Summary

Testing on Sky the functionallity of the SX + FLAO at close loop. The on-sky test took the first half of the night and handover to LBTI. Due to a big temperature gradient, the AO system couldn't close the loop till the dome was thermalise. All the operations close loop through the IIF. Actuator misfunction and disabled. Put in the list for bad position. Act #373 Y Bayside stage Y showed a bad behaviour, reported to Arcetri. Offsets in X direction failed when the offsets is out of the patrol field and back in. REported to Arcetri.

Detail

* Ace preset ot a star 8 magnitude.

Sat Feb 23 02:22:20.622 2013 aos.PresetAO.started - PresetAO[392] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.20627e-08,ro2:2.02812e-06,mag:8.38,cindex:1.75,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Screenshot_ccd47ghost.png

 Stop observing. Problem with the primary temperature 

Sat Feb 23 02:49:51.111 2013 aos.PresetAO.started - PresetAO[395] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.55814e-07,ro2:-1.43363e-06,mag:8.38,cindex:1.75,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Feb 23 02:50:30.264 2013 aos.PresetAO.complete - PresetAO[395] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3

*Adjusting pointing with the same ACE star.

runao failure.

WfsArbitrator_1740 |ERR| 326|2013-02-23 03:04:06.993784| MAIN > Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE WfsArbitrator_1740 |ERR| 327|2013-02-23 03:04:06.993839| MAIN > Traceback (most recent call last): WfsArbitrator_1740 |ERR| 328|2013-02-23 03:04:06.993864| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/WfsArbScripts.py", line 2497, in arbFunc WfsArbitrator_1740 |ERR| 329|2013-02-23 03:04:06.993884| MAIN > errstr = func(*args) WfsArbitrator_1740 |ERR| 330|2013-02-23 03:04:06.993903| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/WfsArbScripts.py", line 1707, in optimizeGainInternal WfsArbitrator_1740 |ERR| 331|2013-02-23 03:04:06.993922| MAIN > a.doit( app.ccd39.xbin()) WfsArbitrator_1740 |ERR| 332|2013-02-23 03:04:06.993941| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/autogain.py", line 320, in doit WfsArbitrator_1740 |ERR| 333|2013-02-23 03:04:06.993961| MAIN > f, tmp1, ho1, tmp2 = self.optimize( 'step-1219453836'2181344atastep, tt, ho1, ho2, start, end, step, cycles, None, 'ho1', set=True, middle_ho=ho_middle) WfsArbitrator_1740 |ERR| 334|2013-02-23 03:04:06.993981| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/autogain.py", line 213, in optimize WfsArbitrator_1740 |ERR| 335|2013-02-23 03:04:06.994000| MAIN > self.acquire_sweep( gain_tt, gain_ho1, gain_ho2, middle_ho, self.gainpath, outfile_gains, outfile_slopes, hdr) WfsArbitrator_1740 |ERR| 336|2013-02-23 03:04:06.994019| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/autogain.py", line 189, in acquire_sweep WfsArbitrator_1740 |ERR| 337|2013-02-23 03:04:06.994038| MAIN > raise AdOptError( code = AOErrCode['IDL_SAFE_SKIP_ACTIVE'], errstr = 'Safe skip active - cannot proceed') WfsArbitrator_1740 |ERR| 338|2013-02-23 03:04:06.994057| MAIN > AdOptError: Safe skip active - cannot proceed - code: -10045 IDL_SAFE_SKIP_ACTIVE WfsArbitrator_1740 |DEB| 339|2013-02-23 03:04:06.994722| MAIN > arbFunc doStopLoop (, 'FLAOWFS', 'LUCIFER') WfsArbitrator_1740 |DEB| 340|2013-02-23 03:04:07.109142| MAIN > arbFunc doStopLoop done.

The loop didn't close we saw the inner rings pumping

*Sending another preset. Sat Feb 23 03:17:29.371 2013 aos.PresetAO.complete - PresetAO[406] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3

Failed during the Acquire reference star,

WfsArbitrator_1740 |ERR| 567|2013-02-23 03:21:58.514254| MAIN > Timeout error on baysidex (-5001) TIMEOUT_ERROR WfsArbitrator_1740 |ERR| 568|2013-02-23 03:21:58.514288| MAIN > Traceback (most recent call last): WfsArbitrator_1740 |ERR| 569|2013-02-23 03:21:58.514310| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/WfsArbScripts.py", line 2497, in arbFunc WfsArbitrator_1740 |ERR| 570|2013-02-23 03:21:58.514329| MAIN > errstr = func(*args) WfsArbitrator_1740 |ERR| 571|2013-02-23 03:21:58.514348| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/WfsArbScripts.py", line 1307, in doAcquireRef WfsArbitrator_1740 |ERR| 572|2013-02-23 03:21:58.514383| MAIN > acqRet = source_acq.acquire(app, TVavg = app._acquireRefSettings.TVavg, TVflux = app._acquireRefSettings.TVflux, fwhm = app._acquireRefSettings.seeing) WfsArbitrator_1740 |ERR| 573|2013-02-23 03:21:58.514403| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/source_acq.py", line 279, in acquire WfsArbitrator_1740 |ERR| 574|2013-02-23 03:21:58.514423| MAIN > app.stagex.waitTargetReached( moveTimeout) WfsArbitrator_1740 |ERR| 575|2013-02-23 03:21:58.514442| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/hwctrl/simplemotor.py", line 300, in waitTargetReached WfsArbitrator_1740 |ERR| 576|2013-02-23 03:21:58.514462| MAIN > raise AdOptError( AOErrCode['TIMEOUT_ERROR'], "Timeout error on " Kelf.name) WfsArbitrator_1740 |ERR| 577|2013-02-23 03:21:58.514481| MAIN > AdOptError: Timeout error on baysidex - code: -5001 TIMEOUT_ERROR

*New preset

Sat Feb 23 03:25:32.344 2013 aos.info - Updated variable AOARB.L.FSM_STATE: ReadyToAcquire Sat Feb 23 03:25:32.376 2013 aos.PresetAO.complete - PresetAO[409] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:2 nModes:153 r0:0 snMode:0 strehl:0 ttMod:3

Sat Feb 23 03:30:16.400 2013 aos.info - WFS: star found, estimated magnitude: 11.72

LOOP FAILURE JUST AFTER THE AUTOGAIN. WE ARE STILL SEEING THE INNER RINGS SHAPE.

Sat Feb 23 03:32:06.218 2013 aos.StartAO.complete - StartAO[411] complete Sat Feb 23 03:32:06.232 2013 aos.info - Updated variable AOARB.L.FSM_STATE: LoopClosed Sat Feb 23 03:32:06.725 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 03:32:08.731 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 03:32:10.737 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 03:32:12.363 2013 aos.info - Offload request processing Sat Feb 23 03:32:12.377 2013 aos.info - Offload disabled by fastdiagn Sat Feb 23 03:32:12.741 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 03:32:13.939 2013 aos.info - Maximum skip reached Sat Feb 23 03:32:13.958 2013 aos.error - Stopping WFS... Sat Feb 23 03:32:14.178 2013 aos.info - Updated variable wfsarb.L.FSM_STATE@M_FLAOWFS: AOSet Sat Feb 23 03:32:14.280 2013 aos.error - Stopping AdSec Sat Feb 23 03:32:14.294 2013 aos.info - Updated variable AOARB.L.LOOPON: 0

SEC DATA ACQUIRE_ 20130222_033208

*Preset

Sat Feb 23 03:42:05Sat Feb 23 03:42:05.879 2013 aos.PresetAO.complete - PresetAO[416] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:2 nModes:153 r0:0 snMode:0 strehl:0 ttMod:3.879 2013 aos.PresetAO.complete - PresetAO[416] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:2 nModes:153 r0:0 snMode:0 strehl:0 ttMod:3

ACQUIRE REFERENCE STAR FAILURE. TIME OUT ERROR FOR THE BAYSIDE STAGES.
Sat Feb 23 03:45:25.234 2013 aos.AcquireRef.failed - AcquireRef[417] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

WfsArbitrator_1740 |ERR| 861|2013-02-23 03:45:25.117967| MAIN > Timeout error on baysidey (-5001) TIMEOUT_ERROR WfsArbitrator_1740 |ERR| 862|2013-02-23 03:45:25.118003| MAIN > Traceback (most recent call last): WfsArbitrator_1740 |ERR| 863|2013-02-23 03:45:25.118024| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/WfsArbScripts.py", line 2497, in arbFunc WfsArbitrator_1740 |ERR| 864|2013-02-23 03:45:25.118043| MAIN > errstr = func(*args) WfsArbitrator_1740 |ERR| 865|2013-02-23 03:45:25.118062| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/WfsArbScripts.py", line 1307, in doAcquireRef WfsArbitrator_1740 |ERR| 866|2013-02-23 03:45:25.118082| MAIN > acqRet = source_acq.acquire(app, TVavg = app._acquireRefSettings.TVavg, TVflux = app._acquireRefSettings.TVflux, fwhm = app._acquireRefSettings.seeing) WfsArbitrator_1740 |ERR| 867|2013-02-23 03:45:25.118101| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/source_acq.py", line 280, in acquire WfsArbitrator_1740 |ERR| 868|2013-02-23 03:45:25.118120| MAIN > app.stagey.waitTargetReached( moveTimeout) WfsArbitrator_1740 |ERR| 869|2013-02-23 03:45:25.118139| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/hwctrl/simplemotor.py", line 300, in waitTargetReached WfsArbitrator_1740 |ERR| 870|2013-02-23 03:45:25.118159| MAIN > raise AdOptError( AOErrCode['TIMEOUT_ERROR'], "Timeout error on " Kelf.name) WfsArbitrator_1740 |ERR| 871|2013-02-23 03:45:25.118178| MAIN > AdOptError: Timeout error on baysidey - code: -5001 TIMEOUT_ERR

Sat Feb 23 03:46:23.106 2013 aos.PresetAO.started - PresetAO[419] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:4.65997e-08,ro2:2.94682e-06,mag:11.2,cindex:2.53,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

WfsArbitrator_1740 |ERR| 1005|2013-02-23 03:51:28.236181| MAIN > Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE WfsArbitrator_1740 |ERR| 1006|2013-02-23 03:51:28.236230| MAIN > Traceback (most recent call last): WfsArbitrator_1740 |ERR| 1007|2013-02-23 03:51:28.236260| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/WfsArbScripts.py", line 2497, in arbFunc WfsArbitrator_1740 |ERR| 1008|2013-02-23 03:51:28.236281| MAIN > errstr = func(*args) WfsArbitrator_1740 |ERR| 1009|2013-02-23 03:51:28.236300| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/WfsArbScripts.py", line 1707, in optimizeGainInternal WfsArbitrator_1740 |ERR| 1010|2013-02-23 03:51:28.236339| MAIN > a.doit( app.ccd39.xbin()) WfsArbitrator_1740 |ERR| 1011|2013-02-23 03:51:28.236360| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/autogain.py", line 299, in doit WfsArbitrator_1740 |ERR| 1012|2013-02-23 03:51:28.236380| MAIN > f, tt, tmp1, tmp2 = self.optimize( 'step-1219453836'2181344atastep, tt, ho1, ho2, start, end, step, cycles, None, 'tt', set=True, middle_ho=ho_middle) WfsArbitrator_1740 |ERR| 1013|2013-02-23 03:51:28.236399| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/autogain.py", line 213, in optimize WfsArbitrator_1740 |ERR| 1014|2013-02-23 03:51:28.236418| MAIN > self.acquire_sweep( gain_tt, gain_ho1, gain_ho2, middle_ho, self.gainpath, outfile_gains, outfile_slopes, hdr) WfsArbitrator_1740 |ERR| 1015|2013-02-23 03:51:28.236438| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/autogain.py", line 189, in acquire_sweep WfsArbitrator_1740 |ERR| 1016|2013-02-23 03:51:28.236457| MAIN > raise AdOptError( code = AOErrCode['IDL_SAFE_SKIP_ACTIVE'], errstr = 'Safe skip active - cannot proceed') WfsArbitrator_1740 |ERR| 1017|2013-02-23 03:51:28.236476| MAIN > AdOptError: Safe skip active - cannot proceed - code: -10045 IDL_SAFE_SKIP_ACTIVE WfsArbitrator_1740 |DEB| 1018|2013-02-23 03:51:28.237822| MAIN > arbFunc doStopLoop (, 'FLAOWFS', 'LUCIFER') WfsArbitrator_1740 |DEB| 1019|2013-02-23 03:51:28.352740| MAIN > arbFunc doStopLoop done.

BAD CONDITIONS....

*TEST TTM PRESET.

Sat Feb 23 03:56:01.568 2013 aos.PresetAO.started - PresetAO[423] (aomode:TTM-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.80465e-08,ro2:2.55153e-07,mag:11.2,cindex:2.53,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Feb 23 03:57:28.510 2013 aos.PresetAO.complete - PresetAO[423] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:0 nBins:4 nModes:5 r0:0 snMode:0 strehl:0 ttMod:6

FAILURE DURING THE ACQUIRE REFERENCE.

WfsArbitrator_1740 |ERR| 1103|2013-02-23 03:58:22.492997| MAIN > Timeout error on baysidey (-5001) TIMEOUT_ERROR WfsArbitrator_1740 |ERR| 1104|2013-02-23 03:58:22.493033| MAIN > Traceback (most recent call last): WfsArbitrator_1740 |ERR| 1105|2013-02-23 03:58:22.493054| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/WfsArbScripts.py", line 2497, in arbFunc WfsArbitrator_1740 |ERR| 1106|2013-02-23 03:58:22.493073| MAIN > errstr = func(*args) WfsArbitrator_1740 |ERR| 1107|2013-02-23 03:58:22.493092| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/WfsArbScripts.py", line 1307, in doAcquireRef WfsArbitrator_1740 |ERR| 1108|2013-02-23 03:58:22.493112| MAIN > acqRet = source_acq.acquire(app, TVavg = app._acquireRefSettings.TVavg, TVflux = app._acquireRefSettings.TVflux, fwhm = app._acquireRefSettings.seeing) WfsArbitrator_1740 |ERR| 1109|2013-02-23 03:58:22.493131| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/source_acq.py", line 280, in acquire WfsArbitrator_1740 |ERR| 1110|2013-02-23 03:58:22.493150| MAIN > app.stagey.waitTargetReached( moveTimeout) WfsArbitrator_1740 |ERR| 1111|2013-02-23 03:58:22.493169| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/hwctrl/simplemotor.py", line 300, in waitTargetReached WfsArbitrator_1740 |ERR| 1112|2013-02-23 03:58:22.493188| MAIN > raise AdOptError( AOErrCode['TIMEOUT_ERROR'], "Timeout error on " Kelf.name) WfsArbitrator_1740 |ERR| 1113|2013-02-23 03:58:22.493208| MAIN > AdOptError: Timeout error on baysidey - code: -5001 TIMEOUT_ERROR

*CHANGE ROTATION BY 90

Sat Feb 23 04:16:33.780 2013 aos.OffsetXY.started - OffsetXY[442] (ofsx:35.9379,ofsy:-1.67144e-08) Sat Feb 23 04:16:33.799 2013 aos.OffsetXY.failed - OffsetXY[442] failed - RETRY: Offset outside FoV limits. (-5002) VALUE_OUT_OF_RANGE_ERROR

*CHECK OFFSETS...

Sat Feb 23 04:17:17.114 2013 aos.Pause.started - Pause[443] Sat Feb 23 04:17:17.130 2013 aos.Pause.complete - Pause[443] complete Sat Feb 23 04:17:17.316 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 04:17:19.324 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 04:17:19.433 2013 aos.OffsetXY.started - OffsetXY[444] (ofsx:-7.12748e-07,ofsy:1.33679e-08) Sat Feb 23 04:17:19.453 2013 aos.OffsetXY.complete - OffsetXY[444] complete Sat Feb 23 04:17:21.332 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 04:17:23.340 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 04:17:25.347 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 04:17:27.356 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 04:17:28.310 2013 aos.Resume.started - Resume[445] Sat Feb 23 04:17:28.362 2013 aos.info - Updated variable adsecarb.L.FSM_STATE: AORunning Sat Feb 23 04:17:29.365 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 04:17:29.554 2013 aos.info - Updated variable wfsarb.L.FSM_STATE@M_FLAOWFS: LoopClosed Sat Feb 23 04:17:29.561 2013 aos.Resume.complete - Resume[445] complete Sat Feb 23 04:17:29.569 2013 aos.info - Updated variable AOARB.L.LOOPON: 1 Sat Feb 23 04:17:29.599 2013 aos.info - Updated variable AOARB.L.FSM_STATE: LoopClosed Sat Feb 23 04:17:30.100 2013 aos.info - Offload request processing Sat Feb 23 04:17:30.116 2013 aos.info - Offload over threshold Sat Feb 23 04:18:08.233 2013 aos.Pause.started - Pause[446] Sat Feb 23 04:18:08.515 2013 aos.info - Updated variable wfsarb.L.FSM_STATE@M_FLAOWFS: LoopPaused Sat Feb 23 04:18:08.535 2013 aos.info - Updated variable adsecarb.L.FSM_STATE: AOPause Sat Feb 23 04:18:08.537 2013 aos.Pause.complete - Pause[446] complete Sat Feb 23 04:18:08.549 2013 aos.info - Updated variable AOARB.L.LOOPON: 2 Sat Feb 23 04:18:08.578 2013 aos.info - Updated variable AOARB.L.FSM_STATE: LoopSuspended Sat Feb 23 04:18:09.523 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 04:18:10.202 2013 aos.info - Offload request processing Sat Feb 23 04:18:10.225 2013 aos.info - Offload disabled by fastdiagn Sat Feb 23 04:18:10.886 2013 aos.OffsetXY.started - OffsetXY[447] (ofsx:-71.8188,ofsy:-2.42887e-08) Sat Feb 23 04:18:10.904 2013 aos.OffsetXY.failed - OffsetXY[447] failed - OffsetXY out of range (max is 36.00 mm) Sat Feb 23 04:18:11.532 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp

Sat Feb 23 04:22:13.222 2013 aos.OffsetXY.started - OffsetXY[449] (ofsx:-71.8188,ofsy:-7.44086e-08) Sat Feb 23 04:22:13.241 2013 aos.OffsetXY.failed - OffsetXY[449] failed - OffsetXY out of range (max is 36.00 mm)

Sat Feb 23 04:23:00.235 2013 aos.OffsetXY.started - OffsetXY[451] (ofsx:-35.9151,ofsy:-3.00639e-08) Sat Feb 23 04:23:09.379 2013 aos.OffsetXY.complete - OffsetXY[451] complete Sat Feb 23 04:23:10.702 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 04:23:11.608 2013 aos.Resume.started - Resume[452]

*OFFSET 0/0 X=-75.9/Y--51.3

*10/0 ABSOLUTE Sat Feb 23 04:26:13.417 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 04:26:15.074 2013 aos.OffsetXY.started - OffsetXY[457] (ofsx:5.98365,ofsy:2.69607e-08)

*10/0 (ofsx:-5.71343e-07,ofsy:-2.64102e-08)

*20/0 Sat Feb 23 04:27:47.990 2013 aos.OffsetXY.started - OffsetXY[463] (ofsx:5.9837,ofsy:6.77697e-08)

*20/0 Sat Feb 23 04:28:16.346 2013 aos.OffsetXY.started - OffsetXY[466] (ofsx:3.95163e-06,ofsy:-1.49399e-08)

*0/0 Sat Feb 23 04:28:46.229 2013 aos.OffsetXY.started - OffsetXY[469] (ofsx:-11.9673,ofsy:-6.50824e-08)

*180/0 Sat Feb 23 04:29:21.677 2013 aos.OffsetXY.started - OffsetXY[472] (ofsx:107.757,ofsy:-2.27365e-08) Sat Feb 23 04:29:21.696 2013 aos.OffsetXY.failed - OffsetXY[472] failed - OffsetXY out of range (max is 36.00 mm)

*0/0 Sat Feb 23 04:29:49.138 2013 aos.OffsetXY.started - OffsetXY[474] (ofsx:5.88753e-07,ofsy:5.86068e-08)

*180/0

*120/0 Sat Feb 23 04:31:09.661 2013 aos.OffsetXY.started - OffsetXY[479] (ofsx:71.8188,ofsy:-3.52806e-08) Sat Feb 23 04:31:09.678 2013 aos.OffsetXY.failed - OffsetXY[479] failed - OffsetXY out of range (max is 36.00 mm)

*Y- AXIS

*0/10 Sat Feb 23 04:35:47.787 2013 aos.OffsetXY.started - OffsetXY[484] (ofsx:-2.72313e-06,ofsy:5.98365)

*0/0 Sat Feb 23 04:36:23.748 2013 aos.OffsetXY.started - OffsetXY[487] (ofsx:-1.07009e-06,ofsy:-5.98365)

*0/120 Sat Feb 23 04:37:11.411 2013 aos.OffsetXY.started - OffsetXY[490] (ofsx:3.25532e-06,ofsy:71.8188) Sat Feb 23 04:37:11.428 2013 aos.OffsetXY.failed - OffsetXY[490] failed - OffsetXY out of range (max is 36.00 mm)

*0/0 Sat Feb 23 04:37:40.179 2013 aos.OffsetXY.started - OffsetXY[492] (ofsx:6.89969e-08,ofsy:3.65525e-08) Sat Feb 23 04:37:40.210 2013 aos.OffsetXY.complete - OffsetXY[492] complete

*0/60

Sat Feb 23 04:38:12.949 2013 aos.OffsetXY.started - OffsetXY[495] (ofsx:1.04648e-06,ofsy:35.9037)

*0/120

Sat Feb 23 04:38:43.766 2013 aos.OffsetXY.started - OffsetXY[498] (ofsx:-9.39661e-07,ofsy:35.9151) Sat Feb 23 04:38:43.787 2013 aos.OffsetXY.failed - OffsetXY[498] failed - RETRY: Offset outside FoV limits. (-5002) VALUE_OUT_OF_RANGE_ERROR

*0/0 Sat Feb 23 04:39:46.637 2013 aos.warning - Cannot write TV image file /lbt/tmpdata/aos/AOSLtv.tmp Sat Feb 23 04:39:47.037 2013 aos.OffsetXY.started - OffsetXY[500] (ofsx:-3.0354e-06,ofsy:-35.9037)

*0/120 Sat Feb 23 04:40:39.755 2013 aos.OffsetXY.started - OffsetXY[503] (ofsx:2.89822e-06,ofsy:71.8188) Sat Feb 23 04:40:39.789 2013 aos.OffsetXY.failed - OffsetXY[503] failed - OffsetXY out of range (max is 36.00 mm)

*0/60 Sat Feb 23 04:41:31.429 2013 aos.OffsetXY.started - OffsetXY[505] (ofsx:-8.94784e-08,ofsy:35.9037)

X-AXIS

*0/0

*180/0 Sat Feb 23 04:42:49.465 2013 aos.OffsetXY.started - OffsetXY[511] (ofsx:107.757,ofsy:2.92311e-08) Sat Feb 23 04:42:49.486 2013 aos.OffsetXY.failed - OffsetXY[511] failed - OffsetXY out of range (max is 36.00 mm)

*0/0 Sat Feb 23 04:43:29.649 2013 aos.OffsetXY.started - OffsetXY[513] (ofsx:-8.59804e-07,ofsy:-5.90458e-10) Sat Feb 23 04:43:29.670 2013 aos.OffsetXY.complete - OffsetXY[513] complete

*180/0 at Feb 23 04:44:03.457 2013 aos.OffsetXY.started - OffsetXY[516] (ofsx:107.757,ofsy:-2.43437e-08) Sat Feb 23 04:44:03.475 2013 aos.OffsetXY.failed - OffsetXY[516] failed - OffsetXY out of range (max is 36.00 mm)

*120/0 Sat Feb 23 04:44:30.031 2013 aos.OffsetXY.started - OffsetXY[518] (ofsx:71.8188,ofsy:4.1092e-08) Sat Feb 23 04:44:30.057 2013 aos.OffsetXY.failed - OffsetXY[518] failed - OffsetXY out of range (max is 36.00 mm)

*0/0 Sat Feb 23 04:46:04.620 2013 aos.OffsetXY.started - OffsetXY[520] (ofsx:3.21832e-06,ofsy:-9.0088e-09) Sat Feb 23 04:46:04.640 2013 aos.Off

setXY.complete - OffsetXY[520] complete

*180/0 Sat Feb 23 04:51:01.894 2013 aos.OffsetXY.started - OffsetXY[533] (ofsx:107.757,ofsy:5.34925e-08) Sat Feb 23 04:51:01.910 2013 aos.OffsetXY.failed - OffsetXY[533] failed - OffsetXY out of range (max is 36.00 mm)

*60/0 Sat Feb 23 04:51:33.071 2013 aos.OffsetXY.started - OffsetXY[535] (ofsx:35.9037,ofsy:7.56455e-08)

*100/0 X=-16.1 Sat Feb 23 04:53:27.037 2013 aos.OffsetXY.started - OffsetXY[538] (ofsx:23.9414,ofsy:-3.92896e-08)

*120/0 X=-4 Sat Feb 23 04:54:00.825 2013 aos.OffsetXY.started - OffsetXY[541] (ofsx:11.9737,ofsy:-5.25317e-08)

*0/0

Sat Feb 23 04:55:22.273 2013 aos.OffsetXY.started - OffsetXY[544] (ofsx:-71.8188,ofsy:4.11812e-08) Sat Feb 23 04:55:22.290 2013 aos.OffsetXY.failed - OffsetXY[544] failed - OffsetXY out of range (max is 36.00 mm)

*20/0 Sat Feb 23 04:56:08.805 2013 aos.OffsetXY.started - OffsetXY[546] (ofsx:-59.8515,ofsy:1.41469e-08) Sat Feb 23 04:56:08.834 2013 aos.OffsetXY.failed - OffsetXY[546] failed - OffsetXY out of range (max is 36.00 mm)

SHELL RIP

Sat Feb 23 04:56:55.439 2013 aos.Resume.failed - Resume[549] failed - Command timeout - -13107: Arbitrator interface generic error

adsec.L |ERR| 43052|2013-02-23 04:57:38.996685| MAIN > Error checking SIGGEN for Crate#00 in Nios version. adsec.L |ERR| 43053|2013-02-23 04:57:38.996925| MAIN > Error checking BCU for Crate#01 in Logic version. adsec.L |ERR| 43054|2013-02-23 04:57:38.997018| MAIN > Error checking ACCELEROMETER for Crate#01 in Nios version. adsec.L |ERR| 43055|2013-02-23 04:57:38.997156| MAIN > Error checking DSpBoard#04 for Crate#01 in Nios version. adsec.L |ERR| 43056|2013-02-23 04:57:38.997356| MAIN > Error checking SIGGEN for Crate#02 in Nios version. adsec.L |ERR| 43057|2013-02-23 04:57:38.997602| MAIN > Error checking ACCELEROMETER for Crate#03 in Nios version. adsec.L |ERR| 43058|2013-02-23 04:57:38.997845| MAIN > Error checking SIGGEN for Crate#04 in Nios version. adsec.L |ERR| 43059|2013-02-23 04:57:38.998089| MAIN > Error checking ACCELEROMETER for Crate#05 in Nios version. adsec.L |INF| 43060|2013-02-23 04:57:38.998486| MAIN > Starting the ACCELEROMETER program...

BIN 2 WORKS #####

Sat Feb 23 05:05:35.990 2013 aos.PresetAO.started - PresetAO[555] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-9.78954e-07,ro2:1.87449e-08,mag:11.2,cindex:2.53,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

SAVE DATA 20130223_051057 _051120 _051147 _051214

Sat Feb 23 05:10:39.256 2013 aos.info - Updated variable AOARB.L.FSM_STATE: LoopClosed Sat Feb 23 05:12:45.823 2013 aos.info - Maximum skip reached Sat Feb 23 05:12:45.839 2013 aos.error - Stopping WFS...

Sat Feb 23 05:31:58.949 2013 aos.PresetAO.started - PresetAO[564] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.86513e-06,ro2:6.87141e-07,mag:9.07,cindex:2.13,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

WfsArbitrator_1740 |ERR| 2042|2013-02-23 05:32:16.713786| MAIN > AdOptError: Reading shared buffer masterdiagnostic.L:OPTLOOPBUF - code: -5001 TIMEOUT_ERROR

Sat Feb 23 05:32:16.771 2013 aos.PresetAO.failed - PresetAO[564] failed - Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR

RECOVERING STOP/START THE SLOPE COMPUTER AND CHANGING BINNING IN THE CCD39. 

Sat Feb 23 05:35:52.081 2013 aos.PresetAO.started - PresetAO[566] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.27222e-06,ro2:6.21652e-08,mag:9.07,cindex:2.13,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Feb 23 05:43:03.595 2013 aos.info - COILS DISABLED

adsecarb.L |WAR| 4810|2013-02-23 05:40:34.056901| MAIN > Skip frame detected! adsecarb.L |WAR| 4811|2013-02-23 05:40:35.086841| MAIN > Skip frame detected! adsec.L |WAR| 43810|2013-02-23 05:42:53.060689| MAIN > SIGGEN request found: calling multiple sendMultiBcuCommand... adsec.L |WAR| 43811|2013-02-23 05:42:53.063967| MAIN > SIGGEN request found: calling multiple sendMultiBcuCommand... adsecarb.L |INF| 4812|2013-02-23 05:42:53.045036| COMMANDHANDLER > FSM (status: AORunning) has received command 2024 (Save status) adsecarb.L |INF| 4813|2013-02-23 05:42:54.012824| COMMANDHANDLER > Command Save status (code 2024) successfully completed adsecarb.L |WAR| 4814|2013-02-23 05:43:02.260006| MAIN > Skip frame detected! adsecarb.L |WAR| 4815|2013-02-23 05:43:03.327458| MAIN > Skip frame detected! adsecarb.L |ERR| 4816|2013-02-23 05:43:03.594569| ALERTHANDLER > Received an ERROR alert! Forcing Failure state. adsecarb.L |ERR| 4817|2013-02-23 05:43:03.594655| ALERTHANDLER > Alert message: COILS DISABLED from housekeeper.L adsecarb.L |INF| 4818|2013-02-23 05:43:03.595747| COMMANDHANDLER > FSM (status: Failure) has received command 2029 (TTOffload)

DATA SAVED 20130223_054253

FAILURE OF THE SECONDARY TWO ACTUATORS JUMPING #373 AND #374

The ASM is going from failure state after a SET commad. This has been done two times. Sat Feb 23 05:49:52 2013

Sat Feb 23 05:53:23.277 2013 aos.PresetAO.started - PresetAO[572] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:7.34734e-07,ro2:1.50715e-07,mag:9.07,cindex:2.13,elev:nan,rotang:nan,gravang:nan,r0:5,skybrgt:nan,windspeed:nan,winddir:nan) Sat Feb 23 05:55:04.284 2013 aos.info - Bad seeing set OFF Sat Feb 23 05:55:51.945 2013 aos.AcquireRef.started - AcquireRef[573]

Sat Feb 23 05:58:04.640 2013 aos.info - COILS DISABLED

jump actuators #373,#374.

*removing the actuator form the list; doing a power on from adseceng

adsecarb.L |ERR| 95|2013-02-23 06:21:03.705504| IDL > Command returns error : Value is out of range adsecarb.L |INF| 96|2013-02-23 06:21:03.705731| COMMANDHANDLER > Command execution failed: Fsm forced to Failure

Problem came from the file elect.txt one line in the comments it wasn't commented... !!!! WARNING !!!!
Line comented and the secpondary was power on adn set without any failure.

Sat Feb 23 06:40:36.238 2013 aos.PresetAO.started - PresetAO[584] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:3.41822e-06,ro2:3.61899e-07,mag:9.07,cindex:2.13,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Feb 23 06:49:11.596 2013 aos.info - COILS DISABLED

Sat Feb 23 06:57:44.598 2013 aos.PresetAO.started - PresetAO[589] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-2.56249e-06,ro2:1.02509e-07,mag:9.07,cindex:2.13,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

FAILURE DURING THE ACQ REF. Sat Feb 23 07:00:16.480 2013 aos.AcquireRef.failed - AcquireRef[590] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

Sat Feb 23 07:01:27.287 2013 aos.PresetAO.started - PresetAO[592] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-5.03727e-07,ro2:1.29379e-07,mag:9.07,cindex:2.13,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Feb 23 07:03:38.628 2013 aos.AcquireRef.failed - AcquireRef[593] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR

Sat Feb 23 07:04:40.357 2013 aos.PresetAO.started - PresetAO[595] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.37832e-06,ro2:6.57626e-08,mag:9.07,cindex:2.13,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

Sat Feb 23 07:06:11.355 2013 aos.AcquireRef.failed - AcquireRef[596] failed - Timeout error on baysidex (-5001) TIMEOUT_ERROR

Sat Feb 23 07:08:58.715 2013 aos.PresetAO.started - PresetAO[599] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-2.14183e-06,ro2:2.6295e-07,mag:9.07,cindex:2.13,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)

shell rip showing the heli shape..
screenshot_badcommand.png

-- JuanGuerra - 04 Mar 2013