4-5 January 2009

Observers: Doug Miller, Joar Brynnel (Tucson)
Telescope Operator: J.Rousseau (mtn)

Summary

Closed dome testing

Details

All times are from lbtmu107

Wind average 13 m/sec @ 350 degrees, gusting to 22 m/sec Temp outside -5C, Humidity 100%, PMC temperature +2C

21:30:00 All systems up and running, telescope and rotator tracking. Mirror ventilation off due to humidity.

21:31:51 Collimated SX

21:36:03 Sent preset command (from IRAF as Lucifer) to M5_0042 track mode - success

El 50 Az 288

Local Time nanometers Zernike Surface Comment
21:43:40 +2000 Z4 M1  
21:45:43 -2000 Z4 M1  
21:47:14 +1000 Z5 M1  
21:47:42 -1000 Z5 M1  
21:48:40 +1000 Z11 M1  
21:49:15 -1000 Z11 M1  
21:50:02 +500 Z22 M1 Takes 25 seconds to complete
21:51:05 Collimated M1  
21:52:33 -500 Z22 M1 Took 15 seconds
21:53:54 +1000 Z4 M2  
21:54:25 -1000 Z4 M2  
21:57:50 +1000 Z5 M2 (ignored)
21:58:30 -1000 Z5 M2 (ignored)
21:59:04 +1000 Z11 M2 (ignored)
22:00:10 -1000 Z11 M2 (ignored)
22:02:20 +1000 Z7 M2  
22:03:06 -1000 Z7 M2  
22:03:39 +1000 Z8 M2  
22:04:13 -1000 Z8 M2  
22:06:20 +1000 Z7 M1  
22:06:57 -1000 Z7 M1  
22:07:41 +1000 Z8 M1  
22:08:24 -1000 Z8 M1  
22:08:54 Collimate M1  
22:12:05 +500 Z22 M1 Test time to apply Z22
22:12:23   M1 Actuator start moving
22:12:28   M1 Request complete
22:16:19 -500 Z22 M1  
22:16:35   M1 Actuator start moving
22:16:39   M1 Request complete

End Az,El 290,42

22:28 pointto M5_0202 TelMode="TRACK"

Start Az,El 141,84

Local Time nanometers Zernike Surface
22:38:16 +1000 Z4 M1
22:38:54 -1000 Z4 M1
22:39:32 +1000 Z5 M1
22:40:02 -1000 Z5 M1
22:40:33 +1000 Z7 M1
22:40:59 -1000 Z7 M1
22:41:26 +1000 Z8 M1
22:42:05 -1000 Z8 M1
22:42:43 +1000 Z4 M2
22:43:15 -1000 Z4 M2
22:43:47 +1000 Z7 M2
22:44:14 -1000 Z7 M2
22:44:56 +1000 Z8 M2
22:45:21 -1000 Z8 M2
22:45:56 Collimate M1
22:48:38 LFBG Rotator to Position Mode
22:51:00 LFBG Rotator to Track Mode

End Az,El = 196,85

22:53 pointto M5_0170 TelMode="TRACK"

Start Az,El = 193,25

Local Time nanometers Zernike Surface
22:55:10 +1000 Z4 M1
22:55:49 -1000 Z4 M1
22:56:45 +1000 Z5 M1
22:57:31 -1000 Z5 M1
22:59:05 +1000 Z7 M1
23:00:07 -1000 Z7 M1
23:01:02 +1000 Z8 M1
23:01:48 -1000 Z8 M1
23:02:49 +1000 Z4 M2
23:03:22 -1000 Z4 M2
23:04:22 +1000 Z7 M2
23:05:04 -1000 Z7 M2
23:05:53 +1000 Z8 M2
23:06:19 -1000 Z8 M2
23:06:49 Collimate M1
23:09:36 LFBG Rotator to Position Mode
23:12:19 LFBG Rotator to Track Mode

End Az,El = 198,23

Tracking at several positions on the sky

Local Time Object Az El
23:35:35 M50325 136 33
23:41:50 M50384 84 38
23:48:44 M50387 28 42
23:53:55 M50314 56 66
23:59:58 M50328 89 62
00:07:04 M50269 159 77
00:16:40 M50202 263 70
00:27:04 M50193 309 65
00:31:30 M50182 332 55
00:37:03 M50094 284 32
00:44:18 M50151 250 36
01:00:04 M50149 236 21

**Note, the last two presets seem to take a very long time. The Mount and rotators were tracking after about 1 minute, but another 2-3 minutes passed before the IIF returned sucessful. Everything seemed to be fine with the preset, just really slow. In fact, the preset to M50149 was send at 00:49 and did not return. The preset with aborted at 01:00:04 (IIF Gui) and still did not return. Jon parked the telescope and shutdown.

Wind ~ 10-16 m/s

Temp ~ -5C

-- JoarBrynnel - 05 Jan 2009