7-8 January 2009

Telescope/TCS Checkout for LUCIFER Com3
UT 2009 January 08

Observers: D.Thompson, N.Ageorges, W.Seifert, M.Juette (@LBT), ARakich (Tucson)
Software Support: T.Leibold (Tucson)
Telescope Operator: Aaron Ceranski

Summary:

  • MCR rotator lockout problem at beginning of night - lost 3 hrs. IT# 1943
  • Only 2 EL encoders working IT# 1941
  • Initial collimation with new model is very poor - why?
  • Many problems with GCS losing guide thread (lost connection).
  • Oscillations seen on encoders, IT# 1940
  • Significant problems with GCS losing the guide thread. (Est. another 2h lost)

  • Verified isCollimated Flag works as expected
  • AGw Z-axis appears orthogonal
  • Field aberration measurements show little problems
  • Took 24 star pointing dataset.
  • Collimation corrections appear to be applied double, see below
  • 3a: With Z11/Z22 gains at zero we could collimate and not move the primary (all sent to secondary).
  • 3b: Under tonight's conditions you do not build up bending forces too rapidly.
  • Cannot edit the lbt.conf file in /lbt/tcs/17/etc/ unless you are root, 3c not done
  • Nominal AGw-LUCIFER focus should shift 1.956mm to 29.630 mm (will implement tomorrow)
  • Some astigmatism visible in LUCIFER images.

GCS WFSC /Repository/AGW_Data/090109_w and field data in 090108w (DLM)

Guider images in /Repository/AGW_Data/090108g (DLM)

Details:

11:30 T=2.0, RH=21.2

16:30 Spoke with Torsten. Compile problems on oacserver code postpones this test until tomorrow.

17:30 T=2.5, RH=13.8 Wind is still around 15m/s from the LBT weather station.
It has been above 0C outside for ~9+ hours, hopefully that has fixed the blowing snow problem.

17:45 Motor Control Relay (MCR) lockout for rotator. A physical bypass of a faulty LUCIFER sensor applied on 02 Jan was apparently removed today. It is being replaced.

Not completely photometric at sunset. There are scattered thin cirrus around. Jet contrails persist for quite some time. T=2.7, RH=10.3, Wind ~13m/s average.

19:00 rotator MCR lockout diagnosis: a blown fuse. It is being changed out.

19:36 Everything working on MCR. Now getting R_HW fault - 3-phase power not on (done 17:45).

19:55 Dome open

20:12 Rising temps and pressures. T=4.5, RH=7.7%, P=690.7

20:15 Enclosure rotation problem (not enabled). "TPLC" error? Back up.

20:43 Encoder reset complete, EL encoder 0 is still disabled. Aaron's recommendation is to not do a pointing model with only the two EL encoders working.

  • 3 hr in total lost including the encoder reset that could not be done earlier.

20:45 Preset to BS9108 TRACK/PARALLACTIC for pointing correction IE changed from -14.91 to +97.0, CA went from -10.65 to +32

UT03:55:02 Preset from LUCIFER to BS9108 failed. It looked like a second preset overwrote the initial coordinates (05h RA instead of 03h). See Issue Trak #1939

Resent preset. Succeeded, but the guider saw a couple of significant jumps The sequence started at 21:03:59 and through a couple attempts ended a little after 21:12:00.

Cleared active optics and sent ACQUIRE mode through iraf, on axis. Huge coma and focus. Why? We are using the new multi-night LUCIFER collimation model with improved temperature coefficients, and it covers the current temperature. Global offsets applied +2 Y on M1 and M2 to bring Y into range, and 0.6mm in Z to focus.

Guiding window on GCS GUI is not updating but the WFS does see a star. The syslog keeps repeating:
Jan 7 21:34:31 lbtmu107 LBT_left_GCS: error requesting an image in GuidingThread. Lost connection?

Verified isCollimated Flag works as expected (off on presets and offsets and rms>400nm; on when the next WFS image is <400nm.)

21:47 MCS pre-processor algorithm verification (30 minutes):
  • Offsets 20 arcsec each NE 60, 120, 240, 600 arcsec
  • dawdle-snap seems gone, faster response
  • Data: luci_20090107_tst_NNNN.fits
    LUCI# Observation Description
    0005 - 0043  
  • Results:

Quick focus sequence with LUCIFER to check field aberrations
Collimate at BS9107 and resend preset in TRACK mode

Had to restart GCS:
Wed Jan 7 22:38:45.996 2009 GCSL wouldn't stop.
Wed Jan 7 22:39:00.229 2009 GCSL murdered.

luci_20080107_foc_NNNN.fits
  • 0001 -1500 nm Z4 applied to secondary
  • 0002 -750nm
  • 0003 0 nm
  • 0004 +750
  • 0005 +1500
  • 0006 0 nm

Images do not have telescope information in the headers (have not all night).

23:00:40 +/- a few seconds we had a significant jump in focus (2303nm)

Wed Jan 7 23:25:51.589 2009 IIF wouldn't stop. (but it shows as stopped on the TCSGUI). Kill did nothing. Manually stopped IRS, killed IIF, started IIF, started IRS. I can now authorize and preset from iraf as LUCIFER. Something has hung on the LUCIFER side, recovering.

IE changed to 110 from 97.

00:05 Moving to BS9122 Have to update pointing: CA=13, IE=80

00:22:03 Preset to BS9122 timed out after 300s. The MCSPU GUI disappeared. EL looks odd, executing wait_opr.

LUCIFER fits headers now OK

BS9122 - Field Aberration Measurements because we see significant astigmatism in LUCIFER images
GStar X Y PA Doug's Angle wfscimage000*
0 3.463 612.288 0.00 -194 2-16

SX primary mirror actuator enabled during the first set of collimation data on axis (so more iterations than normal).

6 2.178 414.993 295.03 -499 17-19
0 3.463 612.288 295.03 -502 21-22
24 2.403 466.232 349.12 -199 23-25
0 3.405 612.335 349.12 -200 26-28

IE changed to 90. and CA to 10. and a few minutes later, IE changed to 101. and CA to 18.

0 3.285 611.849 93.00 -315 34-36
46 2.106 424.375 93.00 -XXX no images

01:19:10 GCS appears to have hung, stopping and restarting

0 3.300 611.885 93.00 -318 38-39
46 2.106 424.369 93.00 -319 40-41
0 3.285 611.880 93.00 -321 42-44

IE changed to 110, CA to 0.0

0 3.300 611.868 93.00 -324 45-46
45 3.285 611.880 113.64 -325 no star
0 3.300 611.868 93.00 -324 47
42 3.285 611.880 113.64 -325 no star
0 3.270 611.864 93.00 -328 48-51

6 2.258 415.055 295.03 - no star

01:58:14 IE changed to 94.0 CA to 26 on WT10_359

Pointing seems to be a significant problem, taking a short set of data:

02:01 BS9122 GS06 to collimate

02:15 Start Pointing model run (24 stars)
  • LUCIFER internal flexures are corrected? (they are not)
  • Measure mechanical rotator center coords on LUCIFER (images 1-2 and 21-22) *
  • New rotator center: X Y =
  • Pointing log in PCS GUI (/home/telescope/20090108.ptlog)
  • Data: luci_20090107_ptg_NNNN.fits
    # LUCI# Star ID   # LUCI# Star ID   # LUCI# Star ID

1 WT10_403 18 39 4.738 +72 57 34.09 -.00030 0.01400 0001 PA=0
WT10_403 18 39 4.738 +72 57 34.09 -.00030 0.01400 0002 PA=180
2 ACT0402 04 59 29.344 +71 36 28.30 -.00150 -.02700 0003 PA=0
3 WT10_350 10 44 00.620 +46 12 23.96 -0.0259 -0.062 0004 PA=0 (substitute star)
4 ACT0346 07 12 29.997 +43 59 19.94 0.00020 -.01200 0005 PA=0
5 ACT0282 04 26 18.500 +21 28 13.55 0.00760 -.03800 0006 PA=0
6 ACT0197 06 35 35.846 -02 14 34.78 0.00760 -.12500 0007 PA=0
7 ACT0271 08 39 44.665 +19 16 30.76 -.00250 -.01400 0008 PA=0
8 WT10_097 08 10 51.429 -32 22 46.45 -.00150 0.03800 0009 PA=0
9 WT10_169 11 37 20.116 -12 20 49.90 0.00340 -.09500 0010 PA=0
10 WT120_239 10 49 03.257 +10 09 28.45 -0.0029 -0.013 0011 PA=0
11 ACT0226 13 57 56.785 +05 07 3.83 -.00070 -.01800 0012 PA=0

  • Had to reset telescope drives twice because of some oscillation seen on the encoders. Also had to restart GCS in order to free the preset as seen from LUCIFER. Why?

13 WT10_339 13 10 1.291 +38 43 25.49 -.00320 -.00200 0013 PA=0
14 WT10_294 13 23 46.747 +25 32 52.50 -.00340 0.01000 0014 PA=0
15 WT10_243 13 34 20.900 +14 06 39.75 0.00270 -.01200 0015 PA=0
16 WT10_290 10 26 15.480 +24 42 55.21 0.00170 -.00500 0016 PA=0
17 ACT0203 10 27 35.527 -00 57 46.49 0.00060 0.00000 0017 PA=0
18 WT10_071 10 24 56.965 -38 18 11.77 -.00120 -.00700 0018 PA=0
19 ACT0131 09 23 14.578 -21 02 15.84 -.00210 0.01300 0019 PA=0
20 WT10_273 09 47 42.833 +20 36 17.15 0.00530 -.00400 0020 PA=0
21 ACT0252 07 29 20.235 +13 31 44.37 0.00000 0.01700 0021 PA=0
ACT0252 07 29 20.235 +13 31 44.37 0.00000 0.01700 0022 PA=180
22 ACT0214 05 57 48.680 +02 03 56.08 -.00130 0.03700 0023 PA=0
23 ACT0284 05 54 54.008 +22 31 11.82 0.00080 0.01000 0024 PA=0
24 ACT0320 09 03 15.742 +32 52 53.09 -.03320 -.01200 0025 PA=0
12 WT10_341 14 42 39.560 +36 45 24.35 0.00240 -.00900 0026 PA=0

  • Generate new pointing model (D.Thompson)
  • Implement:
    • Copy to ~telescope/TCS/Configuration/PCS/
    • Update LUCIFER entry for LEFTPOINTINGMODEL
      in PCSInstrument.conf
    • Re-authorize LUCIFER on IIF GUI to read in new pointing model
  • Test new pointing model

03:18 Measure AGW Z-axis orthogonality (C10+13)

Jan 8 02:36:08 lbtmu107 LBT_left_GCS: TCPSocket::recv error: Transport endpoint is not connected
Stop and restart GCS, resent preset. And again, we got an error:

Thu Jan 8 03:43:11.274 2009 Preset alert for left LUCIFER mode ACTIVE: guiding was not stable within 6 cycles

but there is a bright guide star in the acquisition image (0053)

Nevermind - operator error (me), we forgot to restart application of the guiding offsets on PCS.

Restarted PCS and GCS, something odd is happening. No guide star because we forgot to re-enter IE and CA

Thu Jan 8 03:57:39.173 2009 Preset completed. Allow to collimate. GCS just stopped receiving images from AZcam after 1-2 cycles of the WFS. This is the third time in a row this has happened.

guiderimage002125-002134 in closed loop ACTIVE mode stop WFS, guiding, manually take:
  • lbtmu107:/tmp/guider000001-000005.fits at 37.587
  • lbtmu107:/tmp/guider000006-000010.fits at 25.587
  • lbtmu107:/tmp/guider000011-000015.fits at 31.587 all effectively TRACK mode
  • *No big shift between the +/-6mm focus positions (~3 pixels)

Verify collimation updates not double-applied:

04:26:29 GCS again lost the communication with AZCam? And again. 04:30:22 "Guide thread stopped" Why is this not stable?

Stop GCS, stop and restart PCS,

Jan 8 04:35:30 lbtmu107 LBT_left_GCS: star verification failed. Jan 8 04:35:30 lbtmu107 LBT_left_GCS: GCSL:getGuideCamPixelScale executed Jan 8 04:35:30 lbtmu107 LBT_left_GCS: GCSL:getCentroid executed Jan 8 04:35:31 lbtmu107 LBT_left_GCS: guide thread stopped.

Acquisition image 66 has star at 56KDN peak in 2 seconds, is that the problem? We can probably drop the low end of the guider exposure time to 500ms now.

04:39:26 Preset to C10+26, seems to be working. Allow to collimate
Sample guide corrections during this collimating with M1 updating:
Jan  8 04:39:42 lbtmu102 LBT_PCS: Centroid Xarcs: -0.904264746257070 Yarcs: 0.007639188148685 Xmm: -0.542558848857880 Ymm: 0.004583512898535
Jan  8 04:39:48 lbtmu102 LBT_PCS: Centroid Xarcs: -0.913332102825082 Yarcs: 0.003200235653678 Xmm: -0.547999262809753 Ymm: 0.001920141396113
Jan  8 04:39:52 lbtmu102 LBT_PCS: Centroid Xarcs: -0.813463576966852 Yarcs: 0.061039241527532 Xmm: -0.488078147172928 Ymm: 0.036623544991016
Jan  8 04:39:57 lbtmu102 LBT_PCS: Centroid Xarcs: -0.894844033487333 Yarcs: 0.126251789173964 Xmm: -0.536906421184540 Ymm: 0.075751073658466
Jan  8 04:40:02 lbtmu102 LBT_PCS: Centroid Xarcs: -0.887899198315455 Yarcs: 0.108188539523353 Xmm: -0.532739520072937 Ymm: 0.064913123846054
Jan  8 04:40:06 lbtmu102 LBT_PCS: Centroid Xarcs: -0.879555243451396 Yarcs: -0.010404264688438 Xmm: -0.527733147144318 Ymm: -0.006242558825761
Jan  8 04:40:11 lbtmu102 LBT_PCS: Centroid Xarcs: -0.855737128106524 Yarcs: 0.038310345184361 Xmm: -0.513442277908325 Ymm: 0.022986207157373
Jan  8 04:40:18 lbtmu102 LBT_PCS: Centroid Xarcs: -0.817757644579349 Yarcs: 0.033816856573776 Xmm: -0.490654587745667 Ymm: 0.020290113985538
Jan  8 04:40:26 lbtmu102 LBT_PCS: Centroid Xarcs: -0.787236390896672 Yarcs: -0.023050677605272 Xmm: -0.472341835498810 Ymm: -0.013830406591296
Jan  8 04:40:32 lbtmu102 LBT_PCS: Centroid Xarcs: -1.256606079565426 Yarcs: 0.573082565095565 Xmm: -0.753963649272919 Ymm: 0.343849539756775
Jan  8 04:40:35 lbtmu102 LBT_PCS: Centroid Xarcs: -0.904155073710907 Yarcs: 0.056284492100031 Xmm: -0.542493045330048 Ymm: 0.033770695328712
Jan  8 04:40:40 lbtmu102 LBT_PCS: Centroid Xarcs: -0.793727585052194 Yarcs: -0.023664821201606 Xmm: -0.476236552000046 Ymm: -0.014198892749846
Jan  8 04:40:45 lbtmu102 LBT_PCS: Centroid Xarcs: -0.949693916296344 Yarcs: 0.237901334477332 Xmm: -0.569816350936890 Ymm: 0.142740800976753
Jan  8 04:40:49 lbtmu102 LBT_PCS: Centroid Xarcs: -0.726811636002621 Yarcs: -0.060147351152540 Xmm: -0.436086982488632 Ymm: -0.036088410764933
Jan  8 04:40:54 lbtmu102 LBT_PCS: Centroid Xarcs: -0.931604999395630 Yarcs: 0.101706956616781 Xmm: -0.558963000774384 Ymm: 0.061024174094200
Jan  8 04:40:59 lbtmu102 LBT_PCS: Centroid Xarcs: -0.976064203184232 Yarcs: 0.074203467466492 Xmm: -0.585638523101807 Ymm: 0.044522080570459
Jan  8 04:41:04 lbtmu102 LBT_PCS: Centroid Xarcs: -0.884606041698314 Yarcs: 0.092674189369120 Xmm: -0.530763626098633 Ymm: 0.055604513734579
Jan  8 04:41:13 lbtmu102 LBT_PCS: Centroid Xarcs: -0.690184134827813 Yarcs: -0.081188796543832 Xmm: -0.414110481739044 Ymm: -0.048713278025389
Jan  8 04:41:16 lbtmu102 LBT_PCS: Centroid Xarcs: -0.978800155714932 Yarcs: 0.029570820370764 Xmm: -0.587280094623566 Ymm: 0.017742492258549
Jan  8 04:41:23 lbtmu102 LBT_PCS: Centroid Xarcs: -0.986729659616496 Yarcs: 0.420672445633630 Xmm: -0.592037796974182 Ymm: 0.252403467893600
Jan  8 04:41:26 lbtmu102 LBT_PCS: Centroid Xarcs: -0.668113627664201 Yarcs: 0.004982499317996 Xmm: -0.400868177413940 Ymm: 0.002989499596879
Jan  8 04:41:31 lbtmu102 LBT_PCS: Centroid Xarcs: -0.786135840803670 Yarcs: -0.033583706176513 Xmm: -0.471681505441666 Ymm: -0.020150223746896
Jan  8 04:41:35 lbtmu102 LBT_PCS: Centroid Xarcs: -1.081164377715368 Yarcs: 0.233550096076505 Xmm: -0.648698627948761 Ymm: 0.140130057930946
Jan  8 04:41:40 lbtmu102 LBT_PCS: Centroid Xarcs: -0.863836604586428 Yarcs: 0.045782597642396 Xmm: -0.518301963806152 Ymm: 0.027469558641315

04:43:25 "Hold WFS corrections" on PSFL wavefront control GUI
Sample guide corrections during this interval without M1 updating
Jan  8 04:43:43 lbtmu102 LBT_PCS: Centroid Xarcs: -0.835234421779465 Yarcs: -0.008939243834909 Xmm: -0.501140654087067 Ymm: -0.005363546311855
Jan  8 04:43:47 lbtmu102 LBT_PCS: Centroid Xarcs: -0.796946980921577 Yarcs: 0.013346979367406 Xmm: -0.478168189525604 Ymm: 0.008008187636733
Jan  8 04:43:51 lbtmu102 LBT_PCS: Centroid Xarcs: -0.883640347113842 Yarcs: 0.015728245457306 Xmm: -0.530184209346771 Ymm: 0.009436947293580
Jan  8 04:43:56 lbtmu102 LBT_PCS: Centroid Xarcs: -0.883489348680718 Yarcs: 0.181677800544095 Xmm: -0.530093610286713 Ymm: 0.109006680548191
Jan  8 04:44:00 lbtmu102 LBT_PCS: Centroid Xarcs: -0.865507620799307 Yarcs: -0.029569289897336 Xmm: -0.519304573535919 Ymm: -0.017741573974490
Jan  8 04:44:05 lbtmu102 LBT_PCS: Centroid Xarcs: -0.903021492710659 Yarcs: -0.134249143029360 Xmm: -0.541812896728516 Ymm: -0.080549485981464
Jan  8 04:44:10 lbtmu102 LBT_PCS: Centroid Xarcs: -0.966559745888756 Yarcs: 0.280197858240465 Xmm: -0.579935848712921 Ymm: 0.168118715286255
Jan  8 04:44:14 lbtmu102 LBT_PCS: Centroid Xarcs: -0.879447359044572 Yarcs: 0.014903518961850 Xmm: -0.527668416500092 Ymm: 0.008942111395299
Jan  8 04:44:24 lbtmu102 LBT_PCS: Centroid Xarcs: -0.805094240458277 Yarcs: 0.093839602974903 Xmm: -0.483056545257568 Ymm: 0.056303761899471
Jan  8 04:44:28 lbtmu102 LBT_PCS: Centroid Xarcs: -0.865476427701938 Yarcs: 0.021367017136264 Xmm: -0.519285857677460 Ymm: 0.012820210307837
Jan  8 04:44:32 lbtmu102 LBT_PCS: Centroid Xarcs: -0.923945305852200 Yarcs: 0.063120778521649 Xmm: -0.554367184638977 Ymm: 0.037872467190027
Jan  8 04:44:36 lbtmu102 LBT_PCS: Centroid Xarcs: -0.949715473309494 Yarcs: 0.086498080266400 Xmm: -0.569829285144806 Ymm: 0.051898848265409
Jan  8 04:44:41 lbtmu102 LBT_PCS: Centroid Xarcs: -0.798684754336468 Yarcs: -0.006288321831200 Xmm: -0.479210853576660 Ymm: -0.003772993106395
Jan  8 04:44:46 lbtmu102 LBT_PCS: Centroid Xarcs: -0.862124361827663 Yarcs: 0.038163519076363 Xmm: -0.517274618148804 Ymm: 0.022898111492395
Jan  8 04:44:51 lbtmu102 LBT_PCS: Centroid Xarcs: -0.907022454483069 Yarcs: 0.183159187063533 Xmm: -0.544213473796844 Ymm: 0.109895512461662
Jan  8 04:44:55 lbtmu102 LBT_PCS: Centroid Xarcs: -0.834345219822300 Yarcs: 0.104370216316272 Xmm: -0.500607132911682 Ymm: 0.062622129917145
Jan  8 04:45:05 lbtmu102 LBT_PCS: Centroid Xarcs: -0.928683080373609 Yarcs: 0.026590308741284 Xmm: -0.557209849357605 Ymm: 0.015954185277224
Jan  8 04:45:09 lbtmu102 LBT_PCS: Centroid Xarcs: -0.820813823063453 Yarcs: 0.001108421029907 Xmm: -0.492488294839859 Ymm: 0.000665052619297
Jan  8 04:45:13 lbtmu102 LBT_PCS: Centroid Xarcs: -1.004155276163285 Yarcs: 0.067367448024011 Xmm: -0.602493166923523 Ymm: 0.040420468896627
Jan  8 04:45:18 lbtmu102 LBT_PCS: Centroid Xarcs: -0.946038164757557 Yarcs: 0.061279920115592 Xmm: -0.567622900009155 Ymm: 0.036767952144146
Jan  8 04:45:22 lbtmu102 LBT_PCS: Centroid Xarcs: -0.788844772562127 Yarcs: 0.028410892254934 Xmm: -0.473306864500046 Ymm: 0.017046535387635
Jan  8 04:45:27 lbtmu102 LBT_PCS: Centroid Xarcs: -0.926890073321338 Yarcs: 0.060459294543864 Xmm: -0.556134045124054 Ymm: 0.036275576800108
Jan  8 04:45:31 lbtmu102 LBT_PCS: Centroid Xarcs: -0.821417568443262 Yarcs: 0.060008981453502 Xmm: -0.492850542068481 Ymm: 0.036005388945341
Jan  8 04:45:36 lbtmu102 LBT_PCS: Centroid Xarcs: -0.854952333618578 Yarcs: 0.002993617860409 Xmm: -0.512971401214600 Ymm: 0.001796170719899
Jan  8 04:45:47 lbtmu102 LBT_PCS: Centroid Xarcs: -0.902396637352535 Yarcs: 0.167035894749535 Xmm: -0.541437983512878 Ymm: 0.100221537053585
Jan  8 04:45:50 lbtmu102 LBT_PCS: Centroid Xarcs: -0.932661293039975 Yarcs: -0.003789714141801 Xmm: -0.559596776962280 Ymm: -0.002273828489706
Jan  8 04:45:55 lbtmu102 LBT_PCS: Centroid Xarcs: -0.778015900062436 Yarcs: 0.050088449589846 Xmm: -0.466809540987015 Ymm: 0.030053069815040
Jan  8 04:46:00 lbtmu102 LBT_PCS: Centroid Xarcs: -0.918429690718054 Yarcs: -0.022954650487003 Xmm: -0.551057815551758 Ymm: -0.013772790320218
Jan  8 04:46:04 lbtmu102 LBT_PCS: Centroid Xarcs: -0.884837009696349 Yarcs: 0.128882427748141 Xmm: -0.530902206897736 Ymm: 0.077329456806183
Jan  8 04:46:09 lbtmu102 LBT_PCS: Centroid Xarcs: -0.924792784558107 Yarcs: 0.074911620315521 Xmm: -0.554875671863556 Ymm: 0.044946972280741
Jan  8 04:46:13 lbtmu102 LBT_PCS: Centroid Xarcs: -0.896946388645360 Yarcs: 0.003043460498272 Xmm: -0.538167834281921 Ymm: 0.001826076302677
Jan  8 04:46:18 lbtmu102 LBT_PCS: Centroid Xarcs: -0.836900272256474 Yarcs: 0.155753902774129 Xmm: -0.502140164375305 Ymm: 0.093452341854572
Jan  8 04:46:28 lbtmu102 LBT_PCS: Centroid Xarcs: -0.900843737677145 Yarcs: -0.072216658395655 Xmm: -0.540506243705750 Ymm: -0.043329995125532
Jan  8 04:46:31 lbtmu102 LBT_PCS: Centroid Xarcs: -0.930989382757427 Yarcs: 0.159628701382021 Xmm: -0.558593630790710 Ymm: 0.095777221024036
Jan  8 04:46:36 lbtmu102 LBT_PCS: Centroid Xarcs: -0.854352015505837 Yarcs: -0.007331536602217 Xmm: -0.512611210346222 Ymm: -0.004398921970278
Jan  8 04:46:41 lbtmu102 LBT_PCS: Centroid Xarcs: -0.842510758116695 Yarcs: 0.099759716337650 Xmm: -0.505506455898285 Ymm: 0.059855829924345
Jan  8 04:46:45 lbtmu102 LBT_PCS: Centroid Xarcs: -0.827218342131541 Yarcs: -0.008702526472191 Xmm: -0.496331006288528 Ymm: -0.005221515893936
Jan  8 04:46:50 lbtmu102 LBT_PCS: Centroid Xarcs: -0.959645905132098 Yarcs: 0.170046003810375 Xmm: -0.575787544250488 Ymm: 0.102027602493763
Jan  8 04:46:54 lbtmu102 LBT_PCS: Centroid Xarcs: -0.960635441574432 Yarcs: -0.003861093032081 Xmm: -0.576381266117096 Ymm: -0.002316655823961
Jan  8 04:46:59 lbtmu102 LBT_PCS: Centroid Xarcs: -0.780389357012564 Yarcs: 0.086057179742840 Xmm: -0.468233615159988 Ymm: 0.051634307950735
Jan  8 04:47:09 lbtmu102 LBT_PCS: Centroid Xarcs: -0.850085018336120 Yarcs: 0.063357371708023 Xmm: -0.510051012039185 Ymm: 0.038014423102140
Jan  8 04:47:13 lbtmu102 LBT_PCS: Centroid Xarcs: -0.907993513485559 Yarcs: 0.108202434856138 Xmm: -0.544796109199524 Ymm: 0.064921461045742
Jan  8 04:47:17 lbtmu102 LBT_PCS: Centroid Xarcs: -0.821627029098684 Yarcs: -0.023118870596251 Xmm: -0.492976218461990 Ymm: -0.013871322385967
Jan  8 04:47:22 lbtmu102 LBT_PCS: Centroid Xarcs: -0.906236467902229 Yarcs: 0.093277618099255 Xmm: -0.543741881847382 Ymm: 0.055966570973396
Jan  8 04:47:26 lbtmu102 LBT_PCS: Centroid Xarcs: -0.802029071606938 Yarcs: 0.175269171239052 Xmm: -0.481217443943024 Ymm: 0.105161502957344
Jan  8 04:47:31 lbtmu102 LBT_PCS: Centroid Xarcs: -0.887744921626876 Yarcs: 0.010109181340089 Xmm: -0.532646954059601 Ymm: 0.006065508816391
Jan  8 04:47:36 lbtmu102 LBT_PCS: Centroid Xarcs: -1.025785503685052 Yarcs: 0.144086653694475 Xmm: -0.615471303462982 Ymm: 0.086451992392540
Jan  8 04:47:41 lbtmu102 LBT_PCS: Centroid Xarcs: -0.775296736173314 Yarcs: -0.071628012859158 Xmm: -0.465178042650223 Ymm: -0.042976807802916
Jan  8 04:47:51 lbtmu102 LBT_PCS: Centroid Xarcs: -0.916481910271831 Yarcs: 0.182406069960694 Xmm: -0.549889147281647 Ymm: 0.109443642199039
Jan  8 04:47:54 lbtmu102 LBT_PCS: Centroid Xarcs: -0.816570518739987 Yarcs: 0.007812923270218 Xmm: -0.489942312240601 Ymm: 0.004687753971666
Jan  8 04:47:59 lbtmu102 LBT_PCS: Centroid Xarcs: -0.929476120170732 Yarcs: 0.082010968111030 Xmm: -0.557685673236847 Ymm: 0.049206580966711

After the 5 minutes and before the stepFocus 0.0: (numbers corrected by JMH later)
WFS reporting for image 000170: Z4 +813 Z5 -150 Z6 -136 Z7 -53 Z8 19 Z11 11
After the stepFocus 0.0, sent at or just after 04:48:49, WFS reporting:
WFS reporting for image 000171: Z4 -660 Z5 -147 Z6 20 Z7 41 Z8 -42 Z11 20

Jan  8 04:40:25 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 -896.91 0 0 -31.3631 -5.36278 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Jan  8 04:41:12 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 -158.183 277.139 -5.83515 -1.03773 -27.551 88.899 47.9426 -15.5078 0 0 0 0 0 0 0 0 0 0 0
Jan  8 04:42:00 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 -80.4402 34.2439 -25.7904 -33.2528 -1.08585 3.86471 -72.332 -7.96027 -0 -0 -0 0 0 -0 -0 -0 0 -0 -5.79432
Jan  8 04:42:51 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 -69.5145 5.79086 -42.8335 44.0646 -20.8311 47.9649 85.9756 -8.82376 -0 -0 -0 -0 0 0 0 -0 0 -0 -5.86624
Jan  8 04:48:51 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 813.318 0 0 -53.1752 19.1604 0 0 0 0 0 0 0 0 0 0 0 0 0 0

wfscimage 183 = 1028 nm rms
stepfocus sent at or just after 04:59:03

Jan  8 04:59:05 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 -116.431 408.516 662.05 -119.1 197.931 -61.6585 20.1345 -3.95988 0 0 0 0 0 0 0 0 0 0 0

Guiding failed again somewhere in here.
1216.25 nm rms after focus, but we were running open loop.

Resending the preset, failed with same problem:
Jan 8 05:03:14 lbtmu107 LBT_left_GCS: star verification failed.
Jan 8 05:03:14 lbtmu107 LBT_left_GCS: guide thread stopped.

Error seems to occur right after the first offset from the acquisition image or the first guide image after that. We see one image come up on GCSGUI just before this problem occurs and GCSA stops getting images. See IT# 1942

Try again after recollimating:
wfscimage000190 last WFS file before stopping updates at 5:12 rms=180
wfscimage000198 last before sending stepfocus, 892nm rms +700nm Z4
wfscimage000199 right after stepfocus. -600nm Z4 = over-corrected

  • it appears we are still applying the corrections twice.

Jan  8 05:08:33 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 -427.198 -481.045 -546.324 206 -140.17 -50.1847 -93.9366 8.59217 0 0 0 0 0 0 0 0 0 0 0
Jan  8 05:09:45 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 -418.619 -9.52796 -138.91 114.719 -46.152 36.5547 9.55675 27.0783 0 0 0 0 0 0 0 0 0 0 0
Jan  8 05:10:35 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 -69.3839 35.1252 136.274 34.0157 29.5213 -3.99619 24.5669 -10.9037 -0 -0 0 0 0 -0 0 -0 -0 -0 1.72211
Jan  8 05:11:24 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 -117.519 18.0154 -63.0497 -5.39574 32.8146 10.5077 -30.7687 12.1868 -0 -0 0 0 0 -0 -0 -0 -0 -0 -2.48703
Jan  8 05:12:16 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 -60.3174 -57.6651 36.5233 -9.49629 -34.0467 -18.156 -16.048 -11.0977 -0 -0 0 0 0 -0 -0 0 -0 -0 9.19697
Jan  8 05:18:28 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 706.676 51.5646 -22.3993 -42.804 62.8822 13.6761 7.18717 4.19919 0 0 0 0 0 0 0 0 0 0 0
Jan  8 05:23:54 lbtmu107 LBT_PSFL: ACTOPT: Primary Zernikes 0 0 0 10.5777 20.8342 0 0 -20.8668 22.8017 0.617355 -0 -0 0 0 0 -0 0 -0 0 -0 -24.6859

After the step focus, we continue to have the focus drift up, back through zero.

* Test 3a*

3a) Set the Z11 and Z22 gains in PSF to 0. This will eliminate the small focus corrections that trigger the updates. But you probably don't want to run like this for more than an hour or so without a Z11 correction. The gains are changed by sending a manual correction of Z11 with the PSF Primary GUI. The manual corrections also allow changes of GAIN and FCIN along with the Zernike amplitude.

Gains on Z11 and Z22 set to zero.

Total M1 collimation: X=-1.589 Y=-0.834 Z=0.0691 RX=-39.565 RY=27.012

05:27:22 GCS stopped guiding again. Stop and restart only GCS, resend preset

IE changed to 98, CA to 45.

05:38 Total M1 collimation: X=-1.473 Y=-0.835 Z=0.774 RX=-38.633 RY=26.293

Seeing elongated images in the guider on-axis when the aberrations reported by WFS are low. Ran through focus a couple times and orientation does not change, so it is not astigmatism and probably vibrations we are seeing.

M1 total collimation did not change through several iterations of the WFS and EL is changing rapidly (setting straight west).

3a demonstrated that by setting the Z11/Z22 gains to zero, we could collimate everything else and not move the primary (all sent to secondary).

Test 3b

Jan 8 05:53:37 lbtmu107 LBT_left_GCS: error requesting an image in Guiding Thread. Lost connection?

06:00 Try again. We are collimated. Setting FCINs to 1 and gains to 1. We do not seem to be sending Z22 corrections, although Andrew thinks we should be.
Max on total force plot is +/-20 Total collimation Z=0.930 mm

Jan 8 06:01:40 lbtmu107 LBT_left_GCS: error requesting an image in Guiding Thread. Lost connection?

Total collimation Z=0.957 Max on total force plot has grown to +/-25 after a couple of iterations

Jan 8 06:07:05 lbtmu107 LBT_left_GCS: error: GuidingThread: guide image didn't arrive within timeout of 2888 ms.
Jan 8 06:07:07 lbtmu107 LBT_left_GCS: IST: error when receiving image

06:12 Total collimation Z=1.019 Max on total force plot has grown to +/-25 after a couple of iterations

06:16 Total collimation Z=1.019 Max on total force plot has grown to +/-30 after several more iterations

3b Under tonight's conditions you do not build up bending forces too rapidly.

3c) New in PSF 4.26 - Chris has installed a flag in lbt.conf

Cannot do test 3c - cannot edit the lbt.conf file in /lbt/tcs/17/etc/ unless you are root

Jan 8 06:27:33 lbtmu107 LBT_left_GCS: error: GuidingThread: guide image didn't arrive within timeout of 2989 ms.

New AGw focus position for LUCIFER is 27.586. Applying +600nm Z4 to M2 (eyeball estimate from earlier LUCIFER images)
Fit to the data would suggest 313nm = 1.956 mm (should be 31.586 - 1.956 = 29.630 mm for the nominal focus)

Closed just before 7:00am

Advanced Planning:

Explicit Build17 TCS checkout tests, closed dome:
  • GCS-AGw oacserver transforms?

Execute TCS startup checklist (complete @ sunset - 1hr):
  • Include mount encoder resets each night.
  • New collimation model = clear all active/global offsets
  • At end of startup, issue a standard preset:

Startup pointing & collimation correction (10 minutes):
  • Use source list: Persson.cat
  • Select target at mid EL (50-70 degrees)
  • Preset in PARALLACTIC/TRACK mode
  • Adjust IE and CA; manually focus if necessary
  • Preset in POSITION/ACTIVE mode on axis
  • Allow system to collimate (WFS<400nm rms)

Explicit Build17 TCS checkout tests, open dome:

MCS pre-processor algorithm verification (30 minutes):
  • Use source list: Persson.cat
  • Select target at mid EL (50-70 degrees)
    1. Preset ACTIVE mode on-axis to collimate
    2. Preset PARALLACTIC/TRACK mode to align DETXY to AZ/EL
    3. Start sequence with LUCIFER 120x1.0sec
    4. Do the following during the sequence acquisition:
      • Offset 20 arcsec each in XY or NE
      • Repeat steps 2-4 with larger offsets (60, 120, 240, 600 arcsec)
      • Repeat from step 1 as needed for collimation drifts
  • Note if dawdle-snap behavior remains
  • Data:
    LUCI# Observation Description
       
       
       
  • Results:

Verify collimation updates not double-applied:
  • Run WFS collimation for 5 min with PSF collimation updates held
  • send stepFocus 0.0
  • should see resulting image in good focus/collimation
  • May not need to do this if no problems seen in dawdle-snap test

Additional information from JHill:

3a) Set the Z11 and Z22 gains in PSF to 0. This will eliminate the small focus corrections that trigger the updates. But you probably don't want to run like this for more than an hour or so without a Z11 correction. The gains are changed by sending a manual correction of Z11 with the PSF Primary GUI. The manual corrections also allow changes of GAIN and FCIN along with the Zernike amplitude.

3b) Set the FCIN flags Z11 and Z22 to 1. This causes the focus correction to be implemented by bending the mirror rather than by repositioning. In stable conditions using it this way will be no problem, and you will get continuous Z11 and Z22 corrections. However, in conditions with rapidly changing mirror temperatures there is a problem that the mirror will run out of its allowed range of correction forces and panic. Bending in the focus uses more force than getting focus by moving the mirror.

3c) New in PSF 4.26 - Chris has installed a flag in lbt.conf that suppresses the focus correction for Z11 and Z22 corrections to M1. Setting leftZ4Comp to false will eliminate the focus part of the correction and apply only the minimum bending forces for Z11/Z22 to the mirror. This relies on the corrections from minute to minute being small so that the next active iteration will correct the residual focus error. We have not yet tested this on sky. This avoids the pitfalls of 3a and 3b above. It has the new pitfall that there could be a lag in the corresponding focus correction. I suggest running it in combination with Z11 and Z22 gains of 0.2 so that the corrections are applied slowly and therefore create only small focus changes.

If testing time on sky is limited. I suggest that we jump immediately to mode 3c with Z11/Z22 gains of 0.2. This is likely to be the new standard LUCIFER observing mode for spectroscopy if primary mirror jumps remain a problem.

Verify isCollimated Flag functionality:
  • Watch isCollimated flag in DDViewer
  • Should go to FALSE on all presets/offsets

Verify Functionality of Hold Zernike Corrections until Stepfocus
Is this the "Hold WFS Corrections" test? It is, and this is done

Verify Preset completes after Gstar on WFS (DONE 02Jan09, GCSv2.01):

Focus LUCIFER/AGW on sky (30-45 minutes/field):
  • Prerequisite: Stable atmospheric seeing
  • Use source list: Persson.cat, LUCIastrom.cat?
  • Select target at mid EL (50-70 degrees)
  • In an xterm: ssh agwuser@agw-control
  • Preset in ACTIVE mode using off axis guide star
    1. Offset, take sky frame, return to preset position
    2. Offset AGW focus stage (0, -6, 6, 0, -3, 3, 0 mm from nominal).
      To set the AGw focus position, on agw-control window type:
      1. getfocus
      2. setfocus -p NN.nnn (absolute position in mm)
    3. Take min 30s exposure to average over seeing
    4. Repeat steps 2-3 stepping through focus sequence
    5. Derive best focus position (millimeters)
    6. Update focus in /lbt/tcs/current/etc/GCS/AIP_L.cfg
  • Repeat for at least 3 different stars at different ELs
  • Data:
    LUCI# FocusSorted ascending FWHM
         
         
         
  • Results:

Active Optics Jump Tests (2hr)
  1. Start with a faint guide source at around 80 degrees. In closed loop (active optics + guiding) demonstrate the jumps. The guide source should be selected so that 5 second exposures are possible without saturating the detector. (15 minutes ACTIVE mode)

  1. Open both the guiding and active optics control loops. GCS must still report centroid positions. This data will serve as an open-loop baseline observation. GCS centroid data should be collected for 15 minutes (around 150 GCS updates). (ACTIVE mode, stop WFS, block guiding)

  1. See next test. Take 5 minute data (2 sec LUCIFER images) in GUIDE mode

Verification of Guiding Performance:
  • Take 5 min data (2 sec LUCIFER exposures) in GUIDE mode
  • Compare with the ACTIVE mode

Measure/Correct LUCIFER rotation angle (15-30 minutes/field):
  • Use source list: LUCIastrom.cat (any field with lots of stars in USNO-B1)
  • Preset to field, ACTIVE mode with off-axis guide stars
  • Take min 30sec exposure to average over seeing
  • Offset and take a sky exposure, same settings
  • Apply astrometric solution, determine rotator offset
  • Update LEFTZEROPOINT in the LUCIFER section of /home/telescope/TCS/Configuration/PCS/PCSInstrument.conf
  • Repeat on at least 3 fields (more=better), different elevations
  • Goal: Orientation better than +/-0.02 degrees
  • Data:
    LUCI# Field/Description PA(requested) PA(WCSfit)
           
           
           
  • Results:

Measure AGW Z-axis orthogonality (20min per cycle):
  • Needs telescope in thermal equilibrium, decent stable seeing
  • Correct pointing (IE/CA) prior to this test
  • Use source list: Persson.cat, collim.cat
  • Select target at mid EL (50-70 degrees)
  • In an xterm: ssh agwuser@agw-control
  • Preset in ACTIVE/ mode, on axis, PA=0
    1. Collimate on axis
    2. Stop WFS, stop guiding
    3. Take 10x 2sec images with guider
    4. Offset AGW focus stage -5 (+5) mm from nominal.
      To set the AGw focus position, on agw-control window type:
      1. getfocus
      2. setfocus -p NN.nnn (absolute position in mm)
    5. Take 10x 2sec images with guider
    6. Repeat steps 3-4 at other focus position
  • Repeat from preset several times
  • If position offset is seen, repeat at PA=+/-90
  • Data:
    LUCI# Centroid Notes
         
         
         
  • Results:

Re-Measure AGW-PCS Transformation (2hr per field):
  • Prerequisites:
    LUCIFER accurately oriented on sky
    (PA=0 requested yields PA=0.00+/-0.02 achieved)
  • Use source list: Persson.cat (9122, 9126, 9134, 9143)
  • New finding charts attached to wiki page for 02-03 Jan:
    http://wiki.lbto.arizona.edu/twiki/bin/view/Commissioning/Com20090103
  • Use on-axis source with off-axis guide star that can be dithered 2+ arcmin in DET_Y
    1. Take min 30s integrations at each position
    2. Measure angular offset (0.02 deg = 0.35 pixels/1000)
    3. Update SFP_rotation in /lbt/tcs/current/etc/GCS/AIP_L.cfg
    4. Repeat steps 1-2 to confirm sign is correct
  • Repeat on 3 fields, different EL

Field Aberration Stability Test (1 hr):
  • ARakich
  • 4-8 Stars
  • Needs telescope in thermal equilibrium

Update Collimation Model (2+ hrs data collection, plus processing time):
  • PROBABLY NOT NEEDED, JUST VERIFY MULTI-NIGHT COLLIMATION MODEL FROM DEC
  • Prerequisites:
    TELESCOPE IN THERMAL EQUILIBRIUM!
    DECENT SEEING (less than 1.25 arcsec FWHM on guider)
  • Confirm needed mirror positions, temps in LUCIFER headers
  • Use source list: collim.cat
  • Observe sources: 25(15) < EL < 87 if possible
    1. Preset in ACTIVE mode, on-axis
    2. Allow system to collimate: WFS<400nm rms
    3. Take 2s exposure with LUCIFER to record mirror information
    4. Repeat steps 1-3 as needed to cover EL-space
  • Observe minimum 1 full cycle through EL range, 12 sources,
    Prefer two cycles, 20+ sources.
  • Generate new collimation model (J.Hill?)
  • Implement new collimation model
  • Data:
    # LUCI# UT EL   # LUCI# UT EL
    01       * 02      
    03       * 04      
    05       * 06      
    07       * 08      
    09       * 10      
    11       * 12      
    13       * 14      
    15       * 16      
    17       * 18      
    19       * 20      
  • Results:

Update Pointing Model (2-4 hours data collection, plus processing time):
  • Prerequisites:
    TELESCOPE IN THERMAL EQUILIBRIUM!
    Using new collimation model from previous step
    Verify with LUCIFER Team that internal flexures are corrected
    Re-measure mechanical rotator center coords on LUCIFER
    • Take pair of TRACK mode images rotated 180 degrees apart
    • New rotator center: X Y
  • Update pointing and collimation prior to start, mid EL (50-70 degrees)
  • Use source list: Allstars10.cat, updated to include PA=0 in list
  • Turn on pointing log in PCS GUI
    Filename = ____________________
  • Use /home/LBTO/POINTING/Pointingstars5 to schedule
    1. In your working directory on an observer workstation:
      cp ~LBTO/POINTING/* . to copy program files
    2. Type ./Pointingstars5 at linux prompt to run program
    3. Enter the sequential reference field number [1-88]
    4. Preset to the source listed, TRACK mode, take 30s exposure.
    5. Repeat steps 2-4 for at least 24 points, 48+ would be better.
  • Stop pointing log in PCS GUI
  • Generate new pointing model (D.Thompson)
  • Implement:
    • Copy to ~telescope/TCS/Configuration/PCS/
    • Update LUCIFER entry for LEFTPOINTINGMODEL
      in PCSInstrument.conf
    • Re-authorize LUCIFER on IIF GUI to read in new pointing model
  • Test new pointing model
  • Data:
    # LUCI# Star ID   # LUCI# Star ID   # LUCI# Star ID
    01     * 02     * 03    
    04     * 05     * 06    
    07     * 08     * 09    
    10     * 11     * 12    
    13     * 14     * 15    
    16     * 17     * 18    
    19     * 20     * 21    
    22     * 23     * 24    
    25     * 26     * 27    
    28     * 29     * 30    
    31     * 32     * 33    
    34     * 35     * 36    
    37     * 38     * 39    
    40     * 41     * 42    
    43     * 44     * 45    
    46     * 47     * 48    
    49     * 50     * 51    
    52     * 53     * 54    
    55     * 56     * 57    
    58     * 59     * 60    
    61     * 62     * 63    
    64     * 65     * 66    
    67     * 68     * 69    
    70     * 71     * 72    
    73     * 74     * 75    
    76     * 77     * 78    
    79     * 80     * 81    
    82     * 83     * 84    
    85     * 86     * 87    
    88     * 89     * 90    
  • Results:

-- DavidThompson - 07 Jan 2009

This topic: Commissioning > Main > WebHome > Com20090108
Topic revision: 16 Jan 2009, JohnHill
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback