You are here: Foswiki>Commissioning Web>Logs>22Mar013_Log (24 Mar 2013, JuanGuerra)Edit Attach

UT 20130322 AO#2

Observer: D.Miller (LBTO),J. Christou(LBTO),JC,Guerra(LBTO)
Telescope Operator: Geno.B.(LBTO)
SW Support: (Tucson)
AO Support: (LBTO)
Telescope Support: Kevin N (LBTO)
Instrument Support: Elliot S (LBTO)

Summary.

  • AO#2 on SX on sky.
  • AO#1 in the lab. Planning to back on telescope Saturday morning.
  • Alfio has patched the two issues from last night; for the bayside stage increasing the time out to 20 seconds. the bad seeing table is include in the configuration files.
  • Moon:80% full
  • DIMM will run a new option to save the images. The Option to save DIMM images works.
Issues found:

  • The bin2 didn't work, it has recognize that the reconstructor is not quite good.
  • Bayside stage y didn't work well. some times was stuck and other time the slit moved and the psf was almost centred in the hot spot the time out error come out.

Details.

WFS power on from AOS without any problem.

Fri Mar 22 23:29:55.710 2013 aos.WfsOn.started - WfsOn[58] (wfs:FLAOWFS) Fri Mar 22 23:32:44.143 2013 aos.WfsOn.complete - WfsOn[58] complete

DIMM images are stored locally in dimm computer:/home/dimmuser/restart/

CCD39 RON TEST

dome lights off

ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.73 - RON (e-): 9.37 (estimated)
Speed: 890 kpix/sec - RON (ADU): 14.13 - RON (e-): 7.06 (estimated)
Speed: 400 kpix/sec - RON (ADU): 8.43 - RON (e-): 4.21 (estimated)

ccd39 - binning 1
Speed: 2500 kpix/sec - RON (ADU): 18.78 - RON (e-): 9.39 (estimated)
Speed: 890 kpix/sec - RON (ADU): 14.14 - RON (e-): 7.07 (estimated)
Speed: 400 kpix/sec - RON (ADU): 8.45 - RON (e-): 4.22 (estimated)

AO307

Sat Mar 23 02:32:10.007 2013 aos.PresetAO.started - PresetAO[69] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-3.3861e-06,ro2:2.21081e-08,mag:8.36,cindex:2.42,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 02:36:32.189 2013 aos.AcquireRef.started - AcquireRef[70]

Sat Mar 23 02:39:01.457 2013 aos.AcquireRef.complete - AcquireRef[70] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:9.121 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3 Sat Mar 23 02:39:01.478 2013 aos.StartAO.started - StartAO[71]

Failed

Sat Mar 23 02:45:25.090 2013 aos.info - Maximum skip reached
Sat Mar 23 02:45:25.131 2013 aos.error - Stopping WFS...

variable seeing

Sat Mar 23 02:53:46.534 2013 aos.PresetAO.complete - PresetAO[73] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3

Sat Mar 23 02:56:32.645 2013 aos.info - AcquireRef mode: Move stages, Automatic acquire Sat Mar 23 02:56:32.659 2013 aos.AcquireRef.started - AcquireRef[74]

Sat Mar 23 02:59:35.410 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 02:59:35.411 2013 aos.StartAO.complete - StartAO[75] complete

trac_num:20130323_025953 _030014 4000 frames _030029 4000 frames _030055 10000 frames _030135 10000 frames

loop break variable seeing.
Sat Mar 23 03:02:23.222 2013 aos.info - Maximum skip reached
Sat Mar 23 03:02:23.239 2013 aos.error - Stopping WFS...
Sat Mar 23 03:02:23.569 2013 aos.info - Updated variable AOARB.L.LOOPON: 0

Sat Mar 23 03:05:18.433 2013 aos.PresetAO.started - PresetAO[77] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-3.75607e-08,ro2:6.73246e-09,mag:8.36,cindex:2.42,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 23 03:06:46.103 2013 aos.AcquireRef.started - AcquireRef[78]

Sat Mar 23 03:09:36.936 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 03:09:36.937 2013 aos.StartAO.complete - StartAO[79] complete

The loop is open. Maximum skip frame reached Sat Mar 23 03:13:04.718 2013 aos.info - COILS DISABLED Sat Mar 23 03:14:26.885 2013 aos.info - Updated variable AOARB.L.LOOPON: 0

track_num:20130323_031001 10000 frames _031034 10000 frames _031206 _031245

Tracknum 20130323_031245
Closed Loop Yes
Is OK? No - long stop of 93 frames at frame 9002
AntiDrift ON
nphotons/sub/fr 107.393608
Magnitude 9.369031
# Modes 400
Modal rec Rec_20120601_181313.fits
Binning 1
Frequency [Hz] 989
Modulation 2.998804
FW1 Dichroic 600-1000 nm
FW2 empty
Gain minmax 0.000000 1.400000
Telescope elevation 77.515869
Wind speed NaN
seeing from OL modes 1.256337

seeing changes from0.8" to 1.3", the shell rip

Shell didn't recover.. The actuator #005 jump.Three times to set the shell

Same star preset:

Sat Mar 23 03:22:51.694 2013 aos.info - Bad seeing set ON

Sat Mar 23 03:23:09.726 2013 aos.PresetAO.started - PresetAO[85] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:0.00386976,ro2:0.0019327,mag:8.36,cindex:2.42,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 2

Sat Mar 23 03:25:18.793 2013 aos.AcquireRef.started - AcquireRef[86]

preset failed. rot angle 306

Sat Mar 23 03:25:55.636 2013 aos.AcquireRef.failed - AcquireRef[86] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

Same preset changing rot angle.

Rot angle: 277

Sat Mar 23 03:27:41.856 2013 aos.PresetAO.started - PresetAO[88] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:2.92527e-07,ro2:5.47282e-07,mag:8.36,cindex:2.42,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 03:28:52.185 2013 aos.AcquireRef.started - AcquireRef[89]

Sat Mar 23 03:31:33.840 2013 aos.AcquireRef.complete - AcquireRef[89] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:9.049 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3 Sat Mar 23 03:31:33.8624 2013 aos.StartAO.started - StartAO[90]

REc:20120202_185250.. Check reconstructor number of modes.

track.num: 20130323_033408

Sat Mar 23 03:32:21.867 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 03:32:21.867 2013 aos.StartAO.complete - StartAO[90] complete

_034129 10000 _034219 10000 _034313 10000 _034347 4000 _034416 " _034441 " _034539 " _034638 10000 _034709 "

Sat Mar 23 03:48:02.015 2013 aos.info - Updated variable AOARB.L.LOOPON: 0

Same preset:

Sat Mar 23 03:48:10.575 2013 aos.PresetAO.started - PresetAO[92] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-2.35252e-06,ro2:2.79168e-06,mag:8.36,cindex:2.42,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 03:49:17.534 2013 aos.AcquireRef.started - AcquireRef[93] Sat Mar 23 03:51:15.541 2013 aos.AcquireRef.complete - AcquireRef[93] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:8.999 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3 Sat Mar 23 03:51:15.562 2013 aos.StartAO.started - StartAO[94]

Sat Mar 23 03:52:01.663 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 03:52:01.664 2013 aos.StartAO.complete - StartAO[94] complete

track.num:20130323_035219 10000 _035305 " _035409 " _035448 4000 _035544 " _035605 " _040015 " _040155 10000 _040237 "

Sat Mar 23 04:05:37.971 2013 aos.info - Updated variable AOARB.L.LOOPON: 0

rot position:346

Sat Mar 23 04:05:43.146 2013 aos.PresetAO.started - PresetAO[96] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:2.73897e-06,ro2:-1.43973e-06,mag:8.36,cindex:2.42,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 23 04:08:07.809 2013 aos.AcquireRef.started - AcquireRef[97]

Sat Mar 23 04:11:04.594 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 04:11:04.594 2013 aos.StartAO.complete - StartAO[98] complete

track_num:20130323_041127 10000 _041212 " _041245 " _041331 4000 _041408 " _041521 " _041615 50000

Tracknum 20130323_041408
Closed Loop Yes
Is OK? OK
AntiDrift ON
nphotons/sub/fr -1.000000
Magnitude -NaN
# Modes 250
Modal rec Rec_20120202_185250.fits
Binning 1
Frequency [Hz] 989
Modulation 2.998804
FW1 Dichroic 600-1000 nm
FW2 empty
Gain minmax 1.370000 1.580000
Telescope elevation 84.583898
Wind speed NaN
seeing from OL modes 0.789259

Sat Mar 23 04:20:27.762 2013 aos.info - Bad seeing set OFF Sat Mar 23 04:20:33.908 2013 aos.Stop.complete - Stop[99] complete Sat Mar 23 04:20:33.915 2013 aos.info - Updated variable AOARB.L.LOOPON: 0

rot angle:366

Sat Mar 23 04:21:16.965 2013 aos.PresetAO.complete - PresetAO[100] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3

Sat Mar 23 04:22:06.998 2013 aos.AcquireRef.started - AcquireRef[101]

Failed during the autogain.

Sat Mar 23 04:25:01.618 2013 aos.StartAO.failed - StartAO[102] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE Sat Mar 23 04:25:01.628 2013 aos.info - Upda

same preset:

Sat Mar 23 04:25:22.193 2013 aos.PresetAO.started - PresetAO[104] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:3.04419e-06,ro2:-1.48974e-06,mag:8.36,cindex:2.42,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 04:26:36.468 2013 aos.AcquireRef.started - AcquireRef[105]

Sat Mar 23 04:27:03.541 2013 aos.info - Updated variable AOARB.L.FSM_STATE: Operational Sat Mar 23 04:27:03.598 2013 aos.AcquireRef.failed - AcquireRef[105] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

rot angle:287

Sat Mar 23 04:27:47.507 2013 aos.PresetAO.started - PresetAO[107] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:7.25013e-07,ro2:9.34548e-07,mag:8.36,cindex:2.42,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 04:29:50.998 2013 aos.AcquireRef.started - AcquireRef[108]

Sat Mar 23 04:32:44.402 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 04:32:44.403 2013 aos.StartAO.complete - StartAO[109] complete

thye loop is close but we can see that it is continously skipping frames

track_num:20130323_043344 4000 _043352 _043431 _043449 10000 _043522 " _043555 " _043759 " _043920 " _044030 4000 _044136 " _044155 "

Tracknum 20130323_044155
Closed Loop Yes
Is OK? OK
AntiDrift ON
nphotons/sub/fr -1.000000
Magnitude -NaN
# Modes 400
Modal rec Rec_20120601_181313.fits
Binning 1
Frequency [Hz] 989
Modulation 2.998804
FW1 Dichroic 600-1000 nm
FW2 empty
Gain minmax 0.000000 1.127000
Telescope elevation 81.332509
Wind speed NaN
seeing from OL modes 0.809280

Sat Mar 23 04:46:53.191 2013 aos.info - COILS DISABLED Sat Mar 23 04:47:18.907 2013 aos.info - Updated variable AOARB.L.LOOPON: 0

Landolt_290_0

rot angle 304

seeing variable poor..

Sat Mar 23 04:57:54.604 2013 aos.PresetAO.complete - PresetAO[113] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3

ar 23 05:04:29.483 2013 aos.info - Updated variable wfsarb.L.FSM_STATE@M_FLAOWFS: AOSet Sat Mar 23 05:04:29.586 2013 aos.error - Stopping AdSec Sat Mar 23 05:04:29.739 2013 aos.info - Updated variable AOARB.L.FSM_STATE: Operational Sat Mar 23 05:04:29.740 2013 aos.StartAO.failed - StartAO[115] failed Sat Mar 23 05:02:38.366 2013 aos.AcquireRef.started - AcquireRef[114]

failed

Sat Mar 23 05:04:29.209 2013 aos.info - Maximum skip reached Sat Mar 23 05:04:29.221 2013 aos.error - Stopping WFS...

Sat Mar 23 05:05:43.993 2013 aos.info - Bad seeing set ON Sat Mar 23 05:05:58.192 2013 aos.PresetAO.started - PresetAO[117] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-3.13032e-08,ro2:5.97761e-07,mag:9.54,cindex:1.03,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 05:07:12.814 2013 aos.AcquireRef.started - AcquireRef[118]

Sat Mar 23 05:09:32.108 2013 aos.info - Maximum skip reached Sat Mar 23 05:09:32.150 2013 aos.error - Stopping WFS...

seeing 1.8"

stop in this position changing target.

AO395

bad seeing table enabled

Sat Mar 23 05:14:48.148 2013 aos.PresetAO.started - PresetAO[121] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:2.1118e-06,ro2:2.4426e-07,mag:9.89,cindex:1.51,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 05:19:55.045 2013 aos.AcquireRef.started - AcquireRef[122]

Sat Mar 23 05:21:28.795 2013 aos.info - WFS: star found, estimated magnitude: 10.52 Sat Mar 23 05:23:26.251 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 05:23:26.251 2013 aos.StartAO.complete - StartAO[123] complete

track_num:20130323_052455 4000 _052533 " _052608 " _052639 " _052700 10000 _052753 "

Sat Mar 23 05:28:21.386 2013 aos.Stop.complete - Stop[124] complete Sat Mar 23 05:28:21.398 2013 aos.info - Updated variable AOARB.L.LOOPON: 0

same target:

Sat Mar 23 05:28:24.670 2013 aos.PresetAO.started - PresetAO[125] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:3.3707e-07,ro2:4.59906e-07,mag:9.89,cindex:1.51,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 05:29:15.269 2013 aos.AcquireRef.started - AcquireRef[126]

Sat Mar 23 05:30:46.621 2013 aos.info - WFS: star found, estimated magnitude: 10.26

Sat Mar 23 05:31:21.808 2013 aos.info - Maximum skip reached Sat Mar 23 05:31:21.858 2013 aos.error - Stopping WFS...

seeing 1.4"

same target:

Sat Mar 23 05:34:17.842 2013 aos.PresetAO.started - PresetAO[129] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-8.27852e-07,ro2:4.67125e-08,mag:9.89,cindex:1.51,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 05:35:11.687 2013 aos.AcquireRef.started - AcquireRef[130]

saving close loop data: _053555 during the process...

Sat Mar 23 05:36:55.682 2013 aos.info - WFS: star found, estimated magnitude: 10.42

Sat Mar 23 05:37:23.262 2013 aos.StartAO.started - StartAO[131] Sat Mar 23 05:37:24.370 2013 aos.info - Updated variable adsecarb.L.FSM_STATE: AORunning Sat Mar 23 05:37:24.490 2013 aos.info - Updated variable wfsarb.L.FSM_STATE@M_FLAOWFS: LoopClosed

Sat Mar 23 05:37:32.171 2013 aos.info - Maximum skip reached Sat Mar 23 05:37:32.201 2013 aos.error - Stopping WFS...

bad seeing mode disabled. same target

Sat Mar 23 05:38:47.201 2013 aos.PresetAO.started - PresetAO[133] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-6.50529e-07,ro2:4.44802e-07,mag:9.89,cindex:1.51,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 05:39:44.302 2013 aos.AcquireRef.started - AcquireRef[134] Sat Mar 23 05:41:15.228 2013 aos.info - Updated variable adsecarb.L.FSM_STATE: AOSet Sat Mar 23 05:41:20.299 2013 aos.info - WFS: star found, estimated magnitude: 10.45

Sat Mar 23 05:41:53.839 2013 aos.info - Maximum skip reached Sat Mar 23 05:41:53.890 2013 aos.error - Stopping WFS...

suspecting problem with the pupils in the recosntructor. Moving to a new target fainter.

Changing star:

AO400

rot angle:250

Sat Mar 23 05:47:05.819 2013 aos.PresetAO.started - PresetAO[137] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:2.9322e-07,ro2:-2.67283e-06,mag:13.7,cindex:3,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 05:50:16.949 2013 aos.AcquireRef.started - AcquireRef[138] Sat Mar 23 05:50:47.156 2013 aos.AcquireRef.failed - AcquireRef[138] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

Sat Mar 23 05:51:34.622 2013 aos.PresetAO.started - PresetAO[140] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:3.89453e-08,ro2:-1.72608e-06,mag:13.7,cindex:3,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 05:52:50.599 2013 aos.AcquireRef.started - AcquireRef[141]

Sat Mar 23 05:53:21.063 2013 aos.info - Updated variable AOARB.L.FSM_STATE: Operational Sat Mar 23 05:53:21.121 2013 aos.AcquireRef.failed - AcquireRef[141] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

Rot Ang:312

Sat Mar 23 05:54:10.091 2013 aos.PresetAO.started - PresetAO[143] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-9.63735e-07,ro2:5.30524e-07,mag:13.7,cindex:3,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

dimm:1.4"

Sat Mar 23 05:56:16.430 2013 aos.PresetAO.failed - PresetAO[143] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

rot ang:314

Sat Mar 23 05:58:21.297 2013 aos.AcquireRef.started - AcquireRef[146]

Sat Mar 23 05:57:19.831 2013 aos.PresetAO.complete - PresetAO[145] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:0 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6

Sat Mar 23 06:00:49.203 2013 aos.StartAO.started - StartAO[147]

Sat Mar 23 06:00:02.483 2013 aos.info - WFS: star found, estimated magnitude: 13.36 Sat Mar 23 06:00:49.185 2013 aos.AcquireRef.complete - AcquireRef[146] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:13.363 nBins:2 nModes:110 r0:0 snMode:0 strehl:0 ttMod:3 Sat Mar 23 06:00:49.203 2013 aos.StartAO.started - StartAO[147] Sat Mar 23 06:01:01.604 2013 aos.StartAO.failed - StartAO[147] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE

Screenshot_bin2_rotation.png

AO476

rot angle: 286

Sat Mar 23 06:08:12.890 2013 aos.PresetAO.started - PresetAO[149] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-7.40067e-07,ro2:7.76086e-07,mag:14.2,cindex:2.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 06:10:54.599 2013 aos.AcquireRef.started - AcquireRef[150]

bayside stage y didn't move. Sat Mar 23 06:11:23.953 2013 aos.info - Updated variable AOARB.L.FSM_STATE: Operational Sat Mar 23 06:11:24.009 2013 aos.AcquireRef.failed - AcquireRef[150] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

temperature -2

Sat Mar 23 06:12:44.701 2013 aos.AcquireRef.started - AcquireRef[153]

Sat Mar 23 06:13:14.150 2013 aos.AcquireRef.failed - AcquireRef[153] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

stage moved by hand

Sat Mar 23 06:14:13.088 2013 aos.PresetAO.started - PresetAO[155] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-4.7258e-07,ro2:6.42855e-07,mag:14.2,cindex:2.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 06:15:01.363 2013 aos.info - AcquireRef mode: Move stages, Automatic acquire Sat Mar 23 06:15:01.375 2013 aos.AcquireRef.started - AcquireRef[156]

Sat Mar 23 06:15:31.572 2013 aos.AcquireRef.failed - AcquireRef[156] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

change different rot angle.

x:-77.578 1.2A y:-51.453 -1.71A

Rot angle: 350

Sat Mar 23 06:16:24.203 2013 aos.PresetAO.started - PresetAO[158] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-8.90955e-07,ro2:-2.66025e-07,mag:14.2,cindex:2.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 23 06:17:49.308 2013 aos.info - AcquireRef mode: Move stages, Automatic acquire Sat Mar 23 06:17:49.322 2013 aos.AcquireRef.started - AcquireRef[159]

Sat Mar 23 06:18:23.150 2013 aos.AcquireRef.failed - AcquireRef[159] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

change different rot angle.

rot angle:230

Sat Mar 23 06:19:02.394 2013 aos.PresetAO.started - PresetAO[161] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:4.45568e-07,ro2:3.56173e-07,mag:14.2,cindex:2.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

preset failed by active optics

Sat Mar 23 06:20:29.398 2013 aos.PresetAO.started - PresetAO[163] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:4.2415e-07,ro2:1.92543e-06,mag:14.2,cindex:2.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

dimm:1.5"

Sat Mar 23 06:21:36.691 2013 aos.AcquireRef.started - AcquireRef[164]

Sat Mar 23 06:23:01.399 2013 aos.info - WFS: star found, estimated magnitude: 13.79

Sat Mar 23 06:23:31.494 2013 aos.AcquireRef.complete - AcquireRef[164] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:13.787 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6 Sat Mar 23 06:23:31.513 2013 aos.StartAO.started - StartAO[165]

Sat Mar 23 06:24:55.897 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 06:24:55.898 2013 aos.StartAO.complete - StartAO[165] complete

track_num:20130323_062532 _062602 _062651 _062755

Tracknum 20130323_062602
Closed Loop Yes
Is OK? OK
AntiDrift ON
nphotons/sub/fr 76.676186
Magnitude 13.805687
# Modes 66
Modal rec Rec_20120330_201828.fits
Binning 3
Frequency [Hz] 199
Modulation 5.998998
FW1 Dichroic 600-1000 nm
FW2 empty
Gain minmax 2.100000 3.000000
Telescope elevation 71.384881
Wind speed NaN
seeing from OL modes 1.098161

Sat Mar 23 06:32:03.916 2013 aos.PresetAO.started - PresetAO[167] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.52961e-07,ro2:-3.42293e-08,mag:14.2,cindex:2.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 06:33:42.326 2013 aos.AcquireRef.failed - AcquireRef[168] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

Sat Mar 23 06:34:07.233 2013 aos.PresetAO.started - PresetAO[170] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:8.0393e-08,ro2:2.82176e-06,mag:14.2,cindex:2.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 06:34:59.125 2013 aos.AcquireRef.started - AcquireRef[171] Sat Mar 23 06:34:59.260 2013 aos.info - WFS: starting source acquisition procedure Sat Mar 23 06:35:29.278 2013 aos.info - Updated variable AOARB.L.FSM_STATE: Operational Sat Mar 23 06:35:29.335 2013 aos.AcquireRef.failed - AcquireRef[171] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

Sat Mar 23 06:36:34.221 2013 aos.PresetAO.started - PresetAO[173] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-5.29152e-07,ro2:-3.18145e-07,mag:14.2,cindex:2.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar Sat Mar 23 06:38:20.302 2013 aos.AcquireRef.started - AcquireRef[174]

Sat Mar 23 06:40:23.182 2013 aos.StartAO.started - StartAO[175] Sat Mar 23 06:41:52.122 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 06:41:52.122 2013 aos.StartAO.complete - StartAO[175] complete

Track_num:"20130323_064219 _064400 _064520

Sat Mar 23 06:45:45.633 2013 aos.PresetAO.started - PresetAO[177] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-3.89273e-07,ro2:-1.19311e-07,mag:14.2,cindex:2.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 06:46:38.264 2013 aos.info - AcquireRef mode: Move stages, Automatic acquire Sat Mar 23 06:46:38.278 2013 aos.AcquireRef.started - AcquireRef[178] Sat Mar 23 06:48:09.604 2013 aos.info - WFS: star found, estimated magnitude: 13.75 Sat Mar 23 06:50:04.165 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 06:50:04.165 2013 aos.StartAO.complete - StartAO[179] complete

Track_num:20130323_065020 _065118 _065149 Sat Mar 23 06:52:27.421 2013 aos.Stop.complete - Stop[180] complete Sat Mar 23 06:52:27.434 2013 aos.info - Updated variable AOARB.L.LOOPON: 0

Sat Mar 23 06:52:30.159 2013 aos.PresetAO.started - PresetAO[181] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.18136e-06,ro2:-2.99407e-08,mag:14.2,cindex:2.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 23 06:53:54.666 2013 aos.info - AcquireRef mode: Move stages, Automatic acquire Sat Mar 23 06:53:54.682 2013 aos.AcquireRef.started - AcquireRef[182]

Sat Mar 23 06:56:19.190 2013 aos.StartAO.started - StartAO[183]

Sat Mar 23 06:57:42.957 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 06:57:42.958 2013 aos.StartAO.complete - StartAO[183] complete

20130323_065801 _070051

AO477

Rot angle:137

Sat Mar 23 07:02:15.348 2013 aos.PresetAO.started - PresetAO[185] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-4.1117e-07,ro2:-7.75056e-08,mag:15.1,cindex:1.5,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 07:05:10.778 2013 aos.AcquireRef.started - AcquireRef[186] Sat Mar 23 07:06:55.655 2013 aos.info - WFS: star found, estimated magnitude: 14.26

Sat Mar 23 07:09:20.133 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 07:09:20.134 2013 aos.StartAO.complete - StartAO[187] complete

Sat Mar 23 07:13:46.927 2013 aos.Stop.complete - Stop[188] complete Sat Mar 23 07:13:46.942 2013 aos.info - Updated variable AOARB.L.LOOPON: 0

Sat Mar 23 07:13:49.756 2013 aos.PresetAO.started - PresetAO[189] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-2.06301e-08,ro2:-3.9207e-07,mag:15.1,cindex:1.5,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir Sat Mar 23 07:16:30.855 2013 aos.AcquireRef.started - AcquireRef[190]

Sat Mar 23 07:20:15.022 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 07:20:15.023 2013 aos.StartAO.complete - StartAO[191] complete

trac_num:20130323_072116 _072149

Sat Mar 23 07:22:46.921 2013 aos.PresetAO.started - PresetAO[193] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.61383e-07,ro2:-1.76071e-07,mag:15.1,cindex:1.5,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 07:24:32.996 2013 aos.AcquireRef.started - AcquireRef[194]

Sat Mar 23 07:26:13.716 2013 aos.info - WFS: star found, estimated magnitude: 14.25 Sat Mar 23 07:27:03.955 2013 aos.AcquireRef.complete - AcquireRef[194] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:14.254 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6 Sat Mar 23 07:27:03.996 2013 aos.StartAO.started - StartAO[195]

Sat Mar 23 07:28:44.124 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 07:28:44.125 2013 aos.StartAO.complete - StartAO[195] complete

trac_num:20130323_072857

at Mar 23 07:30:05.977 2013 aos.Stop.complete - Stop[196] complete Sat Mar 23 07:30:05.990 2013 aos.info - Updated variable AOARB.L.LOOPON: 0

AO457

rot ang:16

Sat Mar 23 07:30:09.242 2013 aos.PresetAO.started - PresetAO[197] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-2.90381e-06,ro2:8.87761e-07,mag:15.7,cindex:2.76,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,windd

Sat Mar 23 07:33:26.028 2013 aos.AcquireRef.started - AcquireRef[198]

Sat Mar 23 07:33:55.303 2013 aos.AcquireRef.failed - AcquireRef[198] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

rot angle:-44

Sat Mar 23 07:34:46.489 2013 aos.PresetAO.started - PresetAO[200] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:7.57058e-07,ro2:-6.73659e-07,mag:15.7,cindex:2.76,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 23 07:35:46.043 2013 aos.AcquireRef.started - AcquireRef[201]

Sat Mar 23 07:36:18.246 2013 aos.AcquireRef.failed - AcquireRef[201] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

rot angle:72

Sat Mar 23 07:36:46.163 2013 aos.PresetAO.started - PresetAO[203] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.66689e-07,ro2:2.27017e-06,mag:15.7,cindex:2.76,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 07:38:22.208 2013 aos.AcquireRef.failed - AcquireRef[204] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

rot angle:189

Sat Mar 23 07:38:53.295 2013 aos.PresetAO.started - PresetAO[206] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-2.78348e-06,ro2:-8.28707e-07,mag:15.7,cindex:2.76,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 07:40:59.036 2013 aos.PresetAO.failed - PresetAO[206] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

Change star to get a different position for rotator.

AO458

Sat Mar 23 07:41:43.003 2013 aos.PresetAO.started - PresetAO[208] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-4.4079e-07,ro2:-4.80493e-07,mag:15.3,cindex:2.24,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 07:44:14.400 2013 aos.AcquireRef.started - AcquireRef[209]

Sat Mar 23 07:44:44.803 2013 aos.AcquireRef.failed - AcquireRef[209] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR Sat Mar 23 07:45:33.908 2013 aos.PresetAO.started - PresetAO[211] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.35373e-09,ro2:-5.74343e-07,mag:15.3,cindex:2.24,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 23 07:46:25.120 2013 aos.AcquireRef.started - AcquireRef[212]

the bayside not moving.it is about :-49.108, cuu:-2.71A

Sat Mar 23 07:47:09.510 2013 aos.PresetAO.started - PresetAO[214] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.91853e-06,ro2:-7.12859e-07,mag:15.3,cindex:2.24,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 07:47:54.565 2013 aos.AcquireRef.started - AcquireRef[215]
Sat Mar 23 07:48:24.664 2013 aos.AcquireRef.failed - AcquireRef[215] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

bayside stuck.

AO413

Sat Mar 23 07:48:58.520 2013 aos.PresetAO.started - PresetAO[217] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-2.60409e-07,ro2:2.4349e-07,mag:15.3,cindex:2.24,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 07:50:26.654 2013 aos.AcquireRef.started - AcquireRef[218]

stage power off/on bayside stage y not homming.

Changing the totator position to see if teh stage y can be hommed.

rot ang:320

the bayside y stage could be hommed.

AO458

ACE-TRACK Sat Mar 23 07:55:39.271 2013 aos.PresetAO.started - PresetAO[222] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.83335e-07,ro2:9.2328e-07,mag:15.3,cindex:2.24,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar Sat Mar 23 07:56:32.773 2013 aos.AcquireRef.started - AcquireRef[223]

Sat Mar 23 07:57:51.671 2013 aos.info - WFS: star found, estimated magnitude: 14.17 Sat Mar 23 07:58:41.113 2013 aos.AcquireRef.complete - AcquireRef[223] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:14.169 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6 Sat Mar 23 07:58:41.132 2013 aos.StartAO.started - StartAO[224]

Sat Mar 23 08:00:30.570 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 08:00:30.570 2013 aos.StartAO.complete - StartAO[224] complete

trac_num:20130323_080047 _080117 _080143

Sat Mar 23 08:17:45.949 2013 aos.PresetAO.started - PresetAO[234] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.38943e-06,ro2:6.31761e-08,mag:15.67,cindex:1.02,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 08:23:37.875 2013 aos.StartAO.failed - StartAO[236] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE

Sat Mar 23 08:24:25.061 2013 aos.PresetAO.started - PresetAO[238] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:3.35407e-07,ro2:5.90038e-07,mag:15.67,cindex:1.02,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)


variable seeing and with dim star the system can close the autogain procedures.

Sat Mar 23 08:53:37.390 2013 aos.PresetAO.started - PresetAO[250] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:4.27962e-07,ro2:-2.44793e-06,mag:15.27,cindex:1.22,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 08:59:31.760 2013 aos.info - COILS DISABLED Sat Mar 23 08:59:31.772 2013 aos.info - Updated variable adsecarb.L.FSM_STATE: Failure Sat Mar 23 08:59:31.784 2013 aos.error - Stopping WFS...

Changing to a bright star.

AO944

Sat Mar 23 09:07:17.371 2013 aos.PresetAO.started - PresetAO[258] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:2.21315e-07,ro2:-2.61847e-06,mag:10.7,cindex:2.4,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 23 09:09:14.254 2013 aos.AcquireRef.started - AcquireRef[259] Sat Mar 23 09:11:07.288 2013 aos.AcquireRef.complete - AcquireRef[259] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:625 mag:11.778 nBins:2 nModes:153 r0:0 snMode:0 strehl:0 ttMod:3 Sat Mar 23 09:11:07.307 2013 aos.StartAO.started - StartAO[260]

Failed during the autogain

WfsArbitrator_8534 |ERR| 6137|2013-03-23 09:11:58.818023| MAIN > Traceback (most recent call last):

seeing:1.7" variable 1.9"

Sat Mar 23 09:12:58.961 2013 aos.info - Bad seeing set ON Sat Mar 23 09:13:07.300 2013 aos.PresetAO.started - PresetAO[263] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:7.08825e-07,ro2:1.45523e-06,mag:10.7,cindex:2.4,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 09:17:02.952 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 09:17:02.953 2013 aos.StartAO.complete - StartAO[265] complete

tracknum:20130323_091711

skipping frame and shell RIP

Sat Mar 23 09:17:42.411 2013 aos.info - COILS DISABLED

same preset

rot ang:269

Sat Mar 23 09:24:07.798 2013 aos.PresetAO.started - PresetAO[269] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:6.49366e-07,ro2:-1.65095e-06,mag:10.7,cindex:2.4,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 09:26:06.427 2013 aos.PresetAO.failed - PresetAO[269] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

rot 270

Sat Mar 23 09:29:44.836 2013 aos.PresetAO.started - PresetAO[271] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:5.46155e-07,ro2:-8.3545e-07,mag:8.19,cindex:2.04,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 09:33:10.292 2013 aos.AcquireRef.started - AcquireRef[272]

bayside stage stuck Sat Mar 23 09:33:37.665 2013 aos.AcquireRef.failed - AcquireRef[272] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

rot ang:179

seeing variable:1.14"-1.2" Sat Mar 23 09:34:55.641 2013 aos.PresetAO.started - PresetAO[274] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.28451e-08,ro2:-4.58679e-07,mag:8.19,cindex:2.04,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 23 09:37:04.496 2013 aos.AcquireRef.started - AcquireRef[275]

Sat Mar 23 09:37:31.634 2013 aos.AcquireRef.failed - AcquireRef[275] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

same preset

Sat Mar 23 09:38:07.264 2013 aos.PresetAO.started - PresetAO[277] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-9.03724e-07,ro2:-3.25942e-07,mag:8.19,cindex:2.04,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 23 09:42:05.062 2013 aos.AcquireRef.started - AcquireRef[280] Sat Mar 23 09:43:43.027 2013 aos.info - WFS: star found, estimated magnitude: 9.57 Sat Mar 23 09:45:05.455 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 09:45:05.456 2013 aos.StartAO.complete - StartAO[281] complete

seeing:1.5"-up track_num:20130323_094531

skip frame.

Sat Mar 23 09:45:40.223 2013 aos.info - Maximum skip reached Sat Mar 23 09:45:40.236 2013 aos.error - Stopping WFS... Sat Mar 23 09:45:40.598 2013 aos.error - Stopping AdSec Sat Mar 23 09:45:40.610 2013 aos.info - Updated variable AOARB.L.LOOPON: 0 Sat Mar 23 09:45:41.793 2013 aos.info - Updated variable adsecarb.L.FSM_STATE: Failure Sat Mar 23 09:45:41.807 2013 aos.info - Updated variable AOARB.L.SL_READY: 0 Sat Mar 23 09:45:41.821 2013 aos.info - stopAo failed or syntax error occured

adsecarb.L |ERR| 31941|2013-03-23 09:45:41.786148| IDL > Command retu

Sat Mar 23 09:58:19.675 2013 aos.PresetAO.started - PresetAO[285] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.35434e-06,ro2:-5.59892e-07,mag:8.19,cindex:2.04,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 09:59:43.943 2013 aos.AcquireRef.started - AcquireRef[286]

Sat Mar 23 10:00:37.385 2013 aos.AcquireRef.failed - AcquireRef[286] failed - Timeout error on baysidex (-5001) TIMEOUT_ERROR

Sat Mar 23 10:01:18.682 2013 aos.PresetAO.started - PresetAO[288] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-4.80368e-06,ro2:-3.20121e-07,mag:8.19,cindex:2.04,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

WfsArbitrator_8534 |ERR| 6887|2013-03-23 10:01:30.550318| MAIN > AdOptError: Reading shared buffer masterdiagnostic.L:OPTLOOPBUF - code: -5001 TIMEOUT_ERROR

Stop/start slope computer and resend the bin from the CCD39 control

Sat Mar 23 10:09:43.647 2013 aos.PresetAO.started - PresetAO[290] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-4.47856e-07,ro2:-1.22456e-07,mag:8.19,cindex:2.04,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 10:11:12.055 2013 aos.AcquireRef.started - AcquireRef[291] Sat Mar 23 10:14:30.417 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 10:14:30.417 2013 aos.StartAO.complete - StartAO[292] complete

open loop maxim skip frame reached.

Sat Mar 23 10:15:41.734 2013 aos.info - COILS DISABLED Sat Mar 23 10:15:41.747 2013 aos.info - Updated variable adsecarb.L.FSM_STATE: Failure Sat Mar 23 10:15:41.761 2013 aos.error - Stopping WFS...

rot ang:150

Sat Mar 23 10:20:47.678 2013 aos.PresetAO.started - PresetAO[296] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-3.00031e-06,ro2:-6.14781e-08,mag:8.19,cindex:2.04,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 23 10:23:58.538 2013 aos.AcquireRef.started - AcquireRef[297]

Sat Mar 23 10:24:50.072 2013 aos.AcquireRef.failed - AcquireRef[297] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

rot ang:240

Sat Mar 23 10:26:15.571 2013 aos.PresetAO.started - PresetAO[299] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:5.38646e-07,ro2:1.22691e-06,mag:8.19,cindex:2.04,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar

Sat Mar 23 10:30:52.675 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 10:30:52.676 2013 aos.StartAO.complete - StartAO[301] complete

track_num:20130323_103124 _103226 _103244 _103358

Maxim skip frame. shell RIP

Sat Mar 23 10:36:05.582 2013 aos.info - COILS DISABLED Sat Mar 23 10:36:05.601 2013 aos.info - Updated variable adsecarb.L.FSM_STATE: Failure Sat Mar 23 10:36:05.616 2013 aos.error - Stopping WFS...

Sat Mar 23 10:36:26.101 2013 aos.info - Updated variable AOARB.L.LOOPON: 0 Sat Mar 23 10:36:26.608 2013 aos.info - Adsec 672b-left reset started.

remove act 005 from the position list.

rot angle:229

Sat Mar 23 10:58:26.734 2013 aos.PresetAO.started - PresetAO[306] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:2.83263e-07,ro2:-2.73555e-06,mag:8.19,cindex:2.04,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 11:00:33.877 2013 aos.AcquireRef.started - AcquireRef[307]

bayside stage y stuck.

Sat Mar 23 11:01:01.513 2013 aos.AcquireRef.failed - AcquireRef[307] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

Sat Mar 23 11:02:26.203 2013 aos.PresetAO.started - PresetAO[309] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.19958e-07,ro2:1.10007e-06,mag:8.19,cindex:2.04,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 11:03:15.230 2013 aos.AcquireRef.started - AcquireRef[310] Sat Mar 23 11:03:41.662 2013 aos.AcquireRef.failed - AcquireRef[310] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

bayside stage stuck

rot ang:309

Sat Mar 23 11:09:21.459 2013 aos.PresetAO.started - PresetAO[312] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:3.17878e-07,ro2:-1.97239e-06,mag:8.42,cindex:2.27,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 11:14:03.034 2013 aos.AcquireRef.started - AcquireRef[313]

Sat Mar 23 11:14:40.056 2013 aos.AcquireRef.failed - AcquireRef[313] failed - Timeout error on baysidex (-5001) TIMEOUT_ERROR

Sat Mar 23 11:15:41.285 2013 aos.PresetAO.started - PresetAO[315] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-7.62868e-08,ro2:-4.90527e-08,mag:8.42,cindex:2.27,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 23 11:16:24.186 2013 aos.AcquireRef.started - AcquireRef[316]

Sat Mar 23 11:19:37.179 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Mar 23 11:19:37.179 2013 aos.StartAO.complete - StartAO[317] complete

track_num:20130323_112012 _112044 _112059 _112129 10000 _112225 " _112304 "

Sat Mar 23 11:24:17.170 2013 aos.PresetAO.started - PresetAO[319] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:4.69082e-07,ro2:1.01298e-06,mag:8.42,cindex:2.27,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

preset failed from the TCS side. Tertiary

rot ang:298

Sat Mar 23 11:26:18.221 2013 aos.PresetAO.started - PresetAO[321] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:6.72977e-07,ro2:-1.74536e-06,mag:8.42,cindex:2.27,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Mar 23 11:27:59.095 2013 aos.AcquireRef.started - AcquireRef[322]

Sat Mar 23 11:28:41.518 2013 aos.AcquireRef.failed - AcquireRef[322] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

rot ang:260 Sat Mar 23 11:30:13.499 2013 aos.PresetAO.started - PresetAO[324] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-6.88674e-07,ro2:-1.64236e-06,mag:8.42,cindex:2.27,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan) Sat Mar 23 11:31:00.354 2013 aos.AcquireRef.started - AcquireRef[325]

bayside stage stuck Sat Mar 23 11:31:27.173 2013 aos.AcquireRef.failed - AcquireRef[325] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

STOP 11:39

TOO MANY FAILURES OF THE BAYSIDE STAGE AND THE SEEING IS GETTING WORTS

back to do some acquisition of active optics

-- JuanGuerra - 22 Mar 2013
Topic revision: r5 - 24 Mar 2013, JuanGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback