You are here: Foswiki>Commissioning Web>Logs>26Oct2012_Log (30 Oct 2012, JuanGuerra)Edit Attach

UT 20121027 AO#1

Observer: D.Miller (LBTO),K.Boutsia(INAF) A.Puglisi remote(INAF)
Telescope Operator: Geno.B.(LBTO)
Additional AO Support: JCGuerra (LBTO)
Telescope Support: Elliot (LBTO)
Instrument Support: John M (LBTO)

Summary

00:00 Troubles with authorization for test preset and other issues with GUIs.

01:29 Send acquire preset

01:32 preset AO759 ACE

01:34 Timeout waiting for slopecompctrl RMANSTERD.descimation.cur (-5001)

01:35 preset AO759 ACE

01:37 Command timeout: Arbitrator generic error

01:41 preset AO759 ACE

01:50 Error collecting pupil data: error = Guide loop did not pause in allowed time.

02:46 runao failed
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = AcquireRef[44] complete -  dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:8.404 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
        err = Resmsg[2]  = IDL variable undefined 'gainv'
        err = Resmsg[3]  = StartAO[45] failed - IDL variable undefined 'gainv'

04:20 during source extractor zernike tests we got the error:
      => StepFocus sent to PSF
===> Error in irc_stepfocus
        err = Resmsg[0]  = StepFocus result status: Error
        err = Resmsg[1]  = guide loop didn't pause within timeout
        err = Resmsg[2]  = guiding did not resume
===> Error in irc_stepfocus
% Program caused arithmetic error: Floating illegal operand

05:05 runao error
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = Timeout waiting for slopecompctrl.R.FASTLINK.ENABLE.CUR (-5001) TIMEOUT_ERROR
        err = Resmsg[2]  = AcquireRef[81] failed - Timeout waiting for slopecompctrl.R.FASTLINK.ENABLE.CUR (-5001) TIMEOUT_ERROR

05:33 error in runao
===> Error in irc_runao
        err = Resmsg[0]  = RunAO result status: Error
        err = Resmsg[1]  = Camera lens centering did not converge after 180 seconds
        err = Resmsg[2]  = AcquireRef[101] failed - Camera lens centering did not converge after 180 seconds

Collect bin2 data. The first two set were with Prim Mir. vent on and fans on. Set 1, Strehl = 42 Set 2, changed focus by 0.5mm, strehl

[AOeng@wfsdx acq]$ acq sky_irtc_psf
Resmsg[0]  = IRTC2 SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 500000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=500000 microsec, framerate=100000 hz
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[56] complete
Resmsg[2]  = OffsetXY[57] complete
Resmsg[3]  = Resume[58] complete
Resmsg[4]  = Resume[58] complete
----------------------------------------------
Current position: x=0.000 y=0.000 (arcsec)
Saved tracknum: 20121027_044027  (irtc=20 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_044041  (irtc=20 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_044056  (irtc=20 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[59] complete
Resmsg[2]  = OffsetXY[60] complete
Resmsg[3]  = Resume[61] complete
Resmsg[4]  = Resume[61] complete
----------------------------------------------
Current position: x=-3.000 y=0.000 (arcsec)
Saved IRTC dark
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[62] complete
Resmsg[2]  = OffsetXY[63] complete
Resmsg[3]  = Resume[64] complete
Resmsg[4]  = Resume[64] complete
----------------------------------------------
Current position: x=0.000 y=0.000 (arcsec)
Saved tracknum: 20121027_044211  (irtc=20 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_044224  (irtc=20 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_044239  (irtc=20 frames  ccd47=0 frames optical loop data=4000 frames)



[AOeng@wfsdx acq]$ acq sky_irtc_psf
Resmsg[0]  = IRTC2 SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 500000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=500000 microsec, framerate=100000 hz
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[70] complete
Resmsg[2]  = OffsetXY[71] complete
Resmsg[3]  = Resume[72] complete
Resmsg[4]  = Resume[72] complete
----------------------------------------------
Current position: x=0.000 y=0.000 (arcsec)
Saved tracknum: 20121027_045340  (irtc=20 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_045354  (irtc=20 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_045408  (irtc=20 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[73] complete
Resmsg[2]  = OffsetXY[74] complete
Resmsg[3]  = Resume[75] complete
Resmsg[4]  = Resume[75] complete
----------------------------------------------
Current position: x=-3.000 y=0.000 (arcsec)
Saved IRTC dark
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[76] complete
Resmsg[2]  = OffsetXY[77] complete
Resmsg[3]  = Resume[78] complete
Resmsg[4]  = Resume[78] complete
----------------------------------------------
Current position: x=0.000 y=0.000 (arcsec)
Saved tracknum: 20121027_045500  (irtc=20 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_045514  (irtc=20 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_045528  (irtc=20 frames  ccd47=0 frames optical loop data=4000 frames)
AO> a = getaoelab('20121027_045340')
AO> a->psf
% LOADCT: Loading table RED TEMPERATURE
AO> a->summary
| Tracknum                       | 20121027_045340 |
| Closed Loop                    | Yes |
| Is OK?                         | OK  |
| AntiDrift                      | ON |
| nphotons/sub/fr                | 49.325424 |
| Magnitude                      | 11.774221 |
| # Modes                        | 145 |
| Modal rec                      | Rec_20101119_180534.fits |
| Binning                        | 2 |
| Frequency [Hz]                 | 990 |
| Modulation                     | 3.030600 |
| FW1                            | Dichroic 600-1000 nm |
| FW2                            | empty |
| Gain minmax                    | 0.494000 0.933800 |
| Telescope elevation            | 77.372426 |
| Wind speed                     | NaN |
| seeing from OL modes           | 0.484547 |
| lambda [um]                    | 1.600000 |
| exptime [s]                    | 0.500000 |
| framerate [Hz]                 | 2.000000 |
| no. frames                     | 20 |
| SR SE                          | 0.479436 |
| IRTC dark                      | 20121027_045446.fits_cube.fits |


   * PSF and Modal plot of Bin 2 on SX: 
Screenshot_sx_b2.png [AOeng@wfsdx acq]$ acq sky_irtc_psf Resmsg[0] = IRTC2 SetIRParams command result: OK Resmsg[1] = New Integration time [microsec]: 500000 Resmsg[2] = New Frame Rate [Hz]: 100000 ---------------------------------------------- Set IRTC params: exptime=500000 microsec, framerate=100000 hz Resmsg[0] = OffsetPointing result status: OK Resmsg[1] = Pause[88] complete Resmsg[2] = OffsetXY[89] complete Resmsg[3] = Resume[90] complete Resmsg[4] = Resume[90] complete ---------------------------------------------- Current position: x=0.000 y=0.000 (arcsec) Saved tracknum: 20121027_051703 (irtc=20 frames ccd47=0 frames optical loop data=4000 frames) Saved tracknum: 20121027_051716 (irtc=20 frames ccd47=0 frames optical loop data=4000 frames) Saved tracknum: 20121027_051730 (irtc=20 frames ccd47=0 frames optical loop data=4000 frames) Resmsg[0] = OffsetPointing result status: OK Resmsg[1] = Pause[91] complete Resmsg[2] = OffsetXY[92] complete Resmsg[3] = Resume[93] complete Resmsg[4] = Resume[93] complete ---------------------------------------------- Current position: x=-3.000 y=0.000 (arcsec) Saved IRTC dark Resmsg[0] = OffsetPointing result status: OK Resmsg[1] = Pause[94] complete Resmsg[2] = OffsetXY[95] complete Resmsg[3] = Resume[96] complete Resmsg[4] = Resume[96] complete ---------------------------------------------- Current position: x=0.000 y=0.000 (arcsec) Saved tracknum: 20121027_051824 (irtc=20 frames ccd47=0 frames optical loop data=4000 frames) Saved tracknum: 20121027_051837 (irtc=20 frames ccd47=0 frames optical loop data=4000 frames) Saved tracknum: 20121027_051851 (irtc=20 frames ccd47=0 frames optical loop data=4000 frames) AO> a = getaoelab('20121027_051703') AO> a->psf AO> a->summary | Tracknum | 20121027_051703 | | Closed Loop | Yes | | Is OK? | OK | | AntiDrift | ON | | nphotons/sub/fr | 48.319630 | | Magnitude | 11.796589 | | # Modes | 145 | | Modal rec | Rec_20101119_180534.fits | | Binning | 2 | | Frequency [Hz] | 990 | | Modulation | 3.030600 | | FW1 | Dichroic 600-1000 nm | | FW2 | empty | | Gain minmax | 0.452000 0.933800 | | Telescope elevation | 74.001666 | | Wind speed | NaN | | seeing from OL modes | 0.383434 | | lambda [um] | 1.600000 | | exptime [s] | 0.500000 | | framerate [Hz] | 2.000000 | | no. frames | 20 | | SR SE | 0.595389 | | IRTC dark | 20121027_051811.fits_cube.fits |

Bin 4

[AOeng@wfsdx acq]$ acq sky_irtc_psf
Resmsg[0]  = IRTC2 SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 2000000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=2000000 microsec, framerate=100000 hz
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[186] complete
Resmsg[2]  = OffsetXY[187] complete
Resmsg[3]  = Resume[188] complete
Resmsg[4]  = Resume[188] complete
----------------------------------------------
Current position: x=0.000 y=0.000 (arcsec)
Saved tracknum: 20121027_111517  (irtc=10 frames  ccd47=0 frames optical loop data=4000 frames)
Error saving optical loop data: 
Saved tracknum: 20121027_111605  (irtc=10 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[189] complete
Resmsg[2]  = OffsetXY[190] complete
Resmsg[3]  = Resume[191] complete
Resmsg[4]  = Resume[191] complete
----------------------------------------------
Current position: x=-3.000 y=0.000 (arcsec)
Saved IRTC dark
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[192] complete
Resmsg[2]  = OffsetXY[193] complete
Resmsg[3]  = Resume[194] complete
Resmsg[4]  = Resume[194] complete
----------------------------------------------
Current position: x=0.000 y=0.000 (arcsec)
Saved tracknum: 20121027_111716  (irtc=10 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_111741  (irtc=10 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_111805  (irtc=10 frames  ccd47=0 frames optical loop data=4000 frames)

The image below shows the PSF in IRTC that it was close to the edge and the modal plot of the corrected modes. Star on the edge, no strehl

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20121027_111716 ??? 15.6 73 5 NaN 0.46 083227 4 36 200 1.8 1.7 0.5 6 31 ON 0.0 H 2000 10 ONSKY zero.fits - Pupils not on target - Center of PSF estimation error
20121027_111741 ??? 15.6 73 5 NaN 0.46 083227 4 36 200 1.8 1.7 0.5 6 31 ON 0.0 H 2000 10 ONSKY zero.fits - Center of PSF estimation error
20121027_111805 ??? 15.7 73 5 NaN 0.45 083227 4 36 200 1.8 1.7 0.5 6 31 ON 0.0 H 2000 10 ONSKY zero.fits - Center of PSF estimation error

  • PSF and Modal plot of Bin 4 on SX:
    Screenshot_b4_sx.png

Elevation = 31, bin1

Resmsg[0]  = IRTC2 SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 20000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=20000 microsec, framerate=100000 hz
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[229] complete
Resmsg[2]  = OffsetXY[230] complete
Resmsg[3]  = Resume[231] complete
Resmsg[4]  = Resume[231] complete
----------------------------------------------
Current position: x=0.000 y=0.000 (arcsec)
Saved tracknum: 20121027_122015  (irtc=100 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_122031  (irtc=100 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_122045  (irtc=100 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[232] complete
Resmsg[2]  = OffsetXY[233] complete
Resmsg[3]  = Resume[234] complete
Resmsg[4]  = Resume[234] complete
----------------------------------------------
Current position: x=-3.000 y=0.000 (arcsec)
Saved IRTC dark
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[235] complete
Resmsg[2]  = OffsetXY[236] complete
Resmsg[3]  = Resume[237] complete
Resmsg[4]  = Resume[237] complete
----------------------------------------------
Current position: x=0.000 y=0.000 (arcsec)
Saved tracknum: 20121027_122135  (irtc=100 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_122148  (irtc=100 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_122207  (irtc=100 frames  ccd47=0 frames optical loop data=4000 frames)

AO> a->summary
| Tracknum                       | 20121027_122135 |
| Closed Loop                    | Yes |
| Is OK?                         | OK  |
| AntiDrift                      | ON |
| nphotons/sub/fr                | 150.128983 |
| Magnitude                      | 8.991185 |
| # Modes                        | 400 |
| Modal rec                      | Rec_20101024_092604.fits |
| Binning                        | 1 |
| Frequency [Hz]                 | 989 |
| Modulation                     | 2.996182 |
| FW1                            | Dichroic 600-1000 nm |
| FW2                            | empty |
| Gain minmax                    | 0.000000 0.980000 |
| Telescope elevation            | 34.247594 |
| Wind speed                     | NaN |
| seeing from OL modes           | 0.329244 |
| lambda [um]                    | 1.600000 |
| exptime [s]                    | 0.020000 |
| framerate [Hz]                 | 50.000000 |
| no. frames                     | 100 |
| SR SE                          | 0.654319 |
| IRTC dark                      | 20121027_122122.fits_cube.fits |

elevation 32, bin 2

Resmsg[0]  = IRTC2 SetIRParams command result: OK
Resmsg[1]  = New Integration time [microsec]: 2000000
Resmsg[2]  = New Frame Rate [Hz]: 100000
----------------------------------------------
Set IRTC params: exptime=2000000 microsec, framerate=100000 hz
^[[AResmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[242] complete
Resmsg[2]  = OffsetXY[243] complete
Resmsg[3]  = Resume[244] complete
Resmsg[4]  = Resume[244] complete
----------------------------------------------
Current position: x=0.000 y=0.000 (arcsec)
Saved tracknum: 20121027_123328  (irtc=10 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_123353  (irtc=10 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_123417  (irtc=10 frames  ccd47=0 frames optical loop data=4000 frames)
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[245] complete
Resmsg[2]  = OffsetXY[246] complete
Resmsg[3]  = Resume[247] complete
Resmsg[4]  = Resume[247] complete
----------------------------------------------
Current position: x=-3.000 y=0.000 (arcsec)
Saved IRTC dark
Resmsg[0]  = OffsetPointing result status: OK
Resmsg[1]  = Pause[248] complete
Resmsg[2]  = OffsetXY[249] complete
Resmsg[3]  = Resume[250] complete
Resmsg[4]  = Resume[250] complete
----------------------------------------------
Current position: x=0.000 y=0.000 (arcsec)
Saved tracknum: 20121027_123530  (irtc=10 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_123555  (irtc=10 frames  ccd47=0 frames optical loop data=4000 frames)
Saved tracknum: 20121027_123619  (irtc=10 frames  ccd47=0 frames optical loop data=4000 frames)

AO> a->summary
| Tracknum                       | 20121027_123530 |
| Closed Loop                    | Yes |
| Is OK?                         | OK  |
| AntiDrift                      | ON |
| nphotons/sub/fr                | 25.301033 |
| Magnitude                      | 13.483766 |
| # Modes                        | 145 |
| Modal rec                      | Rec_20101119_180534.fits |
| Binning                        | 2 |
| Frequency [Hz]                 | 400 |
| Modulation                     | 3.068859 |
| FW1                            | Dichroic 600-1000 nm |
| FW2                            | empty |
| Gain minmax                    | 0.536000 2.100000 |
| Telescope elevation            | 31.702985 |
| Wind speed                     | NaN |
| seeing from OL modes           | 0.469789 |
| lambda [um]                    | 1.600000 |
| exptime [s]                    | 2.000000 |
| framerate [Hz]                 | 0.500000 |
| no. frames                     | 10 |
| SR SE                          | 0.354517 |
| IRTC dark                      | 20121027_123516.fits_cube.fits |

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20121027_123328 ??? 13.6 31 5 NaN 0.43 180534 2 145 400 2.1 0.9 0.5 3 24 ON 41.3 H 2000 10 ONSKY zero.fits   H 2000 10 ONSKY zero.fits  
20121027_123417 ??? 13.6 32 5 NaN 0.41 180534 2 145 400 2.1 0.9 0.5 3 24 ON 37.8 H 2000 10 ONSKY zero.fits  
20121027_123530 ??? 13.5 32 5 NaN 0.47 180534 2 145 400 2.1 0.9 0.5 3 25 ON 35.5 H 2000 10 ONSKY zero.fits  
20121027_123555 ??? 13.4 32 5 NaN 0.47 180534 2 145 400 2.1 0.9 0.5 3 27 ON 31.1 H 2000 10 ONSKY zero.fits  
20121027_123619 ??? 13.5 32 5 NaN 0.52 180534 2 145 400 2.1 0.9 0.5 3 26 ON 32.9 H 2000 10 ONSKY zero.fits - Background correction failed

-- DougMiller - 27 Oct 2012

I Attachment Action Size Date Who Comment
Screenshot_b4_sx.pngpng Screenshot_b4_sx.png manage 48 K 30 Oct 2012 - 18:24 UnknownUser PSF and Modal plot of Bin 4 on SX
Screenshot_sx_b2.pngpng Screenshot_sx_b2.png manage 55 K 30 Oct 2012 - 17:14 UnknownUser PSF nad Modal plot of Bin 2 on SX
Topic revision: r7 - 30 Oct 2012, JuanGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback