UT 20120919 AO#2 Commissioning
Observer: Buzoni,L, Esposito, S. (INAF)
Telescope Operator: Steve A..(LBTO)
Additional AO Support: JCGuerra (LBTO)
Telescope Support: Kevin. N (LBTO)
Instrument Support: Tim. S (LBTO)
Summary
- Lost elevation telemetry three times at beginning of the night. This cause the shell to RIP. After restart the AOS, MCS and MCSPU, we didn't get the problem.
- Test of the new WFS software and failed. Back to original software and later with Alfio install the new software.The new software get a better estimation of the reference star.
- Acquisition of the data with the Tree-House ON/OFF.
- Variable and medium seeing: 1"-1.8"
- Acquisition of data for: BIN2,1kHz and 600Hz. BIN 3@200Hz.
- The GCS system was hung two times and the restart of the GCS system was needed to restore the observation.
- Debug some errors in the new code.
Details
Start 1:42
- Checking the collimation and pointing nearby AO649
Thu Sep 20 01:44:26.286 2012 aos.warning - Variable mcs.elDrive.position expired
Thu Sep 20 01:44:27.204 2012 aos.info - Updated variable adsecarb.L.ELEV_UPD: 0
SHELL RIP. Loosing elevation telemetry
.
Restart the AOS SUBSYSTEM LEFT.
adsec.L |ERR| 2018|2012-09-20 01:49:17.696630| ADAM-MODBUS > [TcpReceiveException] Error receiving data (errno=4 ), socket closed. (code -15003)
TcpConnection receive error File
TcpConnection.cpp line 130
adsecarb.L |ERR| 285|2012-09-20 01:49:17.172518| MAIN > Elevation not available! Resting the shell.
adsec.L |ERR| 2018|2012-09-20 01:49:17.696630| ADAM-MODBUS > [TcpReceiveException] Error receiving data (errno=4 ), socket closed. (code -15003)
TcpConnection receive error File
TcpConnection.cpp line 130
adsec.L |INF| 2019|2012-09-20 01:49:17.696711| MAIN > adamModbusReadOutput_wrap found TCP connection not initialized ...
adsec.L |INF| 2020|2012-09-20 01:49:17.696803| TCPCONNECTION > Creating
TcpConnection to 192.168.13.150:502
adsec.L |INF| 2021|2012-09-20 01:49:17.701956| TCPCONNECTION >
TcpConnection succesfully created!
adsec.L |INF| 2022|2012-09-20 01:49:17.701982| ADAM-MODBUS > Created TCP connection with timeout 1000 ms
adsec.L |INF| 2023|2012-09-20 01:49:17.750242| ADAM-MODBUS >
AdamModbus:
SetMultiCoils(97)
adsec.L |INF| 2024|2012-09-20 01:49:17.817433| MAIN > Coils disabled. Cleaning currents
adsecarb.L |ERR| 285|2012-09-20 01:49:17.172518| MAIN > Elevation not available! Resting the shell.
adsecarb.L |INF| 286|2012-09-20 01:49:17.394095| COMMANDHANDLER > forceRest(): disabling coils
ASM_DX:Thu Sep 20 01:44:26.851 2012 aos.warning - Variable mcs.elDrive.position expired
ASM_DX:Thu Sep 20 01:52:36.988 2012 aos.warning - Variable mcs.elDrive.position expired
Call software group (Tom Sargent.
Restart MCS and MCSPU
Note added to the issue track.
IDL> iif_preset,ao649,mode=ace,gs=10,rs=0,pa=0,ND=4
# Target star: 0 AO649
18:15:28.979 +20:15:49.88 RADEC 2000.0 J2000 4.6 -6.3 7.40 R 1.99 B_V 1.65
# Guide star: 10
18:15:33.553 +20:18:23.38 RADEC 2000.0 J2000 14.0 12.0 11.35 R 1.81 B_V 0.63
# AO Reference star: 0
18:15:28.979 +20:15:49.88 RADEC 2000.0 J2000 4.6 -6.3 11.40 R 1.99 B_V 1.65
preset, AO649, MODE=ACE, GS=10, RS=0
Thu Sep 20 02:05:21.951 2012 aos.PresetAO.started -
PresetAO[9] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.21729e-07,ro2:6.86147e-07,mag:11.4,cindex:1.99,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 02:05:22.002 2012 aos.info - WFS source set to: FLAOWFS
WFS OFFLINE
Debugging the new acquisition and magnitude estimation procedure.
2:13
Rest shell
2:14 BACK TO THE ORIGINAL WFS SOFTWARE
IDL> iif_preset,ao649,mode=ace,gs=10,rs=0,pa=0
# Target star: 0 AO649
18:15:28.979 +20:15:49.88 RADEC 2000.0 J2000 4.6 -6.3 7.40 R 1.99 B_V 1.65
# Guide star: 10
18:15:33.553 +20:18:23.38 RADEC 2000.0 J2000 14.0 12.0 11.35 R 1.81 B_V 0.63
# AO Reference star: 0
18:15:28.979 +20:15:49.88 RADEC 2000.0 J2000 4.6 -6.3 7.40 R 1.99 B_V 1.65
preset, AO649, MODE=ACE, GS=10, RS=0
Thu Sep 20 02:21:32.703 2012 aos.PresetAO.started -
PresetAO[16] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.38848e-06,ro2:5.3594e-08,mag:7.4,cindex:1.99,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 02:21:32.753 2012 aos.info - WFS source set to: FLAOWFS
SKIP during the optimize gain.
Thu Sep 20 02:25:28.854 2012 aos.StartAO.failed -
StartAO[18] failed - wfsarb:Illegal command for state AOSet (
OptimizeGain)
IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] =
RunAO result status: Error
err = Resmsg[1] =
AcquireRef[17] complete - dx:-0.618 dy:-0.966 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:8.501 nBins:1 nModes:500 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = wfsarb:Illegal command for state AOSet (
OptimizeGain)
err = Resmsg[3] =
StartAO[18] failed - wfsarb:Illegal command for state AOSet (
OptimizeGain)
2:26 SEEING: 1.1"
2:35. SEEING:0.98"
MANUAL CLOSE LOOP.
SKIP+RIP.
Thu Sep 20 02:38:43.485 2012 aos.warning - Variable mcs.elDrive.position expired
Thu Sep 20 02:38:43.740 2012 aos.info - Updated variable adsecarb.L.ELEV_UPD: 0
Thu Sep 20 02:38:44.395 2012 aos.info - rest failed or syntax error occured
IDL> iif_preset,ao649,mode=ace,gs=10,rs=0,pa=0
# Target star: 0 AO649
18:15:28.979 +20:15:49.88 RADEC 2000.0 J2000 4.6 -6.3 7.40 R 1.99 B_V 1.65
# Guide star: 10
18:15:33.553 +20:18:23.38 RADEC 2000.0 J2000 14.0 12.0 11.35 R 1.81 B_V 0.63
# AO Reference star: 0
18:15:28.979 +20:15:49.88 RADEC 2000.0 J2000 4.6 -6.3 7.40 R 1.99 B_V 1.65
preset, AO649, MODE=ACE, GS=10, RS=0
Thu Sep 20 02:43:15.345 2012 aos.PresetAO.started -
PresetAO[22] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:4.68479e-08,ro2:-3.56273e-08,mag:7.4,cindex:1.99,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 02:43:15.396 2012 aos.info - WFS source set to: FLAOWFS
2:45. SEEING: 0.92"
SKIP during close loop.
MANUAL CLOSE LOOP
THE AOS IS SENDING OFFLOAD COMMANDS STARTING FROM 2:43 TILL 2:53 THE LOG SYSTEM DIDN'T REPORT ANY UPDATE OF THE OFFLOAD COMMANDS. LOOKING THE PSF LOG VIEWER, THE LOG WAS STUCK AND THE SAME WITH THE OTHER TELESCOPE SYSTEMS.
SKIP with 500 modes, a run tested to check the robutness of the autogain when the ASM has a big tilt. Tilt in this case was 10nm PV
Thu Sep 20 03:09:22.186 2012 aos.info - Maximum skip reached
3:14...mag:8.3. IDL> iif_preset,ao724,mode=active,gs=8,pa=0
# Target star: 0 AO724
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
# Guide star: 8
21:04:39.545 +37:11:08.75 RADEC 2000.0 J2000 0.0 0.0 14.88 R 2.43 B_V 0.63
preset, AO724, MODE=ACTIVE, GS=8
Check pointing and collimation
IDL> iif_preset,ao724,mode=ace,gs=8,rs=0,pa=0
# Target star: 0 AO724
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
# Guide star: 8
21:04:39.545 +37:11:08.75 RADEC 2000.0 J2000 0.0 0.0 14.88 R 2.43 B_V 0.63
# AO Reference star: 0
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
preset, AO724, MODE=ACE, GS=8, RS=0
Thu Sep 20 03:19:55.838 2012 aos.PresetAO.started -
PresetAO[28] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.13719e-07,ro2:-1.54267e-08,mag:8.27,cindex:1.45,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 03:19:55.889 2012 aos.info - WFS source set to: FLAOWFS
3:25. SEEING:1.45"
SKIP, and we can see that the pupil has lost a border.
MANUAL CLOSE LOOP.
SKIP after the optimize gain
MANUAL CLOSE LOOP.
3:38 SEEING:1.35"
PROBLEM WITH THE PUPIL DIMENSION. POSSIBLE THAT THE PUPIL AND RECONSTRUCTOR FOR BIN 2 HAVE TO BE REACQUIRED. WE HAVE TO SUM THE EFFECT OF THE BAD SEEING.
screenshot, effect of loosing some of the pupil
IDL> iif_preset,ao724,mode=ace,gs=8,rs=0,pa=0
# Target star: 0 AO724
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
# Guide star: 8
21:04:39.545 +37:11:08.75 RADEC 2000.0 J2000 0.0 0.0 14.88 R 2.43 B_V 0.63
# AO Reference star: 0
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
preset, AO724, MODE=ACE, GS=8, RS=0
Thu Sep 20 03:48:27.524 2012 aos.PresetAO.started -
PresetAO[32] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-3.72885e-06,ro2:6.31128e-06,mag:8.27,cindex:1.45,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 03:48:27.575 2012 aos.info - WFS source set to: FLAOWFS
Test with the Bin 2 at the same star
4:07 SEEING:1.1"
Test with the Bin 2 at the same star
Thu Sep 20 04:11:03.899 2012 aos.PresetAO.started -
PresetAO[43] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.6551e-07,ro2:5.76025e-08,mag:8.27,cindex:1.45,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 04:11:03.950 2012 aos.info - WFS source set to: FLAOWFS
Changed the hot spot to acquire the star.
4:12. SEEING:1.5"
SKIP, during the optimize gain. This time the wfs loaded the bin 1.(Correct)
Resend the preset and close the loop manually.
SKIP during the close loop
4:23 SEEING:1.2"
4:28 SEEING:1.6"
SKIP DURING THE CLOSE LOOP
Thu Sep 20 04:34:31.430 2012 aos.info - Maximum skip reached
Thu Sep 20 04:34:31.481 2012 aos.error - Stopping WFS...
The filter wheel2 is shwong problem in the positions. after a power cycle off the filter wheel, the filter wheel came up with a wrong positioning after the homing.
4:40 *POWER OFF AND SOFTWARE OF THE WFS.*
IDL> iif_preset,ao724,mode=ace,gs=8,rs=0,pa=0
# Target star: 0 AO724
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
# Guide star: 8
21:04:39.545 +37:11:08.75 RADEC 2000.0 J2000 0.0 0.0 14.88 R 2.43 B_V 0.63
# AO Reference star: 0
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
preset, AO724, MODE=ACE, GS=8, RS=0
Thu Sep 20 04:46:33.334 2012 aos.PresetAO.started -
PresetAO[50] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:2.04545e-08,ro2:1.23553e-07,mag:8.27,cindex:1.45,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 04:46:33.384 2012 aos.info - WFS source set to: FLAOWFS
the system restart ok.
Thu Sep 20 04:50:44.848 2012 aos.StartAO.failed -
StartAO[52] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
===> Error in irc_runao
err = Resmsg[0] =
RunAO result status: Error
err = Resmsg[1] =
AcquireRef[51] complete - dx:-0.893 dy:-1.51 slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:9.87 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
err = Resmsg[3] =
StartAO[52] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
SKIP during the autogain
4:52. SEEING:1.4"
MANUAL CLOSE LOOP AND TEST OF BIN 1.
DL> iif_preset,ao724,mode=ace,gs=8,rs=0,pa=0
# Target star: 0 AO724
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
# Guide star: 8
21:04:39.545 +37:11:08.75 RADEC 2000.0 J2000 0.0 0.0 14.88 R 2.43 B_V 0.63
# AO Reference star: 0
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
preset, AO724, MODE=ACE, GS=8, RS=0
5:00. TEST OF TREE-HOUSE ON/OFF. BIN 1, 990 HZ.
Acquire measurements
Thu Sep 20 05:25:22.574 2012 aos.PresetAO.started -
PresetAO[69] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-3.70427e-09,ro2:-1.95436e-08,mag:8.27,cindex:1.45,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 05:25:22.625 2012 aos.info - WFS source set to: FLAOWFS
Thu Sep 20 05:25:36.317 2012 aos.PresetAO.failed -
PresetAO[69] failed - Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR
===> Error in irc_presetTelescope
err = Resmsg[0] =
PresetTelescope result status: Error err = Resmsg[1] = Stop[68] complete
err = Resmsg[2] = Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR
err = Resmsg[3] =
PresetAO[69] failed - Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR
CCD39 NOT LIVE
preset resent.
Thu Sep 20 05:27:47.716 2012 aos.PresetAO.started -
PresetAO[71] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:8.44248e-08,ro2:2.9923e-08,mag:8.27,cindex:1.45,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 05:27:47.767 2012 aos.info - WFS source set to: FLAOWFS
5:34. SEEING:1.1"
Acquire measurements
5:53.SEEING:1.05"
5:55 Change of the WFS software to the new version. Alfio from Arcetri.
IDL> iif_preset,ao724,mode=ace,gs=8,rs=0,pa=0
# Target star: 0 AO724
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
# Guide star: 8
21:04:39.545 +37:11:08.75 RADEC 2000.0 J2000 0.0 0.0 14.88 R 2.43 B_V 0.63
# AO Reference star: 0
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
preset, AO724, MODE=ACE, GS=8, RS=0
Thu Sep 20 06:04:12.074 2012 aos.PresetAO.started -
PresetAO[92] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:3.44873e-07,ro2:2.99587e-09,mag:8.27,cindex:1.45,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 06:04:12.125 2012 aos.info - WFS source set to: FLAOWFS
Thu Sep 20 06:08:33.995 2012 aos.info - Maximum skip reached
Thu Sep 20 06:08:34.046 2012 aos.error - Stopping WFS...
IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] =
RunAO result status: Error err = Resmsg[1] = err = Resmsg[2] =
AcquireRef[93] failed
<SKIP+RIP. during the acquire reference star.>
6:10. SEEING:1.13"
Resend preset.
Thu Sep 20 06:12:12.999 2012 aos.PresetAO.started -
PresetAO[96] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:7.15142e-07,ro2:-3.75752e-08,mag:8.27,cindex:1.45,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 06:12:13.050 2012 aos.info - WFS source set to: FLAOWFS
6:22. Check Pointing.
IDL> iif_preset,ao724,mode=ace,gs=8,rs=0,pa=0
# Target star: 0 AO724
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
# Guide star: 8
21:04:39.545 +37:11:08.75 RADEC 2000.0 J2000 0.0 0.0 14.88 R 2.43 B_V 0.63
# AO Reference star: 0
21:04:40.778 +37:09:47.26 RADEC 2000.0 J2000 14.2 3.2 8.27 R 1.45 B_V 1.65
preset, AO724, MODE=ACE, GS=8, RS=0
Thu Sep 20 06:24:16.725 2012 aos.PresetAO.started -
PresetAO[102] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.5618e-06,ro2:-8.87016e-08,mag:8.27,cindex:1.45,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 06:24:16.776 2012 aos.info - WFS source set to: FLAOWFS
IDL> iif_preset,ao1063,mode=ace,gs=1,rs=0,pa=0
# Target star: 0 AO1063
23:54:10.044 +23:11:55.37 RADEC 2000.0 J2000 89.8 -260.3 11.20 R 1.91 B_V 1.65
# Guide star: 1
23:54:15.393 +23:12:37.43 RADEC 2000.0 J2000 6.0 -6.0 11.46 R 1.90 B_V 0.63
# AO Reference star: 0
23:54:10.044 +23:11:55.37 RADEC 2000.0 J2000 89.8 -260.3 11.20 R 1.91 B_V 1.65
preset, AO1063, MODE=ACE, GS=1, RS=0
Thu Sep 20 06:37:28.621 2012 aos.PresetAO.started -
PresetAO[109] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:2.41542e-06,ro2:6.79024e-07,mag:11.2,cindex:1.91,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 06:37:28.671 2012 aos.info - WFS source set to: FLAOWFS
Check Pointing
IDL> iif_preset,ao1063,mode=ace,gs=1,rs=0,pa=0
# Target star: 0 AO1063
23:54:10.044 +23:11:55.37 RADEC 2000.0 J2000 89.8 -260.3 11.20 R 1.91 B_V 1.65
# Guide star: 1
23:54:15.393 +23:12:37.43 RADEC 2000.0 J2000 6.0 -6.0 11.46 R 1.90 B_V 0.63
# AO Reference star: 0
23:54:10.044 +23:11:55.37 RADEC 2000.0 J2000 89.8 -260.3 11.20 R 1.91 B_V 1.65
preset, AO1063, MODE=ACE, GS=1, RS=0
Thu Sep 20 06:43:35.955 2012 aos.PresetAO.started -
PresetAO[112] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:4.19539e-06,ro2:1.47146e-07,mag:11.2,cindex:1.91,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 06:43:36.005 2012 aos.info - WFS source set to: FLAOWFS
Debugging
Resend the preset.
Thu Sep 20 06:50:45.969 2012 aos.PresetAO.started -
PresetAO[117] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-2.96185e-06,ro2:-4.99508e-07,mag:11.2,cindex:1.91,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 06:50:46.020 2012 aos.info - WFS source set to: FLAOWFS
Debugging
Same preset
IDL> iif_preset,ao1063,mode=ace,gs=1,rs=0,pa=0,/ND
# Target star: 0 AO1063
23:54:10.044 +23:11:55.37 RADEC 2000.0 J2000 89.8 -260.3 11.20 R 1.91 B_V 1.65
# Guide star: 1
23:54:15.393 +23:12:37.43 RADEC 2000.0 J2000 6.0 -6.0 11.46 R 1.90 B_V 0.63
# AO Reference star: 0
23:54:10.044 +23:11:55.37 RADEC 2000.0 J2000 89.8 -260.3 15.20 R 1.91 B_V 1.65
preset, AO1063, MODE=ACE, GS=1, RS=0
Thu Sep 20 07:00:01.120 2012 aos.PresetAO.started -
PresetAO[121] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.36646e-05,ro2:-4.28196e-05,mag:15.2,cindex:1.91,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 07:00:01.171 2012 aos.info - WFS source set to: FLAOWFS
Acquire measurements for bin 2@1kHz.
7:11. SEEING:1.1"
IDL> iif_preset,ao42,mode=ace,gs=1,rs=0,pa=90
# Target star: 0 AO42
00:40:56.23 +31:22:56.5 RADEC 2000.0 J2000 -39.0 -335.0 12.80 R 2.00 B_V 1.65
# Guide star: 1
00:41:10.861 +31:23:22.99 RADEC 2000.0 J2000 0.0 0.0 15.21 R 0.94 B_V 0.63
# AO Reference star: 0
00:40:56.23 +31:22:56.5 RADEC 2000.0 J2000 -39.0 -335.0 12.80 R 2.00 B_V 1.65
preset, AO42, MODE=ACE, GS=1, RS=0, PA=90
Thu Sep 20 07:21:41.205 2012 aos.PresetAO.started -
PresetAO[143] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:3.10736e-09,ro2:1.80681e-07,mag:12.8,cindex:2,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 07:21:41.256 2012 aos.info - WFS source set to: FLAOWFS
IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] =
RunAO result status: Error err = Resmsg[1] = err = Resmsg[2] =
AcquireRef[144] failed
Thu Sep 20 07:26:34.213 2012 aos.AcquireRef.failed -
AcquireRef[144] failed
RIP during the acquire reference.
RESEND THE SAME PRESET.
Thu Sep 20 07:29:51.943 2012 aos.PresetAO.started -
PresetAO[147] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-3.7617e-07,ro2:1.83628e-06,mag:12.8,cindex:2,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 07:29:51.994 2012 aos.info - WFS source set to: FLAOWFS
With this star we can see that the offload is not offloading all the tilt. EL85 degrees. the loop is close at BIN 2 600Hz. To see the effect looks the Command Tab in the figure; offload el85 bin 2@ 600Hz
<offload_el85.
7:46 SEEING:1"
CHECK WITH A LOW STAR.The next one at 78 degrees
IDL> iif_preset,ao801,mode=ace,gs=8,rs=0,pa=0
# Target star: 0 AO801
23:51:22.28 +23:44:20.8 RADEC 2000.0 J2000 265.0 -74.0 12.70 R 2.63 B_V 1.65
# Guide star: 8
23:51:10.344 +23:45:18.52 RADEC 2000.0 J2000 0.0 0.0 12.80 R 1.31 B_V 0.63
# AO Reference star: 0
23:51:22.28 +23:44:20.8 RADEC 2000.0 J2000 265.0 -74.0 12.70 R 2.63 B_V 1.65
preset, AO801, MODE=ACE, GS=8, RS=0
Thu Sep 20 07:50:20.264 2012 aos.PresetAO.started -
PresetAO[163] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.44551e-06,ro2:8.18101e-07,mag:12.7,cindex:2.63,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 07:50:20.315 2012 aos.info - WFS source set to: FLAOWFS
Check Pointing
With this new Star, the effect of the tilt in the offload is not visible, the AO system is working a more "relaxed". To see the effect looks the Command Tab in the figure; offload el77 bin 2@600Hz.
8:08. SEEING:0.9"
AFTER AN OFFSET FROM THE WFS, THE OFFSET ARE NOT COMPLETE AFTER 5 MINUTES. InformationTechnology SEEMS THAT THE GCS WAS STUCK. RESTART THE GCS subsystem
IDL> iif_preset,ao801,mode=ace,gs=8,rs=0,pa=0
# Target star: 0 AO801
23:51:22.28 +23:44:20.8 RADEC 2000.0 J2000 265.0 -74.0 12.70 R 2.63 B_V 1.65
# Guide star: 8
23:51:10.344 +23:45:18.52 RADEC 2000.0 J2000 0.0 0.0 12.80 R 1.31 B_V 0.63
# AO Reference star: 0
23:51:22.28 +23:44:20.8 RADEC 2000.0 J2000 265.0 -74.0 12.70 R 2.63 B_V 1.65
preset, AO801, MODE=ACE, GS=8, RS=0
Thu Sep 20 08:16:41.265 2012 aos.PresetAO.started -
PresetAO[168] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:6.0328e-05,ro2:8.69269e-05,mag:12.7,cindex:2.63,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 08:16:41.316 2012 aos.info - WFS source set to: FLAOWFS
Acquire measurements for BIN2@600Hz.
IDL> iif_preset,ao109,mode=ace,gs=3,rs=0,pa=0
# Target star: 0 AO109
03:07:00.89 +32:17:36.6 RADEC 2000.0 J2000 409.0 -233.0 13.70 R 2.20 B_V 1.65
# Guide star: 3
03:07:01.996 +32:19:20.36 RADEC 2000.0 J2000 -8.0 -2.0 13.56 R 1.13 B_V 0.63
# AO Reference star: 0
03:07:00.89 +32:17:36.6 RADEC 2000.0 J2000 409.0 -233.0 13.70 R 2.20 B_V 1.65
preset, AO109, MODE=ACE, GS=3, RS=0
Thu Sep 20 08:37:16.650 2012 aos.PresetAO.started -
PresetAO[184] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:8.10546e-07,ro2:6.49317e-08,mag:13.7,cindex:2.2,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 08:37:16.701 2012 aos.info - WFS source set to: FLAOWFS
8:44. SEEING:1.09"
Thu Sep 20 08:46:33.380 2012 aos.StartAO.failed -
StartAO[186] failed - thWaitMsg error(-5001): Timeout error
===> Error in irc_runao
err = Resmsg[0] =
RunAO result status: Error
err = Resmsg[1] =
AcquireRef[185] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:13.16 nBins:2 nModes:110 r0:0 snMode:0 strehl:0 ttMod:3
err = Resmsg[2] = thWaitMsg error(-5001): Timeout error
err = Resmsg[3] =
StartAO[186] failed - thWaitMsg error(-5001): Timeout error
Change star to get the bin 3t match the bin 3 magnitude.
IDL> iif_preset,ao130,mode=ace,gs=5,rs=0,pa=0
# Target star: 0 AO130
03:08:23.71 +43:02:08.6 RADEC 2000.0 J2000 371.0 -378.0 14.10 R 1.70 B_V 1.65
# Guide star: 5
03:08:35.250 +43:02:24.63 RADEC 2000.0 J2000 0.0 0.0 13.86 R 0.89 B_V 0.63
# AO Reference star: 0
03:08:23.71 +43:02:08.6 RADEC 2000.0 J2000 371.0 -378.0 14.10 R 1.70 B_V 1.65
preset, AO130, MODE=ACE, GS=5, RS=0
Thu Sep 20 08:49:59.958 2012 aos.PresetAO.started -
PresetAO[188] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.1226e-07,ro2:-1.02997e-07,mag:14.1,cindex:1.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 08:50:00.009 2012 aos.info - WFS source set to: FLAOWFS
Acquire measurements for BIN3@200Hz.
9:00. SEEING:0.8"
IDL> iif_preset,ao130,mode=ace,gs=5,rs=0,pa=0
# Target star: 0 AO130
03:08:23.71 +43:02:08.6 RADEC 2000.0 J2000 371.0 -378.0 14.10 R 1.70 B_V 1.65
# Guide star: 5
03:08:35.250 +43:02:24.63 RADEC 2000.0 J2000 0.0 0.0 13.86 R 0.89 B_V 0.63
# AO Reference star: 0
03:08:23.71 +43:02:08.6 RADEC 2000.0 J2000 371.0 -378.0 14.10 R 1.70 B_V 1.65
preset, AO130, MODE=ACE, GS=5, RS=0
Thu Sep 20 09:07:37.239 2012 aos.PresetAO.started -
PresetAO[204] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.6178e-08,ro2:8.36708e-08,mag:14.1,cindex:1.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 09:07:37.289 2012 aos.info - WFS source set to: FLAOWFS
<RIP. during the close loop. Loosing elevation telemetry.>
adsecarb.L |ERR| 1277|2012-09-20 09:18:19.442585| MAIN > Elevation not available! Resting the shell.
9:21. SEEING:0.9"
IDL> iif_preset,ao130,mode=ace,gs=5,rs=0,pa=0
# Target star: 0 AO130
03:08:23.71 +43:02:08.6 RADEC 2000.0 J2000 371.0 -378.0 14.10 R 1.70 B_V 1.65
# Guide star: 5
03:08:35.250 +43:02:24.63 RADEC 2000.0 J2000 0.0 0.0 13.86 R 0.89 B_V 0.63
# AO Reference star: 0
03:08:23.71 +43:02:08.6 RADEC 2000.0 J2000 371.0 -378.0 14.10 R 1.70 B_V 1.65
preset, AO130, MODE=ACE, GS=5, RS=0
Thu Sep 20 09:22:45.789 2012 aos.PresetAO.started -
PresetAO[212] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:3.83776e-07,ro2:-3.86668e-07,mag:14.1,cindex:1.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 09:22:45.840 2012 aos.info - WFS source set to: FLAOWFS
9:34. SEEING:0.9"
IDL> iif_preset,ao202,mode=ace,gs=1,rs=0,pa=0
# Target star: 0 AO202
04:01:32.37 +41:06:38.6 RADEC 2000.0 J2000 150.0 -343.0 15.10 R 2.30 B_V 1.65
# Guide star: 1
04:01:19.076 +41:07:42.21 RADEC 2000.0 J2000 0.0 0.0 11.04 R 0.93 B_V 0.63
# AO Reference star: 0
04:01:32.37 +41:06:38.6 RADEC 2000.0 J2000 150.0 -343.0 15.10 R 2.30 B_V 1.65
preset, AO202, MODE=ACE, GS=1, RS=0
GCS STUCK. RESTART THE SYSTEM AND THE PRESET IS CANCEL
MANUAL CLOSE THE LOOP WITH THE PREVIOUS STAR A0130
Acquire measurements for BIN3@200Hz.
IDL> iif_preset,ao202,mode=ace,gs=1,rs=0,pa=0
# Target star: 0 AO202
04:01:32.37 +41:06:38.6 RADEC 2000.0 J2000 150.0 -343.0 15.10 R 2.30 B_V 1.65
# Guide star: 1
04:01:19.076 +41:07:42.21 RADEC 2000.0 J2000 0.0 0.0 11.04 R 0.93 B_V 0.63
# AO Reference star: 0
04:01:32.37 +41:06:38.6 RADEC 2000.0 J2000 150.0 -343.0 15.10 R 2.30 B_V 1.65
preset, AO202, MODE=ACE, GS=1, RS=0
Thu Sep 20 10:02:01.722 2012 aos.PresetAO.started -
PresetAO[232] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.73999e-07,ro2:4.74368e-08,mag:15.1,cindex:2.3,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 10:02:01.772 2012 aos.info - WFS source set to: FLAOWFS
SKIP during the acquire reference star.
Thu Sep 20 10:08:03.907 2012 aos.StartAO.failed -
StartAO[234] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
===> Error in irc_runao
err = Resmsg[0] =
RunAO result status: Error
err = Resmsg[1] =
AcquireRef[233] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:13.996 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
err = Resmsg[3] =
StartAO[234] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
Debugging.
IDL> iif_preset,ao202,mode=ace,gs=1,rs=0,pa=0
# Target star: 0 AO202
04:01:32.37 +41:06:38.6 RADEC 2000.0 J2000 150.0 -343.0 15.10 R 2.30 B_V 1.65
# Guide star: 1
04:01:19.076 +41:07:42.21 RADEC 2000.0 J2000 0.0 0.0 11.04 R 0.93 B_V 0.63
# AO Reference star: 0
04:01:32.37 +41:06:38.6 RADEC 2000.0 J2000 150.0 -343.0 15.10 R 2.30 B_V 1.65
preset, AO202, MODE=ACE, GS=1, RS=0
Thu Sep 20 10:22:37.901 2012 aos.PresetAO.started -
PresetAO[240] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.62007e-06,ro2:-3.04454e-07,mag:15.1,cindex:2.3,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 10:22:37.951 2012 aos.info - WFS source set to: FLAOWFS
SKIP during the acquire reference. The system loaded the same reconstructor for BIN3. The effect of the SKIP can be seeing in the figure; *skip frame at BIN 3.*
===> Error in irc_runao
err = Resmsg[0] =
RunAO result status: Error
err = Resmsg[1] =
AcquireRef[241] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:13.971 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6
err = Resmsg[2] = Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
err = Resmsg[3] =
StartAO[242] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
MANUAL CLOSE LOOP.
SKIP. Same kind of skip than before
MANUAL CLOSE LOOP.
10:35. SEEING:1.12"
SKIP. WITH THIS STAR THE AO SYSTEM CAN'T CLOSE THE LOOP.
BACK TO STAR AO130
IDL> iif_preset,ao130,mode=ace,gs=5,rs=0,pa=0
# Target star: 0 AO130
03:08:23.71 +43:02:08.6 RADEC 2000.0 J2000 371.0 -378.0 14.10 R 1.70 B_V 1.65
# Guide star: 5
03:08:35.250 +43:02:24.63 RADEC 2000.0 J2000 0.0 0.0 13.86 R 0.89 B_V 0.63
# AO Reference star: 0
03:08:23.71 +43:02:08.6 RADEC 2000.0 J2000 371.0 -378.0 14.10 R 1.70 B_V 1.65
preset, AO130, MODE=ACE, GS=5, RS=0
Thu Sep 20 11:07:56.038 2012 aos.PresetAO.started -
PresetAO[248] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.18515e-06,ro2:-6.29837e-07,mag:14.1,cindex:1.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 11:07:56.089 2012 aos.info - WFS source set to: FLAOWFS
BAYSIDE STAGE Y DIDN'T MOVE.
Thu Sep 20 11:11:32.918 2012 aos.AcquireRef.failed -
AcquireRef[249] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR
IDL> iif_runao
===> Error in irc_runao
err = Resmsg[0] =
RunAO result status: Error err = Resmsg[1] = Timeout error on baysidey (-5001) TIMEOUT_ERROR
err = Resmsg[2] =
AcquireRef[249] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR
Resent the preset.
Thu Sep 20 11:12:24.039 2012 aos.PresetAO.started -
PresetAO[251] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:1.73697e-08,ro2:-1.73735e-08,mag:14.1,cindex:1.7,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 11:12:24.089 2012 aos.info - WFS source set to: FLAOWFS
IDL> iif_preset,ao202,mode=ace,gs=1,rs=0,pa=0
# Target star: 0 AO202
04:01:32.37 +41:06:38.6 RADEC 2000.0 J2000 150.0 -343.0 15.10 R 2.30 B_V 1.65
# Guide star: 1
04:01:19.076 +41:07:42.21 RADEC 2000.0 J2000 0.0 0.0 11.04 R 0.93 B_V 0.63
# AO Reference star: 0
04:01:32.37 +41:06:38.6 RADEC 2000.0 J2000 150.0 -343.0 15.10 R 2.30 B_V 1.65
preset, AO202, MODE=ACE, GS=1, RS=
Thu Sep 20 12:06:07.548 2012 aos.PresetAO.started -
PresetAO[310] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-1.45158e-06,ro2:-3.21208e-07,mag:15.1,cindex:2.3,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 12:06:07.599 2012 aos.info - WFS source set to: FLAOWFS
SKIP during the acquire.
Debugging the bug that we saw with the star ao202
===> Error in irc_runao
err = Resmsg[0] =
RunAO result status: Error
err = Resmsg[1] =
AcquireRef[315] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:14.169 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6
err = Resmsg[2] = wfsarb:Illegal command for state AOSet (
OptimizeGain)
err = Resmsg[3] =
StartAO[316] failed - wfsarb:Illegal command for state AOSet (
OptimizeGain)
12:15. SEEING:1.45"
ROTATOR OVER HEAT. Due to tree-house fans off.
Check pointing
IDL> iif_preset,ao202,mode=ace,gs=1,rs=0,pa=0
# Target star: 0 AO202
04:01:32.37 +41:06:38.6 RADEC 2000.0 J2000 150.0 -343.0 15.10 R 2.30 B_V 1.65
# Guide star: 1
04:01:19.076 +41:07:42.21 RADEC 2000.0 J2000 0.0 0.0 11.04 R 0.93 B_V 0.63
# AO Reference star: 0
04:01:32.37 +41:06:38.6 RADEC 2000.0 J2000 150.0 -343.0 15.10 R 2.30 B_V 1.65
preset, AO202, MODE=ACE, GS=1, RS=0
BAYSIDE STAGE Y DIDN'T MOVE.
===> Error in irc_runao
err = Resmsg[0] =
RunAO result status: Error err = Resmsg[1] = Timeout error on baysidey (-5001) TIMEOUT_ERROR
err = Resmsg[2] =
AcquireRef[326] failed - Timeout error on baysidey (-5001) TIMEOUT_ERROR
IDL> iif_runao
IDL> iif_preset,ao202,mode=ace,gs=1,rs=0,pa=0
# Target star: 0 AO202
04:01:32.37 +41:06:38.6 RADEC 2000.0 J2000 150.0 -343.0 15.10 R 2.30 B_V 1.65
# Guide star: 1
04:01:19.076 +41:07:42.21 RADEC 2000.0 J2000 0.0 0.0 11.04 R 0.93 B_V 0.63
# AO Reference star: 0
04:01:32.37 +41:06:38.6 RADEC 2000.0 J2000 150.0 -343.0 15.10 R 2.30 B_V 1.65
preset, AO202, MODE=ACE, GS=1, RS=0
Thu Sep 20 12:23:31.499 2012 aos.PresetAO.started -
PresetAO[329] (aomode:ACE-AO,focalst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,so1:0,so2:0,ro1:-9.13675e-07,ro2:-3.45211e-07,mag:15.1,cindex:2.3,elev:nan,rotang:nan,gravang:nan,r0:0,skybrgt:nan,windspeed:nan,winddir:nan)
Thu Sep 20 12:23:31.550 2012 aos.info - WFS source set to: FLAOWFS
Debug the fault. and found the solution. Solution in place.
Stop 12:33
--
JuanGuerra - 19 Sep 2012
- Bin2 loosing part of the mirror:
- offload el85 bin 2@ 600Hz:
- offload el77 bin 2@600Hz:
- skip frame at BIN 3: