You are here: Foswiki>AdaptiveOptics Web>Ao_stats>Stats_20120207 (06 May 2012, JuanGuerra)Edit Attach

PRESET close loop ON/OFF axis..Star separation 9.74arcsec

close the loop on axis and move the second star to the center of the filed and calcualte the strehl.

failed, during the optimizing gain. seeing 2"@DIMM some preset failed due to software problem, problem debug. Series of presets. Seeing improves to 1.3"

May 6 03:24:59 tcs1 LBT_AOSL: [I] PresetAO[1433] (aomode:ACE-AO,focalst:bentGregorianBack,instr:IRTC,wfs:FLAOWFS,so1:0,so2:0,ro1:-5.42202e-07,ro2:-2.40307e-07,mag :10.85,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:nan,skybrgt:nan,windspeed:nan,winddir:nan)

May 6 03:25:30 tcs1 LBT_AOSL: [I] PresetAO[1433] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:2 nModes:100 r0:0 snMode:0 streh l:0 ttMod:3

May 6 03:28:09 tcs2 LBT_IIF: irc:RunAO command status: FAILED

May 6 03:31:46 tcs1 LBT_AOSL: [I] PresetAO[1437] (aomode:ACE-AO,focalst:bentGregorianBack,instr:IRTC,wfs:FLAOWFS,so1:0,so2:0,ro1:2.3938e-06,ro2:-2.02954e-07,mag:1 0.85,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:nan,skybrgt:nan,windspeed:nan,winddir:nan)

May 6 03:32:25 tcs1 LBT_AOSL: [I] PresetAO[1437] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:2 nModes:100 r0:0 snMode:0 streh l:0 ttMod:3

May 6 03:33:56 tcs2 LBT_IIF: irc:RunAO command status: FAILED

May 6 03:34:59 tcs1 LBT_AOSL: [I] PresetAO[1441] (aomode:ACE-AO,focalst:bentGregorianBack,instr:IRTC,wfs:FLAOWFS,so1:0,so2:0,ro1:8.05456e-07,ro2:-1.65986e-07,mag: 10.85,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:nan,skybrgt:nan,windspeed:nan,winddir:nan)

May 6 03:35:30 tcs1 LBT_AOSL: [I] PresetAO[1441] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:2 nModes:100 r0:0 snMode:0 streh l:0 ttMod:3

May 6 03:38:02 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

preset failed. Open the loop due to shell RIP. check log.. This was a cause of the GCS was active and the secondary got too much tilt. the sequence of this failure was:
close loop
offset to take some sky. Loop pause.
offset back. slit didn't move and the loop was resume from the AOS. success.
shell rip. The GCS was running meantime the loop was close.

May  6 04:21:26 tcs1 LBT_AOSL: [W] OffsetXY[1511] failed - Command timeout - -13107: Arbitrator interface generic error
May  6 04:21:54 tcs4 LBT_left_GCS: star verification failed.
May  6 04:22:05 tcs4 LBT_left_GCS: star verification failed.
May  6 04:25:14 tcs1 LBT_AOSL: [W] Stop[1513] failed - Command timeout - -13107: Arbitrator interface generic error

May 6 04:33:19 tcs1 LBT_AOSL: [I] PresetAO[1515] (aomode:ACE-AO,focalst:bentGregorianBack,instr:IRTC,wfs:FLAOWFS,so1:0,so2:0,ro1:2.48668e-06,ro2:-3.50329e-08,mag: 7.74,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:nan,skybrgt:nan,windspeed:nan,winddir:nan)

FOcus vs position.

with a seeing variable 1.6" to 1.3" the autofocus didn't find the right right value of the focus (moving Z stage).
During this focus procedure, the star was drifted. This has to be checked with the images.. TO CHECK !! IMPORTANT

May 6 05:23:29 tcs1 LBT_AOSL: [I] PresetAO[1533] (aomode:ACE-AO,focalst:bentGregorianBack,instr:IRTC,wfs:FLAOWFS,so1:0,so2:0,ro1:-2.74724e-06,ro2:-7.44617e-08,mag :4.7,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:nan,skybrgt:nan,windspeed:nan,winddir:nan)

May 6 05:26:55 tcs2 LBT_IIF: irc:RunAO command status: SUCCESS

The loop is open due to clouds.

Preset with clouds.

the DIMM didn't find the star.

May 6 06:43:35 tcs1 LBT_AOSL: [I] PresetAO[1566] (aomode:ACE-AO,focalst:bentGregorianBack,instr:IRTC,wfs:FLAOWFS,so1:0,so2:0,ro1:1.01338e-07,ro2:-2.45419e-06,mag: 6.2,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:nan,skybrgt:nan,windspeed:nan,winddir:nan)
Sun May  6 06:48:15.966 2012 aos.StartAO.failed - StartAO[1569] failed - Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
Preset failed during the autogain procedure.

May 6 06:50:17 tcs1 LBT_AOSL: [I] PresetAO[1571] (aomode:ACE-AO,focalst:bentGregorianBack,instr:IRTC,wfs:FLAOWFS,so1:0,so2:0,ro1:4.70518e-08,ro2:-2.9376e-07,mag:6 .2,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:nan,skybrgt:nan,windspeed:nan,winddir:nan)

problem with too many rip

MOVE TO RIGHT SIDE.

RIP OF THE SHELL 20120605 07:55:53.2197 Alert: Error: COILS DISABLED 20120605 07:55:53.2243 Alert: Error: COILS DISABLED 20120605 07:55:53.2418 Alert: Error: COILS DISABLED 20120605 07:55:53.2989 Alert: Error: COILS DISABLED

seeing 2"

Sun May 6 08:35:20.285 2012 aos.AcquireRef.complete - AcquireRef[51] complete - dx:1.938 dy:-1.158 slNull: f1:Filter #1 f2:Filter #0 freq:990 mag:8.955 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3 Sun May 6 08:35:20.520 2012 aos.StartAO.started - StartAO[52]

seeing 2.9"

back to left: 9:14

Work out to identify the less performances of the bin 1. The two actuator removed are restored.

9:20 preset, TYC3477, MODE=ACE, GS=1, RS=0

Skip frames during the autogain. The two actuator will be alive put it back.

Sun May 6 09:36:58.556 2012 aos.PresetAO.started - PresetAO[1611] (aomode:ACE-AO,focalst:bentGregorianBack,instr:IRTC,wfs:FLAOWFS,so1:0,so2:0,ro1:3.47716e-07,ro2:-1.80796e-07,mag:6.75,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:nan,skybrgt:nan,windspeed:nan,winddir:nan)

Sun May 6 10:47:22.672 2012 aos.PresetAO.started - PresetAO[1616] (aomode:ACE-AO,focalst:bentGregorianBack,instr:IRTC,wfs:FLAOWFS,so1:0,so2:0,ro1:1.1223e-06,ro2:1.53273e-07,mag:6.71,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:nan,skybrgt:nan,windspeed:nan,winddir:nan)

seeing 1" Sun May 6 11:00:55.362 2012 aos.info - Maximum skip reached Sun May 6 11:00:55.401 2012 aos.error - Stopping WFS... Sun May 6 11:00:55.728 2012 aos.error - Stopping AdSec

Sun May 6 11:06:05.396 2012 aos.PresetAO.complete - PresetAO[1626] complete - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3 Sun May 6 11:09:56.956 2012 aos.info - Maximum skip reached Sun May 6 11:09:57.016 2012 aos.error - Stopping WFS... Sun May 6 11:09:57.386 2012 aos.error - Stopping AdSec

Sun May 6 11:10:53.509 2012 aos.PresetAO.started - PresetAO[1630] (aomode:ACE-AO,focalst:bentGregorianBack,instr:IRTC,wfs:FLAOWFS,so1:0,so2:0,ro1:0.00033576,ro2:0.000421314,mag:6.71,cindex:0,elev:nan,rotang:nan,gravang:nan,r0:nan,skybrgt:nan,windspeed:nan,winddir:nan)

Sun May 6 11:14:44.185 2012 aos.info - Maximum skip reached Sun May 6 11:14:44.209 2012 aos.error - Stopping WFS... Sun May 6 11:14:44.559 2012 aos.error - Stopping AdSec

finish 11:51

-- JuanGuerra - 06 May 2012
Topic revision: r4 - 06 May 2012, JuanGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback