You are here: Foswiki>Commissioning Web>Logs>24Apr2012_Log (24 Apr 2012, JuanGuerra)Edit Attach

UT 20120424 AO#2 Commissioning

Observer: R. Bruglia, A. Puglisi, E. Pinna (LBTO)
Telescope Operator: D.Gonzalez (LBTO)
Additional AO Support: JCGuerra (LBTO)
Telescope Support: JLittle(LBTO)
Instrument Support: J. Morris (LBTO)

Summary

Retro-Reflector work.

Identification of the zero rotator angle position. The value for zero rotator is 117.6

close loop performances and system stability. It is important to see if the secondary is stable working in close loop regimes.

hand-over:4:20

Details

09:00 Retro- installed in the telescope and systems are started up. Not problems

Working in the determination of the rotaotr zero position. This angle was retrieved at 117.6 degrees. Tom Sargent and Dan Cox updated the configuration file with this new value as zero position. After this new values was in the system, the AO system could close the loop without any other rotation problems.

Close loop at different binings

The AO system is tested to work at different binnings. Test done in a high flux range

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120424_175159 ??? 7.3 90 6 NaN -1.00 180658 1 400 990 0.5 0.5 0.5 3 714 ON 32.4 J 70 100 ON NO  
20120424_175214 ??? 7.3 90 4 NaN -1.00 180658 1 400 990 0.5 0.5 0.5 3 721 ON 29.8 J 70 100 ON NO  
20120424_175229 ??? 7.3 90 2 NaN -1.00 180658 1 400 990 0.5 0.5 0.5 3 719 ON 29.8 J 70 100 ON NO  
20120424_175310 ??? 7.3 90 4 NaN -1.00 180658 1 400 990 0.5 0.5 0.5 3 705 ON 29.2 J 70 100 ON NO  
20120424_175326 ??? 7.3 90 7 NaN -1.00 180658 1 400 990 0.5 0.5 0.5 3 709 ON 33.3 J 70 100 ON NO  
20120424_175341 ??? 7.3 90 4 NaN -1.00 180658 1 400 990 0.5 0.5 0.5 3 714 ON 30.9 J 70 100 ON NO  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120424_182956 ??? 8.5 90 2 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1058 ON 21.8 J 300 40 ON NO - Background correction failed
20120424_183040 ??? 8.5 90 5 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1000 ON 21.3 J 300 40 ON NO  
20120424_183056 ??? 8.5 90 4 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1033 ON 21.9 J 300 40 ON NO  
20120424_183113 ??? 8.5 90 3 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1038 ON 19.7 J 300 40 ON NO  
20120424_183352 ??? 8.5 90 6 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1054 ON 22.3 J 300 40 ON NO  
20120424_183408 ??? 8.5 90 8 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1044 ON 21.4 J 300 40 ON NO  
20120424_183425 ??? 8.5 90 7 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1043 ON 21.4 J 300 40 ON NO  
20120424_183509 ??? 8.5 90 3 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1006 ON 18.2 J 300 40 ON NO  
20120424_183526 ??? 8.5 90 6 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1020 ON 15.4 J 300 40 ON NO  
20120424_183542 ??? 8.5 90 5 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1037 ON 18.3 J 300 40 ON NO  
20120424_184039 ??? 8.5 90 1 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1053 ON 23.2 J 300 40 ON NO  
20120424_184056 ??? 8.5 90 3 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1048 ON 21.4 J 300 40 ON NO  
20120424_184113 ??? 8.5 90 7 NaN -1.00 222220 2 153 991 0.7 0.5 0.4 3 1047 ON 20.0 J 300 40 ON NO  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120424_180457 ??? 7.3 90 8 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6280 ON 8.7 J 200 50 ON NO  
20120424_180512 ??? 7.3 90 5 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6283 ON 9.4 J 200 50 ON NO  
20120424_180527 ??? 7.3 90 4 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6284 ON 9.0 J 200 50 ON NO  
20120424_180609 ??? 7.3 90 6 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6186 ON 9.0 J 200 50 ON NO  
20120424_180624 ??? 7.3 90 2 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6244 ON 8.9 J 200 50 ON NO  
20120424_180640 ??? 7.3 90 8 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6265 ON 8.9 J 200 50 ON NO  
20120424_180703 ??? 7.3 90 4 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6282 ON 8.9 J 200 50 ON NO  
20120424_180718 ??? 7.3 90 6 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6278 ON 8.9 J 200 50 ON NO  
20120424_180733 ??? 7.3 90 2 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6278 ON 9.3 J 200 50 ON NO  
20120424_180814 ??? 7.3 90 6 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6206 ON 8.7 J 200 50 ON NO - Pupils not on target
20120424_180830 ??? 7.3 90 4 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6247 ON 9.4 J 200 50 ON NO  
20120424_180845 ??? 7.3 90 2 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6267 ON 9.2 J 200 50 ON NO  
20120424_180937 ??? 7.3 90 9 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6279 ON 9.1 J 200 50 ON NO  
20120424_180953 ??? 7.3 90 8 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6279 ON 8.9 J 200 50 ON NO  
20120424_181008 ??? 7.3 90 4 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6276 ON 9.3 J 200 50 ON NO  
20120424_181050 ??? 7.3 90 3 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6203 ON 9.1 J 200 50 ON NO - Pupils not on target
20120424_181105 ??? 7.3 90 3 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6244 ON 9.3 J 200 50 ON NO  
20120424_181120 ??? 7.3 90 7 NaN -1.00 201828 3 66 990 0.6 0.5 0.4 6 6264 ON 8.9 J 200 50 ON NO  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120424_181729 ??? 8.6 90 8 NaN -1.00 200610 4 36 994 0.6 0.4 0.0 6 4184 ON 3.8 J 700 20 ON NO - Background correction failed
20120424_181747 ??? 8.6 90 7 NaN -1.00 200610 4 36 994 0.6 0.4 0.0 6 4179 ON 3.7 J 700 20 ON NO  
20120424_181804 ??? 8.6 90 5 NaN -1.00 200610 4 36 994 0.6 0.4 0.0 6 4180 ON 3.5 J 700 20 ON NO  
20120424_181850 ??? 8.6 90 5 NaN -1.00 200610 4 36 994 0.6 0.4 0.0 6 4038 ON 3.6 J 700 20 ON NO  
20120424_181908 ??? 8.6 90 2 NaN -1.00 200610 4 36 994 0.6 0.4 0.0 6 4109 ON 3.0 J 700 20 ON NO  
20120424_181925 ??? 8.6 90 6 NaN -1.00 200610 4 36 994 0.6 0.4 0.0 6 4144 ON 3.6 J 700 20 ON NO - Background correction failed
20120424_182016 ??? 8.6 90 4 NaN -1.00 200610 4 36 994 0.6 0.4 0.0 6 4171 ON 3.4 J 700 20 ON NO - Background correction failed
20120424_182033 ??? 8.6 90 2 NaN -1.00 200610 4 36 994 0.6 0.4 0.0 6 4166 ON 3.3 J 700 20 ON NO  
20120424_182051 ??? 8.6 90 3 NaN -1.00 200610 4 36 994 0.6 0.4 0.0 6 4166 ON 3.6 J 700 20 ON NO - Background correction failed
20120424_182137 ??? 8.6 90 9 NaN -1.00 200610 4 36 994 0.6 0.4 0.0 6 3936 ON 3.0 J 700 20 ON NO - Pupils not on target - Background correction failed
20120424_182154 ??? 8.6 90 6 NaN -1.00 200610 4 36 994 0.6 0.4 0.0 6 4114 ON 3.4 J 700 20 ON NO - Pupils not on target
20120424_182212 ??? 8.6 90 5 NaN -1.00 200610 4 36 994 0.6 0.4 0.0 6 4139 ON 3.2 J 700 20 ON NO  

Secondary "stress" test.

19:00 A disturbance with a bad seeing is loaded to the secondary and the loop is closed to leave the disturbance running. The secondary runs without any problem (after three hours).

Recovery AO system after shell RIP.

The operations of recovery during a skip frame has been improved and the AO system (WFS and Secondary ) are reporting the right status.

Tip/Tilt mode.

Working on the TT Mode. New lookup table of reconstructors and optimizations for the different binnings. We need to consider high flux objects. The TTM has a lookup table for bin 1, 2 and 4

Some preliminar results at bin 1

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120424_220316 ??? 7.2 90 1 NaN -1.00 205513 1 5 990 1.3 1.4 0.0 3 753 ON 0.5 J 1500 10 ON NO - Background correction failed
20120424_220335 ??? 7.2 90 2 NaN -1.00 205513 1 5 990 1.3 1.4 0.0 3 752 ON 0.5 J 1500 10 ON NO - Background correction failed
20120424_220353 ??? 7.2 90 3 NaN -1.00 205513 1 5 990 1.3 1.4 0.0 3 764 ON 0.4 J 1500 10 ON NO  
20120424_220439 ??? 7.3 90 1 NaN -1.00 205513 1 5 990 1.3 1.4 0.0 3 747 ON 0.4 J 1500 10 ON NO  
20120424_220457 ??? 7.2 90 3 NaN -1.00 205513 1 5 990 1.3 1.4 0.0 3 760 ON 0.5 J 1500 10 ON NO  
20120424_220515 ??? 7.2 90 1 NaN -1.00 205513 1 5 990 1.3 1.4 0.0 3 758 ON 0.5 J 1500 10 ON NO  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120424_224000 ??? 7.3 90 2 NaN -1.00 204258 2 5 991 1.0 0.7 0.0 3 3092 ON 0.5 J 1500 10 ON NO - Background correction failed
20120424_224018 ??? 7.3 90 3 NaN -1.00 204258 2 5 991 1.0 0.7 0.0 3 3109 ON 0.5 J 1500 10 ON NO  
20120424_224036 ??? 7.3 90 1 NaN -1.00 204258 2 5 991 1.0 0.7 0.0 3 3123 ON 0.6 J 1500 10 ON NO  
20120424_224150 ??? 7.3 90 1 NaN -1.00 204258 2 5 991 1.0 0.7 0.0 3 3131 ON 0.5 J 1500 10 ON NO - long stop of 83 frames at frame 1459 - Background correction failed
20120424_224209 ??? 7.3 90 2 NaN -1.00 204258 2 5 991 1.0 0.7 0.0 3 3137 ON 0.5 J 1500 10 ON NO  
20120424_224227 ??? 7.3 90 1 NaN -1.00 204258 2 5 991 1.0 0.7 0.0 3 3139 ON 0.5 J 1500 10 ON NO - long stop of 80 frames at frame 1944
20120424_224313 ??? 7.3 90 1 NaN -1.00 204258 2 5 991 1.0 0.7 0.0 3 3084 ON 0.5 J 1500 10 ON NO - Background correction failed
20120424_224331 ??? 7.3 90 2 NaN -1.00 204258 2 5 991 1.0 0.7 0.0 3 3109 ON 0.5 J 1500 10 ON NO  
20120424_224349 ??? 7.3 90 3 NaN -1.00 204258 2 5 991 1.0 0.7 0.0 3 3129 ON 0.5 J 1500 10 ON NO  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120424_225123 ??? 10.8 90 8 NaN -1.00 203413 4 5 501 1.5 1.5 0.0 6 1045 ON 4386.1 J 2000 5 ON NO - oversampling freq not a multiple of loop freq - Could not test SR quality
20120424_225136 ??? 10.8 90 6 NaN -1.00 203413 4 5 501 1.5 1.5 0.0 6 1049 ON 50.4 J 2000 5 ON NO - oversampling freq not a multiple of loop freq
20120424_225150 ??? 10.8 90 3 NaN -1.00 203413 4 5 501 1.5 1.5 0.0 6 1048 ON ** J 2000 5 ON NO - oversampling freq not a multiple of loop freq - SR may be in error
20120424_225228 ??? 10.9 90 8 NaN -1.00 203413 4 5 501 1.5 1.5 0.0 6 952 ON 12.9 J 2000 5 ON NO - oversampling freq not a multiple of loop freq - SR may be in error
20120424_225242 ??? 10.9 90 6 NaN -1.00 203413 4 5 501 1.5 1.5 0.0 6 993 ON 0.0 J 2000 5 ON NO - oversampling freq not a multiple of loop freq - Center of PSF estimation failed
20120424_225256 ??? 10.8 90 8 NaN -1.00 203413 4 5 501 1.5 1.5 0.0 6 1008 ON 3.4 J 2000 5 ON NO - oversampling freq not a multiple of loop freq - SR may be in error

-- JuanGuerra - 24 Apr 2012
  • TTM_bin1:
    TTM_bin1.png
Topic revision: r3 - 24 Apr 2012, JuanGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.