You are here: Foswiki>Commissioning Web>Logs>09Sep2012_Log (10 Sep 2012, JuanGuerra)Edit Attach

UT 20120909 AO#2 Commissioning

Observer: R. Bruglia, A. Puglisi, E. Pinna (LBTO)
Telescope Operator: D. Gonzalez(LBTO)
Additional AO Support: JCGuerra (LBTO)
Telescope Support: (LBTO)
Instrument Support: J.Morris (LBTO)

Summary

Acquisition and analysis of the modes using the 4D to compare with the modes recorded before the ASM electronic repair. Identified two bad actuators which are removed from the list.

Performance test of the old reconstructors.

Acquisition of a new interaction matrix and two new reconstructor were built: Bin 1 at 400 & 500 modes. The reconstructors were tested and they perform better that the used before the siggen repair.

Communication problem with the PIC controller at the W#. It was identified the problem in the flat ribbon connector.

Hand-over 18:00

Details

4D.

Nothing to report. Interferometer working properly.

Secondary

Analysis of the previous date data and acquisition a new set of the interferograms. Runa will report the result analysis.

Left W# unit

The pic controller communication problem stopped to work with the RR configuration and a check of the flower pot was necesary. the pic controller seems working but there is a problem with the flat ribbon connector, this connector has to be checked and probably a new connector has to be built.

Performance check of the AO system at close loop at bin 1. The loop is close with the same configuraiton previous close loop performed last June. During the analysis of the modal plot of the data it was notics that the elab program wasn't reconstruct the modes variance correctly and after debugging the code it was able to get a correct modal plot. A new Reconstructor is built and the data are correlated to the data acquired with the reconstructor used before the siggen repair.

The new Rec @ BIN1: 20120909_221453. Old Rec:20120601_181313 The data are acquired following a set like as; New Rec -> Old rec ->New Rec ->Old Rec. The analysis of the two set of data is showed below;

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20120909_233744 ??? 7.5 90 4 NaN -1.00 221453 1 400 990 0.5 0.4 0.5 3 609 ON 48.3 J 50 200 ON NO  
20120909_233809 ??? 7.5 90 3 NaN -1.00 221453 1 400 990 0.5 0.4 0.5 3 605 ON 50.1 J 50 200 ON NO  
20120909_233834 ??? 7.5 90 1 NaN -1.00 221453 1 400 990 0.5 0.4 0.5 3 606 ON 52.3 J 50 200 ON NO  
20120909_233937 ??? 7.5 90 4 NaN -1.00 221453 1 400 990 0.5 0.4 0.5 3 592 ON 47.4 J 50 200 ON NO  
20120909_234002 ??? 7.5 90 2 NaN -1.00 221453 1 400 990 0.5 0.4 0.5 3 602 ON 48.2 J 50 200 ON NO  
20120909_234026 ??? 7.5 90 4 NaN -1.00 221453 1 400 990 0.5 0.4 0.5 3 605 ON 46.7 J 50 200 ON NO  
20120909_234147 ??? 7.5 90 4 NaN -1.00 181313 1 400 990 0.4 0.5 0.4 3 607 ON 42.0 J 50 200 ON NO - Pupils mismatch
20120909_234212 ??? 7.5 90 7 NaN -1.00 181313 1 400 990 0.4 0.5 0.4 3 607 ON 41.6 J 50 200 ON NO - Pupils mismatch
20120909_234237 ??? 7.5 90 7 NaN -1.00 181313 1 400 990 0.4 0.5 0.4 3 608 ON 47.9 J 50 200 ON NO - Pupils mismatch
20120909_234337 ??? 7.5 90 3 NaN -1.00 181313 1 400 990 0.4 0.5 0.4 3 594 ON 42.6 J 50 200 ON NO - Pupils mismatch
20120909_234402 ??? 7.5 90 3 NaN -1.00 181313 1 400 990 0.4 0.5 0.4 3 603 ON 46.3 J 50 200 ON NO - Pupils mismatch
20120909_234427 ??? 7.5 90 6 NaN -1.00 181313 1 400 990 0.4 0.5 0.4 3 606 ON 45.7 J 50 200 ON NO - Pupils mismatch
20120909_234549 ??? 7.5 90 4 NaN -1.00 221453 1 400 990 0.6 0.4 -1.0 3 607 ON 51.8 J 50 200 ON NO  
20120909_234614 ??? 7.5 90 4 NaN -1.00 221453 1 400 990 0.6 0.4 -1.0 3 606 ON 48.9 J 50 200 ON NO  
20120909_234639 ??? 7.5 90 5 NaN -1.00 221453 1 400 990 0.6 0.4 -1.0 3 606 ON 49.6 J 50 200 ON NO  
20120909_234740 ??? 7.5 90 2 NaN -1.00 221453 1 400 990 0.6 0.4 -1.0 3 593 ON 47.6 J 50 200 ON NO  
20120909_234805 ??? 7.5 90 2 NaN -1.00 221453 1 400 990 0.6 0.4 -1.0 3 602 ON 49.7 J 50 200 ON NO  
20120909_234830 ??? 7.5 90 2 NaN -1.00 221453 1 400 990 0.6 0.4 -1.0 3 608 ON 55.2 J 50 200 ON NO  
20120909_234949 ??? 7.5 90 8 NaN -1.00 181313 1 400 990 0.5 0.5 0.4 3 610 ON 50.6 J 50 200 ON NO - Pupils mismatch
20120909_235014 ??? 7.5 90 5 NaN -1.00 181313 1 400 990 0.5 0.5 0.4 3 609 ON 46.9 J 50 200 ON NO - Pupils mismatch
20120909_235039 ??? 7.5 90 3 NaN -1.00 181313 1 400 990 0.5 0.5 0.4 3 610 ON 47.1 J 50 200 ON NO - Pupils mismatch
20120909_235141 ??? 7.5 90 4 NaN -1.00 181313 1 400 990 0.5 0.5 0.4 3 597 ON 45.3 J 50 200 ON NO - Pupils mismatch
20120909_235205 ??? 7.5 90 5 NaN -1.00 181313 1 400 990 0.5 0.5 0.4 3 605 ON 46.3 J 50 200 ON NO - Pupils mismatch
20120909_235230 ??? 7.5 90 2 NaN -1.00 181313 1 400 990 0.5 0.5 0.4 3 608 ON 45.9 J 50 200 ON NO - Pupils mismatch

-- JuanGuerra - 10 Sep 2012
Topic revision: r1 - 10 Sep 2012, JuanGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback