Operating the AGw Guider and WFSC Image Acquisition

Douglas Miller 10 April 2008

The acquisition of Guider and WFSC images can be accomplished via several command line requests. For these requests to work, the AGw servers "check4nport" and "oacserver" must be running (see AGwStages Manual on the TWiki).

Currently the only computer on the mountain that can acquire images from the AGw is lbtmu107. Thus you must login to the LBTO account.

$ ssh LBTO@lbtmu107

The plan is to put all data from the Guider and WFSC in the Repository

$ cd /Repository/AGW_Data
$ mkdir (today's date)  eg 080410        (may be already created)
$ cd 080410
$ cp ~/bin/Server-PEPSIguider.ini .       (if there is not already a copy in this directory)
$ cp ~/bin/Server-PEPSIwfsc.ini .          (if there is not already a copy in this directory)

To acquire a guider image

$ guider_image
    Reading DD for Events
    loading DD for Events complete
    Reading DD for Events
    loading DD for Events complete
    Reading DD for Reflective Memory
    loading DD for Reflective Memory complete
    Image Server 1 started.
    GetDetPars = 536,528
    Pixelcount = 283008
    setting binning to 1x1
    GetDetPars now = 536,528
    AzCam Server runs version 2.4
    AzCam Server controller string is mag1
    Is AzCam Server attached to a Magellan type controller? --> 1
    CCD temp.: -51.8
    Array temp.: -51.9
    Dewar temp.: -51.9
    sending single guide commands...
    .
    Zeit f¸r 1 Bilder: 2.481667 s
    FPS: 0.402955
    SPF: 2.481667
    Image Server Shutdown.

The images are named sequencially guider00001.fits, 00002, 00003, etc

$ wfsc_image
    Reading DD for Events
    loading DD for Events complete
    Reading DD for Events
    loading DD for Events complete
    Reading DD for Reflective Memory
    loading DD for Reflective Memory complete
    Image Server 1 started.
    GetDetPars = 536,528
    Pixelcount = 283008
    setting binning to 1x1
    GetDetPars now = 536,528
    AzCam Server runs version 2.4
    AzCam Server controller string is mag1
    Is AzCam Server attached to a Magellan type controller? --> 1
    CCD temp.: -51.8
    Array temp.: -51.9
    Dewar temp.: -51.9
    sending single guide commands...
    .
    Zeit f¸r 1 Bilder: 2.481667 s
    FPS: 0.402955
    SPF: 2.481667
    Image Server Shutdown.

The images are named sequencially wfsc00001.fits, 00002, 00003, etc.

This images (ie the /Respository directorys) are visible on all linux computers on the mountain.

The default integration time for both Guider and WFSC images is 5 mili seconds. You can change the integration time by adding a -e "time in miliseconds" flag. For example

$ guider_image -e 45

will take a 45 ms image.

-- DougMiller - 20 Apr 2008