You are here: Foswiki>Commissioning Web>Logs>25Apr2012_Log (26 Apr 2012, JuanGuerra)Edit Attach

UT 20120425 AO#2 Commissioning

Observer: R. Bruglia, A. Puglisi, E. Pinna (LBTO)
Telescope Operator: D.Gonzalez (LBTO)
Additional AO Support: JCGuerra (LBTO)
Telescope Support: JLittle(LBTO)
Instrument Support: D. Officer (LBTO)

Summary

Retro-Reflector daytime work.

Set of the Right secondary shell failure.

hand-over:4:20

Details

09:00 Retro- installed in the telescope and systems are started up. Not problems

16:02

Failure of the set FLAT of the right saecondary. Check  the log.
AOARB.R            |WAR|       174|2012-04-25 16:02:03.648605|             MAIN > Error reading WFS state variable. Cannot update status
AOARB.R            |ERR|       175|2012-04-25 16:02:09.646322|     ALERTHANDLER > COILS DISABLED
### Actuator 343 jump in position.

17:50.

* The secondary left went in failure. Crate 1 failure.

* The secondary power off/on.

* Test noise done.

* Set Flat after 5 minutes and the secondary responds well. SETFLAT ok.

* Temperature crate 1 stratix:36.5C. 

Improvement of the Acquire Ref.

The acquire reference has been improved with an option Click'nGo, this is useful feature for crowdy fields and manual interaction during the acquire reference.

Test of Field stabilization

Test using the AOS for the TTM observing mode.

NOTE: Three House ON. HBS on, The breaks off

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120425_202028 ??? 7.5 90 2 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2607 ON 0.4 J 2000 5 ON NO - Background correction failed
20120425_202041 ??? 7.5 90 1 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2585 ON 0.4 J 2000 5 ON NO - Background correction failed
20120425_202055 ??? 7.5 90 4 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2576 ON 0.4 J 2000 5 ON NO  
20120425_202133 ??? 7.5 90 4 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2537 ON 0.3 J 2000 5 ON NO - Pupils not on target
20120425_202147 ??? 7.5 90 3 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2572 ON 0.3 J 2000 5 ON NO - Background correction failed
20120425_202201 ??? 7.5 90 4 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2572 ON 0.3 J 2000 5 ON NO  
20120425_202225 ??? 7.5 90 4 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2554 ON 0.4 J 2000 5 ON NO - Background correction failed
20120425_202237 ??? 7.5 90 3 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2559 ON ** J 2000 5 ON NO - SR may be in error
20120425_202251 ??? 7.5 90 5 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2548 ON 0.3 J 2000 5 ON NO - long stop of 66 frames at frame 839 - Background correction failed
20120425_202329 ??? 7.5 90 6 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2489 ON 0.3 J 2000 5 ON NO  
20120425_202343 ??? 7.5 90 5 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2514 ON 0.3 J 2000 5 ON NO  
20120425_202357 ??? 7.5 90 3 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2506 ON 0.3 J 2000 5 ON NO - Background correction failed
20120425_202441 ??? 7.5 90 6 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2489 ON 0.3 J 2000 5 ON NO - Background correction failed
20120425_202454 ??? 7.5 90 4 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2490 ON 0.3 J 2000 5 ON NO  
20120425_202508 ??? 7.5 90 5 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2474 ON 0.3 J 2000 5 ON NO  
20120425_202546 ??? 7.6 90 4 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2418 ON 0.3 J 2000 5 ON NO - Pupils not on target
20120425_202600 ??? 7.5 90 4 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2438 ON 0.3 J 2000 5 ON NO  
20120425_202614 ??? 7.5 90 4 NaN -1.00 204258 2 5 991 1.8 1.7 0.0 3 2450 ON 0.3 J 2000 5 ON NO - Background correction failed


modalplot

THREE HOUSE OFF, HBS ON, BREACKS ON.

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120425_211029 ??? 7.3 90 8 NaN -1.00 204258 2 5 991 1.4 1.4 0.0 3 3028 ON 0.5 J 2000 5 ON NO  
20120425_211042 ??? 7.3 90 4 NaN -1.00 204258 2 5 991 1.4 1.4 0.0 3 3028 ON 0.5 J 2000 5 ON NO  
20120425_211056 ??? 7.3 90 3 NaN -1.00 204258 2 5 991 1.4 1.4 0.0 3 3018 ON 0.5 J 2000 5 ON NO - Background correction failed
20120425_211134 ??? 7.4 90 6 NaN -1.00 204258 2 5 991 1.4 1.4 0.0 3 2906 ON 0.5 J 2000 5 ON NO - Pupils not on target
20120425_211148 ??? 7.3 90 6 NaN -1.00 204258 2 5 991 1.4 1.4 0.0 3 3010 ON 0.5 J 2000 5 ON NO - Pupils not on target
20120425_211202 ??? 7.3 90 7 NaN -1.00 204258 2 5 991 1.4 1.4 0.0 3 3022 ON 0.4 J 2000 5 ON NO  
20120425_211310 ??? 7.3 90 3 NaN -1.00 204258 2 5 991 1.4 1.4 0.0 3 3020 ON 0.4 J 2000 5 ON NO  
20120425_211324 ??? 7.3 90 3 NaN -1.00 204258 2 5 991 1.4 1.4 0.0 3 3019 ON 0.4 J 2000 5 ON NO - long stop of 77 frames at frame 3831 - Background correction failed
20120425_211338 ??? 7.3 90 3 NaN -1.00 204258 2 5 991 1.4 1.4 0.0 3 3020 ON 0.4 J 2000 5 ON NO  
20120425_211416 ??? 7.3 90 9 NaN -1.00 204258 2 5 991 1.4 1.4 0.0 3 2963 ON 0.4 J 2000 5 ON NO - Pupils not on target
20120425_211430 ??? 7.3 90 7 NaN -1.00 204258 2 5 991 1.4 1.4 0.0 3 2990 ON 0.4 J 2000 5 ON NO  
20120425_211444 ??? 7.3 90 6 NaN -1.00 204258 2 5 991 1.4 1.4 0.0 3 2995 ON 0.4 J 2000 5 ON NO - Background correction failed

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120425_212746 ??? 10.4 90 3 NaN -1.00 203413 4 5 401 2.2 1.7 0.0 6 1916 ON 0.9 J 2000 5 ON NO  
20120425_212759 ??? 10.4 90 3 NaN -1.00 203413 4 5 401 2.2 1.7 0.0 6 1911 ON 0.7 J 2000 5 ON NO  
20120425_212813 ??? 10.4 90 5 NaN -1.00 203413 4 5 401 2.2 1.7 0.0 6 1911 ON 0.6 J 2000 5 ON NO - SR may be in error
20120425_212851 ??? 10.5 90 5 NaN -1.00 203413 4 5 401 2.2 1.7 0.0 6 1749 ON ** J 2000 5 ON NO - SR may be in error
20120425_212905 ??? -NaN 90 5 NaN -1.00 203413 4 5 401 2.2 1.7 0.0 6 -1 ON 2.5 J 2000 5 ON NO  
20120425_212919 ??? -NaN 90 5 NaN -1.00 203413 4 5 401 2.2 1.7 0.0 6 -1 ON 2.5 J 2000 5 ON NO - SR may be in error
20120425_212941 ??? -NaN 90 5 NaN -1.00 203413 4 5 401 2.2 1.7 0.0 6 -1 ON 2.6 J 2000 5 ON NO  
20120425_212955 ??? 10.4 90 4 NaN -1.00 203413 4 5 401 2.2 1.7 0.0 6 1865 ON 2.2 J 2000 5 ON NO  
20120425_213009 ??? 10.4 90 4 NaN -1.00 203413 4 5 401 2.2 1.7 0.0 6 1855 ON 2.5 J 2000 5 ON NO  
20120425_213047 ??? 10.5 90 5 NaN -1.00 203413 4 5 401 2.2 1.7 0.0 6 1718 ON 2.7 J 2000 5 ON NO - Pupils not on target
20120425_213101 ??? 10.5 90 7 NaN -1.00 203413 4 5 401 2.2 1.7 0.0 6 1776 ON ** J 2000 5 ON NO - Pupils not on target - SR may be in error
20120425_213115 ??? -NaN 90 4 NaN -1.00 203413 4 5 401 2.2 1.7 0.0 6 -1 ON -1.0 ? -1 -1 ON NO  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120425_214034 ??? 13.2 90 6 NaN -1.00 203413 4 5 401 2.3 1.1 0.0 6 140 ON 410.4 J 2000 5 ON NO - Could not test SR quality
20120425_214048 ??? 13.2 90 6 NaN -1.00 203413 4 5 401 2.3 1.1 0.0 6 143 ON ** J 2000 5 ON NO - Could not test SR quality
20120425_214102 ??? 13.2 90 7 NaN -1.00 203413 4 5 401 2.3 1.1 0.0 6 143 ON ** J 2000 5 ON NO - Could not test SR quality
20120425_214140 ??? 13.6 90 4 NaN -1.00 203413 4 5 401 2.3 1.1 0.0 6 103 ON 1218.2 J 2000 5 ON NO - Could not test SR quality
20120425_214154 ??? 13.3 90 7 NaN -1.00 203413 4 5 401 2.3 1.1 0.0 6 130 ON 278.3 J 2000 5 ON NO - SR may be in error
20120425_214208 ??? 13.3 90 5 NaN -1.00 203413 4 5 401 2.3 1.1 0.0 6 135 ON 793.6 J 2000 5 ON NO - Could not test SR quality
20120425_214230 ??? 13.3 90 7 NaN -1.00 203413 4 5 401 2.3 1.1 0.0 6 132 ON 11.2 J 2000 5 ON NO - SR may be in error
20120425_214242 ??? 13.3 90 6 NaN -1.00 203413 4 5 401 2.3 1.1 0.0 6 133 ON 0.0 J 2000 5 ON NO - Center of PSF estimation error
20120425_214256 ??? 13.3 90 6 NaN -1.00 203413 4 5 401 2.3 1.1 0.0 6 135 ON 15.7 J 2000 5 ON NO - SR may be in error
20120425_214334 ??? 13.6 90 8 NaN -1.00 203413 4 5 401 2.3 1.1 0.0 6 103 ON 30.0 J 2000 5 ON NO - SR may be in error
20120425_214348 ??? 13.5 90 7 NaN -1.00 203413 4 5 401 2.3 1.1 0.0 6 111 ON 253.3 J 2000 5 ON NO - SR may be in error
20120425_214402 ??? 13.3 90 9 NaN -1.00 203413 4 5 401 2.3 1.1 0.0 6 132 ON ** J 2000 5 ON NO - long stop of 83 frames at frame 2857 - SR may be in error

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120425_220056 ??? 16.2 90 6 NaN -1.00 203413 4 5 100 2.6 1.9 0.0 6 37 ON 157.9 J 2000 5 ON NO - SR may be in error
20120425_220138 ??? 16.3 90 6 NaN -1.00 203413 4 5 100 2.6 1.9 0.0 6 34 ON 532.0 J 2000 5 ON NO - SR may be in error
20120425_220220 ??? 16.2 90 5 NaN -1.00 203413 4 5 100 2.6 1.9 0.0 6 36 ON 311.3 J 2000 5 ON NO - SR may be in error

  • TTM_bin4_breacksON:
    TTM_bin4_breackON.png

  • TTM_breacksoff:
    TTM_breacksoff.png

  • TTM_breackON:
    TTM-breackson.png

15:00 Test performance Bin1

Riproviamo le performance a bin1. Oggi abbiamo anche i freni del telescopio aperti, oltre a HBS on, TH Left & right off

Testiamo anche qui il click'n'go -> OK

Per sbaglio carichiamo con l'AOS il rec sintetico a 250

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120425_221514 ??? 7.3 90 5 NaN -1.00 000250 1 250 990 0.8 0.7 0.5 3 722 ON 39.0 J 50 200 ON NO - Pupils mismatch
20120425_221539 ??? 7.3 90 7 NaN -1.00 000250 1 250 990 0.8 0.7 0.5 3 714 ON 40.6 J 50 200 ON NO - Pupils mismatch
20120425_221603 ??? 7.3 90 6 NaN -1.00 000250 1 250 990 0.8 0.7 0.5 3 709 ON 39.2 J 50 200 ON NO - Pupils mismatch
20120425_221703 ??? 7.3 90 4 NaN -1.00 000250 1 250 990 0.8 0.7 0.5 3 711 ON 38.3 J 50 200 ON NO - Pupils mismatch
20120425_221727 ??? 7.3 90 5 NaN -1.00 000250 1 250 990 0.8 0.7 0.5 3 721 ON 36.4 J 50 200 ON NO - Pupils mismatch
20120425_221752 ??? 7.3 90 6 NaN -1.00 000250 1 250 990 0.8 0.7 0.5 3 715 ON 39.6 J 50 200 ON NO - Pupils mismatch
IDL string: ['20120425_221514','20120425_221539','20120425_221603','20120425_221703','20120425_221727','20120425_221752']

Ripristiniamo la normale tabella AOS

Test 400 modi rec da tabella

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120425_222227 ??? 7.3 90 4 NaN -1.00 180658 1 400 990 0.6 0.4 0.4 3 712 ON 39.8 J 50 200 ON NO - Pupils mismatch
20120425_222252 ??? 7.3 90 3 NaN -1.00 180658 1 400 990 0.6 0.4 0.4 3 704 ON 44.8 J 50 200 ON NO - Pupils mismatch
20120425_222317 ??? 7.3 90 6 NaN -1.00 180658 1 400 990 0.6 0.4 0.4 3 707 ON 39.8 J 50 200 ON NO - Pupils mismatch
20120425_222416 ??? 7.4 90 5 NaN -1.00 180658 1 400 990 0.6 0.4 0.4 3 672 ON 44.7 J 50 200 ON NO - Pupils mismatch
20120425_222440 ??? 7.3 90 5 NaN -1.00 180658 1 400 990 0.6 0.4 0.4 3 705 ON 39.1 J 50 200 ON NO - Pupils mismatch
20120425_222504 ??? 7.3 90 6 NaN -1.00 180658 1 400 990 0.6 0.4 0.4 3 708 ON 45.4 J 50 200 ON NO - Pupils mismatch
20120425_222604 ??? 7.3 90 5 NaN -1.00 180658 1 400 990 0.6 0.4 0.4 3 712 ON 39.4 J 50 200 ON NO - Pupils mismatch
20120425_222628 ??? 7.3 90 6 NaN -1.00 180658 1 400 990 0.6 0.4 0.4 3 709 ON 43.4 J 50 200 ON NO - Pupils mismatch
20120425_222653 ??? 7.3 90 5 NaN -1.00 180658 1 400 990 0.6 0.4 0.4 3 711 ON 39.9 J 50 200 ON NO - Pupils mismatch
20120425_222753 ??? 7.4 90 5 NaN -1.00 180658 1 400 990 0.6 0.4 0.4 3 672 ON 44.2 J 50 200 ON NO - Pupils mismatch
20120425_222817 ??? 7.3 90 6 NaN -1.00 180658 1 400 990 0.6 0.4 0.4 3 707 ON 41.4 J 50 200 ON NO - Pupils mismatch
20120425_222841 ??? 7.3 90 6 NaN -1.00 180658 1 400 990 0.6 0.4 0.4 3 719 ON 44.0 J 50 200 ON NO - Pupils mismatch
IDL string: ['20120425_222227','20120425_222252','20120425_222317','20120425_222416','20120425_222440','20120425_222504','20120425_222604','20120425_222628','20120425_222653','20120425_222753','20120425_222817','20120425_222841']

Test 500 modi rec 20120202_181326

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120425_223619 ??? 7.3 90 5 NaN -1.00 181326 1 500 990 0.5 0.5 0.5 3 711 ON 36.7 J 50 200 ON NO  
20120425_223644 ??? 7.3 90 5 NaN -1.00 181326 1 500 990 0.5 0.5 0.5 3 717 ON 37.5 J 50 200 ON NO  
20120425_223708 ??? 7.3 90 6 NaN -1.00 181326 1 500 990 0.5 0.5 0.5 3 715 ON 40.9 J 50 200 ON NO  
20120425_223807 ??? 7.4 90 5 NaN -1.00 181326 1 500 990 0.5 0.5 0.5 3 675 ON 38.7 J 50 200 ON NO  
20120425_223831 ??? 7.3 90 6 NaN -1.00 181326 1 500 990 0.5 0.5 0.5 3 708 ON 39.3 J 50 200 ON NO  
20120425_223855 ??? 7.3 90 8 NaN -1.00 181326 1 500 990 0.5 0.5 0.5 3 714 ON 40.4 J 50 200 ON NO  
20120425_223928 ??? 7.3 90 5 NaN -1.00 181326 1 500 990 0.5 0.5 0.5 3 710 ON 39.7 J 50 200 ON NO  
20120425_223953 ??? 7.3 90 4 NaN -1.00 181326 1 500 990 0.5 0.5 0.5 3 715 ON 39.4 J 50 200 ON NO  
20120425_224017 ??? 7.3 90 3 NaN -1.00 181326 1 500 990 0.5 0.5 0.5 3 712 ON 40.7 J 50 200 ON NO  
20120425_224116 ??? 7.4 90 5 NaN -1.00 181326 1 500 990 0.5 0.5 0.5 3 673 ON 38.5 J 50 200 ON NO  
20120425_224141 ??? 7.3 90 4 NaN -1.00 181326 1 500 990 0.5 0.5 0.5 3 707 ON 41.7 J 50 200 ON NO  
20120425_224205 ??? 7.3 90 4 NaN -1.00 181326 1 500 990 0.5 0.5 0.5 3 714 ON 39.1 J 50 200 ON NO  
IDL string: ['20120425_223619','20120425_223644','20120425_223708','20120425_223807','20120425_223831','20120425_223855','20120425_223928','20120425_223953','20120425_224017','20120425_224116','20120425_224141','20120425_224205']

Test 550 modi rec 20120209_054609

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120425_224519 ??? 7.3 90 5 NaN -1.00 054609 1 550 990 0.6 0.5 0.4 3 715 ON 40.0 J 50 200 ON NO  
20120425_224543 ??? 7.3 90 4 NaN -1.00 054609 1 550 990 0.6 0.5 0.4 3 711 ON 44.3 J 50 200 ON NO  
20120425_224607 ??? 7.3 90 4 NaN -1.00 054609 1 550 990 0.6 0.5 0.4 3 711 ON 38.4 J 50 200 ON NO  
20120425_224706 ??? 7.4 90 5 NaN -1.00 054609 1 550 990 0.6 0.5 0.4 3 681 ON 41.6 J 50 200 ON NO  
20120425_224731 ??? 7.3 90 6 NaN -1.00 054609 1 550 990 0.6 0.5 0.4 3 715 ON 39.1 J 50 200 ON NO  
20120425_224755 ??? 7.3 90 7 NaN -1.00 054609 1 550 990 0.6 0.5 0.4 3 713 ON 40.1 J 50 200 ON NO  
20120425_224854 ??? 7.3 90 4 NaN -1.00 054609 1 550 990 0.6 0.5 0.4 3 713 ON 41.1 J 50 200 ON NO  
20120425_224917 ??? 7.3 90 6 NaN -1.00 054609 1 550 990 0.6 0.5 0.4 3 716 ON 42.9 J 50 200 ON NO  
20120425_224942 ??? 7.3 90 5 NaN -1.00 054609 1 550 990 0.6 0.5 0.4 3 712 ON 42.4 J 50 200 ON NO - long stop of 63 frames at frame 631

  • modalplot_compar.png: Confronto dei campioni (SR piu' alti del set) di 400 500 e 550 modi
    modalplot_compar.png

16:00 Bad seeing test

Usianmo dei rec esistenti con un disturbo a 1.7".

Test 300 modi

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120425_230428 ??? 7.3 90 6 NaN -1.00 175701 1 300 990 0.9 0.6 0.5 3 726 ON 19.2 J 50 200 ON NO  
20120425_230452 ??? 7.3 90 7 NaN -1.00 175701 1 300 990 0.9 0.6 0.5 3 732 ON 20.9 J 50 200 ON NO  
20120425_230516 ??? 7.3 90 8 NaN -1.00 175701 1 300 990 0.9 0.6 0.5 3 732 ON 19.1 J 50 200 ON NO  
20120425_230615 ??? 7.3 90 7 NaN -1.00 175701 1 300 990 0.9 0.6 0.5 3 696 ON 21.1 J 50 200 ON NO - Pupils not on target
20120425_230639 ??? 7.3 90 8 NaN -1.00 175701 1 300 990 0.9 0.6 0.5 3 725 ON 19.8 J 50 200 ON NO  
20120425_230704 ??? 7.3 90 7 NaN -1.00 175701 1 300 990 0.9 0.6 0.5 3 730 ON 20.0 J 50 200 ON NO  
IDL string: ['20120425_230428','20120425_230452','20120425_230516','20120425_230615','20120425_230639','20120425_230704']

Test 250 modi
TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120425_230858 ??? 7.3 90 4 NaN -1.00 185250 1 250 990 1.1 0.6 0.5 3 732 ON 15.2 J 50 200 ON NO  
20120425_230922 ??? 7.3 90 3 NaN -1.00 185250 1 250 990 1.1 0.6 0.5 3 732 ON 14.0 J 50 200 ON NO  
20120425_230947 ??? 7.3 90 4 NaN -1.00 185250 1 250 990 1.1 0.6 0.5 3 728 ON 14.8 J 50 200 ON NO  
20120425_231046 ??? 7.3 90 4 NaN -1.00 185250 1 250 990 1.1 0.6 0.5 3 694 ON 13.0 J 50 200 ON NO - Pupils not on target
20120425_231111 ??? 7.3 90 6 NaN -1.00 185250 1 250 990 1.1 0.6 0.5 3 726 ON 14.0 J 50 200 ON NO  
20120425_231135 ??? 7.3 90 7 NaN -1.00 185250 1 250 990 1.1 0.6 0.5 3 729 ON 13.9 J 50 200 ON NO  

Proviamo anche il 400 modi ma fa skip frame sull'autogain

-- JuanGuerra - 25 Apr 2012
  • crate1_failure:
    crate1_failure2.png

  • TTM_breaksON:
    TTM-breackson.png

  • TTM-breacksOFF:
    TTM_breacksoff.png

  • modalplot_bin1_comp:
    modalplot_compar.png

  • TTM-bin4_breackON:
    TTM_bin4_breackON.png
I Attachment Action Size Date Who Comment
TTM-breackson.pngpng TTM-breackson.png manage 14 K 26 Apr 2012 - 00:44 UnknownUser TTM_breaksON
TTM_bin4_breackON.pngpng TTM_bin4_breackON.png manage 13 K 26 Apr 2012 - 00:46 UnknownUser TTM-bin4_breackON
TTM_breacksoff.pngpng TTM_breacksoff.png manage 14 K 26 Apr 2012 - 00:45 UnknownUser TTM-breacksOFF
crate1_failure2.pngpng crate1_failure2.png manage 88 K 26 Apr 2012 - 00:39 UnknownUser crate1_failure
modalplot_compar.pngpng modalplot_compar.png manage 22 K 26 Apr 2012 - 00:46 UnknownUser modalplot_bin1_comp
Topic revision: r3 - 26 Apr 2012, JuanGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback