You are here: Foswiki>Commissioning Web>Com20080617 (18 Jun 2008, AndrewRakich)Edit Attach
--++ Commissioning Notes from 16th-17th June 2008 MST

Observers: D. Miller, A. Rakich (in Tucson).
OSA: A. Ceranski

Summary

Night time Activities

(Times are in MST)

8:15 Open dome, pointto BS9166; Guide failed, didn't find star

8:20 pointto: Failed GCS freeze while starting (see below)

Jun 16 20:25:34 lbtmu107 LBT_left_GCS: error: setProbePosition: couldn't move probe to position (SFP) (x,y): -0.173676, 0.099340 mm.
Jun 16 20:25:34 lbtmu107 LBT_left_GCS: GCSL:setGuidestarList execution time: 30631 ms at 1213673134195
Jun 16 20:25:48 lbtmu107 LBT_left_GCS: GCSL:stopGuiding executed
Jun 16 20:25:48 lbtmu107 LBT_left_GCS: GCSL:stopGuiding execution time: 15 ms at 1213673148394
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: GCSL:setGuidestarList executed
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: GuideStar set to RA/DEC: 4.3265, 0.526159
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: PROFILING: moveProbeOnGuideStar entered.
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: selectAGW(AIP_LUCIFER):
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: didn't create a new instance of AGWUnitAIP as the types are the same
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: selecting AGW unit AIP_LUCIFER and intializing it with /lbt/tcs/current/etc/../etc/GCS//AIP_L.cfg
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: initalizing AIP AGW unit from pathname '/lbt/tcs/current/etc/../etc/GCS//AIP_L.cfg'
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: readfile: 0
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: reading Configuration for AIP_LUCIFER:L from: /lbt/tcs/current/etc/../etc/GCS//AIP_L.cfg
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: name = AIPAGW3
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: WFS_size = 13
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: oacontrol_IP = 10.144.0.64
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: focus = 21.000
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: filter_1_name = B
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: filter_1_wl = 440
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: filter_2_name = V
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: filter_2_wl = 520
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: filter_3_name = r'
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: filter_3_wl = 630
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: filter_4_name = empty
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: filter_4_wl = 0
Jun 16 20:25:49 lbtmu107 LBT_left_GCS: filter_5_name = empty
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: filter_5_wl = 0
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: AGWUnit initialized, calling init() ...
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: _filterPos
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: _probePos
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: _status
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: _statusText
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: _type
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: _autofocusFlag
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: _focus
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: done
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: init() successful, now initializing cameras
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: checking _azcam member
Jun 16 20:25:50 lbtmu107 LBT_left_GCS: deleting _azcam instance
Jun 16 20:26:38 lbtmu107 LBT_left_GCS: [E] AIP AGW unit error: AGW1: RPC Communication Error
Jun 16 20:27:31 lbtmu107 LBT_left_GCS: signal 2 received.
Jun 16 20:27:31 lbtmu107 LBT_left_GCS: GCS Subsystem Shutting Down
Jun 16 20:27:31 lbtmu107 LBT_left_GCS: Waiting for Guiding and WFS Threads to Stop.
Jun 16 20:27:31 lbtmu107 LBT_left_GCS: guide thread stopped.
Jun 16 20:27:31 lbtmu107 LBT_left_GCS: WFS thread stopped.
Jun 16 20:27:31 lbtmu107 LBT_left_GCS: Exiting Main
Jun 16 20:27:39 lbtmu107 LBT_Networkserver: GCSL refused to stop
Jun 16 20:27:47 lbtmu107 LBT_Networkserver: Server 4/4: name lbtmu107, load 15.780000, subsystem count 1 ( GCSL ), has rules true, last update 1213672878881
Jun 16 20:27:47 lbtmu107 LBT_Networkserver: update 1213673267622 lbtmu107 10.144.0.107 10.10.0.107 10.30.0.107 4 13.86 1 GCSL
Jun 16 20:27:55 lbtmu107 LBT_Networkserver: GCSL murdered
Jun 16 20:27:56 lbtmu107 LBT_Networkserver: GCSL died unexpectedly
Jun 16 20:27:56 lbtmu107 LBT_Networkserver: dropping GCSL
Jun 16 20:28:01 lbtmu107 LBT_Networkserver: GCSL has rule to run on lbtmu107
Jun 16 20:28:01 lbtmu107 LBT_Networkserver: GCSL starting on lbtmu107
Jun 16 20:28:01 lbtmu107 LBT_Networkserver: GCSL started
Jun 16 20:28:01 lbtmu107 LBT_Networkserver: Server 4/4: name lbtmu107, load 15.490000, subsystem count 1 ( GCSL ), has rules true, last update 1213673281200
Jun 16 20:28:01 lbtmu107 LBT_Networkserver: update 1213673281426 lbtmu107 10.144.0.107 10.10.0.107 10.30.0.107 4 16.83 1 GCSL
Jun 16 20:28:04 lbtmu107 LBT_left_GCS: GCS Version 1.9.7
Jun 16 20:28:04 lbtmu107 LBT_left_GCS: Compile time flags are:
Jun 16 20:28:04 lbtmu107 LBT_left_GCS: GCS_TESTING
Jun 16 20:28:04 lbtmu107 LBT_left_GCS: VERBOSE
Jun 16 20:28:04 lbtmu107 LBT_left_GCS:
Jun 16 20:28:04 lbtmu107 LBT_left_GCS: GCS constructor called.
Jun 16 20:28:04 lbtmu107 LBT_left_GCS: setting state...
Jun 16 20:28:04 lbtmu107 LBT_left_GCS: state set.
Jun 16 20:28:04 lbtmu107 LBT_left_GCS: triggering event...
Jun 16 20:28:04 lbtmu107 LBT_left_GCS: event triggered.
Jun 16 20:28:04 lbtmu107 LBT_left_GCS: guide rate changed to 0.400000 Hz, interval of 2.500000 seconds
Jun 16 20:28:04 lbtmu107 LBT_left_GCS: GCS constructor finished.
Jun 16 20:28:04 lbtmu107 LBT_left_GCS: registering commands ...
Jun 16 20:28:11 lbtmu107 LBT_left_GCS: Registration complete
Jun 16 20:28:11 lbtmu107 LBT_left_GCS: starting GCS thread...
Jun 16 20:28:11 lbtmu107 LBT_left_GCS: GCS Subsystem Thread Started

8:24 pointto and guide on-axis

8:25-8:50 collimate wfsc 2-8

8:51 pointto BS9166, gstar=18 Failed, guide star off chip

8:55 move IE anc CA. Guide. Rotangle = -158

8:59 BS9166, gstar=17: Failed, GCS did not receive guide command. Killed GCS and restarted. Not correct angle

9:05 BS9166, gstar=8: failed, star on chip, but did not find it properly

9:10-9:50 setup off-axis Ry, Rx values

9:57 -10:03 Guide on-axis, Collimate 18-24

10:14 collimate button, then make 3 measuremnts of tip +72 off star #8, wfsc 27-29

10:15 collimate button, then make 3 measurements of tip+36 wfsc 31-33

10:17 going to daughter star with zero offset, press collimate button, take 3 measurements of tip = 0 tilt = 0, wfsc 35-37

10:21 going to -36 tip , press collimate button, wfsc 39-40 lost guiding, reacquiring

10:30 going to -72 tip, press collimate button, wfsc 43-45

10:44 tilt +36, press collimate, wfsc 47-49

10:55 tilt -36 press collimate wfsc 52-53

11:05 going to star #8 taking data but rotator changing so quickly that we have no useful information. Hand telescope over to Tom for ~30 min utes

12:53 Start again, a little wiser..., recollimating with Act optics on-axis BS9166 wfsc 63-65

12:57 going to #8, taking 3 WFSC images WFSC 67-69

1:10 going to -60 tip WFSC 71-73

1:14 tip +60 wfsc 75-77

1:16 tilt -60 wfsc 79-81

1:23 back to #8 no offset wfsc 83-85

1:28 tilt +60, wfsc 87-89

1:34 tip -30, wfsc 94-96

1:50 #8 no offsets , wfsc 98-100

2:01 tip +30, wfsc 102-103, 105

2:06 tilt -30, wfsc 107-109

2:11 tilt +30, wfsc 111-113

2:18 go to #8 no offsets, wfsc 115-117

2:22 on-axis wfs 119-121

2:45 gone to M5_0738, taking images for curvature sensing

3:40 gone to M5_1539. Gstar=1 is 12th mag

3:50-4:00 collimate 080617w/m5_1539/ 2-8

4:01 Collimated off-axis x=-0.24 y=502.5

4:02 Change focus on Primary by -1000 for better IRTC focus. Measure -1036 on WFSC (12) -880 (14)

4:07 Change stage position to 25 from 21. measure -628, -629 (15,16)

4:13 Change stage to position 29 measure 483 and 451 (18,19)

4:18 Change stage to position 26 measure -299 and -523 (20,21)

4:22 Change stage to position 28 measure

rot angle = 72

+-10000 nm focus m5_1539_ex0001 and m5_1539_in0002

+1000 nm z5 m5_1539_ex0004 and m5_1539_in0003

+1000 nm z7 m5_1539_ex0006 and m5_1539_ex0007 (0005 exp too long)

+1000 nm z9 m5_1539_ex0009 and m5_1539_ex0008 (100 images)

+1000 nm z9 m5_1539_ex0010 and m5_1539_ex0011 (300 images)

+500 nm z11 m5_1539_ex0013 and m5_1539_ex0012 (300 images)

m5_1539_ex0014 garbage

rot angle = 79

-- DougMiller - 17 Jun 2008
Topic revision: r6 - 18 Jun 2008, AndrewRakich
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.