AO Closed Loop Requests for 20120621

Statistics

PresetTelescopes
  • Number: 5
  • Average Time: 72.5404 seconds
PresetAO
  • Number: 5
  • Failed: 0
  • Average Time: 62.0906 seconds
AcquireRef
  • Number: 4
  • Failed: 0
  • Average Time: 93.8285 seconds
StartAO
  • Number: 4
  • Failed: 0
  • Average Time: 35.0065 seconds
Offsets
  • Number: 51
  • Failed: 1
  • Average Time: 8.30126 seconds

  • Jun 21 08:08:41 tcs2 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 21 08:08:41 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 21 08:10:29 tcs2 LBT_AOSR: [I] PresetAO[2123] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:312 mag:0 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6
    • Jun 21 08:10:29 tcs2 LBT_AOSR: AOSR:PresetAO execution time: 107801 ms from IIF, handle 2154
  • Jun 21 08:10:29 tcs2 LBT_IIF: IIF:Preset execution time: 110354 ms from IIF, handle 891233
  • Jun 21 08:10:29 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
08:10:29 PresetAO SUCCESS

  • Jun 21 08:10:37 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 891552
    • Jun 21 08:10:37 tcs2 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 2155
    • Jun 21 08:10:37 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 21 08:10:37 tcs2 LBT_AOSR: [D] AcquireRef command received.
    • Jun 21 08:10:37 tcs2 LBT_AOSR: [I] AcquireRef[2124]
    • Jun 21 08:11:16 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AORunning
    • Jun 21 08:11:49 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AOSet
    • Jun 21 08:12:19 tcs2 LBT_AOSR: [I] AcquireRef[2124] complete - dx:0.789 dy:0.128 slNull: f1:Filter #0 f2:Filter #0 freq:312 mag:13.929 nBins:3 nModes:66 r0:0 snMode:0 strehl:0 ttMod:6
    • Jun 21 08:12:19 tcs2 LBT_AOSR: AOSR:AcquireRefAO execution time: 102205 ms from IIF, handle 2155

08:12:19 AcquireRefAO SUCCESS

    • Jun 21 08:12:19 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 21 08:12:20 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AORunning
    • Jun 21 08:13:19 tcs2 LBT_AOSR: [I] StartAO[2125] complete
    • Jun 21 08:13:19 tcs2 LBT_AOSR: AOSR:StartAO execution time: 60190 ms from IIF, handle 2156
  • Jun 21 08:13:19 tcs2 LBT_IIF: IIF:RunAO execution time: 162545 ms from IIF, handle 891552
  • Jun 21 08:13:19 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

08:13:19 RunAO SUCCESS

  • Jun 21 08:13:20 tcs2 LBT_IIF: IIF:OffsetZAO executed from IIF, handle 892034
  • Jun 21 08:13:21 tcs2 LBT_IIF: IIF:OffsetZAO execution time: 1203 ms from IIF, handle 892034
  • Jun 21 08:24:15 tcs2 LBT_IIF: IIF:OffsetZAO executed from IIF, handle 894086
  • Jun 21 08:24:17 tcs2 LBT_IIF: IIF:OffsetZAO execution time: 2730 ms from IIF, handle 894086
  • Jun 21 08:50:07 tcs2 LBT_IIF: IIF:OffsetZAO executed from IIF, handle 899410
  • Jun 21 08:50:10 tcs2 LBT_IIF: IIF:OffsetZAO execution time: 2856 ms from IIF, handle 899410
    • Jun 21 09:09:55 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AOSet
    • Jun 21 09:17:25 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AOSet
  • Jun 21 09:27:01 tcs2 LBT_IIF: IIF:Preset execution time: 52095 ms from IIF, handle 906303
  • Jun 21 09:27:01 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
09:27:01 irc:PresetTelescope command status: SUCCESS

  • Jun 21 09:30:41 tcs2 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 21 09:30:41 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 21 09:31:55 tcs2 LBT_AOSR: [I] PresetAO[2224] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 21 09:31:55 tcs2 LBT_AOSR: AOSR:PresetAO execution time: 74029 ms from IIF, handle 2255
  • Jun 21 09:31:55 tcs2 LBT_IIF: IIF:Preset execution time: 80670 ms from IIF, handle 907095
  • Jun 21 09:31:55 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
09:31:55 PresetAO SUCCESS

  • Jun 21 09:34:24 tcs2 LBT_IIF: IIF:Preset execution time: 23012 ms from IIF, handle 907699
  • Jun 21 09:34:24 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
09:34:24 irc:PresetTelescope command status: SUCCESS

  • Jun 21 09:35:27 tcs2 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 21 09:35:27 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 21 09:36:09 tcs2 LBT_AOSR: [I] PresetAO[2227] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 21 09:36:09 tcs2 LBT_AOSR: AOSR:PresetAO execution time: 41949 ms from IIF, handle 2258
  • Jun 21 09:36:09 tcs2 LBT_IIF: IIF:Preset execution time: 43738 ms from IIF, handle 907957
  • Jun 21 09:36:09 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
09:36:09 PresetAO SUCCESS

  • Jun 21 09:36:20 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 908119
    • Jun 21 09:36:20 tcs2 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 2259
    • Jun 21 09:36:20 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 21 09:36:20 tcs2 LBT_AOSR: [D] AcquireRef command received.
    • Jun 21 09:36:20 tcs2 LBT_AOSR: [I] AcquireRef[2228]
    • Jun 21 09:36:43 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AORunning
    • Jun 21 09:37:18 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AOSet
    • Jun 21 09:37:47 tcs2 LBT_AOSR: [I] AcquireRef[2228] complete - dx:0.598 dy:0.443 slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:6.622 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 21 09:37:47 tcs2 LBT_AOSR: AOSR:AcquireRefAO execution time: 87338 ms from IIF, handle 2259

09:37:47 AcquireRefAO SUCCESS

    • Jun 21 09:37:47 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 21 09:37:48 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AORunning
    • Jun 21 09:38:14 tcs2 LBT_AOSR: [I] StartAO[2229] complete
    • Jun 21 09:38:14 tcs2 LBT_AOSR: AOSR:StartAO execution time: 26849 ms from IIF, handle 2260
  • Jun 21 09:38:14 tcs2 LBT_IIF: IIF:RunAO execution time: 114235 ms from IIF, handle 908119
  • Jun 21 09:38:14 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

09:38:14 RunAO SUCCESS

  • Jun 21 09:38:26 tcs2 LBT_IIF: IIF:OffsetZAO executed from IIF, handle 908454
  • Jun 21 09:38:29 tcs2 LBT_IIF: IIF:OffsetZAO execution time: 2853 ms from IIF, handle 908454
    • Jun 21 10:42:43 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AOSet
  • Jun 21 10:55:39 tcs2 LBT_IIF: IIF:Preset execution time: 53844 ms from IIF, handle 923796
  • Jun 21 10:55:39 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
10:55:39 irc:PresetTelescope command status: SUCCESS

  • Jun 21 10:57:05 tcs2 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 21 10:57:05 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 21 10:57:49 tcs2 LBT_AOSR: [I] PresetAO[2235] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 21 10:57:49 tcs2 LBT_AOSR: AOSR:PresetAO execution time: 43431 ms from IIF, handle 2266
  • Jun 21 10:57:49 tcs2 LBT_IIF: IIF:Preset execution time: 50202 ms from IIF, handle 924182
  • Jun 21 10:57:49 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
10:57:49 PresetAO SUCCESS

  • Jun 21 10:58:12 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 924390
    • Jun 21 10:58:12 tcs2 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 2267
    • Jun 21 10:58:12 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 21 10:58:12 tcs2 LBT_AOSR: [D] AcquireRef command received.
    • Jun 21 10:58:12 tcs2 LBT_AOSR: [I] AcquireRef[2236]
    • Jun 21 10:58:37 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AORunning
    • Jun 21 10:59:23 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AOSet
    • Jun 21 10:59:52 tcs2 LBT_AOSR: [I] AcquireRef[2236] complete - dx:0.644 dy:0.879 slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:6.594 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 21 10:59:52 tcs2 LBT_AOSR: AOSR:AcquireRefAO execution time: 99538 ms from IIF, handle 2267

10:59:52 AcquireRefAO SUCCESS

    • Jun 21 10:59:52 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 21 10:59:53 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AORunning
    • Jun 21 11:00:18 tcs2 LBT_AOSR: [I] StartAO[2237] complete
    • Jun 21 11:00:18 tcs2 LBT_AOSR: AOSR:StartAO execution time: 26315 ms from IIF, handle 2268
  • Jun 21 11:00:18 tcs2 LBT_IIF: IIF:RunAO execution time: 125906 ms from IIF, handle 924390
  • Jun 21 11:00:18 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

11:00:18 RunAO SUCCESS

  • Jun 21 11:01:39 tcs2 LBT_IIF: IIF:OffsetZAO executed from IIF, handle 924946
  • Jun 21 11:01:42 tcs2 LBT_IIF: IIF:OffsetZAO execution time: 2455 ms from IIF, handle 924946
    • Jun 21 11:26:13 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AOSet

  • Jun 21 11:26:15 tcs2 LBT_IIF: irc:PresetTelescope executed from IIF
    • Jun 21 11:26:15 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:PresetAO
    • Jun 21 11:26:58 tcs2 LBT_AOSR: [I] PresetAO[2240] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 21 11:26:58 tcs2 LBT_AOSR: AOSR:PresetAO execution time: 43243 ms from IIF, handle 2271
  • Jun 21 11:27:25 tcs2 LBT_IIF: IIF:Preset execution time: 77738 ms from IIF, handle 929463
  • Jun 21 11:27:25 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
11:27:25 PresetAO SUCCESS

  • Jun 21 11:29:13 tcs2 LBT_IIF: IIF:RunAO executed from IIF, handle 929990
    • Jun 21 11:29:14 tcs2 LBT_AOSR: AOSR:AcquireRefAO executed from IIF, handle 2272
    • Jun 21 11:29:14 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:AcquireRefAO
    • Jun 21 11:29:14 tcs2 LBT_AOSR: [D] AcquireRef command received.
    • Jun 21 11:29:14 tcs2 LBT_AOSR: [I] AcquireRef[2241]
    • Jun 21 11:29:27 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AORunning
    • Jun 21 11:30:11 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AOSet
    • Jun 21 11:30:40 tcs2 LBT_AOSR: [I] AcquireRef[2241] complete - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:6.837 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3
    • Jun 21 11:30:40 tcs2 LBT_AOSR: AOSR:AcquireRefAO execution time: 86233 ms from IIF, handle 2272

11:30:40 AcquireRefAO SUCCESS

    • Jun 21 11:30:40 tcs2 LBT_AOSR: [T] AOSCommands got: AOS:StartAO
    • Jun 21 11:30:41 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AORunning
    • Jun 21 11:31:07 tcs2 LBT_AOSR: [I] StartAO[2242] complete
    • Jun 21 11:31:07 tcs2 LBT_AOSR: AOSR:StartAO execution time: 26672 ms from IIF, handle 2273
  • Jun 21 11:31:07 tcs2 LBT_IIF: IIF:RunAO execution time: 113199 ms from IIF, handle 929990
  • Jun 21 11:31:07 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

11:31:07 RunAO SUCCESS

11:36:50 Resume[2266] failed - RETRY: Star not found - loop still paused (-20002) WFSARB_STAR_WRONGFLUX

11:36:51 irc:OffsetPointing command status: FAILED

    • Jun 21 11:37:25 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: AOSet
  • Jun 21 11:37:47 tcs2 LBT_IIF: IIF:Preset execution time: 27061 ms from IIF, handle 931444
  • Jun 21 11:37:47 tcs2 LBT_IIF: irc:PresetTelescope command status: SUCCESS
11:37:47 irc:PresetTelescope command status: SUCCESS

    • Jun 21 12:39:02 tcs2 LBT_AOSR: [D] Updated variable adsecarb.R.FSM_STATE: Ready
  • Jun 21 12:47:41 tcs2 LBT_IIF: IIF:OffsetZAO executed from IIF, handle 943737
  • Jun 21 12:47:41 tcs2 LBT_IIF: IIF:OffsetZAO execution time: 85 ms from IIF, handle 943737

-- DougMiller - 22 Jun 2012
Topic revision: r3 - 24 Jun 2012, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.