HEXAPOD POSITIONS:

X=1 Y=1.45 Z=4.5 RX:80 RY:163 RZ:0

M3: left front gegrorian. tip:-632,tilt:-94,p=0,sel:26.01

lbto@obs5:23 % more aos.conf # The following table associates an instrument name to a corresponding "flat" name AOSFlats map<string,string> IRTC:IRTC LUCIFER:LUCIFER MODS:MODS LBTI:LBTI

# AOS_L arcetri:AOSLMsgDIp string 127.0.0.1 # Message daemon IP number downtown:AOSLMsgDIp string 127.0.0.1 # Message daemon IP number AOSLMsgDIp string 192.168.13.12 # Message daemon IP number (adsecsx) arcetri:AOSLtv_file string /tmp/AOSLtv # TV filename (no extension) AOSLtv_file string /lbt/tmpdata/aos/AOSLtv arcetri:AOSLfl_file string /tmp/AOSLflats # Flat list AOSLfl_file string /lbt/tmpdata/aos/AOSLflats arcetri:AOSLdbgLevel int 2 # AOS debug level (0: info, 2: debug, 3: trace) AOSLdbgLevel int 2 arcetri:AOSLsimulation bool false # Set to true for simulation mode AOSLsimulation bool false arcetri:AOSLlogdir string /tmp # AOS own log directory AOSLlogdir string /lbt/log/aos # Currently not used arcetri:AOSLtelEnable bool true AOSLtelEnable bool true AOSLrotatorIndex int 0 # Index of rotator (0:front, 1:center, 2:back)

# AOS_R arcetri:AOSRMsgDIp string 127.0.0.1 # Message daemon IP number downtown:AOSRMsgDIp string 127.0.0.1 # Message daemon IP number AOSRMsgDIp string 192.168.11.12 # Message daemon IP number (adsecdx) arcetri:AOSRtv_file string /tmp/AOSRtv # TV filename (no extension) AOSRtv_file string /lbt/tmpdata/aos/AOSRtv arcetri:AOSRfl_file string /tmp/AOSRflats # Flat list AOSRfl_file string /lbt/tmpdata/aos/AOSRflats arcetri:AOSRdbgLevel int 2 # AOS debug level (0: info, 2: debug, 3: trace) AOSRdbgLevel int 2 arcetri:AOSRsimulation bool false # Set to true for simulation mode AOSRsimulation bool false arcetri:AOSRlogdir string /tmp # AOS own log directory AOSRlogdir string /lbt/log/aos # Currently not used arcetri:AOSRtelEnable bool true AOSRtelEnable bool true AOSRrotatorIndex int 0 # Index of rotator (0:front, 1:center, 2:back)

INIT_DIR_AOS string ./aos/configuration/AOS/ CONF_DIR_AOS string ./aos/configuration/AOS/

optical loop diag: 20130210_170944 _171011 _171025