--++ Commissioning Notes from 20th-21th June 2008 MST

Observers: D. Miller, A. Rakich (in Tucson), J. Storm (at LBTO).
OSA: A. Ceranski

Summary

Night time Activities

(Times are in MST)

8:15 pointto BS9166 Collimate

8:45 Test that triggerWFS gets image and calculates zernikes through the GCS. Success! If we use the stand alone routine wfsc_image (IDL call) to get a WFSC image then the GSC will have socket problem and fail to acquire WFSC image.

9:00 Collimate on BS9166 then move to off-axis star to measure focus: Z4 = ~1300, Move stage to 5 mm to correct. Wait!! Elevation is changing quickly. Must re-collimate primary by hand. Chasing elevation focus correction. Move to star in the south (wfsc images 2-39)

9:50 pointto BS9164. Collimate (40-46)

10:09 pointto BS9164 gstar = 14 x= -0.5 y = 493 wfsc 47-51 z4 = 782, 909, 845, 899, 875 z4_ave =862

10:15 back to on-axis collimate wfsc 52-54 z4 = 263, 281, 67

10:18 back to gstar = 14. delta_focus = 862/164=5.3 mm setfocus -p 15.7 wfsc 55-58, z4 = 247, 234, 626

10:22 gstar = 14. delta_focus =10 mm setfocus -p 11 wfsc 59-61, z4 = -140, -282, -229

10:26 gstar = 14. delta_focus =7.5 mm setfocus -p 13.5 wfsc 62-64, z4 = 89, 120, 145

10:15 back to on-axis, no collimation wfsc 65-67 z4 = 337, 343, 273

10:30 Jesper's Data

Tried to insert M92 in iraf/IRTC/Catalogs/LBTDefault.cat but iraf did not see the new entry. Even tried restarting iraf.

[The default version of LBTtools is the one in Dave T's directory. You have to explicitly set the path to the package if you want to use a local version belonging to LBTO. JMH 08-July-2008]

M92 Field Stars

All data in /Repository/AGW_Data/080621g

[JMH: The first of these guider images are 10 pixels FWHM.]

Rotator Angle Guider Image
350 1-10
318 11-20
290 21-30
260 31-33
230 34-36
200 37-39
170 40-42
140 43-45
110 46-48
80 49-51
50 52-54
20 55-57
20-270 58
270 59-61

Jupiter Images

Data in /Repository/20080621_IRTC/

jupiter_000??_cube.fit Type Exp Time (microsec) flat subtracted (on tuco.as)
31 H 10000  
32 H 20000  
33 H 40000  
34 H 40000  
35 H 20000  
36 H 20000  
37 H 40000  
38 H 40000  
39 H 20000  
40 H 20000 new40.fits
41 H 40000  
42 H 40000  
43 H 20000 new43.fits
44 H 20000  
45 H 40000  
46 H 40000  
47 H 40000  
48 H 20000  
49 H 20000  
50 H 40000  
51 H 40000  
52 H 20000  
flat_000??_cube.fit Type Exp Time (microsec)  
53 flat 20000  
54 flat 40000  
55 flat 10000  

-- DougMiller - 21 Jun 2008

This topic: Commissioning > Main > WebHome > Com20080621
Topic revision: 08 Jul 2008, JohnHill
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.