7 PA=175 - takepic 2 - irtc.20090406.081501.fits JMH did getdat

01:15 pointto BS9145 gs=7 PA=185 - takepic 2 - irtc.20090406.081709.fits JMH did getdat

01:17 pointto BS9145 gs=7 PA=195 - takepic 2 - irtc.20090406.081857.fits JMH did getdat

01:19 pointto BS9145 gs=7 PA=205 - takepic 2 - irtc.20090406.082034.fits JMH did getdat

01:21 pointto BS9145 gs=7 PA=215 - takepic 2 - irtc.20090406.082308.fits JMH did getdat (bad seeing)

01:23 pointto BS9145 gs=7 PA=235 - takepic 2 - irtc.20090406.082527.fits JMH did getdat

01:25 pointto BS9145 gs=8 PA=0 - takepic 2 - irtc.20090406.082813.fits JMH did getdat

01:28 center3 irtc082841.fits (got goofy coords) Source indicated at coords (2046,2042)

01:30 offset 0 0

01:32 center3 irtc.20090406.083122.fits irc OffsetPointing 0.0 -5.731 -0.351 RADEC MOUNT true ABS left

01:32 takepic 2 - irtc.20090406.083216.fits This is gs=8 at PA=0 offset onto the rotator center.

01:33 pointto BS9145 gs=7 PA=180 - takepic 2 - irtc.20090406.083609.fits JMH did getdat

01:36 center3 irtc.20090406.083649.fits irc OffsetPointing 0.0 7.241 -3.268 RADEC MOUNT true ABS left

01:37 takepic2 - irtc.20090406.083733.fits

01:38 center3 irtc.20090406.083823.fits (John key clicked at wrong time so additional offset was meaningless.) center3 did work correctly at PA=180.

01:39 takepic2 - irtc.20090406.083942.fits - an additional background frame with clouds

01:49 offset 0 0

Probe data is saved by getdat in /home/agwuser/logbook.1

LUCI LEFTZEROPOINT from March 2009 was -187.703 deg before AGw3 was dismounted. This data with IRTC was taken with that same angle using IRTC (which may not be the optimum angle for IRTC itself in April),

IRTC data is in /Repository/ and will later be moved to /Repository/IRTC_Data/090406/

BS9152

01:56 pointto BS9152 gs=0 TelM="ACQUIRE" PAM- - star not found

01:58 pointto M5_0531 gs=0 TelM="ACQUIRE" PAM- Adjust IE=-164 CA=-73

02:04 pointto BS9152 gs=0 TelM="ACTIVE" PA=0 (seeing 0.8 to 1.0)

02:11 pointto BS9152 gs=12 TelM="ACTIVE" PA=180 - takepic 2 - irtc.20090406.091450.fits getdat

02:16 pointto BS9152 gs=11 TelM="ACTIVE" PA=180 - takepic 2 - irtc.20090406.091840.fits getdat

02:20 pointto BS9152 gs=1 TelM="ACTIVE" PA=180 - takepic 2 - irtc.20090406.092244.fits getdat

02:24 pointto BS9152 gs=1 TelM="ACTIVE" PA=INDEF=229.72 - takepic 2 - irtc.20090406.093228.fits getdat

02:34 center3 irtc.20090406.093446.fits irc OffsetPointing 0.0 3.124 -4.074 RADEC MOUNT true ABS left

02:40center3 irtc.20090406.093638.fits irc OffsetPointing 0.0 3.279 -4.334 RADEC MOUNT true ABS left - Center3 worked OK at PA=229.72.

M92 for astrometric orientation

02:52 pointto M92astrom gs=0 ACTIVE PA=0

02:58 pointto M92astrom TRACK - IRTC can't see an interesting number of stars, so IRTC orientation will have to come from the offsets I did earlier.

03:04 pointto M92astrom gs=0 ACTIVE PA=0 - In this combination of poor seeing, thick cirrus and moon, there is no chance of getting any astrometric data on the guider either.

Azimuth Pointing Tests (again) - looking for something to do through thick clouds

03:13 pointto M5_0619 gs=0 TelM="ACQUIRE" PA=0

03:15 Turn on pointing log /home/telescope/060409.ptlog

03:16 Adjust IE=-173 CA=-74

03:17 pointto M5_0619 gs=0 TelM="ACTIVE" PA=0 (seeing around 2 arcsec and variable 1.2 to 3 with 1 arcsec image motion) WFS saturates when seeing improves, so it is kind of a catch 22 on this star.

03:25 block guiding on PCS

03:28 unblock guiding

03:29 pointto M5_0619 gs=0 TelM="GUIDE" PA=0 to get the acquisition image 00074 @AZ=362.8 EL=55.9

03:30 azslewtohold 0 - dropped to None mode as expected

03:36 pointto M5_0619 gs=0 TelM="GUIDE" PA=0 to get the acquisition image 00075 @AZ=1.8 EL=54 The M5 star was off the edge of the field although the guider picked it up. This seems to be at odds with the azimuth scale data I took a few days ago.

Close

03:28 Close for passing clouds and radar echoes.

Appendix of a test in the afternoon - Issue 2116

from lbtmu102:
top - 16:01:18 up 15 days, 20:02,  2 users,  load average: 0.98, 2.92, 3.54
Tasks:  80 total,   1 running,  79 sleeping,   0 stopped,   0 zombie
Cpu(s):  1.3% us,  0.7% sy,  0.0% ni, 97.7% id,  0.3% wa,  0.0% hi,  0.0% si
Mem:   1034616k total,   736108k used,   298508k free,    33844k buffers
Swap:  2621432k total,    20048k used,  2601384k free,   433436k cached

  PID USER      PR  NI  VIRT  RES  SHR S %CPU %MEM    TIME+  COMMAND
32309 telescop  15   0  340m  32m 6264 S  3.0  3.2  64:53.94 PCS
 5459 telescop  15   0  6292 2472 2232 S  0.7  0.2 107:11.19 gshmserver
 5486 telescop  15   0  888m 196m 8980 S  0.7 19.4  41:54.75 IIF
    1 root      16   0  2220  464  436 S  0.0  0.0   0:00.86 init

16:10 Walter restarts LUCIFER connection to TCS doing multiDD queries. It hasn't been running since ~April 1.

top - 17:14:45 up 15 days, 21:16,  2 users,  load average: 2.40, 2.98, 3.32
Tasks:  80 total,   1 running,  79 sleeping,   0 stopped,   0 zombie
Cpu(s):  1.8% us,  0.8% sy,  0.0% ni, 78.7% id, 18.5% wa,  0.2% hi,  0.0% si
Mem:   1034616k total,   697380k used,   337236k free,    33752k buffers
Swap:  2621432k total,    20048k used,  2601384k free,   386988k cached

  PID USER      PR  NI  VIRT  RES  SHR S %CPU %MEM    TIME+  COMMAND
32309 telescop  15   0  340m  32m 6264 S  2.3  3.2  66:58.60 PCS
 5459 telescop  15   0  6292 2472 2232 S  1.3  0.2 108:14.97 gshmserver
 5486 telescop  15   0  895m 203m 8980 S  1.3 20.1  43:08.43 IIF
  241 root      15   0     0    0    0 D  0.3  0.0  24:18.48 kjournald
 2247 root      16   0  1992  744  612 D  0.3  0.1  28:08.74 syslogd
    1 root      16   0  2220  464  436 S  0.0  0.0   0:00.86 init
    2 root      RT   0     0    0    0 S  0.0  0.0   0:00.36 migration/0

18:37 Walter stops the LUCIFER connection to TCS.

-- JohnHill - 04 Apr 2009