You are here: Foswiki>Commissioning Web>Logs>18Jun2012_Log (18 Jun 2012, JuanGuerra)Edit Attach

AO/PISCES . INAF SCIENCE NIGHTS

Observer: DMiller (Tucson), JGuerra, KBoutsia (LBTO)
Telescope Operator: SAllanson (LBTO)
Additional AO Support: RBriguglio, CArcidiacono (LBTO) APuglisi
Telescope Support: JUrban(LBTO)
Instrument Support: DOfficer (LBTO)

Summary

Telescope configure to LBC.

Power on the systems. The wfs reported a failure of the bayside stage during the power on procedure Seeing variable 1.2"-1.9" The loop broke a few times and the observe scripts was canceled, the preset has been resend.

Details

Mon Jun 18 04:51:49.046 2012 aos.WfsOn.failed - WfsOn[539] failed - baysidex in wrong state for requested operation. Current state: STATE_NOCONNECTION. (-11005) CTRL_WRONG_STATE_ERROR.

A second power on procedure is sent and is completed. -Switch to Pisces+AO 6:16 UT.

The variable seeing during this night made the loop instable, but, only one time the loop broke, we are observing in bin 3@66 modes.

There were two failures due to propbably that the wfsarbitrator lost the communicaiton with the message deamon. This fault needs a hard recover, restarting the wfs software.

Another failure was the bcu39 which happened two time. This happened during the loop close and a new preset has to be sent.

STOP 11:56...

-- JuanGuerra - 18 Jun 2012
Topic revision: r3 - 18 Jun 2012, JuanGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.