Commissioning Notes from 18-19 May 2008 MST

Observers: Doug M on mountain and Andrew R in Tucson.

T.O.: Randy G.

Summary

Rotated WFS by the correct amount, verified improved closed loop performance. Showed convergence from 4000 nm of applied Z7 in two iterations, 6000 nm of applied Z4 in several iterations, mixed modes giving ~ 2000nm aberration in several iterations. Seems to work pretty well, converges to ~+/- 50 nm on z4-z11, and this in seeing ranging from 1.5"-2.5". Also we can see a way to improve on this without too much more effort.

Went off-axis and verified that the focus off-set calculated (between off-axis star and IRTC, from field curvature) is approximately correct, and that the pupil shift on the WFSC with field angle is approximately as calculated (~+/-10% of where it should be).

Started to determine orientation of y-axis of AGW stage in PM coordinates when we were stopped by bad weather and multiple GCS failures.

Nighttime Activities

1:00 Kevin and Randy swap out bad card in Elevation power supply. All seem to be working now.

2:20 Send pointto "WT10_311" to telescope and we slew

2:25 We see a star on the IRTC

2:30 Close guiding loop on this bright star

2:40 pointto "BS9153"

3:05 Randy reopens issuetrak 1236 HBS failure, working again now

3:20 seeing 1.5" humidity 36% temp 10C, wind zero, star was way out of focus, applied 3 microns of Z4 to global offset

3:33 acquired star on guider, took two images in 080518w directory (wfsc000114-5), now changing directory to 080519w and starting again... images from wfsc00002-12 good convergance, sorted out coefficients on z9, z10

3:52 taking through focus images, trying first on guide camera guider 06 was 1sec exposure, guider 07 was 5 sec exposure. defocussing guide camera, didn't work, defocussing with M1

4:07 guider 12 was 6000 nm Z4, guider13 12000nm z4 guider14 will be 18000nm 40s exposure

4:10 guider 16 -6000 nm Z4, 20s exp, guider 17 -12000 z4 , 20s exp, guider 18 -18000 40s exp, guider 19 in-focus 2 s exp, all guider images are in \Repository\AGW_Data\080519g

4:17 going back to focus, re-acquiring guiding and running ActO for a few iterations to clean up image prior to through focus images on IRTC

4:23 GCS hung (see below) Randy killed GCS at 21:24:20

May 18 21:21:07 lbtmu107 LBT_left_GCS: init() successful, now initializing cameras
May 18 21:21:07 lbtmu107 LBT_left_GCS: checking _azcam member
May 18 21:21:07 lbtmu107 LBT_left_GCS: deleting _azcam instance
May 18 21:21:07 lbtmu107 LBT_left_GCS: ImageServerThread ended
May 18 21:21:07 lbtmu107 LBT_left_GCS: creating _azcam instance
May 18 21:21:07 lbtmu107 LBT_left_GCS: ImageServerThread created. instance = 2
May 18 21:21:07 lbtmu107 LBT_left_GCS: setting up imageserver IP
May 18 21:21:07 lbtmu107 LBT_left_GCS: init and connect ...
May 18 21:21:07 lbtmu107 LBT_left_GCS: checking _azcam member
May 18 21:21:07 lbtmu107 LBT_left_GCS: deleting _azcam instance
May 18 21:21:07 lbtmu107 LBT_left_GCS: ImageServerThread ended
May 18 21:21:07 lbtmu107 LBT_left_GCS: creating _azcam instance
May 18 21:21:07 lbtmu107 LBT_left_GCS: ImageServerThread created. instance = 3
May 18 21:21:07 lbtmu107 LBT_left_GCS: setting up imageserver IP
May 18 21:21:07 lbtmu107 LBT_left_GCS: init and connect ...
May 18 21:21:08 lbtmu107 LBT_left_GCS: reading GuidingThread configuration from '/usr/commonsw/Configuration/GCS//AIP_L.cfg'
May 18 21:21:08 lbtmu107 LBT_left_GCS: reading WFSingThread configuration from '/usr/commonsw/Configuration/GCS//AIP_L.cfg'
May 18 21:21:08 lbtmu107 LBT_left_GCS: setGuidestarList (and conversion):
May 18 21:21:08 lbtmu107 LBT_left_GCS: offset = 0.000000, 612.500000 mm.
May 18 21:21:08 lbtmu107 LBT_left_GCS: RA/DEC = 3.698200, 0.216377
May 18 21:21:08 lbtmu107 LBT_left_GCS: converted into SFP by PCS (x,y) = -0.082329, -0.086407 arcsecs
May 18 21:21:08 lbtmu107 LBT_left_GCS: converted into native AGW coordinates by GCS (x,y) = -0.082329, 612.413593 mm
May 18 21:24:01 lbtmu107 LBT_Networkserver: Server 4/4: name lbtmu107, load 48.340000, subsystem count 1 ( GCSL ), has rules true, last update 1211167790880
May 18 21:24:01 lbtmu107 LBT_Networkserver: update 1211171041350 lbtmu107 10.144.0.107 10.10.0.107 10.30.0.107 4 11.11 1 GCSL
May 18 21:24:20 lbtmu107 LBT_Networkserver: GCSL murdered
May 18 21:24:20 lbtmu107 LBT_Networkserver: GCSL died unexpectedly
May 18 21:24:20 lbtmu107 LBT_Networkserver: dropping GCSL
May 18 21:24:25 lbtmu107 LBT_Networkserver: GCSL has rule to run on lbtmu107
May 18 21:24:25 lbtmu107 LBT_Networkserver: GCSL starting on lbtmu107
May 18 21:24:25 lbtmu107 LBT_Networkserver: GCSL started
May 18 21:24:25 lbtmu107 LBT_Networkserver: Server 4/4: name lbtmu107, load 11.870000, subsystem count 1 ( GCSL ), has rules true, last update 1211171065363

4:35 went back to guiding, telescope was still well-collimated after 20 minutes, tweaked it a little, then going to take through focus images on IRTC.

4:49 BS9153, now moved to BS9155 about 15 degree elevation move re-check collimation, having trouble acquiring guide star, OAC server spits, re-sending guide command worked

5:02 checked collimation after 15 degree elevation move, mostly in elevation, apart from focus term everything else was within ~100 nm of where it was at most, going back to BS9153, re-setting collimation

5:04 OAC server spits again.

5:06 re-acquired, WFS shows ~200 nm Z8 from ~ 15 degrees elevation change, WFSC000013 one iteration drove everything down well, now going to IRTC star, ACT0226

5:10 can't find ACT0226, goign to WC10_226 at el 61.

5:14 applying +6000 z4 , taking 40X 0.5s exposures, images located in /Repository/IRTC_Data/080519 EF_00001_cube.fit on up to 40.

5:20 applying another +6000 z4, taking 30X 1s exposures, images from 0002_cube had the wrong (1/2 second) exposure, so the images we were after are in 00003.

5:23 taking another +6000 step, taking 10X 3s exposures, cube 00004, seems to be a little coma in the image.

5:26 going to focus, then -6000 Z4. taking 40X 0.5s exposures, cube 00005

5:28 another -6000 (total -12000z4) taking 30X 1 s exposures, cube 00006

5:35 total z4 now -18000, taking several sets of 6X 5s exposures, cirrus affected. cube 00007 has 5s exposures 60x by mistake, cube 00008 is as advertized.

5:45 seeing gone down to 2", gone back to focus and WFS star to check collimation

5:50 pointto "BS9153"

5:51-6:03 wfsc image 20-24 zernikes sent to primary

6:04 Put (z4:-300) (z5,z6,z7:+600) (z8:-600) (z9,z10:300)(z11:+300) on primary

6:05 acquire wfsc image 25 and sent to primary

Processing file wfsc000025_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =   -470.466     -646.517
Z[ 3] =   -622.060     -436.249
Z[ 4] =   1737.465     1737.465
Z[ 5] =   -299.574     -464.264
Z[ 6] =    371.336      109.973
Z[ 7] =    563.125      492.322
Z[ 8] =    125.027      300.602
Z[ 9] =    -46.234     -189.876
Z[10] =    196.852       69.538
Z[11] =   -126.300     -126.300

6:06 wfsc 26 sent to primary

Processing file wfsc000026_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =    109.107      102.656
Z[ 3] =      0.009      -36.959
Z[ 4] =    363.680      363.680
Z[ 5] =    -13.291     -210.004
Z[ 6] =    313.332      232.921
Z[ 7] =    -25.262      -24.860
Z[ 8] =      3.222       -5.528
Z[ 9] =     69.716        2.338
Z[10] =     38.492       79.602
Z[11] =     -7.467       -7.467

6:09

Processing file wfsc000028_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =  -1266.011    -1146.118
Z[ 3] =     85.822      544.577
Z[ 4] =     47.871       47.871
Z[ 5] =    -43.201      -84.202
Z[ 6] =     77.086       26.806
Z[ 7] =    -30.021      -28.157
Z[ 8] =      0.629      -10.435
Z[ 9] =     48.512      -57.573
Z[10] =     86.754       81.025
Z[11] =    -37.123      -37.123

6:10
Processing file wfsc000029_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =   -646.464     -630.044
Z[ 3] =    -82.018      166.395
Z[ 4] =      4.086        4.086
Z[ 5] =      9.667      -42.310
Z[ 6] =     70.847       57.642
Z[ 7] =     36.724       45.303
Z[ 8] =    -30.023      -14.060
Z[ 9] =    -36.483       59.278
Z[10] =    -81.037      -66.213
Z[11] =     18.331       18.331

6:11
Processing file wfsc000030_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =   -209.807     -120.940
Z[ 3] =    190.035      255.941
Z[ 4] =      2.188        2.188
Z[ 5] =     46.969       86.951
Z[ 6] =    -75.959      -20.382
Z[ 7] =    -23.954      -35.501
Z[ 8] =     34.896       23.049
Z[ 9] =    -38.371      -33.566
Z[10] =     20.499      -27.673
Z[11] =      6.015        6.015

6:12
Processing file wfsc000031_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =    193.233      121.933
Z[ 3] =   -142.709     -206.971
Z[ 4] =    -48.160      -48.160
Z[ 5] =    -28.267      -53.160
Z[ 6] =     46.576       11.929
Z[ 7] =      8.774       38.323
Z[ 8] =    -77.261      -67.658
Z[ 9] =     61.762       97.277
Z[10] =    -80.569       29.037
Z[11] =     -4.149       -4.149

6:13
Processing file wfsc000032_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =    -46.872       52.725
Z[ 3] =    239.131      237.909
Z[ 4] =      5.410        5.410
Z[ 5] =    -36.261       28.589
Z[ 6] =    -72.593      -75.943
Z[ 7] =    -19.640      -39.021
Z[ 8] =     52.536       40.289
Z[ 9] =      9.692      -60.271
Z[10] =     67.220       31.304
Z[11] =     19.780       19.780

6:14
Processing file wfsc000033_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =    123.829       31.424
Z[ 3] =   -199.554     -232.740
Z[ 4] =    -98.508      -98.508
Z[ 5] =     14.539        6.903
Z[ 6] =      3.720       13.325
Z[ 7] =     44.373       46.816
Z[ 8] =    -15.459        4.033
Z[ 9] =    -19.240       13.813
Z[10] =    -20.598      -24.569
Z[11] =     16.048       16.048

6:15
Processing file wfsc000034_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =     99.633      190.502
Z[ 3] =    239.702      176.332
Z[ 4] =     13.883       13.883
Z[ 5] =     11.504      -17.531
Z[ 6] =     33.031       30.267
Z[ 7] =    -57.652      -34.277
Z[ 8] =    -43.470      -63.549
Z[ 9] =    -30.701       10.889
Z[10] =    -20.179      -35.088
Z[11] =    -37.942      -37.942

6:17
Processing file wfsc000035_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =     12.896        5.112
Z[ 3] =    -15.444      -19.460
Z[ 4] =    -52.075      -52.075
Z[ 5] =     53.663      -24.579
Z[ 6] =     76.530       90.180
Z[ 7] =      9.503        8.944
Z[ 8] =     -0.804        3.310
Z[ 9] =    -13.683       -7.873
Z[10] =      4.577      -12.090
Z[11] =     -5.167       -5.167

6:18
Processing file wfsc000036_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =     71.932       59.344
Z[ 3] =    -12.461      -42.518
Z[ 4] =     36.394       36.394
Z[ 5] =    -65.742      -26.805
Z[ 6] =    -17.924      -62.648
Z[ 7] =      3.067      -22.232
Z[ 8] =     57.442       53.054
Z[ 9] =     11.220      -42.711
Z[10] =     46.282       21.062
Z[11] =     -3.251       -3.251

6:18
Processing file wfsc000037_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =  -1154.823     -953.805
Z[ 3] =    183.386      676.391
Z[ 4] =   -128.217     -128.217
Z[ 5] =      9.145      -40.752
Z[ 6] =     58.253       42.619
Z[ 7] =     43.977       95.165
Z[ 8] =   -125.733      -93.201
Z[ 9] =     32.521       36.222
Z[10] =    -30.559       26.066
Z[11] =      0.110        0.110

Done with this run of "Closed Loop"

6:24 Seeing still around 1.5" The original inputted Zernikes above meant that we were starting from a wavefront with about 11 microns PV, 2 microns RMS WFE.

6:30 Put ~4000 z7 on Primary. VERY comatic image on Guider

Guider image about /tmp/guiderimage023150.fits

WFSC:
Processing file wfsc000038_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =   -855.344     -884.332
Z[ 3] =   -302.276      202.339
Z[ 4] =    343.158      343.158
Z[ 5] =    153.828       87.757
Z[ 6] =    -24.358      128.666
Z[ 7] =   1322.816     1478.440
Z[ 8] =   -674.529      138.012
Z[ 9] =     59.209      124.384
Z[10] =   -132.658       75.050
Z[11] =    143.382      143.382

Processing file wfsc000039_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =    275.087     -382.357
Z[ 3] =  -1125.486    -1093.706
Z[ 4] =    205.098      205.098
Z[ 5] =   -194.233       49.335
Z[ 6] =   -140.444     -234.557
Z[ 7] =   1010.604     1216.615
Z[ 8] =   -677.604      -17.783
Z[ 9] =    -12.333     -149.832
Z[10] =    153.661      -36.252
Z[11] =    -65.516      -65.516

Processing file wfsc000040_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =     23.184      567.420
Z[ 3] =    989.700      811.220
Z[ 4] =   -271.993     -271.993
Z[ 5] =    -42.635       42.204
Z[ 6] =    -63.632      -63.919
Z[ 7] =    -64.846      -66.308
Z[ 8] =     22.237      -17.398
Z[ 9] =    -64.939       68.600
Z[10] =    -57.366      -52.933
Z[11] =    -27.969      -27.969

Processing file wfsc000041_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =     -7.467      316.285
Z[ 3] =    568.477      472.425
Z[ 4] =   -255.649     -255.649
Z[ 5] =    -27.155      -34.073
Z[ 6] =     26.106      -16.060
Z[ 7] =     19.985        9.110
Z[ 8] =     12.956       22.006
Z[ 9] =     46.649      -38.324
Z[10] =     28.100       38.691
Z[11] =     -6.085       -6.085

Processing file wfsc000042_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =    -32.767      316.205
Z[ 3] =    598.745      509.494
Z[ 4] =     -6.603       -6.603
Z[ 5] =    -65.314       18.692
Z[ 6] =    -43.785      -76.378
Z[ 7] =    -48.128        1.418
Z[ 8] =    -71.318      -86.026
Z[ 9] =     33.070       17.031
Z[10] =    -26.403       38.738
Z[11] =    -12.482      -12.482

Done with this run of "Closed Loop". The system can handle quite a bit of coma, haven't yet established an upper limit for the aberration correction.

6:41 Now driven in 6 microns z4, guider image 23393. after 1st iteration image 23434, 2nd iteration guider image 23470, 3rd iteration guider image 23509, 4th iteraton guider number 023550, 5th iteration 023593, 6th iteration 23623, 7th iteration 23640, nicely converged... guider images in /Repository/AGW_Data/080519g

Processing file wfsc000043_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =   2805.904     2652.997
Z[ 3] =    666.210    -1130.725
Z[ 4] =  -1678.776    -1678.776
Z[ 5] =   1350.590     -122.988
Z[ 6] =    544.673     1451.081
Z[ 7] =   -902.708     -212.699
Z[ 8] =   -864.505    -1231.670
Z[ 9] =    120.921      166.285
Z[10] =   -218.607      186.441
Z[11] =    337.384      337.384

Processing file wfsc000044_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =    251.403      151.535
Z[ 3] =    -81.551     -216.543
Z[ 4] =  -1208.250    -1208.250
Z[ 5] =    -40.325      261.122
Z[ 6] =   -283.023     -116.376
Z[ 7] =    272.265      -13.203
Z[ 8] =    382.651      469.442
Z[ 9] =   -360.463      -88.735
Z[10] =    234.448     -420.744
Z[11] =    303.571      303.571

Processing file wfsc000045_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =   -261.357     -370.395
Z[ 3] =   -267.814      -53.281
Z[ 4] =   -745.993     -745.993
Z[ 5] =   -505.328     -103.369
Z[ 6] =    -28.147     -495.443
Z[ 7] =    443.975       97.620
Z[ 8] =    418.011      601.928
Z[ 9] =     77.049     -206.656
Z[10] =    191.769       -2.347
Z[11] =   -373.395     -373.395

Processing file wfsc000046_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =   -387.037     -511.659
Z[ 3] =   -335.674      -26.079
Z[ 4] =  -1660.877    -1660.877
Z[ 5] =   -465.121     -104.426
Z[ 6] =     -8.068     -453.319
Z[ 7] =    160.649       57.908
Z[ 8] =    111.474      186.765
Z[ 9] =    211.489       18.462
Z[10] =   -114.604      239.835
Z[11] =   -173.233     -173.233

Processing file wfsc000047_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =   -430.233     -596.763
Z[ 3] =   -417.726      -58.904
Z[ 4] =  -1047.462    -1047.462
Z[ 5] =    -82.512     -109.534
Z[ 6] =     93.404      -59.455
Z[ 7] =     48.699        2.845
Z[ 8] =     56.616       74.625
Z[ 9] =    -54.068       51.528
Z[10] =    -31.264      -35.293
Z[11] =    -74.140      -74.140

/tmp/guiderimage023593.fits

Processing file wfsc000048_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =    -67.852      -71.144
Z[ 3] =    -29.258       19.961
Z[ 4] =   -684.640     -684.640
Z[ 5] =   -119.260       76.142
Z[ 6] =   -103.202     -138.116
Z[ 7] =    -11.841       51.243
Z[ 8] =    -96.054      -82.101
Z[ 9] =    -12.837       51.240
Z[10] =    -50.966       11.695
Z[11] =      8.197        8.197

/tmp/guiderimage023623.fits

Processing file wfsc000049_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =     22.233      -68.620
Z[ 3] =   -135.241     -118.641
Z[ 4] =   -186.987     -186.987
Z[ 5] =    -54.294       55.616
Z[ 6] =    -67.494      -66.409
Z[ 7] =     13.950        1.370
Z[ 8] =     14.836       20.318
Z[ 9] =     -4.455      -14.768
Z[10] =     19.130      -12.950
Z[11] =    -14.704      -14.704

/tmp/guiderimage023640.fits

Processing file wfsc000050_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =    206.542       43.950
Z[ 3] =   -180.043     -270.450
Z[ 4] =    -49.418      -49.418
Z[ 5] =     71.317      -56.648
Z[ 6] =     71.004       83.179
Z[ 7] =     31.409        7.620
Z[ 8] =     25.912       39.999
Z[ 9] =    -44.635       61.247
Z[10] =    -45.260      -17.019
Z[11] =     16.507       16.507

Processing file wfsc000051_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =    111.030      129.821
Z[ 3] =     69.698      -18.219
Z[ 4] =     30.591       30.591
Z[ 5] =   -100.339      -68.790
Z[ 6] =     52.498      -89.955
Z[ 7] =      7.133       -9.998
Z[ 8] =     23.989       22.943
Z[ 9] =    -24.347      -45.842
Z[10] =     67.345      -55.014
Z[11] =      5.700        5.700

Processing file wfsc000052_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =   -900.993     -655.078
Z[ 3] =     47.529      620.419
Z[ 4] =     11.255       11.255
Z[ 5] =     16.800      118.892
Z[ 6] =   -117.718       -2.138
Z[ 7] =     -2.286       24.432
Z[ 8] =    -40.363      -32.209
Z[ 9] =     -2.669        1.959
Z[10] =     -0.670       -1.934
Z[11] =     -9.407       -9.407

6:55 so have demonstrated that the system is robust enough to converge when starting from significant aberrations, in particular the most common "start-up" aberrations Z4, 7 and 8. On-axis WFS seems to be working satisfactorily for now, though there is room for some finessing (eg. not sending any but focus and coma when wavefronts are extremely aberrated, now for some off-axis stuff....

7:24 with a little help from John, got off-axis guiding going, off-axis guide star ~230" off-axis. Images in IRTC and guide camera.


/tmp/guiderimage024522.fits

Processing file wfsc000056_dd.fits
% Compiled module: ZERNIKE_ROTATION_SETUP.
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =   1301.831    -1962.271
Z[ 3] =  -1482.651     -206.185
Z[ 4] =   2765.692     2765.692
Z[ 5] =    -92.788       48.501
Z[ 6] =     18.703       81.284
Z[ 7] =     48.526       -1.900
Z[ 8] =    -32.013       58.104
Z[ 9] =    -50.660      -14.135
Z[10] =   -126.604     -135.629
Z[11] =   -145.386     -145.386

wfsc000056 shows the pupil shift for 230" off-axis. Calculated pupil shift was 23 pixels, measured pupil shift was 27 pixels, so about right there. 

/tmp/guiderimage024750.fits

Processing file wfsc000057_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =  -1274.328     1727.450
Z[ 3] =   1204.159      299.712
Z[ 4] =    455.054      455.054
Z[ 5] =    -68.907      336.999
Z[ 6] =    331.032      -27.609
Z[ 7] =     62.456      -32.936
Z[ 8] =     -5.567       53.357
Z[ 9] =    108.347       73.188
Z[10] =     81.735      114.295
Z[11] =     35.639       35.639

/tmp/guiderimage024791.fits

Processing file wfsc000058_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =    700.221    -1098.634
Z[ 3] =   -847.465      -38.862
Z[ 4] =    298.990      298.990
Z[ 5] =     74.352      -38.516
Z[ 6] =    -20.047      -66.683
Z[ 7] =     44.128     -107.930
Z[ 8] =    102.205      -27.284
Z[ 9] =      0.218       -9.009
Z[10] =     23.950       22.192
Z[11] =     56.264       56.264

/tmp/guiderimage024854.fits

Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =   -853.375      902.056
Z[ 3] =    478.027      378.224
Z[ 4] =    148.511      148.511
Z[ 5] =      5.272      -83.405
Z[ 6] =    -84.646       15.373
Z[ 7] =    -43.367       80.748
Z[ 8] =    -68.588        8.048
Z[ 9] =     32.339       57.949
Z[10] =    -69.863      -50.681
Z[11] =    -16.059      -16.059

Seeing ~2.3"

May 19 00:39:30 lbtmu107 LBT_left_GCS: star delta: 0.060395, 0.126309
May 19 00:39:30 lbtmu107 LBT_left_GCS: pcsClient.guider.applyGuideCorrection(0.460252,-138.318562);
May 19 00:39:31 lbtmu107 LBT_left_GCS: delay (286094)
May 19 00:39:31 lbtmu107 LBT_Networkserver: GCSL died unexpectedly
May 19 00:39:31 lbtmu107 LBT_Networkserver: dropping GCSL

CRAP!!!

7:41 GCS keeps dying unexpectedly except that we are expecting it now

7:47 achieve off-axis guiding using "pointto "M5_0656" gstar=1 TelMode="GUIDE" PA=INDEF"

7:53 Taking IRTC images after having closed the loop on an off-axis guide star image M5_0656_00009_cube.fit with two images, 00010 has 100 images, 00011 has 1000 frames

8:01 Looking for suitable IRTC star with a number of WFS stars nearby, to start characterizing off-axis aberrations, focal plane tilt etc. found M5_1459

8:10 gone to first guide star I.D. "1". AGW probe coordinates x=0.24 mm, y +439.6 mm, off-axis radial angular distance 288"

8:15 starting guiding, GCS died unexpectedly, start again...

8:26 achieve guiding on "1" around M5_1459

8:35 WFSC63- for closing loop on guidestar (GS) 1. Once we have closed loop seeing "off-the-scale" (>3") but our blobs in the 3" square WFS images are about 1/3rd the diameter so there is some doubt about the Polaris monitor accuracy really.

8:40 Me thinks collimation achieved in 5 iterations


Processing file wfsc000066_dd.fits
            WFSC        Rotated
Zern #   Orientation   to Primary
---------------------------------
Z[ 2] =    444.818       28.145
Z[ 3] =   -688.331     -819.067
Z[ 4] =     -0.696       -0.696
Z[ 5] =    -50.922      -67.229
Z[ 6] =     48.982      -21.740
Z[ 7] =      1.297        2.967
Z[ 8] =     -3.610       -2.431
Z[ 9] =      4.549       20.491
Z[10] =    -20.729        5.525
Z[11] =     12.457       12.457

8:40 now collimation achieved for guide star 4.8' off-axis. IRTC image looks like **. See M5_1459_00012 now we send -2225 nm focus which is the off-set from Zemax for the field curvature. New block of IRTC images is M5_1459_00014 (100 images). Looks ok.

9:07 Seeing total crud, so giving up on WFS at the moment, going to trying to work out the angle the y-axis of the agw stage is in primary mirror coordinates

9:35 Going to new star in East to minimize rotator motion. M5_0835

9:42 Rotator not getting tracking polynomials

10:07 GCS stuck multiple times, but doesn't really bother us at the moment as thick cloud has blanketed the sky

10:18 multiple failures trying to get off-axis guiding, failures once commands are sent to move stage. Can't make it work by re-starting GCSL.

10:29 error message "TCS authorize command failed for left IRTC at bent Gregorian focus" in IIF at 3:28:47 local time. Stopped and restarted CSQ multiple times to no avail.

10:34 Randy updates issuetrak 1344 "TCS reflective memory problems on LBTMU101"

10:40 restarting everything to see if that helps.

11:06 acquired stars.

11:07 lost stars, probably to clouds

11:20 closed dome at 11:21 with everything seemingly working again but clouds rolled in.

-- DougMiller and Andrew Rakich - 19 May 2008