You are here: Foswiki>Commissioning Web>Logs>11Sep2012_Log (12 Sep 2012, JuanGuerra)Edit Attach

UT 20120910 AO#2 Commissioning

Observer: R. Bruglia, A. Puglisi, E. Pinna (LBTO)
Telescope Operator: G.(LBTO)
Additional AO Support: JCGuerra (LBTO)
Telescope Support: (LBTO)
Instrument Support: J.Morris (LBTO)

Summary

Startup of wfssx.ok, ASM_SX set ok. Startup of wfsdx failed. A second try gave the power on. ASM_DX set ok, the shell is left set.

The daytime work for the W# requires a telescope set up, this set is: Tree-house fan OFF, doors open and vent door open. The HBS ON, the stow pin IN and the Elevation breaks REL.

New reconstructor for bin 4, bin 3 and a bin 1. Ckecking the performances of bin 4, bin 3 and bin 1. The performances are checked looking the strehl ration adn the modal variance of the recosntructured wavefront.

The secondary rip once due to lost elecvation telemetry. This faults was resolved sopt/start of teh AOS subsystem. Another RIP came when the AOS stop to offload the offloading commands. The failure state was solved restarting teh AOS subsystem.

Problem with the LBT rotator, the system didn't restart properly, it seems that it was too hot in the tree-house computer room, the doors and the small vent window left open during the daytime work with the W#

Problem with the slope computer after taking darks with the high-order camera (ccd39).

Enrico Pinna will send a detailed report.

Hand-over: 16:00 (local time). Retro-reflector left on.

Details

4D.

Nothing to report. Interferometer working properly. It is still used to acquire interferograms images.

Secondary

The secondary is working at open and close loop and the behaves is good, we haven't seen any jump actuator or other artefacts due to bad positions or current to the actuators. Interfograms are taking with to see if the "jump actuator" removed from the current control show the same effect that yesterday. The data analysed showed that the effect don't showed. The secondary.

Left W# unit

The system is working properly and it shows a stability of the software. We had a problem taken darks with the high-order ccd (CCD39), the W# system reposrts an error with the slope computer when is loading the dark, we saw that the AOS is updating the variable AOS.EXTERN.WINSPEED with some characters at the end that they are not recognize by the W# when load a dark file. The problem was solved removing this fake new variable from the W# variable list.

A new reconstructor for bin 4 was built and for the bin 1. The results of the measurements are showed in the table below;

BIN 4. New Rec: 191948 Old Rec: 200610

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120911_203840 ??? 7.8 90 4 NaN -1.00 200610 4 36 994 0.4 0.6 0.5 6 8749 ON 3.5 J 700 20 ON NO  
20120911_203859 ??? 7.8 90 3 NaN -1.00 200610 4 36 994 0.4 0.6 0.5 6 8749 ON 3.8 J 700 20 ON NO  
20120911_203917 ??? 7.8 90 2 NaN -1.00 200610 4 36 994 0.4 0.6 0.5 6 8751 ON 3.1 J 700 20 ON NO  
20120911_204006 ??? 7.8 90 8 NaN -1.00 200610 4 36 994 0.4 0.6 0.5 6 8633 ON 3.9 J 700 20 ON NO  
20120911_204024 ??? 7.8 90 2 NaN -1.00 200610 4 36 994 0.4 0.6 0.5 6 8716 ON 3.6 J 700 20 ON NO  
20120911_204042 ??? 7.8 90 5 NaN -1.00 200610 4 36 994 0.4 0.6 0.5 6 8744 ON 3.8 J 700 20 ON NO  
20120911_204109 ??? 7.8 90 4 NaN -1.00 200610 4 36 994 0.4 0.6 0.5 6 8765 ON 3.8 J 700 20 ON NO - Background correction failed
20120911_204127 ??? 7.8 90 5 NaN -1.00 200610 4 36 994 0.4 0.6 0.5 6 8771 ON 3.7 J 700 20 ON NO  
20120911_204145 ??? 7.8 90 6 NaN -1.00 200610 4 36 994 0.4 0.6 0.5 6 8770 ON 3.8 J 700 20 ON NO  
20120911_204234 ??? 7.8 90 6 NaN -1.00 200610 4 36 994 0.4 0.6 0.5 6 8639 ON 3.7 J 700 20 ON NO  
20120911_204252 ??? 7.8 90 6 NaN -1.00 200610 4 36 994 0.4 0.6 0.5 6 8723 ON 3.3 J 700 20 ON NO - Background correction failed
20120911_204310 ??? 7.8 90 4 NaN -1.00 200610 4 36 994 0.4 0.6 0.5 6 8754 ON 3.8 J 700 20 ON NO  
20120911_205728 ??? 7.7 90 12 NaN -1.00 191948 4 36 994 0.5 0.6 0.4 6 8888 ON 3.1 J 700 20 ON NO - Background correction failed
20120911_205746 ??? 7.7 90 7 NaN -1.00 191948 4 36 994 0.5 0.6 0.4 6 8887 ON 3.2 J 700 20 ON NO  
20120911_205804 ??? 7.7 90 5 NaN -1.00 191948 4 36 994 0.5 0.6 0.4 6 8888 ON 3.1 J 700 20 ON NO  
20120911_205852 ??? 7.8 90 7 NaN -1.00 191948 4 36 994 0.5 0.6 0.4 6 8738 ON 2.7 J 700 20 ON NO  
20120911_205911 ??? 7.8 90 1 NaN -1.00 191948 4 36 994 0.5 0.6 0.4 6 8823 ON 2.8 J 700 20 ON NO  
20120911_205929 ??? 7.7 90 4 NaN -1.00 191948 4 36 994 0.5 0.6 0.4 6 8854 ON 2.9 J 700 20 ON NO  
20120911_210020 ??? 7.7 90 2 NaN -1.00 191948 4 36 994 0.5 0.6 0.4 6 8881 ON 2.7 J 700 20 ON NO  
20120911_210038 ??? 7.7 90 5 NaN -1.00 191948 4 36 994 0.5 0.6 0.4 6 8883 ON 2.9 J 700 20 ON NO - Background correction failed
20120911_210056 ??? 7.7 90 7 NaN -1.00 191948 4 36 994 0.5 0.6 0.4 6 8882 ON 2.9 J 700 20 ON NO - Background correction failed
20120911_210145 ??? 7.8 90 4 NaN -1.00 191948 4 36 994 0.5 0.6 0.4 6 8725 ON 2.3 J 700 20 ON NO  
20120911_210204 ??? 7.8 90 2 NaN -1.00 191948 4 36 994 0.5 0.6 0.4 6 8813 ON 2.4 J 700 20 ON NO  
20120911_210222 ??? 7.7 90 8 NaN -1.00 191948 4 36 994 0.5 0.6 0.4 6 8844 ON 2.4 J 700 20 ON NO  
20120911_210720 ??? 7.8 90 3 NaN -1.00 200610 4 36 994 0.6 0.5 -1.0 6 8779 ON 3.9 J 700 20 ON NO  
20120911_210808 ??? 7.8 90 4 NaN -1.00 200610 4 36 994 0.6 0.5 -1.0 6 8651 ON 4.1 J 700 20 ON NO - Pupils not on target
20120911_210826 ??? 7.8 90 3 NaN -1.00 200610 4 36 994 0.6 0.5 -1.0 6 8736 ON 4.0 J 700 20 ON NO  
20120911_210845 ??? 7.8 90 10 NaN -1.00 200610 4 36 994 0.6 0.5 -1.0 6 8767 ON 4.0 J 700 20 ON NO  
20120911_210922 ??? 7.8 90 3 NaN -1.00 200610 4 36 994 0.6 0.5 -1.0 6 8787 ON 4.1 J 700 20 ON NO  
20120911_210941 ??? 7.8 90 8 NaN -1.00 200610 4 36 994 0.6 0.5 -1.0 6 8786 ON 4.0 J 700 20 ON NO  
20120911_210959 ??? 7.8 90 4 NaN -1.00 200610 4 36 994 0.6 0.5 -1.0 6 8792 ON 4.2 J 700 20 ON NO - Background correction failed
20120911_211047 ??? 7.8 90 10 NaN -1.00 200610 4 36 994 0.6 0.5 -1.0 6 8643 ON 3.4 J 700 20 ON NO  
20120911_211105 ??? 7.8 90 3 NaN -1.00 200610 4 36 994 0.6 0.5 -1.0 6 8731 ON 3.2 J 700 20 ON NO  
20120911_211124 ??? 7.8 90 2 NaN -1.00 200610 4 36 994 0.6 0.5 -1.0 6 8761 ON 3.2 J 700 20 ON NO - Background correction failed

BIN1: New Rec.20120911_224013

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120911_230332 ??? 7.6 90 14 NaN -1.00 224013 1 500 990 0.6 0.5 0.3 3 527 ON 38.9 J 100 100 ON NO  
20120911_230350 ??? 7.6 90 17 NaN -1.00 224013 1 500 990 0.6 0.5 0.3 3 527 ON 37.1 J 100 100 ON NO  
20120911_230409 ??? 7.6 90 13 NaN -1.00 224013 1 500 990 0.6 0.5 0.3 3 527 ON 38.1 J 100 100 ON NO  
20120911_230459 ??? 7.7 90 15 NaN -1.00 224013 1 500 990 0.6 0.5 0.3 3 516 ON 37.3 J 100 100 ON NO  
20120911_230517 ??? 7.7 90 15 NaN -1.00 224013 1 500 990 0.6 0.5 0.3 3 521 ON 39.6 J 100 100 ON NO  
20120911_230536 ??? 7.6 90 15 NaN -1.00 224013 1 500 990 0.6 0.5 0.3 3 524 ON 37.4 J 100 100 ON NO  
20120911_230703 ??? 7.6 90 -2147483648 NaN -1.00 224013 1 500 990 0.6 0.5 0.3 3 527 ON 37.0 J 100 100 ON NO  
20120911_230722 ??? 7.6 90 -2147483648 NaN -1.00 224013 1 500 990 0.6 0.5 0.3 3 527 ON 39.0 J 100 100 ON NO  
20120911_230741 ??? 7.6 90 -2147483648 NaN -1.00 224013 1 500 990 0.6 0.5 0.3 3 528 ON 39.8 J 100 100 ON NO  
20120911_230831 ??? 7.7 90 -2147483648 NaN -1.00 224013 1 500 990 0.6 0.5 0.3 3 517 ON 35.9 J 100 100 ON NO  
20120911_230850 ??? 7.7 90 -2147483648 NaN -1.00 224013 1 500 990 0.6 0.5 0.3 3 522 ON 39.4 J 100 100 ON NO  
20120911_230910 ??? 7.6 90 -2147483648 NaN -1.00 224013 1 500 990 0.6 0.5 0.3 3 524 ON 40.5 J 100 100 ON NO  

BIN 1: Rec: 20120909_222555, Rec: 20120911_224013

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120911_231307 ??? 7.6 90 -2147483648 NaN -1.00 222555 1 500 990 0.6 0.4 0.3 3 528 ON 35.5 J 100 100 ON NO - long stop of 158 frames at frame 175
20120911_231326 ??? 7.6 90 -2147483648 NaN -1.00 222555 1 500 990 0.6 0.4 0.3 3 528 ON 35.6 J 100 100 ON NO - long stop of 115 frames at frame 215
20120911_231345 ??? 7.6 90 -2147483648 NaN -1.00 222555 1 500 990 0.6 0.4 0.3 3 528 ON 37.1 J 100 100 ON NO - long stop of 155 frames at frame 2912
20120911_231436 ??? 7.7 90 -2147483648 NaN -1.00 222555 1 500 990 0.6 0.4 0.3 3 519 ON 34.1 J 100 100 ON NO  
20120911_231454 ??? 7.6 90 -2147483648 NaN -1.00 222555 1 500 990 0.6 0.4 0.3 3 524 ON 33.2 J 100 100 ON NO  
20120911_231513 ??? 7.6 90 -2147483648 NaN -1.00 222555 1 500 990 0.6 0.4 0.3 3 526 ON 35.4 J 100 100 ON NO  
20120911_231549 ??? 7.6 90 -2147483648 NaN -1.00 222555 1 500 990 0.6 0.4 0.3 3 528 ON 34.1 J 100 100 ON NO  
20120911_231608 ??? 7.6 90 -2147483648 NaN -1.00 222555 1 500 990 0.6 0.4 0.3 3 527 ON 31.1 J 100 100 ON NO  
20120911_231626 ??? 7.6 90 -2147483648 NaN -1.00 222555 1 500 990 0.6 0.4 0.3 3 528 ON 32.3 J 100 100 ON NO  
20120911_231716 ??? 7.7 90 -2147483648 NaN -1.00 222555 1 500 990 0.6 0.4 0.3 3 522 ON 31.7 J 100 100 ON NO  
20120911_231734 ??? 7.6 90 -2147483648 NaN -1.00 222555 1 500 990 0.6 0.4 0.3 3 528 ON 31.7 J 100 100 ON NO - long stop of 66 frames at frame 753
20120911_231753 ??? 7.6 90 -2147483648 NaN -1.00 222555 1 500 990 0.6 0.4 0.3 3 531 ON 32.1 J 100 100 ON NO  
20120911_234312 ??? 7.7 90 6 NaN -1.00 224013 1 500 990 0.4 0.4 0.4 3 519 ON 37.6 J 50 200 ON NO  
20120911_234337 ??? 7.7 90 7 NaN -1.00 224013 1 500 990 0.4 0.4 0.4 3 520 ON 37.7 J 50 200 ON NO  
20120911_234401 ??? 7.7 90 11 NaN -1.00 224013 1 500 990 0.4 0.4 0.4 3 516 ON 39.8 J 50 200 ON NO  
20120911_234503 ??? 7.7 90 9 NaN -1.00 224013 1 500 990 0.4 0.4 0.4 3 509 ON 36.9 J 50 200 ON NO  
20120911_234528 ??? 7.7 90 8 NaN -1.00 224013 1 500 990 0.4 0.4 0.4 3 516 ON 38.8 J 50 200 ON NO  
20120911_234554 ??? 7.7 90 14 NaN -1.00 224013 1 500 990 0.4 0.4 0.4 3 517 ON 37.6 J 50 200 ON NO  
20120911_234909 ??? 7.7 90 14 NaN -1.00 224013 1 500 990 0.4 0.4 0.4 3 523 ON 37.3 J 50 200 ON NO  
20120911_234934 ??? 7.7 90 13 NaN -1.00 224013 1 500 990 0.4 0.4 0.4 3 518 ON 37.8 J 50 200 ON NO  
20120911_234959 ??? 7.7 90 12 NaN -1.00 224013 1 500 990 0.4 0.4 0.4 3 517 ON 38.2 J 50 200 ON NO - long stop of 110 frames at frame 0
20120911_235102 ??? 7.7 90 13 NaN -1.00 224013 1 500 990 0.4 0.4 0.4 3 511 ON 36.4 J 50 200 ON NO  
20120911_235126 ??? 7.7 90 12 NaN -1.00 224013 1 500 990 0.4 0.4 0.4 3 518 ON 37.3 J 50 200 ON NO  
20120911_235151 ??? 7.7 90 14 NaN -1.00 224013 1 500 990 0.4 0.4 0.4 3 520 ON 37.0 J 50 200 ON NO  
20120912_000150 ??? 7.7 90 13 NaN -1.00 224013 1 500 990 0.6 0.5 0.4 3 519 ON 41.5 J 50 200 ON NO  
20120912_000214 ??? 7.7 90 13 NaN -1.00 224013 1 500 990 0.6 0.5 0.4 3 519 ON 38.0 J 50 200 ON NO - long stop of 143 frames at frame 3691
20120912_000239 ??? 7.7 90 10 NaN -1.00 224013 1 500 990 0.6 0.5 0.4 3 519 ON 38.5 J 50 200 ON NO - long stop of 99 frames at frame 3
20120912_000342 ??? 7.7 90 11 NaN -1.00 224013 1 500 990 0.6 0.5 0.4 3 509 ON 39.3 J 50 200 ON NO  
20120912_000407 ??? 7.7 90 14 NaN -1.00 224013 1 500 990 0.6 0.5 0.4 3 517 ON 39.5 J 50 200 ON NO  
20120912_000431 ??? 7.7 90 12 NaN -1.00 224013 1 500 990 0.6 0.5 0.4 3 519 ON 39.3 J 50 200 ON NO  

BIN 1. Rec:20120909_222555

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120912_000934 ??? 7.7 90 7 NaN -1.00 222555 1 500 990 0.6 0.3 0.3 3 519 ON 38.3 J 50 200 ON NO  
20120912_000959 ??? 7.7 90 9 NaN -1.00 222555 1 500 990 0.6 0.3 0.3 3 520 ON 36.8 J 50 200 ON NO  
20120912_001023 ??? 7.7 90 11 NaN -1.00 222555 1 500 990 0.6 0.3 0.3 3 520 ON 37.2 J 50 200 ON NO  
20120912_001125 ??? 7.7 90 12 NaN -1.00 222555 1 500 990 0.6 0.3 0.3 3 510 ON 36.7 J 50 200 ON NO  
20120912_001151 ??? 7.7 90 11 NaN -1.00 222555 1 500 990 0.6 0.3 0.3 3 516 ON 37.4 J 50 200 ON NO  
20120912_001217 ??? 7.7 90 11 NaN -1.00 222555 1 500 990 0.6 0.3 0.3 3 520 ON 33.8 J 50 200 ON NO  
20120912_001526 ??? 7.7 90 10 NaN -1.00 222555 1 500 990 0.6 0.3 0.3 3 522 ON 37.2 J 50 200 ON NO  
20120912_001551 ??? 7.7 90 5 NaN -1.00 222555 1 500 990 0.6 0.3 0.3 3 521 ON 35.0 J 50 200 ON NO  
20120912_001617 ??? 7.7 90 12 NaN -1.00 222555 1 500 990 0.6 0.3 0.3 3 521 ON 37.4 J 50 200 ON NO  
20120912_001719 ??? 7.7 90 6 NaN -1.00 222555 1 500 990 0.6 0.3 0.3 3 513 ON 34.8 J 50 200 ON NO  
20120912_001744 ??? 7.7 90 7 NaN -1.00 222555 1 500 990 0.6 0.3 0.3 3 519 ON 36.4 J 50 200 ON NO  
20120912_001809 ??? 7.7 90 7 NaN -1.00 222555 1 500 990 0.6 0.3 0.3 3 521 ON 35.3 J 50 200 ON NO  